Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Role of Energy Storage with Renewable Electricity Generation (Report Summary) (Presentation)

Renewable energy sources, such as wind and solar, have vast potential to reduce dependence on fossil fuels and greenhouse gas emissions in the electric sector. Climate change concerns, state initiatives including renewable portfolio standards, and consumer efforts are resulting in increased deployments of both technologies. Both solar photovoltaics (PV) and wind energy have variable and uncertain(sometimes referred to as 'intermittent') output, which are unlike the dispatchable sources used for the majority of electricity generation in the United States. The variability of these sources has led to concerns regarding the reliability of an electric grid that derives a large fraction of its energy from these sources as well as the cost of reliably integrating large amounts of variablegeneration into the electric grid. In this report, we explore the role of energy storage in the electricity grid, focusing on the effects of large-scale deployment of variable renewable sources (primarily wind and solar energy).

14 SOLAR ENERGY↗

Quantifying CO 2 Plume Stabilization at Carbon Storage Projects, North Dakota, USA

This study presents an approach for quantifying when injected carbon dioxide (CO 2 ) stabilizes pursuant to carbon capture and storage (CCS) project permitting and site closure requirements. The distribution of mobile-phase CO 2 (CO 2 plume) will evolve within the storage reservoir during and after injection through both physical and chemical trapping mechanisms. CCS policies generally agree that the CO 2 plume’s migratory behavior in post-injection should demonstrate nonendangerment to the environment but do not provide specific guidance on how to meet the definition of plume stabilization, generating some uncertainty for operators. Plume stability herein means the CO 2 plume 1) changes size minimally and predictably in the storage reservoir such that it will not cross key boundaries identified in the permit and 2) does not pose a threat to human health, underground sources of drinking water (USDWs), and the environment because of lateral migration to areas where leakage pathways may exist. Published literature on plume metrics was reviewed to determine which metric(s) may be most appropriate for determining CO 2 plume stability. A technical approach that defines plume stabilization by estimating the rate of change in the geographic footprint of the CO 2 plume with respect to time was developed and illustrated using a case study from North Dakota, USA, as a proposed solution for CCS operators to apply at the project permitting stage. Any prospective CCS operator may benefit from using the same approach to inform the selection of pore space lease and monitoring areas and develop post-injection site care plans.

03 NATURAL GAS↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparing Distribution Utilities for the Future - Evolving Customer Consumption in Renewable Rich Grids: A Novel Analytical Framework

The research collaboration between NREL and BYPL focuses on the challenges caused by renewable integration into the power grid at large. Since the challenges and opportunities vary depending on the point of interconnection (distribution or transmission) the research team identified two tracks for research as listed below: 1. Power procurement - This research track focuses on the challenges and opportunities caused by GW scale renewable integration at the transmission level. Specifically, this track focuses on the contribution that utility-scale renewable energy procurement provides to distribution utilities, both from energy and capacity perspectives. In this track of research, utility customers are only considered as traditional (one-directional) consumers of energy. 2. Distributed energy resources - This research track focuses on the challenges and opportunities caused by many small-scale distributed renewable resource integrations at the distribution systems. At the power distribution level, distribution utilities may face not only new solar energy technologies, but also battery energy storage and electric vehicles as well. These three technologies (solar PV, battery energy storage, and electric vehicles) combined, pose unique challenges to distribution utilities. This track focuses on assessing the net-load evolution that distribution utilities observe as these emerging technologies make their way to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of Photovoltaics and Battery Storage for Maine [Slides]

Maine GEO was interested in a small-scale pilot using REopt to expand on previous resilience efforts and better understand the most useful information to gather from facilities to maximize the efficacy of the analysis. The pilot began with identification of three pilot facilities from the existing Maine Community Resilience Partnership (MCRP) cohort, selection of the facilities prioritizing: social vulnerability, community led planning work and commitment to ongoing work. The technical assistance focused on working with identified facilities to help scope the project and identify their goals and then provide technical specifications on optimal energy generation and storage strategies for each community. At the conclusion of the project, participating facilities received a REopt analysis report, including optimal generation and storage strategies to address identified goals and next steps and considerations for implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Authentication of smart grid communications using quantum key distribution

