Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

SU-E-T-262: Planning for Proton Pencil Beam Scanning (PBS): Applications of Gradient Optimization for Field Matching

Purpose: To propose the gradient optimization(GO) approach in planning for matching proton PBS fields and present two commonly used applications in our institution. Methods: GO is employed for PBS field matching in the scenarios that when the size of the target is beyond the field size limit of the beam delivery system or matching is required for beams from different angles to either improve the sparing of important organs or to pass through a short and simple beam path. Overlap is designed between adjacent fields and in the overlapped junction, the dose was optimized such that it gradually decreases in one field and the decrease is compensated by increase from another field. Clinical applications of this approach on craniospinal irradiation(CSI) and whole pelvis treatment were presented. Mathematical model was developed to study the relationships between dose errors, setup errors and junction lengths. Results: Uniform and conformal dose coverage to the entire target volumes was achieved for both applications using GO approach. For CSI, the gradient matching (6.7cm junction) between fields overcame the complexity of planning associated with feathering match lines. A slow dose gradient in the junction area significantly reduced the sensitivity of the treatment to setup errors. For whole pelvis, gradient matching (4cm junction) between posterior fields for superior target and bilateral fields for inferior target provided dose sparing to organs such as bowel, bladder and rectum. For a setup error of 3 mm in longitudinal direction from one field, mathematical model predicted dose errors of 10%, 6% and 4.3% for junction length of 3, 5 and 7cm. Conclusion: This GO approach improves the quality of the PBS treatment plan with matching fields while maintaining the safety of treatment delivery relative to potential misalignments.

60 APPLIED LIFE SCIENCES↗

SU-E-T-418: Explore the Sensitive of the Planar Quality Assurance to the MLC Error with Different Beam Complexity in Intensity-Modulate Radiation Therapy

Purpose: The purpose of this study is to investigate the sensitivity of the planar quality assurance to MLC errors with different beam complexities in intensity-modulate radiation therapy. Methods: sixteen patients’ planar quality assurance (QA) plans in our institution were enrolled in this study, including 10 dynamic MLC (DMLC) IMRT plans measured by Portal Dosimetry and 6 static MLC (SMLC) IMRT plans measured by Mapcheck. The gamma pass rate was calculated using vender’s software. The field numbers were 74 and 40 for DMLC and SMLC, respectively. A random error was generated and introduced to these fields. The modified gamma pass rate was calculated by comparing the original measured fluence and modified fields’ fluence. A decreasing gamma pass rate was acquired using the original gamma pass rate minus the modified gamma pass rate. Eight complexity scores were calculated in MATLAB based on the fluence and MLC sequence of these fields. The complexity scores include fractal dimension, monitor unit of field, modulation index, fluence map complexity, weighted average of field area, weighted average of field perimeter, and small aperture ratio ( <5cm{sup 2} and <50cm{sup 2}). The Spearman’s rank correlation coefficient was implemented to analyze the correlation between these scores and decreasing gamma rate. Results: The relation between the decreasing gamma pass rate and field complexity was insignificant for most complexity scores. The most significant complexity score was fluence map complexity for SMLC, which have ρ =0.4274 (p-value=0.0063). For DMLC, the most significant complex score was fractal dimension, which have ρ=−0.3068 (p-value=0.0081). Conclusions: According to the primarily Result of this study, the sensitivity gamma pass rate was not strongly relate to the field complexity.

60 APPLIED LIFE SCIENCES↗

Radiative properties of Cirrus clouds: FIRE IFO case October 28, 1986

A description of the radiative properties of two cirrus clouds sampled on 10/28/88 in the FIRE cirrus IFO is presented. The clouds are characterized in terms of the broadband infrared effective emittance, cloud fractional absorptance, shortwave heating rate, cloud albedo and vertical velocity. The broadband fluxes used in these calculations were obtained from measurements made by pyranometers and pyrgeometers. The shortwave irradiances were corrected to a horizontal plane and normalized to the same time by taking into account Sabreliner flight information (i.e., pitch, roll, heading and angle of attack), as well as sun-earth geometry considerations. Since only one aircraft was used, broadband fluxes at different levels in the cloud were not measured simultaneously. As a result, sampling errors may occur due to the nonsteady state of the cloud field or due to the possibility that the flight legs were not flown directly above or below each other. To minimize these errors and to simplify the analysis, the necessary variables were averaged and the averages used in the calculations. The downwelling shortwave and longwave irradiances were used as selection criteria to remove cloud free data encountered along the data sampling leg.

