Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A blade loss response spectrum for flexible rotor systems

A shock spectrum procedure is developed to estimate the peak displacement response of linear flexible rotor-bearing systems sugjected to a step change in unbalance (i.e., a blade loss). A progressive and a retrograde response spectrum are established. These blade loss response spectra are expressed in a unique non-dimensional form and are functions of the modal damping ratio and the ratio of rotor spin speed to modal damped whirl speed. Modal decomposition using complex modes is utilized to make use of the unique feature of the spectra for the calculation of the peak blade loss displacement response of the rotor system. The procedure is applied to three example systems using several modal superposition strategies. The results of each are compared to true peak displacement obtained by a separate transient response program.

Nelson, H. D.↗

SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

60 APPLIED LIFE SCIENCES↗

SU-E-T-497: Initial Characterization of a Novel 2D Computed Radiography (CR) Dosimeter for SBRT

Purpose For 2D, sub-mm resolution dose measurements Gafchromic™ film is currently a standard in radiotherapy; mainly because of its energy independence and water equivalence. However, EBT film is disposable. Therefore, the dosimetric and uniformity characteristics needs to be estimated from a second, possibly different, (calibration) film. Moreover, EBT has a post-irradiation coloration and a non-linear dose dependence with saturation, which limits the applicable time interval and dose range. CR technology forms an interesting alternative for EBT. Dose dependent CRplates have a sub-mm resolution, and additionally a linear dose dependence over decades of dose. But, CR has an inherent signal fading and energy dependence. Here, for the first time, a radiotherapy 2D CR prototype was characterized for an extended dose range (up to 35Gy), signal fading, and basic energy dependence. Methods The prototype was irradiated with a standard 10×10cm 6MV photon beam, and scanned with a commercial CR 15-X(R) scanner. The time between the start of irradiation and scanning (T-Scan) was monitored. The linearity of the dose response was evaluated between 0 and 35Gy using a fixed T-Scan of 4min, if possible (i.e. ≤10Gy). Next, the signal fading was characterized for a T-Scan-range of 4 to 20min. The energy dependence was assessed by a comparison of out-of-field measurements of CR, EBT, and TLD. Results The radiotherapy CR prototype has a linear response over the complete SBRT dose range (0– 35Gy). The prototype had a small (5%), but linear signal fading over the time interval of interest (4–20min). Out-of-field, the prototype has a 8% over response due to an increased amount of low energy photons. The impact of the over response on intensity modulated radiotherapy remains to be evaluated. Conclusion CR technology is promising for SBRT dose measurements up to 35Gy. It is a reusable linear alternative for film dosimetry.

60 APPLIED LIFE SCIENCES↗

Neutron light output function and resolution investigation of the deuterated organic liquid scintillator EJ-315

Here, we investigate the light response to fast neutrons and estimate the pulse height resolution of a deuterated liquid organic scintillator, EJ-315, considering the detector's non-linear light response to gamma-rays. Initially, collision data and a neutron beam trigger are recorded in coincidence mode, and incident neutron energy is calculated with a time-of-flight technique. Fast neutrons are further discriminated from gamma-ray background based on the scintillation material decay patterns using a pulse shape discrimination algorithm. We also derived a light response matrix composed of multiple neutron energy and their corresponding light outputs. The pulse height resolution property of the EJ-315 is characterized utilizing the derivatives of the pulse height distributions with corrections of the mea-surements setup uncertainties. In addition, the EJ-315's pulse height resolution is also characterized by comparing the smoothed derivatives of quasi-monoenergetic neutron pulse height distributions, given by the Peierls-formula-based analytic model, to match the measurement data. Results show rather consistent 10e13% pulse resolution for mono-energetic neutrons with kinetic energy above 2 MeV. The resolution decreases slightly with an increase in neutron energy indicating the improved resolution performance of EJ-315 in the higher energy events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harderian Gland Tumorigenesis: Low-Dose and LET Response

