Search NASA⌕ Search

SEARCH · Search NASA

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Accuracy of wind measurements using an airborne Doppler lidar

Simulated wind fields and lidar data are used to evaluate two sources of airborne wind measurement error. The system is sensitive to ground speed and track angle errors, with accuracy required of the angle to within 0.2 degrees and of the speed to within 1 knot, if the recovered wind field is to be within five percent of the correct direction and 10 percent of the correct speed. It is found that errors in recovered wind speed and direction are dependent on wind direction relative to the flight path. Recovery of accurate wind fields from nonsimultaneous sampling errors requires that the lidar data be displaced to account for advection so that the intersections are defined by air parcels rather than fixed points in space.

Carroll, J. J.↗

Unstructured adaptive mesh computations of rotorcraft high-speed impulsive noise

A new method is developed for modeling helicopter high-speed impulsive (HSI) noise. The aerodynamics and acoustics near the rotor blade tip are computed by solving the Euler equations on an unstructured grid. A stationary Kirchhoff surface integral is then used to propagate these acoustic signals to the far field. The near-field Euler solver uses a solution-adaptive grid scheme to improve the resolution of the acoustic signal. Grid points are locally added and/or deleted from the mesh at each adaptive step. An important part of this procedure is the choice of an appropriate error indicator. The error indicator is computed from the flow field solution and determines the regions for mesh coarsening and refinement. Computed results for HSI noise compare favorably with experimental data for three different hovering rotor cases.

Strawn, Roger↗

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

Purpose: The objective of this study was to evaluate and validate the use of the Geant4 application for emission tomography (GATE) Monte Carlo simulation platform for clinical intensity modulated radiotherapy (IMRT) dosimetry studies. Methods: The first step consisted of modeling a 6 MV photon beam linear accelerator (LINAC), with its corresponding validation carried out using percent depth dose evaluation, transverse profiles, tissue phantom ratio, and output factor on water phantom. The IMRT evaluation was performed by comparing simulation and measurements in terms of absolute and relative doses using IMRT dedicated quality assurance phantoms considering seven different patient datasets. Results: Concerning the LINAC simulated model validation tissue phantom ratios at 20 and 10 cm in water TPR{sub 10}{sup 20} obtained from GATE and measurements were 0.672 {+-} 0.063 and 0.675, respectively. In terms of percent depth dose and transverse profiles, error ranges were, respectively: 1.472%{+-} 0.285% and 4.827%{+-} 1.323% for field size of 4 Multiplication-Sign 4, 5 Multiplication-Sign 5, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15, 20 Multiplication-Sign 20, 25 Multiplication-Sign 25, 30 Multiplication-Sign 30, and 40 Multiplication-Sign 40 cm{sup 2}. Most errors were observed at the edge of radiation fields because of higher dose gradient in these areas. Output factors showed good agreement between simulation and measurements with a maximum error of 1.22%. Finally, for IMRT simulations considering seven patient datasets, GATE provided good results with a relative error of 0.43%{+-} 0.25% on absolute dose between simulated and measured beams (measurements at the isocenter, volume 0.125 cm{sup 3}). Planar dose comparisons were also performed using gamma-index analysis. For the whole set of beams considered the mean gamma-index value was 0.497 {+-} 0.152 and 90.8%{+-} 3.6% of the evaluated dose points satisfied the 5%/ 4 mm criterion. Conclusions: These results show that GATE allows reliable simulation of complex beams in radiotherapy after an accurate LINAC modeling is validated. A simple cross-calibration procedure proposed in this work allows obtaining absolute dose values even in complex fields.

60 APPLIED LIFE SCIENCES↗

Report on Modifications to the BX12 and BX13 BC1 Dipoles

Emittance growth seen during the last commissioning run in the bunch compressor optics section, BC1, was blamed on inadequate dipole field quality. The significant linear and nonlinear field non-uniformities generated large horizontal dispersion errors beyond BC1. The linear dispersion after BC1 was corrected using two small 'corrector' quadrupoles placed in BC1 for this purpose, but the remaining nonlinear field caused growth of the normalized horizontal emittance of 40% or more. At best {gamma}{epsilon}{sub x} went from 1.2 {micro}m before BC1 up to 1.7 {micro}m after BC1. The problem was magnified by the larger-than-design energy spread in BC1 due to a long initial bunch length. To improve the field quality we decided to modify the two 'inner dipoles', BX12 and BX13, of the four magnet chicane during the four month down time in the Fall of 2007. Only the two inner dipoles were chosen because of the limited time available and the fact that the beam is particularly sensitive to field quality of the inner dipoles due to its very large transverse size when going through them. The modifications were completed in November and included new poles and a new pinning scheme. The outer dipoles were left unchanged.