Hein, Paul F.↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

An efficient system for reliably transmitting image and video data over low bit rate noisy channels

This research project is intended to develop an efficient system for reliably transmitting image and video data over low bit rate noisy channels. The basic ideas behind the proposed approach are the following: employ statistical-based image modeling to facilitate pre- and post-processing and error detection, use spare redundancy that the source compression did not remove to add robustness, and implement coded modulation to improve bandwidth efficiency and noise rejection. Over the last six months, progress has been made on various aspects of the project. Through our studies of the integrated system, a list-based iterative Trellis decoder has been developed. The decoder accepts feedback from a post-processor which can detect channel errors in the reconstructed image. The error detection is based on the Huber Markov random field image model for the compressed image. The compression scheme used here is that of JPEG (Joint Photographic Experts Group). Experiments were performed and the results are quite encouraging. The principal ideas here are extendable to other compression techniques. In addition, research was also performed on unequal error protection channel coding, subband vector quantization as a means of source coding, and post processing for reducing coding artifacts. Our studies on unequal error protection (UEP) coding for image transmission focused on examining the properties of the UEP capabilities of convolutional codes. The investigation of subband vector quantization employed a wavelet transform with special emphasis on exploiting interband redundancy. The outcome of this investigation included the development of three algorithms for subband vector quantization. The reduction of transform coding artifacts was studied with the aid of a non-Gaussian Markov random field model. This results in improved image decompression. These studies are summarized and the technical papers included in the appendices.

Costello, Daniel J., Jr.↗

Code-verification techniques for the method-of-moments implementation of the combined-field integral equation

Code verification plays an important role in establishing the credibility of computational simulations by assessing the correctness of the implementation of the underlying numerical methods. In computational electromagnetics, the numerical solution to integral equations incurs multiple interacting sources of numerical error, as well as other challenges, which render traditional code-verification approaches ineffective. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources for the method-of-moments implementation of the combined-field integral equation. Here, we demonstrate the effectiveness of these approaches for cases with and without coding errors.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-399: Evaluation of Selection Criteria for Computational Human Phantoms for Use in Out-Of-Field Organ Dosimetry for Radiotherapy Patients

Purpose: To quantify the dosimetric uncertainty due to organ position errors when using height and weight as phantom selection criteria in the UF/NCI Hybrid Phantom Library for the purpose of out-of-field organ dose reconstruction. Methods: Four diagnostic patient CT images were used to create 7-field IMRT plans. For each patient, dose to the liver, right lung, and left lung were calculated using the XVMC Monte Carlo code. These doses were taken to be the ground truth. For each patient, the phantom with the most closely matching height and weight was selected from the body size dependent phantom library. The patient plans were then transferred to the computational phantoms and organ doses were recalculated. Each plan was also run on 4 additional phantoms with reference heights and or weights. Maximum and mean doses for the three organs were computed, and the DVHs were extracted and compared. One sample t-tests were performed to compare the accuracy of the height and weight matched phantoms against the additional phantoms in regards to both maximum and mean dose. Results: For one of the patients, the height and weight matched phantom yielded the most accurate results across all three organs for both maximum and mean doses. For two additional patients, the matched phantom yielded the best match for one organ only. In 13 of the 24 cases, the matched phantom yielded better results than the average of the other four phantoms, though the results were only statistically significant at the .05 level for three cases. Conclusion: Using height and weight matched phantoms does yield better results in regards to out-of-field dosimetry than using average phantoms. Height and weight appear to be moderately good selection criteria, though this selection criteria failed to yield any better results for one patient.

60 APPLIED LIFE SCIENCES↗

Structure and evolution of the large scale solar and heliospheric magnetic fields

Structure and evolution of large scale photospheric and coronal magnetic fields in the interval 1976-1983 were studied using observations from the Stanford Solar Observatory and a potential field model. The solar wind in the heliosphere is organized into large regions in which the magnetic field has a componenet either toward or away from the sun. The model predicts the location of the current sheet separating these regions. Near solar minimum, in 1976, the current sheet lay within a few degrees of the solar equator having two extensions north and south of the equator. Soon after minimum the latitudinal extent began to increase. The sheet reached to at least 50 deg from 1978 through 1983. The complex structure near maximum occasionally included multiple current sheets. Large scale structures persist for up to two years during the entire interval. To minimize errors in determining the structure of the heliospheric field particular attention was paid to decreasing the distorting effects of rapid field evolution, finding the optimum source surface radius, determining the correction to the sun's polar field, and handling missing data. The predicted structure agrees with direct interplanetary field measurements taken near the ecliptic and with coronameter and interplanetary scintillation measurements which infer the three dimensional interplanetary magnetic structure. During most of the solar cycle the heliospheric field cannot be adequately described as a dipole.