Increased cancer risk remains a primary concern for travel into deep space and may preclude manned missions to Mars due to large uncertainties that currently exist in estimating cancer risk from the spectrum of radiations found in space with the very limited available human epidemiological radiation-induced cancer data. Existing data on human risk of cancer from X-ray and gamma-ray exposure must be scaled to the many types and fluences of radiations found in space using radiation quality factors and dose-rate modification factors, and assuming linearity of response since the shapes of the dose responses at low doses below 100 mSv are unknown. The goal of this work was to reduce uncertainties in the relative biological effect (RBE) and linear energy transfer (LET) relationship for space-relevant doses of charged-particle radiation-induced carcinogenesis. The historical data from the studies of Fry et al. and Alpen et al. for Harderian gland (HG) tumors in the female CB6F1 strain of mouse represent the most complete set of experimental observations, including dose dependence, available on a specific radiation-induced tumor in an experimental animal using heavy ion beams that are found in the cosmic radiation spectrum. However, these data lack complete information on low-dose responses below 0.1 Gy, and for chronic low-dose-rate exposures, and there are gaps in the LET region between 25 and 190 keV/μm. In this study, we used the historical HG tumorigenesis data as reference, and obtained HG tumor data for 260 MeV/u silicon (LET ~70 keV/μm) and 1,000 MeV/u titanium (LET ~100 keV/μm) to fill existing gaps of data in this LET range to improve our understanding of the dose-response curve at low doses, to test for deviations from linearity and to provide RBE estimates. Animals were also exposed to five daily fractions of 0.026 or 0.052 Gy of 1,000 MeV/u titanium ions to simulate chronic exposure, and HG tumorigenesis from this fractionated study were compared to the results from single 0.13 or 0.26 Gy acute titanium exposures. Theoretical modeling of the data show that a nontargeted effect model provides a better fit than the targeted effect model, providing important information at space-relevant doses of heavy ions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Flutter-Constrained Optimization with the Linearized Frequency-Domain Approach

Due to the high computational cost associated with unsteady aeroelastic analysis, state-of-the-art aeroelastic optimizations based on computational fluid dynamics typically ignore critical constraints like flutter and aeroelastic gust response. The linearized frequency-domain method offers an approach for adding high-fidelity flutter constraints to multidisciplinary optimizations at relatively low cost compared to other unsteady computational fluid dynamics methods. In recent work, sensitivities have been implemented for the linearized frequency-domain method in FUN3D. In this work, the linearized frequency-domain method and associated sensitivities are applied to gradient-based aeroelastic optimization with flutter constraints based on computational fluid dynamics. An overview of the flutter constraint formulation and implementation is provided, and then two optimization problems are presented. The first optimization increases the flutter speed of a pitch and plunge airfoil at transonic conditions using the minimal amount of geometric changes. The second optimization minimizes the mass of the AGARD 445.6 wing subject to a flutter constraint.

Aeroelasticity↗

Flutter-Constrained Optimization with the Linearized Frequency-Domain Approach

Due to the high computational cost associated with unsteady aeroelastic analysis, state-of-the-art aeroelastic optimizations based on computational fluid dynamics typically ignore critical constraints like flutter and aeroelastic gust response. The linearized frequency-domain method offers an approach for adding high-fidelity flutter constraints to multidisciplinary optimizations at relatively low cost compared to other unsteady computational fluid dynamics methods. In recent work, sensitivities have been implemented for the linearized frequency-domain method in FUN3D. In this work, the linearized frequency-domain method and associated sensitivities are applied to gradient-based aeroelastic optimization with flutter constraints based on computational fluid dynamics. An overview of the flutter constraint formulation and implementation is provided, and then two optimization problems are presented. The first optimization increases the flutter speed of a pitch and plunge airfoil at transonic conditions using the minimal amount of geometric changes. The second optimization minimizes the mass of the AGARD 445.6 wing subject to a flutter constraint.

