Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Effects of excitation level on the stability of an axisymmetric mixing layer

The effect of various levels of excitation on the stability and development of an axisymmetric mixing layer was studied experimentally. The flow was excited axisymmetrically by a single speaker placed at the base of the plenum chamber. Measurements of mean and phase-averaged velocity profiles were made using an array of hot-wire probes. The measured profiles were compared to eigenfunctions calculated from linear, viscous stability theory. It is shown that the theoretical predictions, based on measured profiles of mean velocity, compare very well with the phase-averaged measurements, even when the local disturbance reaches levels as high as 24 percent of the jet speed. The cumulative effect of excitation on the mean flow is examined as a function of local Strouhal number as well as excitation level.

Samet, M. M.↗

Employment of CB models for non-linear dynamic analysis

The non-linear dynamic analysis of large structures is always very time, effort and CPU consuming. Whenever possible the reduction of the size of the mathematical model involved is of main importance to speed up the computational procedures. Such reduction can be performed for the part of the structure which perform linearly. Most of the time, the classical Guyan reduction process is used. For non-linear dynamic process where the non-linearity is present at interfaces between different structures, Craig-Bampton models can provide a very rich information, and allow easy selection of the relevant modes with respect to the phenomenon driving the non-linearity. The paper presents the employment of Craig-Bampton models combined with Newmark direct integration for solving non-linear friction problems appearing at the interface between the Hubble Space Telescope and its solar arrays during in-orbit maneuvers. Theory, implementation in the FEM code ASKA, and practical results are shown.

Klein, M. R. M.↗

An analysis of fiber-matrix interface failure stresses for a range of ply stress states

A graphite/bismaleimide laminate was prepared without the usual fiber treatment and was tested over a wide range of stress states to measure its ply cracking strength. These tests were conducted using off-axis flexure specimens and produced fiber-matrix interface failure data over a correspondingly wide range of interface stress states. The absence of fiber treatment, weakened the fiber-matrix interfaces and allowed these tests to be conducted at load levels that did not yield the matrix. An elastic micromechanics computer code was used to calculate the fiber-matrix interface stresses at failure. Two different fiber-array models (square and diamond) were used in these calculations to analyze the effects of fiber arrangement as well as stress state on the critical interface stresses at failure. This study showed that both fiber-array models were needed to analyze interface stresses over the range of stress states. A linear equation provided a close fit to these critical stress combinations and, thereby, provided a fiber-matrix interface failure criterion. These results suggest that prediction procedures for laminate ply cracking can be based on micromechanics stress analyses and appropriate fiber-matrix interface failure criteria. However, typical structural laminates may require elastoplastic stress analysis procedures that account for matrix yielding, especially for shear-dominated ply stress states.

Crews, J. H.↗

Deconvolution methods and systems for the mapping of acoustic sources from phased microphone arrays

A method and system for mapping acoustic sources determined from a phased microphone array. A plurality of microphones are arranged in an optimized grid pattern including a plurality of grid locations thereof. A linear configuration of N equations and N unknowns can be formed by accounting for a reciprocal influence of one or more beamforming characteristics thereof at varying grid locations among the plurality of grid locations. A full-rank equation derived from the linear configuration of N equations and N unknowns can then be iteratively determined. A full-rank can be attained by the solution requirement of the positivity constraint equivalent to the physical assumption of statically independent noise sources at each N location. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with the phased microphone array in order to compile an output presentation thereof, thereby removing the beamforming characteristics from the resulting output presentation.

