Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors and uncertainties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Improved Analysis of GW150914 Using a Fully Spin-Precessing Waveform Model

This paper presents updated estimates of source parameters for GW150914, a binary black-hole coalescence event detected by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 [Abbott et al. Phys. Rev. Lett. 116, 061102 (2016).]. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] presented parameter estimation of the source using a 13-dimensional, phenomenological precessing-spin model (precessing IMRPhenom) and an 11-dimensional nonprecessing effective-one-body (EOB) model calibrated to numerical-relativity simulations, which forces spin alignment (nonprecessing EOBNR). Here, we present new results that include a 15-dimensional precessing-spin waveform model (precessing EOBNR) developed within the EOB formalism. We find good agreement with the parameters estimated previously [Abbott et al. Phys. Rev. Lett. 116, 241102 (2016).], and we quote updated component masses of 35(+5)(-3) solar M; and 30(+3)(-4) solar M; (where errors correspond to 90 symmetric credible intervals). We also present slightly tighter constraints on the dimensionless spin magnitudes of the two black holes, with a primary spin estimate is less than 0.65 and a secondary spin estimate is less than 0.75 at 90% probability. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] estimated the systematic parameter-extraction errors due to waveform-model uncertainty by combining the posterior probability densities of precessing IMRPhenom and nonprecessing EOBNR. Here, we find that the two precessing-spin models are in closer agreement, suggesting that these systematic errors are smaller than previously quoted.

Abbott, B. P.↗

Formaldehyde Distribution over North America: Implications for Satellite Retrievals of Formaldehyde Columns and Isoprene Emission

Formaldehyde (HCHO) columns measured from space provide constraints on emissions of volatile organic compounds (VOCs). Quantitative interpretation requires characterization of errors in HCHO column retrievals and relating these columns to VOC emissions. Retrieval error is mainly in the air mass factor (AMF) which relates fitted backscattered radiances to vertical columns and requires external information on HCHO, aerosols, and clouds. Here we use aircraft data collected over North America and the Atlantic to determine the local relationships between HCHO columns and VOC emissions, calculate AMFs for HCHO retrievals, assess the errors in deriving AMFs with a chemical transport model (GEOS-Chem), and draw conclusions regarding space-based mapping of VOC emissions. We show that isoprene drives observed HCHO column variability over North America; HCHO column data from space can thus be used effectively as a proxy for isoprene emission. From observed HCHO and isoprene profiles we find an HCHO molar yield from isoprene oxidation of 1.6 +/- 0.5, consistent with current chemical mechanisms. Clouds are the primary error source in the AMF calculation; errors in the HCHO vertical profile and aerosols have comparatively little effect. The mean bias and 1Q uncertainty in the GEOS-Chem AMF calculation increase from <1% and 15% for clear skies to 17% and 24% for half-cloudy scenes. With fitting errors, this gives an overall 1 Q error in HCHO satellite measurements of 25-31%. Retrieval errors, combined with uncertainties in the HCHO yield from isoprene oxidation, result in a 40% (1sigma) error in inferring isoprene emissions from HCHO satellite measurements.

Millet, Dylan B.↗

FRAM Version 6.1’s Bias

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. For FRAM version 4 and earlier, the reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. We did several studies with FRAM v.4 and found that FRAM’s statistical precision can be reasonably represented by its reported uncertainties. FRAM’s biases or systematic uncertainties can come from a variety of sources and can be difficult to determine. For FRAM version 5, we carefully examined the FRAM analytical results of both the archival plutonium data and the data specifically acquired for the isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We then worked out the equations representing the biases of the measured isotopes from each measurement using internal spectral parameters, such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). The resulting biases were included in the reported uncertainties of FRAM v.5. For the upcoming FRAM version 6.1, we are doing the same study that we did for FRAM v.5. The resulting biases will be included in its reported uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FRAM Version 7.1’s Bias