Aeroelasticity↗

Systematic study of doping dependence on linear magnetoresistance in p-PbTe

We report on a large linear magnetoresistance effect observed in doped p-PbTe films. While undoped p-PbTe reveals a sublinear magnetoresistance, p-PbTe films doped with BaF{sub 2} exhibit a transition to a nearly perfect linear magnetoresistance behaviour that is persistent up to 30 T. The linear magnetoresistance slope ΔR/ΔB is to a good approximation, independent of temperature. This is in agreement with the theory of Quantum Linear Magnetoresistance. We also performed magnetoresistance simulations using a classical model of linear magnetoresistance. We found that this model fails to explain the experimental data. A systematic study of the doping dependence reveals that the linear magnetoresistance response has a maximum for small BaF{sub 2} doping levels and diminishes rapidly for increasing doping levels. Exploiting the huge impact of doping on the linear magnetoresistance signal could lead to new classes of devices with giant magnetoresistance behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excitation of Nonlinear Spin Oscillations in an Antiferromagnet under the Action of Pulsed Terahertz Pumping

We present a model of excitation of nonlinear spin oscillations in an antiferromagnet under the action of terahertz pulses of an electromagnetic field. It is shown that, with increasing pumping pulse amplitude, the spin system response increases linearly in the fundamental (resonant) quasi-ferromagnetic mode and quadratically in the second harmonic. We have compared the theoretically obtained dependences of the intensities of the sample response amplitudes for the fundamental mode and the second harmonic with the experimental ones. The comparison demonstrates the applicability of the developed method of analyzing dynamic processes in antiferromagnets occurring under the action of terahertz electromagnetic pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancements in Life Cycle Human Exposure and Toxicity Characterization

The Life Cycle Initiative, hosted at the United Nations Environment Programme, selected human toxicity impacts from exposure to chemical substances as an impact category that requires global guidance to overcome current assessment challenges. The initiative leadership established the Human Toxicity Task Force to develop guidance on assessing human exposure and toxicity impacts. Based on input gathered at three workshops addressing the main current scientific challenges and questions, the task force built a roadmap for advancing human toxicity characterization, primarily for use in life cycle impact assessment (LCIA). The present paper aims at reporting on the outcomes of the task force workshops along with interpretation of how these outcomes will impact the practice and reliability of toxicity characterization. The task force thereby focuses on two major issues that emerged from the workshops, namely considering near-field exposures and improving dose–response modeling. The task force recommended approaches to improve the assessment of human exposure, including capturing missing exposure settings and human receptor pathways by coupling additional fate and exposure processes in consumer and occupational environments (near field) with existing processes in outdoor environments (far field). To quantify overall aggregate exposure, the task force suggested that environments be coupled using a consistent set of quantified chemical mass fractions transferred among environmental compartments. With respect to dose–response, the task force was concerned about the way LCIA currently characterizes human toxicity effects, and discussed several potential solutions. A specific concern is the use of a (linear) dose–response extrapolation to zero. Another concern addresses the challenge of identifying a metric for human toxicity impacts that is aligned with the spatiotemporal resolution of present LCIA methodology, yet is adequate to indicate health impact potential. Further research efforts are required based on our proposed set of recommendations for improving the characterization of human exposure and toxicity impacts in LCIA and other comparative assessment frameworks.

54 ENVIRONMENTAL SCIENCES↗

Accelerating transient simulation of linear reduced order models.

Model order reduction (MOR) techniques have been used to facilitate the analysis of dynamical systems for many years. Although existing model reduction techniques are capable of providing huge speedups in the frequency domain analysis (i.e. AC response) of linear systems, such speedups are often not obtained when performing transient analysis on the systems, particularly when coupled with other circuit components. Reduced system size, which is the ostensible goal of MOR methods, is often insufficient to improve transient simulation speed on realistic circuit problems. It can be shown that making the correct reduced order model (ROM) implementation choices is crucial to the practical application of MOR methods. In this report we investigate methods for accelerating the simulation of circuits containing ROM blocks using the circuit simulator Xyce.

