Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Extracting the Frequency-Dependent Dynamic Stokes Shift from Two-Dimensional Electronic Spectra with Prominent Vibrational Coherences

The dynamic Stokes shift is a common means for characterizing ultrafast solvation dynamics of electronically excited states. Here we extract the excitation frequency-dependent dynamic Stokes shift from two-dimensional electronic spectra (2DES) of cresyl violet, a molecule with a well-defined vibronic progression. The extracted dynamic Stokes shift function, S(t), exhibits oscillatory behavior, and the oscillatory components are assigned to intramolecular vibrational modes through DFT and TD-DFT calculations. Here, the well-characterized oscillations are incorporated into the fitting procedure of S(t). The excitation frequency dependence of the ultrafast response is examined through the analysis of S(t) obtained from slices taken at different excitation frequencies of the 2DES spectra. The extracted ultrafast timescales range from 36 to 98 fs, and we interpret the frequency dependence of the timescales in the context of other dynamic processes that also lead to lineshape changes in the 2DES spectrum, such as vibrational energy relaxation and spectral diffusion. Through comparison of the extracted timescales, we find that the fastest timescales are extracted over a range of excitation frequencies, where contributions from vibrational relaxation and spectral diffusion can be minimized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexing Readout of TES Microcalorimeters Based on Analog Baseband Feedback

A TES microcalorimeter array is a promising spectrometer with excellent energy resolution and a moderate imaging capability. To realize a large format array in space, multiplexing the TES signals at the low tempersture stage is mandatory. We are developing frequency division multiplexing (FDM) based on baseband feedback technique. In FDM, each TES is AC-biased with a different carrier frequency. Signals from several pixels are summed and then read out by one SQUID. The maximum number of multiplexed pixels are limited by the frequency band in which the SQUID can be operated in a flux-locked loop, which is {approx}1 MHz with standard flux-locked loop circuit. In the baseband feedback, the signal ({approx}10 kHz band) from the TES is once demodulated. Then a reconstructed copy of the modulated signal with an appropriate phase is fed back to the SQUID input coil to maintain an approximately constant magnetic flux. This can be implemented even for large cable delays and automatically suppresses the carrier. We developed a prototype electronics for the baseband feedback based on an analog phase sensitive detector (PSD) and a multiplier. Combined with Seiko 80-SSA SQUID amp, open-loop gain of 8 has been obtained for 10 kHz baseband signal at 5 MHz carrier frequency, with a moderate noise contribution of 27pA/{radical}(Hz) at input.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open-Loop Acquisition Of Frequency In BPSK

Proposed open-loop analog/digital signal-processing system would be Costas-loop error detector functioning in closed-loop manner overall. Detector estimates difference between frequency of input signal and internal reference oscillator. Estimate used to close frequency-control loop. Precise symbol timing not necessary. Performance better than systems that effect open-loop acquisition using integrators instead of low-pass filters in arms of Costas loops and in which performance varies with symbol timing.

Shah, Biren N.↗

Comparison of medium frequency pulsed radar interferometer and correlation analysis winds, part 1

In principle, the interferometer analysis determines the radial velocity and direction of single scatterers provided that each has a sufficiently different Doppler frequency to permit separation by spectral analysis. In fact, scatterers will not have constant radial velocity, and their Doppler frequencies as well as their directions will be modulated by their horizontal motion. Thus, there is a tradeoff between the poorer resolution but less smeared scatterers on shorter records and the higher resolution (longer) records. Three or more non-collinear scatterers are sufficient to determine the wind. It appears that the velocity found from the combined interferometer peaks agrees well with the apparent velocity from correlation methods, but the true velocity is a factor of 2 smaller. This difference might be resolved by searching for scatters showing regular movement between adjacent records.