Brooks, Thomas F.↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Mapping Spiking Neural Networks to Heterogeneous Crossbar Architectures using Integer Linear Programming

Advances in novel hardware devices and architectures allow Spiking Neural Network (SNN) evaluation using ultra-low power, mixed-signal, memristor crossbar arrays. As individual network sizes quickly scale beyond the dimensional capabilities of single crossbars, networks must be mapped onto multiple crossbars. Crossbar sizes within modern Memristor Crossbar Architectures (MCAs) are determined predominately not by device technology but by network topology; more, smaller crossbars consume less area thanks to the high structural sparsity found in larger, brain-inspired SNNs. Motivated by continuing increases in SNN sparsity due to improvements in training methods, we propose utilizing heterogeneous crossbar sizes to further reduce area consumption. This approach was previously unachievable as prior compiler studies only explored solutions targeting homogeneous MCAs. Our work improves on the state-of-the-art by providing Integer Linear Programming (ILP) formulations supporting arbitrarily heterogeneous architectures. By modeling axonal interactions between neurons, our methods produce better mappings while removing inhibitive a priori knowledge requirements. We first show a 16.7-27.6% reduction in area consumption for square-crossbar homogeneous architectures. Then, we demonstrate 66.9-72.7% further reduction when using a reasonable configuration of heterogeneous crossbar dimensions. Next, we present a new optimization formulation capable of minimizing the number of inter-crossbar routes. When applied to solutions already near-optimal in area, an 11.9-26.4% routing reduction is observed without impacting area consumption. Finally, we present a profile-guided optimization capable of minimizing the number of runtime spikes between crossbars. Compared to the best-area-then-route optimized solutions, we observe a further 0.5-14.8% inter-crossbar spike reduction while requiring 1–3 orders of magnitude less solver time.

Pohl, Devin [ORNL] (ORCID:0009000040149027)↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

LOW-FREQUENCY OBSERVATIONS OF LINEARLY POLARIZED STRUCTURES IN THE INTERSTELLAR MEDIUM NEAR THE SOUTH GALACTIC POLE

We present deep polarimetric observations at 154 MHz with the Murchison Widefield Array (MWA), covering 625 deg{sup 2} centered on α = 0{sup h}and δ = −27°. The sensitivity available in our deep observations allows an in-band, frequency-dependent analysis of polarized structure for the first time at long wavelengths. Our analysis suggests that the polarized structures are dominated by intrinsic emission but may also have a foreground Faraday screen component. At these wavelengths, the compactness of the MWA baseline distribution provides excellent snapshot sensitivity to large-scale structure. The observations are sensitive to diffuse polarized emission at ∼54′ resolution with a sensitivity of 5.9 mJy beam{sup −1} and compact polarized sources at ∼2.′4 resolution with a sensitivity of 2.3 mJy beam{sup −1} for a subset (400 deg{sup 2}) of this field. The sensitivity allows the effect of ionospheric Faraday rotation to be spatially and temporally measured directly from the diffuse polarized background. Our observations reveal large-scale structures (∼1°–8° in extent) in linear polarization clearly detectable in ∼2 minute snapshots, which would remain undetectable by interferometers with minimum baseline lengths of >110 m at 154 MHz. The brightness temperature of these structures is on average 4 K in polarized intensity, peaking at 11 K. Rotation measure synthesis reveals that the structures have Faraday depths ranging from −2 to 10 rad m{sup −2} with a large fraction peaking at approximately +1 rad m{sup −2}. We estimate a distance of 51 ± 20 pc to the polarized emission based on measurements of the in-field pulsar J2330–2005. We detect four extragalactic linearly polarized point sources within the field in our compact source survey. Based on the known polarized source population at 1.4 GHz and non-detections at 154 MHz, we estimate an upper limit on the depolarization ratio of 0.08 from 1.4 GHz to 154 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Principal Component Analysis of Up-The-Ramp Sampled Infrared Array Data