43 PARTICLE ACCELERATORS↗

Measuring Alignments between Galaxies and the Cosmic Web at z ∼ 2–3 Using IGM Tomography

Many galaxy formation models predict alignments between galaxy spin and the cosmic web (i.e., directions of filaments and sheets), leading to an intrinsic alignment between galaxies that creates a systematic error in weak-lensing measurements. These effects are often predicted to be stronger at high redshifts (z ≳ 1) that are inaccessible to massive galaxy surveys on foreseeable instrumentation, but IGM tomography of the Lyα forest from closely spaced quasars and galaxies is starting to measure the z ∼ 2–3 cosmic web with requisite fidelity. Using mock surveys from hydrodynamical simulations, we examine the utility of this technique, in conjunction with coeval galaxy samples, to measure alignment between galaxies and the cosmic web at z ∼ 2.5. We show that IGM tomography surveys with ≲5 h {sup −1} Mpc sightline spacing can accurately recover the eigenvectors of the tidal tensor, which we use to define the directions of the cosmic web. For galaxy spins and shapes, we use a model parameterized by the alignment strength, Δ〈cos θ〉, with respect to the tidal tensor eigenvectors from the underlying density field, and also consider observational effects such as errors in the galaxy position angle, inclination, and redshift. Measurements using the upcoming ∼1 deg{sup 2} CLAMATO tomographic survey and 600 coeval zCOSMOS-Deep galaxies should place 3σ limits on extreme alignment models with Δ〈cos θ〉∼0.1, but much larger surveys encompassing >10,000 galaxies, such as Subaru PFS, will be required to constrain models with Δ〈cos θ〉∼0.03. These measurements will constrain models of galaxy–cosmic web alignment and test tidal torque theory at z ∼ 2, improving our understanding of the physics of intrinsic alignments.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial Estimates of Dynamic Aperture and Field Quality Specifications

In this report the target field quality for the inner triplets is given. This initial specification is based on the most recent estimate of the expected field quality provided by the magnet designers. The expected field quality has been probed by means of massive numerical simulations, which are aimed at computing the dynamic aperture and its dependence on the triplet quadrupoles field imperfections. The initial estimate of the required field quality will be further analysed against measured data, whenever available, in view of possible refinement of the target errors. A preliminary check of the impact of the field quality of the other insertion magnets, both separation dipoles and quadrupoles, from D1 to Q5 has been made and a quantitative specification of the field quality will follow, always based on the expected field quality estimates.

ACCPHY↗

An error analysis of basic kinematic quantities

A description is presented of the computational procedures used to obtain spatial fields of relative vorticity, advection of vorticity, horizontal divergence, and vertical motion. An investigation is conducted of the effectiveness of these procedures to reduce the effects of deliberately introduced random errors, giving attention to the confidence which can be placed on values of the derived parameters. It is concluded that fields of 500 mb vorticity and 700 mb vertical velocity, which are frequently used in synoptic scale forecasting schemes, show minimal effects of the deliberately introduced errors. Vorticity advection is found to be the most sensitive term to input data errors. Large fluctuations in fields of this parameter are evident both statistically and qualitatively.

Berecek, E. M.↗

Mixed finite-difference scheme for analysis of simply supported thick plates.

A mixed finite-difference scheme is presented for the stress and free vibration analysis of simply supported nonhomogeneous and layered orthotropic thick plates. The analytical formulation is based on the linear, three-dimensional theory of orthotropic elasticity and a Fourier approach is used to reduce the governing equations to six first-order ordinary differential equations in the thickness coordinate. The governing equations possess a symmetric coefficient matrix and are free of derivatives of the elastic characteristics of the plate. In the finite difference discretization two interlacing grids are used for the different fundamental unknowns in such a way as to reduce both the local discretization error and the bandwidth of the resulting finite-difference field equations. Numerical studies are presented for the effects of reducing the interior and boundary discretization errors and of mesh refinement on the accuracy and convergence of solutions. It is shown that the proposed scheme, in addition to a number of other advantages, leads to highly accurate results, even when a small number of finite difference intervals is used.

Noor, A. K.↗

An algorithm to design finite field multipliers using a self-dual normal basis

Finite field multiplication is central in the implementation of some error-correcting coders. Massey and Omura have presented a revolutionary design for multiplication in a finite field. In their design, a normal base is utilized to represent the elements of the field. The concept of using a self-dual normal basis to design the Massey-Omura finite field multiplier is presented. Presented first is an algorithm to locate a self-dual normal basis for GF(2 sup m) for odd m. Then a method to construct the product function for designing the Massey-Omura multiplier is developed. It is shown that the construction of the product function base on a self-dual basis is simpler than that based on an arbitrary normal base.

