Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Global Overview of Energy Storage Performance Test Protocols

As part of the World Bank Energy Storage Partnership, this document seeks to provide support and knowledge to a set of stakeholders across the developing world as we all seek to analyze the emerging opportunities and technologies for energy storage in the electric sector. As global prices for renewable energy have dropped dramatically over the last decade and continue to decline and the value of energy storage has increased in many systems, the World Bank technical teams and others have been hearing of a variety of problems. Related, developing countries have been asking a series of questions in this new area. This working group seeks to address the issues raised in part by creating this document and working to gather a variety of experts in this area from across the globe in support of the World Bank efforts. Performance testing, in combination with test beds (Working Group 2), is critical to fulfill the promise offered by these breakthrough technologies and critical to increasing trust in these systems and reducing risk. This document seeks to provide information to stakeholders in developing countries on the current global performance testing landscape of the battery (and broader) performance testing landscape. This document does that by summarizing testing protocols published by key global entities. From this summary, it can be concluded that there are several organizations within each region that set protocols for the testing and specifications of stationary energy storage systems. Across most of these entities, there are extensive protocols for testing batteries for electrical vehicles and mobile devices, but less for large scale energy storage system and their usage cases. The working group and the Partnership more generally agree that the nascent markets for certain technologies and rapid growth make testing more important than ever as these markets continue to mature. This document also seeks to provide a set of "guideposts" to new entrants by pointing out some of the key organizations globally that are currently engaged in performance testing of energy storage systems (often batteries but the larger organizations are likely to engage in tailored tests for emerging thermal and other storage technologies).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The EUROTRANS Project

Accelerator Driven Systems (ADS) for nuclear waste transmutation require proton drivers with energies between 600 and 800 MeV and beam currents of several mA for demonstrators and up to 25 mA for large industrial systems. Within the EUROTRANS project a 600 MeV linac has been designed to meet the stringent requirements regarding reliability, availability and extreme low beam losses. The first accelerating section using the novel CH-cavity accelerates the beam to 17 MeV at the injection point into the main linac. The intermediate energy section (17-100 MeV) of the main linac consists of superconducting independently phased spoke-type cavities followed by the high energy section consisting of 704 MHz superconducting elliptical cavities. The paper covers the development of the linac, prototype testing and reliability considerations of the whole EUROTRANS project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Device-Level Thermal Management of Gallium Oxide Field-Effect Transistors

The ultra-wide bandgap (~4.8 eV) and melt-grown substrate availability of β-Ga 2 O 3 gives promise to the development of next generation power electronic devices with dramatically improved size, weight, power, and efficiency over current state-of-the-art wide bandgap devices based on 4H-SiC and GaN. Also, with recent advancements made in GHz frequency RF applications, the potential for monolithic or heterogenous integration of RF and power switches has attracted researchers’ attention. Yet, it is expected that Ga 2 O 3 devices will suffer from self-heating due to the poor thermal conductivity of the material. Thermoreflectance thermal imaging and infrared thermography were used to understand the thermal characteristics of a MOSFET fabricated via homo-epitaxy. A 3D coupled electro-thermal model was constructed based on the electrical and thermal characterization results. The device model shows that a homo-epitaxial device suffers from an unacceptable junction temperature rise of ~1500°C under a targeted power density of 10 W/mm indicating the importance of employing device level thermal managements to individual Ga 2 O 3 transistors. The effectiveness of various active and passive cooling solutions was tested to achieve a goal of reducing the device operating temperature below 200°C at a power density of 10 W/mm. Results show that flip-chip hetero-integration is a viable option to enhance both the steady-state and transient thermal characteristics of Ga 2 O 3 devices without sacrificing the intrinsic advantage of high-quality native substrates. Also, it is not an active thermal management solution that entails peripherals requiring additional size and cost implications.

42 ENGINEERING↗

SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and the PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.

60 APPLIED LIFE SCIENCES↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process intensification of CO 2 absorption using a 3D printed intensified packing device

In this study, we present a first of its kind demonstration of successful enhancement of CO 2 chemical absorption, under selected conditions, using a process intensification approach. A multifunctional device that integrates contact of phases and heat exchange has been developed, characterized, and tested. Heat transfer analysis has demonstrated the efficacy of the device as a heat exchanger, and mass transfer results have shown substantial improvement in the uptake of CO 2 under a range of operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of high-deflection foils MHK applications - FEA models - Helical turbines

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. FEA models - NASTRAN Helical foil turbines tested at UNH tow tank Glass and carbon composite material properties Loads derived from CFD models

16 TIDAL AND WAVE POWER↗

Corrective Action Investigation Plan for Corrective Action Unit 413: Clean Slate II Plutonium Dispersion (TTR) Tonopah Test Range, Nevada (Rev. 1)

