Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Estimating the tensor-to-scalar ratio and the effect of residual foreground contamination

We consider future balloon-borne and ground-based suborbital experiments designed to search for inflationary gravitational waves, and investigate the impact of residual foregrounds that remain in the estimated cosmic microwave background maps. This is achieved by propagating foreground modelling uncertainties from the component separation, under the assumption of a spatially uniform foreground frequency scaling, through to the power spectrum estimates, and up to measurement of the tensor to scalar ratio in the parameter estimation step. We characterize the error covariance due to subtracted foregrounds, and find it to be subdominant compared to instrumental noise and sample variance in our simulated data analysis. We model the unsubtracted residual foreground contribution using a two-parameter power law and show that marginalization over these foreground parameters is effective in accounting for a bias due to excess foreground power at low l. We conclude that, at least in the suborbital experimental setups we have simulated, foreground errors may be modeled and propagated up to parameter estimation with only a slight degradation of the target sensitivity of these experiments derived neglecting the presence of the foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

Inferring the Joint Demographic History of Multiple Populations from Multidimensional SNP Frequency Data

Demographic models built from genetic data play important roles in illuminating prehistorical events and serving as null models in genome scans for selection. We introduce an inference method based on the joint frequency spectrum of genetic variants within and between populations. For candidate models we numerically compute the expected spectrum using a diffusion approximation to the one-locus, two-allele Wright-Fisher process, involving up to three simultaneous populations. Our approach is a composite likelihood scheme, since linkage between neutral loci alters the variance but not the expectation of the frequency spectrum. We thus use bootstraps incorporating linkage to estimate uncertainties for parameters and significance values for hypothesis tests. Our method can also incorporate selection on single sites, predicting the joint distribution of selected alleles among populations experiencing a bevy of evolutionary forces, including expansions, contractions, migrations, and admixture. We model human expansion out of Africa and the settlement of the New World, using 5 Mb of noncoding DNA resequenced in 68 individuals from 4 populations (YRI, CHB, CEU, and MXL) by the Environmental Genome Project. We infer divergence between West African and Eurasian populations 140 thousand years ago (95% confidence interval: 40–270 kya). This is earlier than other genetic studies, in part because we incorporate migration. We estimate the European (CEU) and East Asian (CHB) divergence time to be 23 kya (95% c.i.: 17–43 kya), long after archeological evidence places modern humans in Europe. Finally, we estimate divergence between East Asians (CHB) and Mexican-Americans (MXL) of 22 kya (95% c.i.: 16.3–26.9 kya), and our analysis yields no evidence for subsequent migration. Furthermore, combining our demographic model with a previously estimated distribution of selective effects among newly arising amino acid mutations accurately predicts the frequency spectrum of nonsynonymous variants across three continental populations (YRI, CHB, CEU).

59 BASIC BIOLOGICAL SCIENCES↗

A multi-frequency radiometric measurement of soil moisture content over bare and vegetated fields

A USDA Beltsville Agricultural Research Center site was used for an experiment in which soil moisture remote sensing over bare, grass, and alfalfa fields was conducted over a three-month period using 0.6 GHz, 1.4 GHz, and 10.6 GHz Dicke-type microwave radiometers mounted on mobile towers. Ground truth soil moisture content and ambient air and sil temperatures were obtained concurrently with the radiometric measurements. Biomass of the vegetation cover was sampled about once a week. Soil density for each of the three fields was measured several times during the course of the experiment. Results of the radiometric masurements confirm the frequency dependence of moisture sensing sensitivity reduction reported earlier. Observations over the bare, wet field show that the measured brightness temperature is lowest at 5.0 GHz and highest of 0.6 GHz frequency, a result contrary to expectation based on the estimated dielectric permittivity of soil water mixtures and current radiative transfer model in that frequency range.

Wang, J. R.↗

Altimetry for non-Gaussian oceans - Height biases and estimation of parameters

The effects of a non-Gaussian ocean on satellite altimetry parameter estimation are discussed. The first part of this paper shows how non-Gaussian ocean parameters affect height estimation for satellites of the Seasat/Geosat/TOPEX type. In the second part, the estimation of the altimeter tracker bias and the non-Gaussian ocean parameters from the altimeter return signal is studied. A new convolution model that facilitates the deconvolution of the ocean surface specular point probability density function is introduced. Next, it is argued that it is not feasible in practice to estimate the electromagnetic bias from noisy altimeter returns. It is then shown that the least squares estimation of the surface parameters in the log-frequency domain has several advantages overestimating parameters in the time domain. The maximum likelihood estimation equations for the estimation of the waveform parameters are derived, and their solution is discussed.