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. For FRAM versions 4 and earlier, the reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. For FRAM versions 5 and 6, we examined the FRAM analytical results of both the archival plutonium data and the data specifically acquired for the isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We worked out the equations representing the biases of the measured isotopes from each measurement using internal spectral parameters, such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). The resulting biases were included in the reported uncertainties of FRAM v.5 and v.6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Ages and Masses of a Million Galactic-disk Main-sequence Turnoff and Subgiant Stars from the LAMOST Galactic Spectroscopic Surveys

We present estimates of stellar age and mass for 0.93 million Galactic-disk main-sequence turnoff and subgiant stars from the LAMOST Galactic Spectroscopic Surveys. The ages and masses are determined by matching with stellar isochrones using a Bayesian algorithm, utilizing effective temperature T{sub eff}, absolute magnitude M{sub V}, metallicity [Fe/H], and α-element to iron abundance ratio [α/Fe] deduced from the LAMOST spectra. Extensive examinations suggest the age and mass estimates are robust. Overall, the sample stars have a median error of 34% for the age estimates, and half of the stars older than 2 Gyr have age uncertainties of only 20%–30%. The median error for the mass estimates of the whole sample of stars is ∼8%. The huge data set demonstrates good correlations among stellar age, [Fe/H] ([α/H]), and [α/Fe]. Particularly, double-sequence features are revealed in both the age–[α/Fe] and age–[Fe/H]([α/H]) spaces. In the [Fe/H]–[α/Fe] space, stars of 8–10 Gyr exhibit both the thin and thick disk sequences, while younger (older) stars show only the thin (thick) disk sequence, indicating that the thin disk became prominent 8–10 Gyr ago, while the thick disk formed earlier and was almost quenched 8 Gyr ago. Stellar ages exhibit positive vertical and negative radial gradients across the disk, and the outer disk of R ≳ 9 kpc exhibits a strong flare in stellar age distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Gauging Metallicity of Diffuse Gas under an Uncertain Ionizing Radiation Field

Gas metallicity is a key quantity used to determine the physical conditions of gaseous clouds in a wide range of astronomical environments, including interstellar and intergalactic space. In particular, considerable effort in circumgalactic medium (CGM) studies focuses on metallicity measurements because gas metallicity serves as a critical discriminator for whether the observed heavy ions in the CGM originate in chemically enriched outflows or in more chemically pristine gas accreted from the intergalactic medium. However, because the gas is ionized, a necessary first step in determining CGM metallicity is to constrain the ionization state of the gas which, in addition to gas density, depends on the ultraviolet background radiation field (UVB). While it is generally acknowledged that both the intensity and spectral slope of the UVB are uncertain, the impact of an uncertain spectral slope has not been properly addressed in the literature. This Letter shows that adopting a different spectral slope can result in an order of magnitude difference in the inferred CGM metallicity. Specifically, a harder UVB spectrum leads to a higher estimated gas metallicity for a given set of observed ionic column densities. Therefore, such systematic uncertainties must be folded into the error budget for metallicity estimates of ionized gas. An initial study shows that empirical diagnostics are available for discriminating between hard and soft ionizing spectra. Applying these diagnostics helps reduce the systematic uncertainties in CGM metallicity estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Quantification for Empirical X-59 Sonic Boom Loudness Levels

