Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Arctic Methane, Carbon Aerosols, and Tracers Study Field Campaign Report

The Arctic Methane, Carbon Aerosols, and Tracers Study was a measurement campaign at the National Oceanic and Atmospheric Administration (NOAA) Barrow Observatory and U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) sites in Barrow (formerly known as Utqiagvik) that involved the deployment of instruments to measure CH4, black carbon (BC), and source tracers. The campaign ran from September 1, 2014 to September 1, 2016 and was extended until July 30, 2017. We deployed an in situ instrument to measure methane, the ratio of its isotopologues 13CH4/12CH4, and ethane. We deployed a second instrument to measure carbon monoxide, carbonyl sulfide (COS), carbon dioxide, and water vapor. We also deployed an in situ instrument to measure BC, a single-particle soot photometer (SP2), at the nearby NOAA Barrow Observatory, co-located with the other NOAA aerosol instruments. Changes in emissions across different regions and seasons will be inferred using atmospheric transport and inverse modeling techniques.

North Slope of Alaska, trace gases, black carbon, ↗

Statistical Process Control and Capability Study on the Water Content Measurements in NASA Glenn's Icing Research Tunnel

The Icing Research Tunnel (IRT) at NASA Glenn Research Center follows the recommended practice for icing tunnel calibration outlined in SAE's ARP5905 document. The calibration team has followed the schedule of a full calibration every five years with a check calibration done every six months following. The liquid water content of the IRT has maintained stability within in the specifications presented to customers that the variation is within +/- 10% of the calibrated, target measurement. With recent measurements and instrumentation errors, a more thorough assessment of error source was desired. By constructing statistical process control charts, the ability to determine how the instrument varies in the short term, mid term, and long term was gained. The control charts offer a view of instrument error, facility error, or installation changes. It was discovered that there was a shift from target to mean baseline thus leading to the study of the overall capability indices of the liquid water content measuring instrument to perform within specifications defined in the IRT. This presentation describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, canonical correlation analysis, Chauvenet's Criterion for rejection of data, distribution check of data, and mean, median and mode for construction of control charts. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor and the ability to maintain a stable process for the defined calibration schedule.

Timko, Emily N.↗

Aethalometer™ Instrument Handbook

The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

54 ENVIRONMENTAL SCIENCES↗

The Probing In-Situ With Neutron and Gamma Rays (PING) Instrument for Planetary Composition Measurements

The Probing In situ with Neutrons and Gamma rays (PING) instrument (formerly named PNG-GRAND) [I] experiment is an innovative application of the active neutron-gamma ray technology successfully used in oil field well logging and mineral exploration on Earth over many decades. The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring PING to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asteroids, comets and the satellites of the outer planets and measure their bulk surface and subsurface elemental composition without the need to drill into the surface. Gamma-Ray Spectrometers (GRS) have been incorporated into numerous orbital planetary science missions. While orbital measurements can map a planet, they have low spatial and elemental sensitivity due to the low surface gamma ray emission rates reSUlting from using cosmic rays as an excitation source, PING overcomes this limitation in situ by incorporating a powerful neutron excitation source that permits significantly higher elemental sensitivity elemental composition measurements. PING combines a 14 MeV deuterium-tritium Pulsed Neutron Generator (PNG) with a gamma ray spectrometer and two neutron detectors to produce a landed instrument that can determine the elemental composition of a planet down to 30 - 50 cm below the planet's surface, The penetrating nature of .5 - 10 MeV gamma rays and 14 MeV neutrons allows such sub-surface composition measurements to be made without the need to drill into or otherwise disturb the planetary surface, thus greatly simplifying the lander design, We are cun'ently testing a PING prototype at a unique outdoor neutron instrumentation test facility at NASA/GSFC that provides two large (1.8 m x 1.8 m x ,9 m) granite and basalt test formations placed outdoors in an empty field, Since an independent trace elemental analysis has been performed on both these Columbia River basalt and Concord Gray granite materials, these large samples present two known standards with which to compare PING's experimentally measured elemental composition results, We will present both gamma ray and neutron experimental results from PING measurements of the granite and basalt test formations in various layering configurations and compare the results to the known composition.