Smart grid solutions enable utilities and customers to better monitor and control energy use via information and communications technology. Information technology is intended to improve the future electric grid’s reliability, efficiency, and sustainability by implementing advanced monitoring and control systems. However, leveraging modern communications systems also makes the grid vulnerable to cyberattacks. Here we report the first use of quantum key distribution (QKD) keys in the authentication of smart grid communications. In particular, we make such demonstration on a deployed electric utility fiber network. The developed method was prototyped in a software package to manage and utilize cryptographic keys to authenticate machine-to-machine communications used for supervisory control and data acquisition (SCADA). This demonstration showcases the feasibility of using QKD to improve the security of critical infrastructure, including future distributed energy resources (DERs), such as energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The pp{yields}p{Lambda}K{sup +} and pp{yields}p{Sigma}{sup 0}K{sup +} reactions with chiral dynamics

We report on a theoretical study of the pp{yields}p{Lambda}K{sup +} and pp{yields}p{Sigma}{sup 0}K{sup +} reactions near threshold using a chiral dynamical approach. The production process is described by single-pion and single-kaon exchange. The final state interactions of nucleon-hyperon, K-hyperon, and K-nucleon systems are also taken into account. We show that our model leads to a fair description of the experimental data on the total cross section of the pp{yields}p{Lambda}K{sup +} and pp{yields}p{Sigma}{sup 0}K{sup +} reactions. We find that the experimental observed strong suppression of {Sigma}{sup 0} production compared to {Lambda} production at the same excess energy can be explained. However, ignorance of phases between some amplitudes does not allow one to properly account for the nucleon-hyperon final state interaction for the pp{yields}p{Sigma}{sup 0}K{sup +} reaction. We also demonstrate that the invariant mass distribution and the Dalitz plot provide direct information about the {Lambda} and {Sigma}{sup 0} production mechanisms and may be tested by experiments at COSY or HIRFL-CSR.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dual-stage K + ion intercalation in V 2 O 5 -conductive polymer composites

We reported that the incorporation of a conductive polymer into V 2 O 5 materials resulted in an increased interlayer distance of 2.2 nm, favoring K + ion storage in aqueous electrolyte. In situ X-ray diffraction showed that during charging, K + ions were first inserted into the interlayer region of V 2 O 5 through pseudocapacitive intercalation and then continued to be inserted into the [VO 6 ] bi-layer region via diffusion-limited intercalation. Furthermore, this reversible dual-stage insertion/extraction mechanism provides new battery chemistry allowing the storage of around 50% more alkali ions in the intralayer region besides van der Waals gaps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space Station Freedom power management and distribution design status

The design status of the power management and distribution electric power system for the Space Station Freedom is presented. The current design is a star architecture, which has been found to be the best approach for meeting the requirement to deliver 120 V dc to the user interface. The architecture minimizes mass and power losses while improving element-to-element isolation and system flexibility. The design is partitioned into three elements: energy collection, storage and conversion, system protection and distribution, and management and control.

Javidi, S.↗

Washington Clean Energy Fund Grid Modernization Projects: Economic Analysis (Final Report)

As part of CEF Round 1 funding, Pacific Northwest National Laboratory (PNNL) was engaged by the U.S. Department of Energy (DOE) and the Washington Department of Commerce to work with Puget Sound Energy (PSE), Avista, and Snohomish Public Utility District (SnoPUD) in evaluating the economic and technical performance of each of their battery energy storage systems (BESSs). This report presents the final results of the economic assessment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Degradation of ESR in Polymer Tantalum Capacitors During High Temperature Storage

Replacement of MnO2 cathodes with conductive polymers in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. Due to degradation processes in conductive polymer materials, the existing quality assurance testing that has been developed for MnO2 capacitors is not sufficient to guarantee long-term stability of CPTCs. Insertion of CPTCs in hi-rel systems requires development of models that can predict degradation of the parts at operating conditions. In this work, variations of AC characteristics (capacitance, DF and ESR) in different types of capacitors from three manufacturers have been monitored during storage at temperatures from 100ºC to 175ºC for periods of up to 15,000 hours. Results show that the most sensitive to degradation parameter is ESR. Distributions of times to parametric failure during storage have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of degradation and prediction of times to failure at use temperatures. Mechanisms of degradation and the effect of packaging are discussed.