Hoeksema, J. T.↗

Upgrading telescopes by active pupil wavefront correction

Exit pupil correction of the Large Deployable Reflector's (a proposed IR to sub-mm space telescope) segmented primary can be done by reimaging it onto a like segmented surface at the exit pupil. This allows the primary to be more flexible, the adaptive element to be smaller, and the supporting structure to be cheaper than if all correction were performed at a stiffly supported primary. Piston, tilt, and decenter errors of an annulus of the primary and the equations for the required corrections are considered. To verify these, the perturbations with spline functions in the lens design program are simulated. Strehl ratios used to measure image quality show that a piston error of 1 mm is fully corrected over a 5 arcmin field for an f/10 system with a 0.7 n.a. primary at 30 micrometers. Limits of correction are also shown for tilt and decenter errors of segments. Tolerances are given for tilt and decenter errors of the remaining optics also.

Stacy, J. E.↗

A simple method for verifying the deployment of the TOMS-EP solar arrays

The Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP) mission relies upon a successful deployment of the spacecraft's solar arrays. Several methods of verification are being employed to ascertain the solar array deployment status, with each requiring differing amounts of data. This paper describes a robust attitude-independent verification method that utilizes telemetry from the coarse Sun sensors (CSS's) and the three-axis magnetometers (TAM's) to determine the solar array deployment status - and it can do so with only a few, not necessarily contiguous, points of data. The method developed assumes that the solar arrays are deployed. Telemetry data from the CSS and TAM are converted to the Sun and magnetic field vectors in spacecraft body coordinates, and the angle between them is calculated. Deployment is indicated if this angle is within a certain error tolerance of the angle between the reference Sun and magnetic field vectors. Although several other methods can indicate a non-deployed state, with this method there is a 70% confidence level in confirming deployment as well as a nearly 100% certainty in confirming a non-deployed state. In addition, the spacecraft attitude (which is not known during the first orbit after launch) is not needed for this algorithm because the angle between the Sun and magnetic field vectors is independent of the spacecraft attitude. This technique can be applied to any spacecraft with a TAM and with CSS's mounted on the solar array(s).

Koppersmith, James R.↗

Request for the establishment of quantum information foundries

Quantum information science still requires basic science research to achieve its full potential. However, scientists require access to fabricated device samples if we are to utilize the full toolset for solving the pressing issues in the field such as materials, device layout, or optimal error correction methods.Currently, access to samples is either prohibitively expensive, or requires close collaboration with one of the few groups in the world developing these systems. A dedicated quantum foundry could,in principle,provide affordable samples designed with current best practices to a host of scientists who otherwise do not have access. We detail several different foundry models which we believe will assist the community in developing the science for both the underlying processes, as well as the more advanced chip layout and circuit design. Opening access to the broader community has the potential to significantly lower the barrier to entry and vastly improve the ability for researchers in fields ranging from condensed matter to materials characterization to systems engineering to contribute to accelerating the advance of quantum information science and technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-C-19A-06: A Robust and Affordable Table Indexing Approach for Total Lymphoid Irradiation Treatment

Purpose: Total lymphoid irradiation (TLI) is conventionally delivered through the dosimetric matching of mantle, spleen, and pelvis fields, necessitating multiple isocenters delivered through a combination of couch shifts and sliding of patients relative to the couch rendering the technique susceptible to shifting errors. To address this challenge, a novel technique for the couch indexing of TLI treatments is developed and evaluated through a multi-patient pilot trial. Methods: An immobilization device was designed consisting of a movable indexed slide board with an Exact Lok-Bar drilled into it. A Timo headrests were used fixate the head of the patient relative to the slide board. For the Varian Exact Couch™, the immobilization board was connected to the H3 notch to avoid the metal infrastructure of the couch for the delivery of the mantle and spleen fields. For tall patients the required shift for the pelvis isocenter reaches the shifting limit and the board was slid from H3 to H4 (a fixed distance of 14 cm). A total 22 patients were stratified in two groups of 11, one consisting of the conventional setup, and one group with the proposed immobilization technique. Results: The standard deviations (SD) of the couch positions in lateral, longitudinal, and vertical directions for 10 fractions for each patient in both groups were calculated. In the non-indexed group, the positioning SD ranged from 0.9 to 4.7 cm. Using our device, the positioning SD was reduced to a range of 0.2 to 0.9 cm, with the longitudinal direction showing the largest improvement. Conclusion: Matched field TLI remains error prone to geometrical misses. The feasibility of full indexing TLI treatments was validated and shown to result in a significant reduction of positioning errors.