We describe the results of principal component analysis (PCA) of up-the-ramp sampled infrared (IR) array data from the Hubble Space Telescope wide field camera 3 (WFC3 IR), James Webb Space Telescope NIRSpec, and prototype Wide Field Infrared Survey Telescope’s wide field instrument detectors. These systems use, respectively, Teledyne H1R, H2RG, and H4RG-10 near-IR detector arrays with a variety of IR array controllers. The PCA shows that the Legendre polynomials approximate the principal components of these systems (i.e., they roughly diagonalize the covariance matrix). In contrast to the monomial basis that is widely used for polynomial fitting and linearization today, the Legendre polynomials are an orthonormal basis. They provide a quantifiable, compact, and (nearly) linearly uncorrelated representation of the information content of the data. By fitting a few Legendre polynomials, nearly all of the meaningful information in representative WFC3 astronomical datacubes can be condensed from 15 up-the-ramp samples down to 6 compressible Legendre coefficients per pixel. The higher order coefficients contain time domain information that is lost when one projects up-the-ramp sampled datacubes onto two-dimensional images by fitting a straight line, even if the data are linearized before fitting the line. Going forward, we believe that this time domain information is potentially important for disentangling the various nonlinearities that can affect IR array observations, i.e., inherent pixel nonlinearity, persistence, burn in, brighter-fatter effect, (potentially) nonlinear interpixel capacitance, and perhaps others.

Rauscher, Bernard J.↗

High-Speed Ionic Synaptic Memory Based on 2D Titanium Carbide MXene

Synaptic devices with linear high-speed switching can accelerate learning in artificial neural networks (ANNs) embodied in hardware. Conventional resistive memories however suffer from high write noise and asymmetric conductance tuning, preventing parallel programming of ANN arrays. Electrochemical random-access memories (ECRAMs), where resistive switching occurs by ion insertion into a redox-active channel, aim to address these challenges due to their linear switching and low noise. ECRAMs using 2D materials and metal oxides however suffer from slow ion kinetics, whereas organic ECRAMs enable high-speed operation but face challenges toward on-chip integration due to poor temperature stability of polymers. Here, ECRAMs using 2D titanium carbide (Ti 3 C 2 T x ) MXene that combine the high speed of organics and the integration compatibility of inorganic materials in a single high-performance device are demonstrated. These ECRAMs combine the speed, linearity, write noise, switching energy, and endurance metrics essential for parallel acceleration of ANNs, and importantly, they are stable after heat treatment needed for back-end-of-line integration with Si electronics. The high speed and performance of these ECRAMs introduces MXenes, a large family of 2D carbides and nitrides with more than 30 stoichiometric compositions synthesized to date, as promising candidates for devices operating at the nexus of electrochemistry and electronics.

2D materials↗

Linear encoding device

A Linear Motion Encoding device for measuring the linear motion of a moving object is disclosed in which a light source is mounted on the moving object and a position sensitive detector such as an array photodetector is mounted on a nearby stationary object. The light source emits a light beam directed towards the array photodetector such that a light spot is created on the array. An analog-to-digital converter, connected to the array photodetector is used for reading the position of the spot on the array photodetector. A microprocessor and memory is connected to the analog-to-digital converter to hold and manipulate data provided by the analog-to-digital converter on the position of the spot and to compute the linear displacement of the moving object based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Implementation and Assessment of Advanced Analog Vector-Matrix Processor

