Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Detecting ionizing radiation using halide perovskite semiconductors processed through solution and alternative methods

We report the direct detection of high-energy radiation such as X-rays and.-rays by semiconductors at room temperature is a challenging proposition that requires remarkably pure and nearly perfect crystals. The emergence of metal halide perovskites, defect-tolerant semiconductors, is reviving hope for new materials in this field after an almost 20 year hiatus. Metal halide perovskites, which combine exceptional optoelectronic properties, versatile chemistry and simple synthesis, are challenging traditional approaches for the development of novel semiconductors for detecting hard radiation. We discuss the relevant physical properties, promising materials, fabrication techniques and device architectures for high-performance, low-cost detectors by targeting next-generation semiconductors for radiation detection. We also present a perspective on the impact of such advances in future medical imaging applications.

36 MATERIALS SCIENCE↗

Enzyme entrapped nanoporous scaffolds formed through flow induced gelation in microfluidic filter device for sensitive biosensing of organophosphorus compounds

A novel and versatile processing method was developed for the formation of gel scaffolds with in-situ AChE-AuNPs immobilization for biosensing of organophosphorus compounds. The biosensor designed by our new approach shows high sensitivity, selectivity and reactivation efficiency. This flow induced immobilziation technique opens up new pathways for designing simple, fast, biocompatible, and cost-effective process for enhanced sensor performance and on-site testing of a variety of toxic organophosphorus compounds.

47 OTHER INSTRUMENTATION↗

Regenerative Feedback Resonant Circuit to Detect Transient Changes in Electromagnetic Properties of Semi-Insulating Materials

A prototype regenerative feedback resonant circuit has been developed for measuring the transient spectral response due to perturbations in properties of various electromagnetic materials. The circuit can accommodate a variety of cavity resonators, shown here in the 8 GHz range, with passive quality factors (Qstat) as high as 7,000 depending upon material loading. The positive feedback enhanced dynamic quality factors (Qdyn) of resonator/material combinations in the regenerative circuit are on the order of 107 - 108. The theory, design, and implementation of the circuit is discussed along with real-time monitored example measurements of effects due to photon-induced charge carriers in high-resistivity silicon wafers and magnetic-field induced perturbations of yttrium-iron garnet.

cavity perturbation↗

Parallel double-plate capacitive proximity sensor modelling based on effective theory

A semi-analytical model for a double-plate capacitive proximity sensor is presented according to the effective theory. Three physical models are established to derive the final equation of the sensor. Measured data are used to determine the coefficients. The final equation is verified by using measured data. The average relative error of the calculated and the measured sensor capacitance is less than 7.5%. The equation can be used to provide guidance to engineering design of the proximity sensors.

36 MATERIALS SCIENCE↗

Enhancement of electrical conductivity in CoO-SiO{sub 2} nanoglasses and large magnetodielectric effect in ZnO-nanoglass composites

Nanoglasses of compositions xCoO·(100-x)SiO{sub 2} (mol. %) with x having values 10, 15, and 20, respectively, were grown within the nanopores of a pellet comprising of ZnO nanoparticles by soaking the latter in a suitable sol followed by necessary heat treatment. Both Co{sup 2+} and Co{sup 3+} ions were present and confirmed by X-ray photoelectron spectroscopy, the fraction of Co{sup 2+} species being ∼ 0.70. Small polaron hopping conduction was found to be present in the nanoglasses. The activation energy in the latter was observed to be smaller (range of 0.32–0.44 eV) than that in the corresponding bulk glass (0.70–0.77 eV). This was caused by the higher free volume in the nanoglass as compared to that of the bulk glass. This was confirmed by the extracted values of intersite separation between cobalt ions, which were higher in the nanoglass. Weak ferromagnetism was exhibited by the nanocomposites. This was ascribed to super exchange interaction between spin moments associated with Co{sup 2+} and Co{sup 3+} ions, respectively, leading to an antiferromagnetic spin alignment. The nanocomposites showed magnetodielectric effect with the magnetodielectric parameter having values in the range of 5.5% to 10%. The experimental data were fitted to equations derived from Catalan's model by invoking a negative and a positive magnetoresistance for nanoglasses of compositions having x = 20 and x = 10, respectively. A weak spin-orbit coupling and wave function shrinkage in a magnetic field for strongly localized states, respectively, are believed to cause such behaviour in the nanoglass systems concerned. Direct magnetoresistance measurements were carried out on the nanocomposites containing nanoglasses having 10CoO and 20CoO, respectively. The trend of results obtained indeed confirmed the presence of positive and negative magnetoresistance in the two nanoglasses, respectively. The materials would be suitable for magnetic sensor applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time observation of dynamic process of oxygen vacancy migration in cerium oxides under electric field