99 GENERAL AND MISCELLANEOUS↗

Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gust response of hingeless rotors

The gust response of a coupled hingeless rotor-fuselage system is studied in both hover and forward flight. Each rotor blade undergoes flap bending, lag bending, and torsional deflections. The blades are discretized into beam elements, each with fifteen nodal degrees of freedom. The fuselage is permitted three translational (vertical, longitudinal, and lateral) and two rotational (pitch and roll) degrees of freedom. The formulation considers a three-dimensional gust field wherein each gust velocity component can have an arbitrary variation in space and time. Aerodynamic loads are obtained using quasisteady strip theory. Wake-induced effects are introduced through dynamic inflow modeling. Dynamic stall and reverse flow effects are also included. Equations governing the rotor-fuselage gust response are linearized about the vehicle propulsive trim state and the blade steady-state defected positions, and solved by time integration. The effects of several parameters on the helicopter gust response are illustrated, including dynamic inflow, lag stiffness, forward speed, gust profile, gust penetration rate, and gust velocity direction.

Bir, G. S.↗

Feedback control design for non-inductively sustained scenarios in NSTX-U using TRANSP

This paper examines a method for real-time control of non-inductively sustained scenarios in NSTX-U by using TRANSP, a time-dependent integrated modeling code for prediction and interpretive analysis of tokamak experimental data, as a simulator. The actuators considered for control in this work are the six neutral beam sources and the plasma boundary shape. To understand the response of the plasma current, stored energy, and central safety factor to these actuators and to enable systematic design of control algorithms, simulations were run in which the actuators were modulated and a linearized dynamic response model was generated. A multi-variable model-based control scheme that accounts for the coupling and slow dynamics of the system while mitigating the effect of actuator limitations was designed and simulated. Simulations show that modest changes in the outer gap and heating power can improve the response time of the system, reject perturbations, and track target values of the controlled values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exact finite element method analysis of viscoelastic tapered structures to transient loads

A general method is presented for determining the dynamic torsional/axial response of linear structures composed of either tapered bars or shafts to transient excitations. The method consists of formulating and solving the dynamic problem in the Laplace transform domain by the finite element method and obtaining the response by a numerical inversion of the transformed solution. The derivation of the torsional and axial stiffness matrices is based on the exact solution of the transformed governing equation of motion, and it consequently leads to the exact solution of the problem. The solution permits treatment of the most practical cases of linear tapered bars and shafts, and employs modeling of structures with only one element per member which reduces the number of degrees of freedom involved. The effects of external viscous or internal viscoelastic damping are also taken into account.

Spyrakos, Constantine Chris↗

Photoconductive detectors with fast temporal response for laser produced plasma experiments

Processes during laser plasma experiments typically have time scales that are less than 100 ps. The measurement of these processes requires x-ray detectors with fast temporal resolution. We have measured the temporal responses and linearity of several different x-ray sensitive photoconductive detectors (PCDs). The active elements of the detectors investigated include both diamond (natural and synthetic) and GaAs crystals. The typical time responses of the GaAs PCDs are approximately 60 ps, respectively. Some characterizations using x-ray radiation from a synchrotron radiation source are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiotherapy Dose Fractionation under Parameter Uncertainty

In radiotherapy, radiation is directed to damage a tumor while avoiding surrounding healthy tissue. Tradeoffs ensue because dose cannot be exactly shaped to the tumor. It is particularly important to ensure that sensitive biological structures near the tumor are not damaged more than a certain amount. Biological tissue is known to have a nonlinear response to incident radiation. The linear quadratic dose response model, which requires the specification of two clinically and experimentally observed response coefficients, is commonly used to model this effect. This model yields an optimization problem giving two different types of optimal dose sequences (fractionation schedules). Which fractionation schedule is preferred depends on the response coefficients. These coefficients are uncertainly known and may differ from patient to patient. Because of this not only the expected outcomes but also the uncertainty around these outcomes are important, and it might not be prudent to select the strategy with the best expected outcome.

60 APPLIED LIFE SCIENCES↗