60 APPLIED LIFE SCIENCES↗

An improved far field drag calculation method for nonlinear CFD codes

An improved method to calculate drag based on far field conditions is presented and demonstrated. The method is illustrated using two CFD codes, PARC and CFL3D, and examining their ability to preserve lift and drag coefficients along grid line defined integration paths. The flow fields were generated by solving the Euler equations for a NACA 0012 airfoil at a free stream Mach number of 0.8 and angle of attack of 1.25 degrees. In comparison to force coefficients obtained by surface pressure integration, neither code acceptably preserved both force coefficients throughout the near and far fields. An investigation into the relationship between numerical prediction error and calculated force coefficients revealed a direct connection between solution mass conservation error and force coefficients error. A method to correct the predicted force coefficients based on integrated mass conservation error is described and demonstrated. The corrected force coefficients for both codes are shown to be more accurate than the uncorrected values. The correction method is applicable to both two and three dimensions and is independent of the algorithm used to generate the flow field.

Sirbaugh, James R.↗

On the Retrieval and Analysis of Multilevel Clouds

An accurate satellite retrieval of cloud properties depends upon the detection and analysis of multilayered, overlapping cloud systems that surface observations show to be common. Multiple cloud layers are often found, for instance, in frontal situations, where cirrus overlays boundary layer convective cloud or low-to mid-level stratus cloud. Surface observers (Hahan et al., 1982) indicate that over ocean in the Northern Hemisphere between 30 deg. N and 60 deg. N, 51 percent of observations are of multilevel clouds. A satellite analysis by Coakley (1983) over the Pacific Ocean finds that more than 50 percent of 500 (250 sq km) frames exhibit evidence of multilayered cloud systems. The questions addressed in this study are the following: What error is introduced when inferring the cloud pressure from a Field-Of-View (FOV) that contains some arbitrary amount of transparent cloud overlaying a lower-level black cloud, such as stratus, by making the assumption that there is only a single cloud layer in the FOV, and what may be done to improve the cloud retrieval? The CO2 slicing methods (e.g. McCleese and Wilson, 1976; Smith and Platt, 1978; Chahine, 1974) have been shown to provide accurate means of inferring cirrus cloud altitude from passive infrared radiance measurements. The CO2 techniques have been applied to radiometric data from several instruments, notably the High Resolution Infrared Radiometric Sounder (HIRS/2, hereafter referred to as HIRS), the VISSR Atmospheric Sounder (VAS) (e.g., Menzel et al., 1983; Wylie and Menzel, 1989), and most recently to the High Resolution Interferometer Sounder (HIS) (Smith and Frey, 1990). The methods take advantage of the fact that infrared CO2 sounding channels spaced closely in wavenumber each have varying opacity to CO2, thereby causing each channel to be sensitive to a different level in the atmosphere. The techniques have been shown to be effective for single-layered, nonblack, mid- to high-level clouds such as cirrus, but are generally applied operationally to any given cloud occurrence. The CO2 slicing algorithms are most accurate for clouds than occur in a single, well-defined layer, or for multi-layered cloud cases in which the uppermost cloud layer is nearly black. Significant cloud height retrieval errors may ensue if the HIRS Field-Of-View (FOV) is cotaminated with low cloud. McCleese and Wilson (1976) have shown that the retrieved cloud height for the case of multiple cloud layers is a weighted average of the cloud heights actually present. The weight is approximately proportional to the product of the cloud heigt and the effective cloud amount. The effect of their result is that the uppermost cloud layer dominates the cloud pressure retrieval. Beyond stating that the higher cloud dominates the cloud pressure retrieval, there is no quantitative information to provide a way of estimating the errors in cloud pressure retrieval one should expect for certain common multilevel cloud situations or any suggestions on how to reduce the errors. In this paper we estimate the magnitude of the errors and use a simple algorithm to reduce the errors in optically thin cloud height retrival.