Estimates of the total uncertainty for empirically determined loudness levels are documented when GRS (Ground Recording System) noise monitors are used to record X 59 sonic boom waveforms. The total uncertainty is characterized by combining nine different sources of uncertainty that may affect the apparent gain of the measurement chain. These uncertainty estimates are presented as expected measurement error relative to the true loudness level, and separate error estimates are provided for eight different noise metrics in which NASA has interest. The behavior of the Perceived Level (PL) metric is studied within the report body, while the total uncertainties for the seven other noise metrics are summarized in appendices for brevity. The effects of four sources of uncertainty are estimated simply from information found on hardware specification sheets provided by the manufacturer. However, mock acoustic recordings are created to estimate the effects of other sources because those effects are expected to induce spectral coloration, so they may vary with noise metric type and sound level. These sources are not well modeled by simple gain adjustments. Importantly, measurement error is computable when processing mock recordings since the true levels are knowable, which is not the case when processing data recorded in the field. Specifically, the true levels are knowable because the components of the mock recordings are separable – e.g., loudness levels of booms can be computed with or without superimposed background noise. Mock acoustic recordings also have the benefit of allowing analysis of sonic booms from vehicles that are not yet flying, like the X-59, since the mock recordings are created by combining vehicle-specific predicted waveforms with other audio sources. The estimates of total measurement error are documented as a function of the signal-to-noise ratio (SNR) of the loudness level, where the corrected SNR is computed while accounting for the effects of the method that is used to correct for background noise contamination when computing the noise metric values. The corrected SNR calculations used here can be applied to both mock recordings and in-field measurements, so the uncertainty of in-field recordings can be found using pre-computed lookup tables that identify the relationship between metric type, corrected SNR, and the expected measurement error.

Sonic Boom↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A FLUX SCALE FOR SOUTHERN HEMISPHERE 21 cm EPOCH OF REIONIZATION EXPERIMENTS

We present a catalog of spectral measurements covering a 100-200 MHz band for 32 sources, derived from observations with a 64 antenna deployment of the Donald C. Backer Precision Array for Probing the Epoch of Reionization (PAPER) in South Africa. For transit telescopes such as PAPER, calibration of the primary beam is a difficult endeavor and errors in this calibration are a major source of error in the determination of source spectra. In order to decrease our reliance on an accurate beam calibration, we focus on calibrating sources in a narrow declination range from –46° to –40°. Since sources at similar declinations follow nearly identical paths through the primary beam, this restriction greatly reduces errors associated with beam calibration, yielding a dramatic improvement in the accuracy of derived source spectra. Extrapolating from higher frequency catalogs, we derive the flux scale using a Monte Carlo fit across multiple sources that includes uncertainty from both catalog and measurement errors. Fitting spectral models to catalog data and these new PAPER measurements, we derive new flux models for Pictor A and 31 other sources at nearby declinations; 90% are found to confirm and refine a power-law model for flux density. Of particular importance is the new Pictor A flux model, which is accurate to 1.4% and shows that between 100 MHz and 2 GHz, in contrast with previous models, the spectrum of Pictor A is consistent with a single power law given by a flux at 150 MHz of 382 ± 5.4 Jy and a spectral index of –0.76 ± 0.01. This accuracy represents an order of magnitude improvement over previous measurements in this band and is limited by the uncertainty in the catalog measurements used to estimate the absolute flux scale. The simplicity and improved accuracy of Pictor A's spectrum make it an excellent calibrator in a band important for experiments seeking to measure 21 cm emission from the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion

Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed by geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of prostate D90. The average error of 1.3mm with our system outperforms the CT-based approach and is considered well within the clinically acceptable limit. Supported in part by NIH/NCI grant 5R01CA151395. The X-ray-based implant reconstruction method (US patent No. 8,233,686) was licensed to Acoustic MedSystems Inc.

60 APPLIED LIFE SCIENCES↗

Vacuum-ultraviolet absorption cross-sections of functionalized four-carbon species