Corrective Action Unit (CAU) 413 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 413 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate II (CSII) storage–transportation test conducted on May 31, 1963. CAU 413 includes one corrective action site (CAS), TA-23-02CS (Pu Contaminated Soil). The known releases at CAU 413 are the result of the atmospheric deposition of contamination from the 1963 CSII test. The CSII test was a non-nuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 2 feet of soil. This test dispersed radionuclides, primarily plutonium, on the ground surface. The presence and nature of contamination at CAU 413 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 17, 2015, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 413. The CAI will include radiological surveys, geophysical surveys, collection and analyses of soil samples, and assessment of investigation results. The collection of soil samples will be accomplished using both probabilistic and judgmental sampling approaches. To facilitate site investigation and the evaluation of DQO decisions, the releases at CAU 413 have been divided into seven study groups.

54 ENVIRONMENTAL SCIENCES↗

Portable Diagnostics and Rapid Germination

In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

09 BIOMASS FUELS↗

DESIGN AND TESTING OF DIMES CARBON ABLATION RODS IN THE DIII-D TOKAMAK

We present the design of ATJ graphite rods developed for ablation experiments under high heat flux (up to 50 MW/m2) in the lower divertor of the DIII-D tokamak, a magnetic plasma confinement device. This work is motivated by the need to test ablation models relevant to carbon-based thermal shields used in high-speed spacecraft atmospheric entries, where the heat fluxes encountered can be comparable to those achieved in the DIII-D divertor plasma. Several different designs for the flowfacing side of the rod are analyzed, including "sharp nose," "blunt," and "concave". The last shape is studied for its potential to lower heat fluxes at the rod surface by increased radiation from trapped neutrals and reduced parallel plasma pressure. We also analyze the possibility of applying a thin (approximately 30 microns) layer of silicon carbide (SiC) to the exposed part of several carbon ablation rods to benchmark its erosion calculations and lifetime predictions. Such calculations are of interest as SiC represents a promising material for both thermal protection systems (TPS) and a fusion plasma-facing material (PFM). Preliminary results from the DIII-D rod ablation experiments are also discussed.

Orlov, Dmitri M.↗

Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$\alpha$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $\mu$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Evaluation of Lower-Energy Energy Storage Alternatives for Full-Hybrid Vehicles; NREL (National Renewable Energy Laboratory)

Automakers have been mass producing hybrid electric vehicles (HEVs) for well over a decade, and the technology has proven to be very effective at reducing per-vehicle fuel use. However, the incremental cost of HEVs such as the Toyota Prius or Ford Fusion Hybrid remains several thousand dollars higher than the cost of comparable conventional vehicles, which has limited HEV market penetration. The b b b b battery energy storage device is typically the component with the greatest contribution toward this cost increment, so significant cost reductions/performance improvements to the energy storage system (ESS) can correspondingly improve the vehicle-level cost/benefit relationship. Such an improvement would in turn lead to larger HEV market penetration and greater aggregate fuel savings. The United States Advanced Battery Consortium (USABC) and the U.S. Department of Energy (DOE) Energy Storage Program managers asked the National Renewable Energy Laboratory (NREL) to collaborate with a USABC Workgroup and analyze the trade-offs between vehicle fuel economy and reducing the decade-old minimum energy requirement for power-assist HEVs. NREL’s analysis showed that significant fuel savings could still be delivered from an ESS with much lower energy storage than the previous targets, which prompted USABC to issue a new set of lower-energy ESS (LEESS) targets that could be satisfied by a variety of technologies. With support from DOE, NREL has developed an HEV test platform for in-vehicle performance and fuel economy validation testing of the hybrid system using such LEESS devices. This presentation describes development of the vehicle test platform, and laboratory as well as in-vehicle evaluation results with alternate energy storage configurations as compared to the production battery system. The alternate energy storage technologies considered include lithium-ion capacitors -- i.e., asymmetric electrochemical energy storage devices possessing one electrode with battery-type characteristics (lithiated graphite) and one with ultracapacitor-type characteristics (carbon) -- and electrochemical double-layer capacitors.

33 ADVANCED PROPULSION SYSTEMS↗

Simulation of an active cooling system for photovoltaic modules

Photovoltaic cells are devices that convert solar radiation directly into electricity. However, solar radiation increases the photovoltaic cells temperature [1] [2]. The temperature has an influence on the degradation of the cell efficiency and the lifetime of a PV cell. This work reports on a water cooling technique for photovoltaic panel, whereby the cooling system was placed at the front surface of the cells to dissipate excess heat away and to block unwanted radiation. By using water as a cooling medium for the photovoltaic solar cells, the overheating of closed panel is greatly reduced without prejudicing luminosity. The water also acts as a filter to remove a portion of solar spectrum in the infrared band but allows transmission of the visible spectrum most useful for the PV operation. To improve the cooling system efficiency and electrical efficiency, uniform flow rate among the cooling system is required to ensure uniform distribution of the operating temperature of the PV cells. The aims of this study are to develop a 3D thermal model to simulate the cooling and heat transfer in Photovoltaic panel and to recommend a cooling technique for the PV panel. The velocity, pressure and temperature distribution of the three-dimensional flow across the cooling block were determined using the commercial package, Fluent. The second objective of this work is to study the influence of the geometrical dimensions of the panel, water mass flow rate and water inlet temperature on the flow distribution and the solar panel temperature. The results obtained by the model are compared with experimental results from testing the prototype of the cooling device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-g shock test results of Tadiran TLM-1530MP cells.