Baum, Bryan A.↗

Visual field information in Nap-of-the-Earth flight by teleoperated Helmet-Mounted displays

The human ability to derive Control-Oriented Visual Field Information from teleoperated Helmet-Mounted displays in Nap-of-the-Earth flight, is investigated. The visual field with these types of displays originates from a Forward Looking Infrared Radiation Camera, gimbal-mounted at the front of the aircraft and slaved to the pilot's line-of-sight, to obtain wide-angle visual coverage. Although these displays are proved to be effective in Apache and Cobra helicopter night operations, they demand very high pilot proficiency and work load. Experimental work presented in the paper has shown that part of the difficulties encountered in vehicular control by means of these displays can be attributed to the narrow viewing aperture and head/camera slaving system phase lags. Both these shortcomings will impair visuo-vestibular coordination, when voluntary head rotation is present. This might result in errors in estimating the Control-Oriented Visual Field Information vital in vehicular control, such as the vehicle yaw rate or the anticipated flight path, or might even lead to visuo-vestibular conflicts (motion sickness). Since, under these conditions, the pilot will tend to minimize head rotation, the full wide-angle coverage of the Helmet-Mounted Display, provided by the line-of-sight slaving system, is not always fully utilized.

Grunwald, Arthur J.↗

Reducing Disk Storage of Full-3D Seismic Waveform Tomography (F3DT) Through Lossy Online Compression

Full-3D seismic waveform tomography (F3DT) is the latest seismic tomography technique that can assimilate broadband, multi-component seismic waveform observations into high-resolution 3D subsurface seismic structure models. The main drawback in the current F3DT implementation, in particular the scattering-integral implementation (F3DT-SI), is the high disk storage cost and the associated I/O overhead of archiving the 4D space-time wavefields of the receiver- or source-side strain tensors. The strain tensor fields are needed for computing the data sensitivity kernels, which are used for constructing the Jacobian matrix in the Gauss-Newton optimization algorithm. In this study, we have successfully integrated a lossy compression algorithm into our F3DT SI workflow to significantly reduce the disk space for storing the strain tensor fields. The compressor supports a user-specified tolerance for bounding the error, and can be integrated into our finite-difference wave-propagation simulation code used for computing the strain fields. The decompressor can be integrated into the kernel calculation code that reads the strain fields from the disk and compute the data sensitivity kernels. During the wave-propagation simulations, we compress the strain fields before writing them to the disk. To compute the data sensitivity kernels, we read the compressed strain fields from the disk and decompress them before using them in kernel calculations. Experiments using a realistic dataset in our California statewide F3DT project have shown that we can reduce the strain-field disk storage by at least an order of magnitude with acceptable loss, and also improve the overall I/O performance of the entire F3DT-SI workflow significantly. The integration of the lossy online compressor may potentially open up the possibilities of the wide adoption of F3DT-SI in routine seismic tomography practices in the near future.

97 MATHEMATICS AND COMPUTING↗

Simulation study of geometric shape factor approach to estimating earth emitted flux densities from wide field-of-view radiation measurements

A study was performed on the use of geometric shape factors to estimate earth-emitted flux densities from radiation measurements with wide field-of-view flat-plate radiometers on satellites. Sets of simulated irradiance measurements were computed for unrestricted and restricted field-of-view detectors. In these simulations, the earth radiation field was modeled using data from Nimbus 2 and 3. Geometric shape factors were derived and applied to these data to estimate flux densities on global and zonal scales. For measurements at a satellite altitude of 600 km, estimates of zonal flux density were in error 1.0 to 1.2%, and global flux density errors were less than 0.2%. Estimates with unrestricted field-of-view detectors were about the same for Lambertian and non-Lambertian radiation models, but were affected by satellite altitude. The opposite was found for the restricted field-of-view detectors.

Weaver, W. L.↗

Performance analysis of a cascaded coding scheme with interleaved outer code

A cascaded coding scheme for a random error channel with a bit-error rate is analyzed. In this scheme, the inner code C sub 1 is an (n sub 1, m sub 1l) binary linear block code which is designed for simultaneous error correction and detection. The outer code C sub 2 is a linear block code with symbols from the Galois field GF (2 sup l) which is designed for correcting both symbol errors and erasures, and is interleaved with a degree m sub 1. A procedure for computing the probability of a correct decoding is presented and an upper bound on the probability of a decoding error is derived. The bound provides much better results than the previous bound for a cascaded coding scheme with an interleaved outer code. Example schemes with inner codes ranging from high rates to very low rates are evaluated. Several schemes provide extremely high reliability even for very high bit-error rates say 10 to the -1 to 10 to the -2 power.

Lin, S.↗