Absorption cross-sections were measured in the vacuum ultraviolet from 5.17 – 9.92 eV using differential absorption spectroscopy for 33 four-carbon species: n-butane, trans-2-butene, cis-2-butene, butanal, butyric acid, ethyloxirane, trans-2,3-dimethyloxirane, cis-2,3-dimethyloxirane, 2-methyloxetane, 2,2'-bioxirane, vinyl oxirane, 3,4-epoxybutan-2-one, diacetyl, diethyl ether, ethyl vinyl ether, vinyl acetate, acetic anhydride, 1-butanol, 3-buten-1-ol, 1–hydroxy-butan-2-one, 1–hydroxy-butan-3-one, 2,3-epoxybutan-1-ol, 3,4-epoxybutan-1-ol, 2-oxetanemethanol, butanone, methyl vinyl ketone, 4H-1,3-dioxine, allyl formate, 2-oxobutanal, 4-hydroxybutanal, 2-methyloxetan-3-one, cis–but-2-en-1-ol, and trans-2–but-enal. Uncertainties were quantified in all cases by accounting for errors in gas-phase concentration, experimental repeatability, and signal-to-noise ratio as a function of photon energy. With the exception of 2-oxobutanal, which is reported with an uncertainty of 10%, convolving the sources of error using the root-sum-square method led to an upper limit of 5% uncertainty above the detection limit, which is largely attributable to chemical purity. Here, the primary objective of the present work is to provide absolute cross-sections along with quantified uncertainty limits. The majority of the absorption spectra, which reflect electronic transitions such as σ → σ* and n → σ*, are reported for the first time and provide insight into fundamental chemical physics, such as vibrational band structure and Rydberg transitions. The quantitative spectra in the present work facilitates the discovery of chemical intermediates that support improvement in the accuracy of computational models for low-temperature combustion and atmospheric chemistry.

biofuels↗

Propagation of Noise Uncertainty Through Virtual Strain Gauge Formulations for 2D Digital Image Correlation

The effect of displacement uncertainty is examined on 2-dimensional strain, calculated using linear surfaces fitted to the displacement field. A classical engineering error propagation method is used to calculate uncertainty in Green-Lagrangian strain calculations. The derived uncertainty is compared to a Monte Carlo simulation and discrepancies under 2% are seen between these two methods. The effect of virtual strain gauge size, displacement uncertainty, and boundaries on the region of interest on the strain uncertainty are considered. Here, an exponential decay relationship is observed between strain uncertainty and virtual strain gauge size, while a linear relationship is seen between strain and displacement uncertainty. For boundaries in the region of interest, strain uncertainty is affected by the reduced number of points available to perform the regression.

42 ENGINEERING↗

Weak-lensing mass calibration of redMaPPer galaxy clusters in Dark Energy Survey Science Verification data

We use weak-lensing shear measurements to determine the mean mass of optically selected galaxy clusters in Dark Energy Survey Science Verification data. In a blinded analysis, we split the sample of more than 8,000 redMaPPer clusters into 15 subsets, spanning ranges in the richness parameter $5 \leq \lambda \leq 180$ and redshift $0.2 \leq z \leq 0.8$, and fit the averaged mass density contrast profiles with a model that accounts for seven distinct sources of systematic uncertainty: shear measurement and photometric redshift errors; cluster-member contamination; miscentering; deviations from the NFW halo profile; halo triaxiality; and line-of-sight projections. We combine the inferred cluster masses to estimate the joint scaling relation between mass, richness and redshift, $\mathcal{M}(\lambda,z) \varpropto M_0 \lambda^{F} (1+z)^{G}$. We find $M_0 \equiv \langle M_{200\mathrm{m}}\,|\,\lambda=30,z=0.5\rangle=\left[ 2.35 \pm 0.22\ \rm{(stat)} \pm 0.12\ \rm{(sys)} \right] \cdot 10^{14}\ M_\odot$, with $F = 1.12\,\pm\,0.20\ \rm{(stat)}\, \pm\, 0.06\ \rm{(sys)}$ and $G = 0.18\,\pm\, 0.75\ \rm{(stat)}\, \pm\, 0.24\ \rm{(sys)}$. The amplitude of the mass-richness relation is in excellent agreement with the weak-lensing calibration of redMaPPer clusters in SDSS by Simet et al. (2016) and with the Saro et al. (2015) calibration based on abundance matching of SPT-detected clusters. Our results extend the redshift range over which the mass-richness relation of redMaPPer clusters has been calibrated with weak lensing from $z\leq 0.3$ to $z\leq0.8$. Calibration uncertainties of shear measurements and photometric redshift estimates dominate our systematic error budget and require substantial improvements for forthcoming studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity analysis is a widely used technique in international safeguards and is most commonly applied to the assay of product and scrap materials in the production of mixed oxide fuel. The typical neutron multiplicity analysis applies only a crude, almost cursory, uncertainty analysis limited to propagation of statistical errors in the derived singles, doubles, and triples count rates through the point source model. While these analyses do not account for uncertainties in basic detector parameters (e.g., efficiency or gate utilization factors), nuclear data, or covariances between any of these values, measurement uncertainties are often quoted in the range of 1–2% of the resulting mass values. In this work, we examined the impact of the nuclear data and instrumentation uncertainties on the multiplicity assay result for various counting regimes using the point-model equations as the basis for discussion. Potential biases introduced by the current nuclear data set on the measurement and the need for a more complete error treatment when we progress beyond empirical calibrations based on highly representative items will be discussed.