Rodriguez, Ernesto↗

Power system inertia estimation: Review of methods and the impacts of converter-interfaced generations

Understanding and quantifying the inertia of power systems with the integration of converter-interfaced generation (CIG) plays an essential role in the safe transition to a future low-inertia scenario. Here we provide a comprehensive summary of inertia definitions for both synchronous generators and CIGs as well as their corresponding estimation methods. In particular, the estimation methods are categorized as model-based and measurement-based approaches considering both small and large disturbances. The advantages and disadvantages of different methods are carefully discussed. This paper also offers for the first time a framework to quantify the virtual inertia of CIGs at the component and aggregation levels, an open problem in the literature. Finally, future directions for inertia estimation are identified and discussed. This significantly benefits the design of appropriate control and protection schemes in achieving a more reliable, secure, and resilient power system.

42 ENGINEERING↗

Adaptive Linear State Estimation for Unbalanced Distribution System

The inclusion of PMU functionality in distribution relays enables the implementation of a linear state estimator (LSE) in Distribution Systems (DS). However, the unbalanced topology and phase coupling in distribution lines necessitate modifications to the LSE formulation. Additionally, the higher fault frequency in distribution systems requires a state estimation approach that is resilient to contingencies. This work proposes an adaptive linear state estimation algorithm tailored for unbalanced distribution systems with single-phase and two-phase laterals. Furthermore, a modified Optimal PMU Placement (OPP) strategy is introduced to ensure full observability in distribution systems with single-phase and two-phase buses. To maintain adaptability to topology changes, the state estimator incorporates circuit breaker status data provided by PMUs, ensuring robust performance during topology changes triggered by faults. The performance of the algorithm is verified on the IEEE 13-bus, 34-bus, and 123-bus systems.

PMUs↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Estimating radiated power from a conducting tethered satellite system

In anticipation of the upcoming TSS-1 experiment, theoretical calculations are made of radiated power from a conducting tethered satellite system. The radiation results from the steady motion of the system through the ionospheric plasma and it is stimulated by collection and emission of charge by the noninsulated surfaces of the tethered end connectors. A model of the current system is developed which incorporates the tether wire, satellite surfaces, and sheath currents. The radiation impedance of the current model is calculated using the previously developed theory of Barnett and Olbert (1986). The results confirm the low-frequency Alfven wave description with a predicted radiation impedance of a few tenths of an ohm in the Alven wave limit. Calculations are also made in the lower hybrid and whistler wave band. A larger impedance of about 13 ohm is found for the frequency range 5-50 kHz. By estimating the passive ion current drawn by the system a prediction of the total radiated power is also made. The result of 0.38 mW raises the question of whether or not wave emissions from a passive current collecting system may be detectable by either ground- or space-based platforms.

Donohue, D. J.↗

MAPPING THE SHORES OF THE BROWN DWARF DESERT. III. YOUNG MOVING GROUPS

We present the results of an aperture-masking interferometry survey for substellar companions around 67 members of the young ({approx}8-200 Myr) nearby ({approx}5-86 pc) AB Doradus, {beta} Pictoris, Hercules-Lyra, TW Hya, and Tucana-Horologium stellar associations. Observations were made at near-infrared wavelengths between 1.2 and 3.8 {mu}m using the adaptive optics facilities of the Keck II, Very Large Telescope UT4, and Palomar Hale Telescopes. Typical contrast ratios of {approx}100-200 were achieved at angular separations between {approx}40 and 320 mas, with our survey being 100% complete for companions with masses below {approx}0.25 M{sub Sun} across this range. We report the discovery of a 0.52 {+-} 0.09 M{sub Sun} companion to HIP 14807, as well as the detections and orbits of previously known stellar companions to HD 16760, HD 113449, and HD 160934. We show that the companion to HD 16760 is in a face-on orbit, resulting in an upward revision of its mass from M{sub 2}sin i {approx} 14 M{sub J} to M{sub 2} = 0.28 {+-} 0.04 M{sub Sun }. No substellar companions were detected around any of our sample members, despite our ability to detect companions with masses below 80 M{sub J} for 50 of our targets: of these, our sensitivity extended down to 40 M{sub J} around 30 targets, with a subset of 22 subject to the still more stringent limit of 20 M{sub J}. A statistical analysis of our non-detection of substellar companions allows us to place constraints on their frequency around {approx}0.2-1.5 M{sub Sun} stars. In particular, considering companion mass distributions that have been proposed in the literature, we obtain an upper limit estimate of {approx}9%-11% for the frequency of 20-80 M{sub J} companions between 3 and 30 AU at 95% confidence, assuming that their semimajor axes are distributed according to dN/da{proportional_to}a{sup -1} in this range.

