Search NASA⌕ Search

SEARCH · Search NASA

Results for “embedded methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Exciton states in quasi-zero-dimensional semiconductor nanosystems

The variational method in the context of the modified effective mass approximation is used to calculate the dependence of exciton ground-state energy for a quantum dot embedded in a borosilicate glassy matrix on the quantum dot radius. It is shown that the peaks in the absorption and low-temperature luminescence spectra of such a nanosystem are shifted to shorter wavelengths due to size quantization of the exciton ground-state energy in the quantum dot.

36 MATERIALS SCIENCE↗

Quantification of Proton Dose Calculation Accuracy in the Lung

Purpose: To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)–based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. Methods and Materials: A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. Results: MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ∼2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. Conclusion: Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for microwave characterization of electro-optic crystals for quantum transduction

Microwave-optic quantum transducers are essential devices to develop distributed quantum networks and implement related quantum communication protocols. Three dimensional high-coherence time microwave cavities embedded with electro-optic nonlinear dielectric materials provide promising platforms to boost the efficiency of the microwave-optic frequency conversion. However, so far, the properties for such dielectric crystals operating at milli-Kelvin cryogenic temperatures have not been well understood. Here, we propose a scheme to precisely measure and benchmark the dielectric constant and analyze the dissipation mechanisms of electro-optic materials, such as Lithium Niobate, at the quantum threshold. We will use Fermilab’s three dimensional superconducting cavities with long coherence time. The proposed method of microwave characterization lays the foundations for engineering quantum transduction devices and quantum sensors with high conversion efficiency and fidelity.

Zorzetti, Silvia↗

Overexpression of Intrinsic Hypoxia Markers HIF1{alpha} and CA-IX Predict for Local Recurrence in Stage T1-T2 Glottic Laryngeal Carcinoma Treated With Radiotherapy

Purpose: To examine the prognostic value of three endogenous hypoxia markers (hypoxia inducible factor 1 {alpha} subunit [HIF1{alpha}], carbonic anhydrase IX [CA-IX], and glucose transporter type 1 [GLUT-1]) on the clinical outcome in patients with early-stage glottic carcinoma primarily treated with radiotherapy (RT) and to determine the predictive hypoxic profile to choose the optimal treatment of early-stage laryngeal carcinoma. Methods and Materials: Immunohistochemistry for HIF1{alpha}, CA-IX, and GLUT-1 was performed on formalin-fixed, paraffin-embedded, pretreatment tissue samples of 91 glottic squamous cell carcinoma specimens. The patient group consisted only of those with early-stage (T1-T2) glottic carcinoma, and all patients were treated with RT only. Relative tumor staining was scored on the tissue samples. Receiver operating curve analysis was performed to determine the optimal cutoff value for each tumor marker. Cox regression analyses for the variables HIF1{alpha}, CA-IX, GLUT-1, gender, age, hemoglobin level, T category, N category, tobacco use, and alcohol use were performed with local control and overall survival as endpoints. Results: HIF1{alpha} overexpression in early-stage glottic carcinoma correlated significantly with worse local control (hazard ratio [HR], 3.05; p = 0.021) and overall survival (HR, 2.92; p = 0.016). CA-IX overexpression correlated significantly with worse local control (HR, 2.93; p = 0.020). GLUT-1 overexpression did not show any correlation with the clinical outcome parameters. Tumors with a nonhypoxic profile (defined as low HIF1{alpha} and low CA-IX expression) had significantly better local control (HR, 6.32; p 0.013). Conclusion: The results of our study have shown that early-stage glottic laryngeal carcinomas with low HIF1{alpha} and CA-IX expression are highly curable with RT. For this group, RT is a good treatment option. For tumors with HIF1{alpha} or CA-IX overexpression, hypoxic modification before RT or primary surgical treatment should be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray absorption spectroscopy characterization of embedded and extracted nano-oxides

Here, the chemistries and structures of both embedded and extracted Ysingle bondTisingle bondO nanometer-scale oxides in a nanostructured ferritic alloy (NFA) were probed by x-ray absorption spectroscopy (XAS). Y 2 Ti 2 O 7 is the primary embedded phase, while the slightly larger extracted oxides are primarily Y 2 TiO 5 . Analysis of the embedded nano-oxides is difficult partly due to the multiple Ti environments associated with different oxides and those still residing in matrix lattice sites. Thus, bulk extraction followed by selective filtration was used to isolate the larger Y 2 TiO 5 oxides for XAS, while the smaller predominant embedded phase Y 2 Ti 2 O 7 oxides passed through the filters and were analyzed using the log-ratio method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of multi-objective core optimization framework and application to sodium-cooled fast test reactors