Mcelroy Jr, Robert↗

Robustness of channel-adapted quantum error correction

A quantum channel models the interaction between the system we are interested in and its environment. Such a model can capture the main features of the interaction, but, because of the complexity of the environment, we cannot assume that it is fully accurate. We study the robustness of quantum error correction operations against completely unexpected and subsequently undetermined type of channel uncertainties. We find that a channel-adapted optimal error correction operation does not only give the best possible channel fidelity but it is more robust against channel alterations than any other error correction operation. Our results are valid for Pauli channels and stabilizer codes, but based on some numerical results, we believe that very similar conclusions can be drawn also in the general case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Joint Seasonal ARMA Approach for Modeling of Load Forecast Errors in Planning Studies

To make informed and robust decisions in the probabilistic power system operation and planning process, it is critical to conduct multiple simulations of the generated combinations of wind and load parameters and their forecast errors to handle the variability and uncertainty of these time series. In order for the simulation results to be trustworthy, the simulated series must preserve the salient statistical characteristics of the real series. In this paper, we analyze day-ahead load forecast error data from multiple balancing authority locations and characterize statistical properties such as mean, standard deviation, autocorrelation, correlation between series, time-of-day bias, and time-of-day autocorrelation. We then construct and validate a seasonal autoregressive moving average (ARMA) model to model these characteristics, and use the model to jointly simulate day-ahead load forecast error series for all BAs.

Power system planning, Operations, Probabilistic m↗

Astrophysical limitations to the identification of dark matter: Indirect neutrino signals vis-a-vis direct detection recoil rates

A convincing identification of dark matter (DM) particles can probably be achieved only through a combined analysis of different detections strategies, which provides an effective way of removing degeneracies in the parameter space of DM models. In practice, however, this program is made complicated by the fact that different strategies depend on different physical quantities, or on the same quantities but in a different way, making the treatment of systematic errors rather tricky. We discuss here the uncertainties on the recoil rate in direct-detection experiments and on the muon rate induced by neutrinos from dark matter annihilations in the Sun, and we show that, contrarily to the local DM density or overall cross section scale, irreducible astrophysical uncertainties affect the two rates in a different fashion, therefore limiting our ability to reconstruct the parameters of the dark matter particles. By varying within their respective errors astrophysical parameters such as the escape velocity and the velocity dispersion of dark matter particles, we show that the uncertainty on the relative strength of the neutrino and direct-detection signal is as large as a factor of 2 for typical values of the parameters, but can be even larger in some circumstances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Destructive Assay (NDA) Uncertainties Impact on Physical Inventory Difference (ID) and Material Balance Determination: Sources of Error, Precision/Accuracy, and ID/Propagation of Error (POV)

These are slides from a presentation made by a researcher from Los Alamos National Laboratory. The following topics are covered: sources of error for NDA gamma measurements, precision and accuracy are two important characteristics of measurements, four items processed in a material balance area during the inventory time period, inventory difference and propagation of variance, sum in quadrature, and overview of the ID/POV process.

36 MATERIALS SCIENCE↗