79 ASTRONOMY AND ASTROPHYSICS↗

Russian national time scale long-term stability

The Institute of Metrology for Time and Space NPO 'VNIIFTRI' generates the National Time Scale (NTS) of Russia -- one of the most stable time scales in the world. Its striking feature is that it is based on a free ensemble of H-masers only. During last two years the estimations of NTS longterm stability based only on H-maser intercomparison data gives a flicker floor of about (2 to 3) x 10(exp -15) for averaging times from 1 day to 1 month. Perhaps the most significant feature for a time laboratory is an extremely low possible frequency drift -- it is too difficult to estimate it reliably. The other estimations, free from possible inside the ensemble correlation phenomena, are available based on the time comparison of NTS relative to the stable enough time scale of outer laboratories. The data on NTS comparison relative to the time scale of secondary time and frequency standards at Golitzino and Irkutsk in Russia and relative to NIST, PTB and USNO using GLONASS and GPS time transfer links gives stability estimations which are close to that based on H-maser intercomparisons.

Alshina, A. P.↗

Consistency of cosmic microwave background temperature measurements in three frequency bands in the 2500-square-degree SPT-SZ survey

We present an internal consistency test of South Pole Telescope (SPT) measurements of the cosmic microwave background (CMB) temperature anisotropy using three-band data from the SPT-SZ survey. These measurements are made from observations of ~ 2500 °2 of sky in three frequency bands centered at 95, 150, and 220 GHz. We combine the information from these three bands into six semi-independent estimates of the CMB power spectrum (three single-frequency power spectra and three cross-frequency spectra) over the multipole range 650<&ell;<3000. We subtract an estimate of foreground power from each power spectrum and evaluate the consistency among the resulting CMB-only spectra. We determine that the six foreground-cleaned power spectra are consistent with the null hypothesis, in which the six cleaned spectra contain only CMB power and noise. A fit of the data to this model results in a χ 2 value of 236.3 for 235 degrees of freedom, and the probability to exceed this χ 2 value is 46%.

79 ASTRONOMY AND ASTROPHYSICS↗

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

Combined Force-Frequency Sampling for Simulation of Systems Having Rugged Free Energy Landscapes.

An adaptive, machine learning-based sampling method is presented for simulation of systems having rugged, multidimensional free energy landscapes. The method's main strength resides in its ability to learn both from the frequency of visits to distinct states and the generalized force estimates that arise in a system as it evolves in phase space. This is accomplished by introducing a self-integrating artificial neural network, which generates an estimate of the free energy directly from its derivatives. The usefulness of the proposed combined approach is examined in the context of two concrete examples, namely, an alanine dipeptide molecule in water and a polymer diffusing through a narrow pore. This new method is found to be robust, faster, and more accurate than approaches that rely only on frequency-based or generalized force-based estimations. After combining the proposed approach with overfill protection and support for sparse data storage and training, the method is shown to be more effective than comparable, previously available techniques and capable of scaling efficiently to larger numbers of collective variables.

Sevgen, Emre↗

Coupled analysis of high and low frequency resonant ultrasound spectroscopy: Application to the detection of defects in ceramic balls

A coupled analysis of high and low frequency resonant ultrasound spectroscopy of spheroidal modes is presented in this paper. Experimentally, by using an ultrasonic probe for the excitation (piezoelectric transducer) and a heterodyne optic probe for the receiver (interferometer), it was possible to take spectroscopic measurements of spheroidal vibrations over a large frequency range of 100 kHz-45 MHz in a continuous regime. This wide analysis range enabled variations in velocity due to the presence of defects to be differentiated from the inherent characteristics of the balls and consequently, it offers the possibility of detecting cracks independently of production variations. This kind of defect is difficult to detect because the C-shaped surface crack is very small and narrow (500x5 {mu}m{sup 2}), and its depth does not exceed 50 {mu}m. The proposed methodology can excite spheroidal vibrations in the ceramic balls and detect such vibrations over a large frequency range. On the one hand, low frequency resonances are used in order to estimate the elastic coefficients of the balls according to various inspection depths. This method has the advantage of providing highly accurate evaluations of the elastic coefficients over a wide frequency range. On the other hand, high frequency vibrations are considered because they are similar to the surface waves propagating in the surface zone of the ceramic balls and consequently can be used to detect C-crack defects.