The optimization of a Sodium-cooled Fast Reactor (SFR) core is a challenging process, due to the large number of design parameters, the nonlinearities among inputs and outputs, and the complicated correlation among output parameters. This study attempts to develop a generalized framework for the SFR core optimization by coupling the sensitivity analysis, advanced optimization algorithm, and optionally the surrogate modeling. The framework is built based on the fast reactor modeling capability of the Argonne Reactor Computation (ARC) suite and the sensitivity analysis and optimization modules embedded in the DAKOTA code, both have been integrated within the NEAMS Workbench. The genetic algorithm is selected as the optimization method for its robustness, while the option of surrogate modeling is also explored to alleviate the computational burden caused by employing the ARC direct core physics simulation and thus enhance the efficiency of the optimization. Finally, the normalized deviations of performance parameters of the near-optimal solution from those of the ideal core are calculated and used as criteria to down select the final core design. The developed framework is applied to the Advanced Burner Test Reactor (ABTR) core, and optimal solutions are determined by balancing various objectives simultaneously, including peak fast flux, core volume, power, reactivity swing, plutonium mass feed, while at the same time satisfying the predefined constraints due to safety or economics considerations. The optimal ABTR core design obtained using the direct physical simulation and surrogated model are compared and discussed. It is found that using the accurately constructed surrogate models can significantly reduce the required computational time while maintaining satisfactory accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of variational method for three-color three-photon transitions in hydrogen atom implanted in Debye plasmas

Multiphoton processes, where transparency appears, have long fascinated physicists. Plasma screening effects are investigated on three-color three-photon bound-bound transitions in hydrogen atom embedded in Debye plasmas; where photons are linearly and circularly polarized, two left circular and one right circular. All possible combinations of frequency and polarization are considered. Analytical wave functions are used for initial and final states along with the pseudostate wave functions for intermediate states. The analytical wave functions are obtained from the modified wave functions for screening Coulomb potential (Debye model) using Ritz variational method. Here, we have found three-photon transparency for lower values of Debye length. This type of phenomenon occurs due to energy level shifting in the presence of Debye plasma environments. The description of resonance enhancements and three-photon transparency is reported in the present context along with the region of resonance enhancements and three-photon transparency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced spin figure of merit in an Aharonov-Bohm ring with a double quantum dot

We theoretically investigate the thermoelectric effects in an Aharonov-Bohm ring with a serially coupled double quantum dot embedded in one arm. An external magnetic field is perpendicularly applied to the two dots. Using the nonequilibrium Green's function method in the linear-response regime, we calculate the charge and spin figures of merit. When the energy levels of the two quantum dots are equal and the system is connected to two normal leads, a large spin figure of merit (Z{sub s}T ≈ 4.5) accompanying with a small charge figure of merit (Z{sub c}T ≈ 0) can be generated due to the remarkable bipolar effect. Further, when the system is connected to two ferromagnetic leads, the spin figure of merit can reach even a higher value about 9. Afterwards, we find that Z{sub s}T is enhanced while Z{sub c}T is reduced in the coaction of the Aharonov-Bohm flux and Rashba spin-orbit coupling. It is argued that the bipolar effect is positive (negative) to spin (charge) figure of merit in the presence of level detuning of the two quantum dots and intradot Coulomb interactions, respectively. Also, we propose a possible experiment to verify our results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theory and implementation of a very high throughput true random number generator in field programmable gate array

The contribution of this paper is proposing a new entropy extraction mechanism based on sampling phase jitter in ring oscillators to make a high throughput true random number generator in a field programmable gate array (FPGA) practical. Starting from experimental observation and analysis of the entropy source in FPGA, a multi-phase sampling method is exploited to harvest the clock jitter with a maximum entropy and fast sampling speed. This parametrized design is implemented in a Xilinx Artix-7 FPGA, where the carry chains in the FPGA are explored to realize the precise phase shifting. The generator circuit is simple and resource-saving, so that multiple generation channels can run in parallel to scale the output throughput for specific applications. The prototype integrates 64 circuit units in the FPGA to provide a total output throughput of 7.68 Gbps, which meets the requirement of current high-speed quantum key distribution systems. The randomness evaluation, as well as its robustness to ambient temperature, confirms that the new method in a purely digital fashion can provide high-speed high-quality random bit sequences for a variety of embedded applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glass transition and composite formation in InF{sub 3}-containing oxyfluoroniobate system