equivalent series resistance (ESR)↗

High-performance mass storage system for workstations

Reduced Instruction Set Computer (RISC) workstations and Personnel Computers (PC) are very popular tools for office automation, command and control, scientific analysis, database management, and many other applications. However, when using Input/Output (I/O) intensive applications, the RISC workstations and PC's are often overburdened with the tasks of collecting, staging, storing, and distributing data. Also, by using standard high-performance peripherals and storage devices, the I/O function can still be a common bottleneck process. Therefore, the high-performance mass storage system, developed by Loral AeroSys' Independent Research and Development (IR&D) engineers, can offload a RISC workstation of I/O related functions and provide high-performance I/O functions and external interfaces. The high-performance mass storage system has the capabilities to ingest high-speed real-time data, perform signal or image processing, and stage, archive, and distribute the data. This mass storage system uses a hierarchical storage structure, thus reducing the total data storage cost, while maintaining high-I/O performance. The high-performance mass storage system is a network of low-cost parallel processors and storage devices. The nodes in the network have special I/O functions such as: SCSI controller, Ethernet controller, gateway controller, RS232 controller, IEEE488 controller, and digital/analog converter. The nodes are interconnected through high-speed direct memory access links to form a network. The topology of the network is easily reconfigurable to maximize system throughput for various applications. This high-performance mass storage system takes advantage of a 'busless' architecture for maximum expandability. The mass storage system consists of magnetic disks, a WORM optical disk jukebox, and an 8mm helical scan tape to form a hierarchical storage structure. Commonly used files are kept in the magnetic disk for fast retrieval. The optical disks are used as archive media, and the tapes are used as backup media. The storage system is managed by the IEEE mass storage reference model-based UniTree software package. UniTree software will keep track of all files in the system, will automatically migrate the lesser used files to archive media, and will stage the files when needed by the system. The user can access the files without knowledge of their physical location. The high-performance mass storage system developed by Loral AeroSys will significantly boost the system I/O performance and reduce the overall data storage cost. This storage system provides a highly flexible and cost-effective architecture for a variety of applications (e.g., realtime data acquisition with a signal and image processing requirement, long-term data archiving and distribution, and image analysis and enhancement).

Chiang, T.↗

Exascale for Energy: The Role of Exascale Computing in Energy Security

How will the United States satisfy energy demand in a tightening global energy marketplace while, at the same time, reducing greenhouse gas emissions? Exascale computing -- expected to be available within the next eight to ten years ? may play a crucial role in answering that question by enabling a paradigm shift from test-based to science-based design and engineering. Computational modeling of complete power generation systems and engines, based on scientific first principles, will accelerate the improvement of existing energy technologies and the development of new transformational technologies by pre-selecting the designs most likely to be successful for experimental validation, rather than relying on trial and error. The predictive understanding of complex engineered systems made possible by computational modeling will also reduce the construction and operations costs, optimize performance, and improve safety. Exascale computing will make possible fundamentally new approaches to quantifying the uncertainty of safety and performance engineering. This report discusses potential contributions of exa-scale modeling in four areas of energy production and distribution: nuclear power, combustion, the electrical grid, and renewable sources of energy, which include hydrogen fuel, bioenergy conversion, photovoltaic solar energy, and wind turbines. Examples of current research are taken from projects funded by the U.S. Department of Energy (DOE) Office of Science at universities and national laboratories, with a special focus on research conducted at Lawrence Berkeley National Laboratory.

08 HYDROGEN↗

Sparse distributed memory overview

The Sparse Distributed Memory (SDM) project is investigating the theory and applications of massively parallel computing architecture, called sparse distributed memory, that will support the storage and retrieval of sensory and motor patterns characteristic of autonomous systems. The immediate objectives of the project are centered in studies of the memory itself and in the use of the memory to solve problems in speech, vision, and robotics. Investigation of methods for encoding sensory data is an important part of the research. Examples of NASA missions that may benefit from this work are Space Station, planetary rovers, and solar exploration. Sparse distributed memory offers promising technology for systems that must learn through experience and be capable of adapting to new circumstances, and for operating any large complex system requiring automatic monitoring and control. Sparse distributed memory is a massively parallel architecture motivated by efforts to understand how the human brain works. Sparse distributed memory is an associative memory, able to retrieve information from cues that only partially match patterns stored in the memory. It is able to store long temporal sequences derived from the behavior of a complex system, such as progressive records of the system's sensory data and correlated records of the system's motor controls.

Raugh, Mike↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