Meek, C. E.↗

Patent Foramen Ovale in Patients with Cerebral Infarction: A Transesophageal Echocradigraphy Study

Patent foramen ovale was detected in 37 patients (32%). Mean age was similar in those with (60 years) and those without (64 years) PFO. Patent foramen ovale was more frequent among men (39%) than women (20%, P=.03). Patients with PFO had a lower frequency of atrial fibrillation, diabetes me!litus, hypertension, and peripheral vascular disease compared with those without PFO. There was no difference in frequency of the following characteristics in patients with PFO compared with those without PFO: pulmonary embolus, chronic obstructive pulmonary disease, pulmonary hypertension, peripheral embolism, prior cerebral infarction, nosocomial cerebral infarction, Valsalva maneuver at the time of cerebral infarction, recent surgery, or hemorrhagic transformation of cerebral infarction. Patent foramen ovale was found in 22 (40%) of 55 patients with infarcts of uncertain cause and in 15 (25%) of 61 with infarcts of known cause (cardioembolic, 21%; large vessel atherostenosis, 25%; lacune, 40%) (P=.08). When the analysis was restricted to patients who underwent Valsalva maneuver, PFO with right to left or bidirectional shunt was found in 19 (50%) of 38 patients with infarcts of uncertain cause and in 6 (20%) of 30 with infarcts of known cause (P=.Ol). Conclusion: Although PFO was over-represented in patients with infarcts of uncertain cause in our and other studies, it has a high frequency among patients with cerebral infarction of all types. The relation between PFO and stroke requires further study.

Petty, George W.↗

Quantum dynamics of a molecular emitter strongly coupled with surface plasmon polaritons: A macroscopic quantum electrodynamics approach

In this work, we study a molecular emitter above a silver surface in the framework of macroscopic quantum electrodynamics and explore the population dynamics including non-Markovian effects. The theory we present is general for molecular fluorescence in the presence of dielectrics with any space-dependent, frequency-dependent, or complex dielectric functions. Furthermore, the proposed theory allows us to calculate the memory kernel of polaritons using computational electrodynamics packages. In the limit of a high vibration frequency, the different strengths of exciton-polariton couplings lead to distinct characteristics in the population dynamics, e.g., Franck-Condon-Rabi oscillation. (The frequency of Rabi oscillation is dependent on the Franck-Condon factor.) Additionally, in a specific condition, we derive a parameter-free formula that can be used to estimate the exciton-polariton coupling between a molecular emitter and a nanocavity, and the coupling estimated by our theory is in good agreement with the reported experimental results.

Surface plasmon polaritons↗

TWO-DIMENSIONAL RADIATIVE MAGNETOHYDRODYNAMIC SIMULATIONS OF THE IMPORTANCE OF PARTIAL IONIZATION IN THE CHROMOSPHERE

The bulk of the solar chromosphere is weakly ionized and interactions between ionized particles and neutral particles likely have significant consequences for the thermodynamics of the chromospheric plasma. We investigate the importance of introducing neutral particles into the MHD equations using numerical 2.5D radiative MHD simulations obtained with the Bifrost code. The models span the solar atmosphere from the upper layers of the convection zone to the low corona, and solve the full MHD equations with non-gray and non-LTE radiative transfer, and thermal conduction along the magnetic field. The effects of partial ionization are implemented using the generalized Ohm's law, i.e., we consider the effects of the Hall term and ambipolar diffusion in the induction equation. The approximations required in going from three fluids to the generalized Ohm's law are tested in our simulations. The Ohmic diffusion, Hall term, and ambipolar diffusion show strong variations in the chromosphere. These strong variations of the various magnetic diffusivities are absent or significantly underestimated when, as has been common for these types of studies, using the semi-empirical VAL-C model as a basis for estimates. In addition, we find that differences in estimating the magnitude of ambipolar diffusion arise depending on which method is used to calculate the ion-neutral collision frequency. These differences cause uncertainties in the different magnetic diffusivity terms. In the chromosphere, we find that the ambipolar diffusion is of the same order of magnitude or even larger than the numerical diffusion used to stabilize our code. As a consequence, ambipolar diffusion produces a strong impact on the modeled atmosphere. Perhaps more importantly, it suggests that at least in the chromospheric domain, self-consistent simulations of the solar atmosphere driven by magnetoconvection can accurately describe the impact of the dominant form of resistivity, i.e., ambipolar diffusion. This suggests that such simulations may be more realistic in their approach to the lower solar atmosphere (which directly drives the coronal volume) than previously assumed.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of pilot workload - Converging measures from performance based, subjective and psychophysiological techniques