36 MATERIALS SCIENCE↗

SU-D-206-04: Iterative CBCT Scatter Shading Correction Without Prior Information

Purpose: To estimate and remove the scatter contamination in the acquired projection of cone-beam CT (CBCT), to suppress the shading artifacts and improve the image quality without prior information. Methods: The uncorrected CBCT images containing shading artifacts are reconstructed by applying the standard FDK algorithm on CBCT raw projections. The uncorrected image is then segmented to generate an initial template image. To estimate scatter signal, the differences are calculated by subtracting the simulated projections of the template image from the raw projections. Since scatter signals are dominantly continuous and low-frequency in the projection domain, they are estimated by low-pass filtering the difference signals and subtracted from the raw CBCT projections to achieve the scatter correction. Finally, the corrected CBCT image is reconstructed from the corrected projection data. Since an accurate template image is not readily segmented from the uncorrected CBCT image, the proposed scheme is iterated until the produced template is not altered. Results: The proposed scheme is evaluated on the Catphan©600 phantom data and CBCT images acquired from a pelvis patient. The result shows that shading artifacts have been effectively suppressed by the proposed method. Using multi-detector CT (MDCT) images as reference, quantitative analysis is operated to measure the quality of corrected images. Compared to images without correction, the method proposed reduces the overall CT number error from over 200 HU to be less than 50 HU and can increase the spatial uniformity. Conclusion: An iterative strategy without relying on the prior information is proposed in this work to remove the shading artifacts due to scatter contamination in the projection domain. The method is evaluated in phantom and patient studies and the result shows that the image quality is remarkably improved. The proposed method is efficient and practical to address the poor image quality issue of CBCT images. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

First Results of GPS Time Transfer to Australia

A global positioning system (GPS) time transfer unit was installed at Tidbinbilla Deep Space Communications Complex of the DSN in June 1983. It was used to estimate the relationship to UTC(USNO MC) of the Tidbinbilla frequency and time system TID(FTS) based on a hydrogen maser, and to estimate the performance of the Australian free-running time scale UTC(AUS). Data from the first 3 months were analyzed three ways: by two-hop common view using JPL as intermediary; by long-arc interpolation of measurements against space vehicle clocks; and by long arc interpolation of GPS-Time results. Residuals from a single quadratic fit through 3 months of UTC(USNO MC) -TID(FTS) results were white noise with standard error 15 ns, and a flying clock measurement gave 70 ns agreement. A straight line fit through results UTC(USNO MC) - UTC(AUS) gave 90 ns standard error and 120 ns agreement. It is proposed to use the GPS measurements to steer UTC(AUS) to UTC(BIH), and to rename the existing time scale TA(AUS).

Mck.luck, J.↗

Calcium titanate (CaTiO{sub 3}) dielectrics prepared by plasma spray and post-deposition thermal treatment

Highlights: • Calcium titanate was sprayed by two different plasma spray systems. • Significant improvement of dielectric properties after annealing was observed. • Calcium titanate self-supporting parts can be fabricated by plasma spraying. - Abstract: This paper studies calcium titanate (CaTiO{sub 3}) dielectrics prepared by plasma spray technology. A water stabilized plasma gun (WSP) as well as a widely used gas stabilized plasma gun (GSP) were employed in this study to deposit three sample sets at different spray conditions. Prepared specimens were annealed in air at atmospheric pressure for 2 h at various temperatures from 530 to 1170 °C. X-ray diffraction (XRD), Raman spectroscopy and porosity measurements were used for sample characterization. Dielectric spectroscopy was applied to obtain relative permittivity, conductivity and loss factor frequency dependence. Band gap energy was estimated from reflectance measurements. The work is focused on the explanation of changes in microstructure and properties of a plasma sprayed deposit after thermal annealing. Obtained results show significant improvement of dielectric properties after thermal annealing.

36 MATERIALS SCIENCE↗