In April of 2009, testing was done of a high-g instrumentation device that utilized Tadiran TLM-1530MP cells as a power source. As a result of that testing, it was determined that those cells exhibit failure more often when shocked in the axial direction. No failures over many tests where found when the cells were shocked laterally. Moreover, when shocked laterally, the cells exhibited no observable degradation in performance. We looked at the failed cells via non-destructive x-ray analysis to determine what internal structures failed.

25 ENERGY STORAGE↗

Hydrodynamics and Load Shedding Behavior of a Variable-Geometry Oscillating Surge Wave Energy Converter (OSWEC)

In order to improve their long-term viability, wave energy converters (WECs) need to be able to shed loads when a threshold wave condition is exceeded. As shown by Tom et al. (2016) [1], provision of adjustable flaps within the body of an oscillating surge wave energy converter (OSWEC) allows wave energy to pass through the device. A control system may then be able to open and close the flaps when waves approaching the device exceed preset thresholds. The variable-geometry OSWEC (VG-OSWEC) concept studied in this paper is a bottom-hinged, rectangular wave paddle with five flaps of elliptical cross-section embedded into the face of the paddle. System ID tests were conducted on this VG-OSWEC device at a 1:14 scale in a wave basin. Free decay tests showed that the damping was distinctly nonlinear when the flaps were fully open, and the natural frequency increased by 40% when compared with the flaps in a fully closed configuration. Tests with regular wave conditions were used to develop the response amplitude operator for the rotational motion about the hinge. These response amplitude operator results when compared with numerical simulations run using WEC-Sim/WAMIT and ANSYS AQWA, show strong agreement with the flap open and closed conditions. The regular-wave condition measurements also show that the wave excitation moment about the hinge was reduced by up to 60% when the flaps were fully open. The experiments serve to demonstrate the potential of the variable geometry design to shed loads and survive harsh ocean environments.

load shedding↗

Sensos Smart Label Performance Summary as Observed by Oak Ridge National Laboratory

The Oak Ridge National Laboratory (ORNL) team performed an evaluation of the Sensos Smart Label Gen 2.0, as shown in Figure 1, for package tracking. A long-distance round-trip shipment between Oak Ridge, Tennessee, and Seattle, Washington, was completed to assess the device’s performance in location tracking, environment sensing capabilities, alerting features, threshold options, battery life, and real-time and historical data retrieval from the “Sync” data dashboard provided by Sensos. The evaluation was conducted to gain a general understanding of the capabilities of the device. Furthermore, due to time and resource constraints, ORNL did not conduct exhaustive testing to confirm reliability, availability, or effectiveness of alerting and tracking features. On equipment arrangement, Sensos (sensos.ai) graciously agreed to provide a Sensos Smart Label Gen 2.0 device to ORNL, at no cost, for testing and evaluation purposes. ORNL conducted assessments along with other commercial off-the-shelf (COTS) tracking devices. As a courtesy, ORNL will provide Sensos with this report summarizing the observations and findings specific to the Sensos label based on the tests performed.

42 ENGINEERING↗

Resistive switching: An investigation of the bipolar–unipolar transition in Co-doped ZnO thin films

Highlights: • A purely bipolar behavior on a Co-doped ZnO thin film has been demonstrated. • We have shown what can happen if a unipolar test is performed in a purely bipolar device. • An explanation for how a sample can show a purely bipolar switching behavior was suggested. • An important open issue about resistive switching effect was put in debate. - Abstract: In order to investigate the resistive switching effect we built devices in a planar structure in which two Al contacts were deposited on the top of the film and separated by a small gap using a shadow mask. Therefore, two samples of 10% Co-doped ZnO thin films were sputtered on glass substrate. High resolution X-ray diffraction (HRXRD) revealed a highly c-axis oriented crystalline structure, without secondary phase. The high resolution scanning electron microscopy (HRSEM) showed a flat surface with good coverage and thickness about 300 nm. A Keithley 2425 semiconductor characterization system was used to perform the resistive switching tests in the bipolar and unipolar modes. Considering only the effect of compliance current (CC), the devices showed a purely bipolar behavior since an increase in CC did not induce a transition to unipolar behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar{sup 16+} and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and {>=}10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