This paper discusses the design and implementation of an analog optical vecto-rmatrix coprocessor with a throughput of 128 Mops for a personal computer. Vector matrix calculations are inherently parallel, providing a promising domain for the use of optical calculators. However, to date, digital optical systems have proven too cumbersome to replace electronics, and analog processors have not demonstrated sufficient accuracy in large scale systems. The goal of the work described in this paper is to demonstrate a viable optical coprocessor for linear operations. The analog optical processor presented has been integrated with a personal computer to provide full functionality and is the first demonstration of an optical linear algebra processor with a throughput greater than 100 Mops. The optical vector matrix processor consists of a laser diode source, an acoustooptical modulator array to input the vector information, a liquid crystal spatial light modulator to input the matrix information, an avalanche photodiode array to read out the result vector of the vector matrix multiplication, as well as transport optics and the electronics necessary to drive the optical modulators and interface to the computer. The intent of this research is to provide a low cost, highly energy efficient coprocessor for linear operations. Measurements of the analog accuracy of the processor performing 128 Mops are presented along with an assessment of the implications for future systems. A range of noise sources, including cross-talk, source amplitude fluctuations, shot noise at the detector, and non-linearities of the optoelectronic components are measured and compared to determine the most significant source of error. The possibilities for reducing these sources of error are discussed. Also, the total error is compared with that expected from a statistical analysis of the individual components and their relation to the vector-matrix operation. The sufficiency of the measured accuracy of the processor is compared with that required for a range of typical problems. Calculations resolving alloy concentrations from spectral plume data of rocket engines are implemented on the optical processor, demonstrating its sufficiency for this problem. We also show how this technology can be easily extended to a 100 x 100 10 MHz (200 Cops) processor.

Gary, Charles K.↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗

Internal thermal coupling in direct-flow coaxial vacuum tube collectors

This investigation covers the impact of low flow rates on the efficiency of coaxial vacuum tube collectors. Measurements show an efficiency reduction of 10% if reducing the flow rate from 78 kg/m{sup 2} h to 31 kg/m{sup 2} h for a collector group with 60 parallel vacuum tubes with a coaxial flow conduit at one-sided connection. For a more profound understanding a model of the coaxial tube was developed which defines the main energy fluxes including the internal thermal coupling. The tube simulations show a non-linear temperature profile along the tube with the maximum temperature in the outer pipe. Due to heat transfer to the entering flow this maximum is not located at the fluid outlet. The non-linearity increases with decreasing flow rates. The experimentally determined flow distribution allows simulating the measured collector array. The simulation results confirm the efficiency decrease at low flow rates. The flow distribution has a further impact on efficiency reduction, but even at an ideal uniform flow, a considerable efficiency reduction at low flow rates is to be expected. As a consequence, low flow rates should be prevented for coaxial tube collectors, thus restricting the possible operation conditions. The effect of constructional modifications like diameter or material variations is presented. Finally the additional impact of a coaxial manifold design is discussed. (author)

14 SOLAR ENERGY↗

Transferring orbital angular momentum to an electron beam reveals toroidal and chiral order

Orbital angular momentum (OAM) and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics. Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices. Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. Instead, we find that the presence of an electric toroidal moment in a ferrorotational phase transfers measurable torque and OAM to a localized electron beam in the ballistic limit. We record these torque transfers from a high-energy electron beam using a momentum-resolved detector. This approach provides a high-sensitivity method to detect polarization fields and their more complex order parameters and topologies. In addition to toroidal order, we also demonstrate high-precision measurements of vorticity and chirality for polar vortexlike phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Endfire tapered slot antennas on dielectric substrates

Endfire-tapered slot antennas are suitable for many integrated circuit applications, imaging and phased arrays. An investigation of single elements of such antennas, including slots which are exponentially tapered (Vivaldi), linearly tapered, and constant width. For antennas of all types, a good general agreement is obtained for curves of beamwidth-versus-length, normalized to wavelength, when one compares the data with that for traveling-wave antennas published by Zucker (1961). An important condition for this agreement is that the effective dielectric thickness, defined in the text, is in a certain optimum range. This condition is qualitatively explained in terms of the theory for traveling-wave antennas.

Yngvesson, K. S.↗

Planar Microstrip Yagi Antennas

Developmental class of antennas based on combination of microstrip-patch and Yagi-array concepts. Mutual coupling between microstrip elements, ordinarily considered nuisance, used to advantage. Applicable to both linearly and circularly polarized antennas. Use of fewer driven elements results in less complexity and reduced loss of power in associated transmission lines and other coupling and power-distributing circuitry. Applications include antennas on land vehicles, television receiving antennas, and conformal antennas on aircraft.

Huang, John↗