Wang, C. C.↗

EXTRAPOLATION OF THE SOLAR CORONAL MAGNETIC FIELD FROM SDO/HMI MAGNETOGRAM BY A CESE-MHD-NLFFF CODE

Due to the absence of direct measurement, the magnetic field in the solar corona is usually extrapolated from the photosphere in a numerical way. At the moment, the nonlinear force-free field (NLFFF) model dominates the physical models for field extrapolation in the low corona. Recently, we have developed a new NLFFF model with MHD relaxation to reconstruct the coronal magnetic field. This method is based on CESE-MHD model with the conservation-element/solution-element (CESE) spacetime scheme. In this paper, we report the application of the CESE-MHD-NLFFF code to Solar Dynamics Observatory/Helioseismic and Magnetic Imager (SDO/HMI) data with magnetograms sampled for two active regions (ARs), NOAA AR 11158 and 11283, both of which were very non-potential, producing X-class flares and eruptions. The raw magnetograms are preprocessed to remove the force and then inputted into the extrapolation code. Qualitative comparison of the results with the SDO/AIA images shows that our code can reconstruct magnetic field lines resembling the EUV-observed coronal loops. Most important structures of the ARs are reproduced excellently, like the highly sheared field lines that suspend filaments in AR 11158 and twisted flux rope which corresponds to a sigmoid in AR 11283. Quantitative assessment of the results shows that the force-free constraint is fulfilled very well in the strong-field regions but apparently not that well in the weak-field regions because of data noise and numerical errors in the small currents.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of Lower Stratospheric Assimilated Ozone on Error Covariance Modeling and Data Selection

Assimilated ozone is produced at the NASA/Goddard Data Assimilation Office by blending ozone retrieved from the Solar Backscatter UltraViolet/2 (SBUV/2) instrument and the Earth Probe Total Ozone Mapping Spectrometer (EP TOMS) measurements into an off-line transport model. The current system tends to overestimate the amount of lower stratospheric ozone. This is a region where ozone plays a key role in the forcing of climate. A biased ozone field in this region will adversely impact calculations of the stratosphere-troposphere exchange and, when used as a first guess in retrievals, the values determined from satellite observations. Since these are all important applications of assimilated ozone products, effort is being directed towards reducing this bias. The SBUV ozone data have a coarse vertical resolution with increased uncertainty below the ozone maximum, and TOMS provides only total ozone columns. Thus, the assimilated ozone in the lower stratosphere, and its vertical distribution in particular, are only weakly constrained by the incoming SBUV and TOMS data. Consequently, the assimilated ozone distribution should be sensitive to changes in inputs to the statistical analysis scheme. Accordingly, the sensitivity of the assimilated lower stratospheric ozone fields to changes in the TOMS error-covariance modeling and the SBUV data selection has been investigated. The use of a spatially correlated TOMS error covariance model led to improvements in the product. However, withholding the SBUV/2 data for the layer between 63 and 126 hPa typically degraded the product, a result which vindicates the use of this layer ozone product, despite its known errors. These efforts to improve the lower stratospheric distribution will be extended to include a more advanced forecast error covariance model, and by assimilating ozone products from new instruments on Envisat and EOS Aura.

Stajner, Ivanka↗

SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

60 APPLIED LIFE SCIENCES↗

A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring qubit stability in a gate-based NISQ hardware processor

Some of the most problematic issues that limit the implementation of applications on Noisy Intermediate Scale Quantum (NISQ) machines are the adverse impacts of both incoherent and coherent errors. We conducted an in-depth study of coherent errors on a quantum hardware platform using a transverse field Ising model Hamiltonian as a sample user application. We report here on the results from these computations using several error mitigation protocols that profile these errors and provide an indication of the hardware qubit stability. Through a detailed set of measurements we identify inter-day and intra-day qubit calibration drift and the impacts of quantum circuit placement on groups of qubits in different physical locations on the processor. This paper also discusses how these measurements can provide a better understanding of these types of errors and how they may improve efforts to validate the accuracy of quantum computations.