This study explores the relationship between the P300 component of the event-related brain potential (ERP) and the processing demands of a complex real-world task. Seven male volunteers enrolled in an Instrument Flight Rule (IFR) aviation course flew a series of missions in a single engine fixed-based simulator. In dual task conditions subjects were also required to discriminate between two tones differing in frequency. ERPs time-locked to the tones, subjective effort ratings and overt performance measures were collected during two 45 min flights differing in difficulty (manipulated by varying both atmospheric conditions and instrument reliability). The more difficult flight was associated with poorer performance, increased subjective effort ratings, and smaller secondary task P300s. Within each flight, P300 amplitude was negatively correlated with deviations from command headings indicating that P300 amplitude was a sensitive workload metric both between and within the flight missions.

Kramer, Arthur F.↗

Beat frequency ultrasonic microsphere contrast agent detection system

A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

Pretlow, Robert A., III↗

Beat frequency ultrasonic microsphere contrast agent detection system

A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

Pretlow, III, Robert A.↗

Visible Contrast Energy Metrics for Detection and Discrimination

Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images

Ahumada, Albert↗

Advancement in the Understanding of the Field and Frequency Dependent Microwave Surface Resistance of Niobium

The radio-frequency surface resistance of niobium resonators is incredibly reduced when nitrogen impurities are dissolved as interstitial in the material, conferring ultra-high Q-factors at medium values of accelerating field. This effect has been observed in both high and low temperature nitrogen treatments. As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped cavities, i.e. the decreasing of the Q-factor with the increasing of the radio-frequency field, come from the decreasing of the BCS surface resistance component as a function of the field. Such peculiar behavior has been considered consequence of the interstitial nitrogen present in the niobium lattice after the doping treatment. The study here presented show the field dependence of the BCS surface resistance surface of cavities with different resonant frequencies, such as: 650 MHz, 1.3 GHz, 2.6 GHz and 3.9 GHz, and processed with different state-of-the-art surface treatments. These findings show for the first time that the anti Q-slope might be seen at high frequency even for clean Niobium cavities, revealing useful suggestion on the physics underneath the anti Q-slope effect.

43 PARTICLE ACCELERATORS↗

The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS

Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount of bremsstrahlung radiation is significantly decreased.

43 PARTICLE ACCELERATORS↗

Mass, height of burst, and source–receiver distance constraints on the acoustic coda phase delay method

Here, this research uses the acoustic coda phase delay method to estimate relative changes in air temperature between explosions with varying event masses and heights of burst. It also places a bound on source–receiver distance for the method. Previous studies used events with different shapes, height of bursts, and masses and recorded the acoustic codas at source–receiver distances less than 1 km. This research further explores the method using explosions that differ in mass (by up to an order of magnitude) and are placed at varying heights. Source–receiver distances also cover an area out to 7 km. Relative air temperature change estimates are compared to complementary meteorological observations. Results show that two explosions that differ by an order of magnitude cannot be used with this method because their propagation times in the near field and their fundamental frequencies are different. These differences are expressed as inaccuracies in the relative air temperature change estimates. An order of magnitude difference in mass is also shown to bias estimates higher. Small differences in height of burst do not affect the accuracy of the method. Finally, an upper bound of 1 km on source–receiver distance is provided based on the standard deviation characteristics of the estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Visibility of DCT Quantization Noise: Spatial Frequency Summation

Computational models of the ability to detect image compression artifacts facilitate the optimization of compression parameters, such as the JPEG quantization matrix. For simplicity, some models assume that the visibility of artifacts containing different spatial frequency components is determined by the most visible component, that is, no summation over components. Using the type of noise generated by quantization in the Discrete Cosine Transform (DCT) domain, we find a degree of summation between that of probability summation and contrast energy summation.

Peterson, H. A.↗