The glasses in the system MnNbOF{sub 5}-BaF{sub 2}-InF{sub 3} have been firstly synthesized and studied. The thermal parameters of these glasses are analyzed. It was stated that glass of the composition 40MnNbOF{sub 5}-40BaF{sub 2}-20InF{sub 3} is the most thermal stable in the system under study. By X-ray analysis the compositions of the crystalline phases obtained at the glass thermal treatment were determined: the main phases are Ba{sub 3}In{sub 2}F{sub 12} and BaNbOF{sub 5}. By Raman and IR spectra analysis it was stated that the networks of glasses in the system are built by the structural type of the glasses in NbO{sub 2}F-BaF{sub 2} system: (NbO{sub n}F{sub m}) polyhedra joined oxygen bridges. Indium trifluoride forms InF{sub 6} polyhedra, which are embeded between oxyfluoroniobate ions, forming a common networks or forms its own layers from InF{sub 6} polyhedra. IR-spectroscopy method showed that at devitrification of the sample 30MnNbOF{sub 5}-50BaF{sub 2}-20InF{sub 3} the band position and shape change in going from glass state to crystalline. The bands in the range 900–700 cm{sup −1} shift into the low-frequency range and transformed into narrow peaks characteristic for the crystalline state. It was determined that for this sample the IR-spectroscopy method fixes the presence of the crystalline phases at 340°C without time of exposure, despite the fact that X-ray analysis shows an amorphous state for this sample at the same temperature. It was suggested, that controlling the composition and conditions of annealing of the glasses it can be obtain the transparent glass-ceramics of definite composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative characterization of the contrast mechanisms of ultra-small angle x-ray scattering imaging.

A general treatment of X-ray imaging contrast for ultra-small-angle X-ray scattering (USAXS) imaging is presented; this approach makes use of phase propagation and dynamical diffraction theory to account quantitatively for the intensity distribution at the detector plane. Simulated results from a model system of micrometer-sized spherical SiO{sub 2} particles embedded in a polypropylene matrix show good agreement with experimental measurements. Simulations by means of a separate geometrical ray-tracing method also account for the features in the USAXS images and offer a complementary view of small-angle X-ray scattering as a contrast mechanism. The ray-tracing analysis indicates that refraction, in the form of Porod scattering, and, to a much lesser extent, X-ray reflection account for the USAXS imaging contrast.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗

Temporal and spatial characterization of a thermogenic, fault-controlled gas hydrate system, Woolsey Mound, Gulf of Mexico

Woolsey Mound, located at Mississippi Canyon Lease Block 118 (MC118), is the site of the Gulf of Mexico hydrate research consortium’s seafloor observatory, where gas hydrates outcrop at the seafloor. The presence of gas hydrates in the mound is confirmed directly by coring and indirectly by 3D seismic reflection data. Craters, pockmarks, chemosynthetic communities, and authigenic carbonates populate the seafloor at Woolsey Mound. Each crater is characterized by a network of shallow crestal faults that connect the hydrate mound to the underlying allochthonous salt body. We characterize the temporal and spatial evolution of gas hydrates at Woolsey Mound under natural perturbations using four collocated 3D seismic reflection data sets that span over 14 years. Data acquisition differences embedded in the data sets arising from variation in geometry, sample rate, and phase are minimized using the “cross-equalization” method. Our results indicate that hydrate formation and dissociation vary temporally and spatially in close connection to the shallow crestal faults. Evidence of gas hydrate dissociation is observed over a period of three years (2000–2003), where major dissociation occurred along the southern portion of the crestal fault in the southeast crater. The dissociation is less prominent in the southwest crater. Evidence of methane venting is observed between 2000 and 2010, which is mostly concentrated in the southeast crater. The residual amplitude anomalies observed between 2000 and 2014 in the mound are mostly positive, implying that the methane venting had increased significantly. The positive anomalies are correlated with the methane seepage recorded in 2011. Our results indicate the evolution of a fault-controlled gas hydrate system in the northern Gulf of Mexico, which would aid in assessing its impact on the seafloor.