Yeter-Aydeniz, Kübra↗

A Study on Particle Trajectory Error in Finite-Element Particle-in-Cell Algorithms

Particle-in-cell (PIC) algorithms are widely used for the simulation of kinetic plasmas. PIC algorithms account for the interaction between charged particles in a plasma and the electromagnetic field in ambient space, including self-field interactions. The objective of this article is to study the error in charged particle trajectories present in finite-element (FE)-based PIC algorithms on unstructured meshes. We study how the trajectory error behaves according to the FE mesh resolution and the matrix solver employed in the FE algorithm. The study is performed by considering a trajectory established by a parabolic electric potential and an axial magnetic force acting on the charged particle. Under a proper choice combination of electric and magnetic field parameters, the 2-D particle trajectories comprise closed orbits. Numerical errors cause small perturbations on the trajectories, with cumulative effects. As a result, the resulting orbital trajectories exhibit distortions including spurious apsidal precession. These distortions provide a clear imprint of the numerical error. Here, we also study the numerical error in a quantitative fashion by computing the distance norm between the trajectories obtained by the exact fields and numerical fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Computational Complexity, Parallel Scalability, and Performance of Atmospheric Data Assimilation Algorithms

The computational complexity of algorithms for Four Dimensional Data Assimilation (4DDA) at NASA's Data Assimilation Office (DAO) is discussed. In 4DDA, observations are assimilated with the output of a dynamical model to generate best-estimates of the states of the system. It is thus a mapping problem, whereby scattered observations are converted into regular accurate maps of wind, temperature, moisture and other variables. The DAO is developing and using 4DDA algorithms that provide these datasets, or analyses, in support of Earth System Science research. Two large-scale algorithms are discussed. The first approach, the Goddard Earth Observing System Data Assimilation System (GEOS DAS), uses an atmospheric general circulation model (GCM) and an observation-space based analysis system, the Physical-space Statistical Analysis System (PSAS). GEOS DAS is very similar to global meteorological weather forecasting data assimilation systems, but is used at NASA for climate research. Systems of this size typically run at between 1 and 20 gigaflop/s. The second approach, the Kalman filter, uses a more consistent algorithm to determine the forecast error covariance matrix than does GEOS DAS. For atmospheric assimilation, the gridded dynamical fields typically have More than 10(exp 6) variables, therefore the full error covariance matrix may be in excess of a teraword. For the Kalman filter this problem can easily scale to petaflop/s proportions. We discuss the computational complexity of GEOS DAS and our implementation of the Kalman filter. We also discuss and quantify some of the technical issues and limitations in developing efficient, in terms of wall clock time, and scalable parallel implementations of the algorithms.

Lyster, Peter M.↗

The Role of Model and Initial Condition Error in Numerical Weather Forecasting Investigated with an Observing System Simulation Experiment

A series of experiments that explore the roles of model and initial condition error in numerical weather prediction are performed using an observing system simulation experiment (OSSE) framework developed at the National Aeronautics and Space Administration Global Modeling and Assimilation Office (NASA/GMAO). The use of an OSSE allows the analysis and forecast errors to be explicitly calculated, and different hypothetical observing networks can be tested with ease. In these experiments, both a full global OSSE framework and an 'identical twin' OSSE setup are utilized to compare the behavior of the data assimilation system and evolution of forecast skill with and without model error. The initial condition error is manipulated by varying the distribution and quality of the observing network and the magnitude of observation errors. The results show that model error has a strong impact on both the quality of the analysis field and the evolution of forecast skill, including both systematic and unsystematic model error components. With a realistic observing network, the analysis state retains a significant quantity of error due to systematic model error. If errors of the analysis state are minimized, model error acts to rapidly degrade forecast skill during the first 24-48 hours of forward integration. In the presence of model error, the impact of observation errors on forecast skill is small, but in the absence of model error, observation errors cause a substantial degradation of the skill of medium range forecasts.

Model Error↗

ANC of Radiated Sound from a Small UAS Rotor using Virtual Error Sensors

Small unmanned aerial systems (UAS) are becoming increasingly common for private, military, and commercial use, increasing community noise exposure. Reducing the noise produced by UAS could help improve community acceptance. Active noise control (ANC) might be used to attenuate noise produced by UAS, however, traditional ANC systems require a physical sensor in the far-field, which is not feasible. This paper assesses a virtual error sensing (VES) method that eliminates the need for a far-field sensor. This paper describes the proposed VES strategy, and presents numerical simulations and experimental results that highlight the benefits and limitations of the approach. Results for the VES system alone and with an ANC approach are presented and discussed. Experimental testing focused on attenuating the tonal noise produced by one 2-bladed rotor with a tip radius of 11.9 cm. Pressure variations caused by blade rotation were measured in the near and far-field using electret microphones and externally polarized condenser microphones, respectively. The filtered-x least mean squares algorithm was used in conjunction with the VES system to attenuate the far-field response. Experimental results show reductions between 6-13 dB at varying far-field locations and rotation rates.

virtual error sensor↗