The dynamic process of oxygen vacancy migration driven by the external electric field is directly observed at atomic scale in the cerium oxides (CeO{sub 2}) thin film by in-situ transmission electron microscopy method. When a bias voltage of a proper value is applied across the CeO{sub 2} film, the oxygen vacancies are formed near the interface of CeO{sub 2}/anode, followed by their migration along the direction of the external electric field. The structural modulation occurs in the [110] zone axis due to the ordering of oxygen vacancies. The migration of oxygen vacancies results in the reversible structural transformation, i.e., releasing and storing oxygen processes in CeO{sub 2}, which is of great significance for the ionic and electronic applications of the cerium oxides materials, such as oxygen pump, gas sensor, resistive random access memory, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Trapping of High-Aspect-Ratio NaYF Hexagonal Prisms for kHz-MHz Gravitational Wave Detectors

Here, we present experimental results on optical trapping of Yb-doped β-NaYF subwavelength-thickness high-aspect-ratio hexagonal prisms with a micron-scale radius. The prisms are trapped in vacuum using an optical standing wave, with the normal vector to their face oriented along the beam propagation direction, yielding much higher trapping frequencies than those typically achieved with microspheres of similar mass. This platelike geometry simultaneously enables trapping with low photon-recoil-heating, high mass, and high trap frequency, potentially leading to advances in high frequency gravitational wave searches in the Levitated Sensor Detector, currently under construction. The material used here has previously been shown to exhibit internal cooling via laser refrigeration when optically trapped and illuminated with light of suitable wavelength. Employing such laser refrigeration methods in the context of our work may enable higher trapping intensity and thus higher trap frequencies for gravitational wave searches approaching the several hundred kilohertz range.

47 OTHER INSTRUMENTATION↗

Nanomaterials for Sensing and Electrocatalysis

This special issue provides an overview of recent advances in nanomaterials for sensing and electrocatalysis. The emergence of nanoscience and nanotechnology has led to great advances in electrochemical science and technology, and these advances may lead to a new branch of electrochemistry research-electrochemical nanotechnology-that combines electrochemical techniques with nanotechnologies to address important issues in energy, electronics, environment, and heath care.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Support for chemistry symposia at the 2011 American Association for the Advancement of Science meeting, February 17-21 2011

This proposal supported Chemistry Symposia at the 2011 American Association for the Advancement of Science (AAAS) Meeting in Washington, DC February 17-21, 2011. The Chemistry Section of AAAS presented an unusually strong set of symposia for the 2011 AAAS meeting to help celebrate the 2011 International Year of Chemistry. The AAAS meeting provided an unusual opportunity to convey the excitement and importance of chemistry to a very broad audience and allowed access to a large contingent of the scientific press. Excellent suggestions for symposia were received from AAAS Chemistry Fellows and from the chairs of the American Chemical Society Technical Divisions. The AAAS Chemistry executive committee selected topics that would have wide appeal to scientists, the public, and the press for formal proposals of symposia. The symposia proposals were peer reviewed by AAAS. The Chemistry Section made a strong case to the program selection committee for approval of the chemistry symposia and 6 were approved for the 2011 annual meeting. The titles of the approved symposia were: (1) Powering the Planet: Generation of Clean Fuels from Sunlight and Water, (2) Biological Role and Consequences of Intrinsic Protein Disorder, (3) Chemically Speaking: How Organisms Talk to Each Other, (4) Molecular Self-Assembly and Artificial Molecular Machines, (5) Frontiers in Organic Materials for Information Processing, Energy and Sensors, and (6) Celebrating Marie Curie's 100th Anniversary of Her Nobel Prize in Chemistry. The Chemistry Section of AAAS is provided with funds to support only 1-2 symposia a year. Because of the much greater number of symposia approved in conjunction with observance of the 2011 International Year of Chemistry, additional support was sought from DOE to help support the 30 invited speakers and 8 symposia moderators/organizers. Support for the symposia provided the opportunity to highlight the excitement of current chemical research, to educate the public about the achievements of chemistry and its contributions to the well-being of humankind. The 2011 AAAS Annual Meeting provided an important opportunity to play a prominent role in the global celebration of the 2011 International Year of Chemistry.

08 HYDROGEN↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524

Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.

Pelouch, J. J., Jr.↗

Astrophysics space systems critical technology needs

This paper addresses an independent assessment of space system technology needs for future astrophysics flight programs contained within the NASA Space Systems Technology Model. The critical examination of the system needs for the approximately 30 flight programs in the model are compared to independent technology forecasts and possible technology deficits are discussed. These deficits impact the developments needed for spacecraft propulsion, power, materials, structures, navigation, guidance and control, sensors, communications and data processing. There are also associated impacts upon in-orbit assembly technology and space transportation systems. A number of under-utilized technologies are highlighted which could be exploited to reduce cost and enhance scientific return.

Gartrell, C. F.↗

Research and technology, 1984 report

Research and technology projects in the following areas are described: cryogenic engineering, hypergolic engineering, hazardous warning instrumentation, structures and mechanics, sensors and controls, computer sciences, communications, material analysis, biomedicine, meteorology, engineering management, logistics, training and maintenance aids, and technology applications.

Source record↗

Spectral contents readout of birefringent sensors

The objective of the research performed was to establish the feasibility of using spectral contents analysis to measure accurately, strains and retardation in birefringent sensors, and more generally, on transparent materials.

Redner, Alex S.↗