Geochemistry & Geophysics↗

Energy Saving Melting and Revert Reduction Technology (Energy-SMARRT): Clean Steel Casting Production

Inclusions in steel castings can cause rework, scrap, poor machining, and reduced casting performance, which can obviously result in excess energy consumption. Significant progress in understanding inclusion source, formation and control has been made. Inclusions can be defined as non-metallic materials such as refractory, sand, slag, or coatings, embedded in a metallic matrix. This research project has focused on the mold filling aspects to examine the effects of pouring methods and gating designs on the steel casting cleanliness through water modeling, computer modeling, and melting/casting experiments. Early in the research project, comprehensive studies of bottom-pouring water modeling and low-alloy steel casting experiments were completed. The extent of air entrainment in bottom-poured large castings was demonstrated by water modeling. Current gating systems are designed to prevent air aspiration. However, air entrainment is equally harmful and no prevention measures are in current practice. In this study, new basin designs included a basin dam, submerged nozzle, and nozzle extension. The entrained air and inclusions from the gating system were significantly reduced using the new basin method. Near the end of the project, there has been close collaboration with Wescast Industries Inc., a company manufacturing automotive exhaust components. Both computer modeling using Magma software and melting/casting experiments on thin wall turbo-housing stainless steel castings were completed in this short period of time. Six gating designs were created, including the current gating on the pattern, non-pressurized, partially pressurized, naturally pressurized, naturally pressurized without filter, and radial choke gating without filter, for Magma modeling. The melt filling velocity and temperature were determined from the modeling. Based on the simulation results, three gating designs were chosen for further melting and casting experiments on the same casting pattern using the lip pouring method. It was observed again that gating designs greatly influenced the melt filling velocity and the number of inclusion defects. The radial choked gating showed improvements in casting cleanliness and yield over the other gatings, even though no mold filters were used in the gating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pulsed Infrared Thermography Nondestructive Imaging of SiC-SiC f Composite Cladding Architectures; Understanding the Performance of SiC-SiC f Composite Cladding Architectures with Cr Coating in Normal Operating and Accident Conditions in LWRs and Advanced Reactors

SiC-SiC f composites, consisting of silicon carbide fibers embedded in a silicon carbide matrix, are advanced materials with high thermal conductivity, temperature stability, and resistance to radiation damage. Traditional methods for quality control of fabricated SiC-SiC f composites involve nondestructive evaluation (NDE) with X-ray computed tomography (XCT). However, XCT imaging of typical SiC-SiC f structures for cladding applications can involve several hours. In this project, we investigate an alternative approach to NDE of SiC-SiC f composites that involves rapid (on the order of seconds) imaging with Pulsed infrared thermography (PIT). PIT images of a planar SiC-SiC f specimen show the structure of the surface monolith layer and internal SiC f structures. The capability of PIT imaging in visualizing SiC f structures is qualitatively confirmed by observing similarity in the PIT and X-ray transmission images of the same specimen. Computer vision analysis of defects in the PIT image of the monolith was performed with thresholding followed by topological structural analysis that computed geometric descriptors, including major/minor axes of fitted ellipses, area, perimeter, Feret diameter, circularity, roundness, and solidity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field Emission Studies Toward Improving the Performance of DC High Voltage Photoelectron Guns

Field emission is the main mechanism that prevents DC high voltage photoemission electron guns from operating at the very high bias voltages required to produce low emittance beams. Gas conditioning is shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. The field emission characteristics of 5 stainless steel electrodes varied significantly upon the initial application of voltage but improved to nearly the same level after helium and krypton gas conditioning, exhibiting less than 10 pA field emission at - 225kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength ? 13 MV/m. Field emission could be reduced with either krypton or helium, but there were conditions related to gas choice, voltage and field strength that were more favorable than others. The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. Out of 8 electrodes (6 niobium and 2 stainless steel), the best niobium electrode performed better than the best stainless steel electrodes. Large grain niobium exhibited no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7 MV/m. Surface evaluation of all electrodes suggested no correlation between the surface roughness and the field emission current. Removing surface particulate contaminations and protrusions using an effective polishing and cleaning technique helps to prevent field emission. Mechanical polishing using silicon carbide paper and diamond paste is a common method of obtaining a mirror like surface finish on the cathode electrodes. However, it sometimes results rolled-over tips and embedded contamination. A different polishing technique was considered: electropolishing. Three stainless steel cathode electrodes with different initial surface roughness were electropolished by a commercial vendor, and evaluated inside a high voltage test stand. They exhibited less field emission than the diamond paste polished electrodes at the initial application of high voltage; but they were less receptive to ion implantation, which is a beneficial aspect of gas conditioning that serves to increase the work function of the cathode surface. Ultimately, the electropolished electrodes exhibited more field emission than diamond-paste polished electrodes.

Bastaninejad, Mahzad↗