Parsons, A.↗

Future instrumentation and missions for measurements of tropospheric trace species from space: Workshop recommendations

It was recommended that gas filter correlation radiometry and high-resolution interferometry be exploited and expanded for measurements of the distribution of tropospheric trace gases. Instruments and missions were identified and discussed. Several instrument/measurement/mission feasibility studies were recommended, including: a three-layer measurement of carbon monoxide, using a nadir-viewing gas filter correlation radiometer; a lower or middle tropospheric measurement of methane, using a nadir-viewing gas filter correlation radiometer; and a survey of lower, middle, and upper tropospheric trace gases using a nadir-viewing high-resolution interferometer operating in the thermal emission mode. It was also concluded that lidar systems appear to have the potential of obtaining measurments of tropospheric trace gases and aerosols from space. In addition to the specific instrument/mission recommendations, the panels made several general recommendations that may lead to future spaceborne instruments, techniques, and missions for tropospheric research.

Source record↗

Instrumentation and data acquisition systems

A comprehensive and integrated measurement system was identified and a design and development effort initiated to meet the criteria imposed by the National Transonic Facility operating environment. Specific measurement areas receiving concentrated attention include: data acquisition, force measurement, pressure instrumentation, flow visualization techniques, model attitude and model deformation measurement, and temperature measurement. The NTF instrument complex will be centered around four 32-bit, 1-microsecond-cycle-time central processing units connected in a multipoint-distributed network configuration. The principal activities to be supported by these computers are: (1) data base management and processing; (2) research measurement data acquisition and display; (3) tunnel and model control; and (4) process monitoring and communication control. The distributed network approach was chosen to modularize the functional software into definable and implementable parts by the various groups involved in the design and to permit use of similar hardware configurations to improve reliability and maintainability.

Guarino, J. F.↗

Experimental active and passive dosimetry systems for the NASA Skylab program

Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

Schneider, M. F.↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

Feasibility of using in situ deformation to monitor CO 2 storage

Deformation during CO 2 injection can lead to problems, like seismicity or fluid leaks, but small strains have the potential to be a useful signal for monitoring. The objective of this paper is to evaluate the possible evolution of the strain field during injection, and then assess existing and emerging techniques for measuring the strain field. Poroelastic analyses show that normal strains caused by injection into a reservoir are tensile in the vicinity of the well, but everywhere else at least one strain component is compressive. The vertical strain is compressive in the confining unit, and the radial strain decreases and changes sign from tensile to compressive with distance from the well. Tilting is away from the injection well at the ground surface, but it is towards the well overlying the reservoir. Methods for measuring in-situ strain include instruments that are grouted in the annulus between casing and wall rock (~ 0.1 microstrain resolution), portable strain sensors that are temporarily clamped to the borehole wall (~0.01 microstrain resolution), and strainmeters that are grouted in place (~0.001 microstrain resolution). Instruments for measuring in-situ normal strains at the magnitudes and rates expected during injection are emerging, but they have yet to be fully evaluated in applications related to CO 2 storage. Finally, in-situ strain data measured with emerging instruments promises to fill an important gap between the episodes of fast strain rates measured by seismic data, and the slow strains measured over relatively long periods of time by InSAR and GPS.

42 ENGINEERING↗

Cloud Physics Lidar: Instrument Description and Initial Measurement Results

The Cloud Physics Lidar (CPL) is a new custom-built instrument for the NASA ER-2 high-altitude aircraft. The CPL can provide multiwavelength measurements of cirrus, subvisual cirrus, and aerosols with high temporal and spatial resolution. Its state-of-the-art technology gives it a high repetition rate, and photon-counting detection, and includes a low-pulse-energy laser. The CPL was first deployed at the Southern African Regional Science Initiative's 2000 field campaign during August and September 2000. This paper provides an overview of the instrument and initial data results to illustrate the measurement capability of the CPL.

McGill, Matthew↗

Towards a Preservation Content Standard for Earth Observation Data

Information from Earth observing missions (remote sensing with airborne and spaceborne instruments, and in situ measurements such as those from field campaigns) is proliferating in the world. Many agencies across the globe are generating important datasets by collecting measurements from instruments on board aircraft and spacecraft, globally and constantly. The data resulting from such measurements are a valuable resource that needs to be preserved for the benefit of future generations. These observations are the primary record of the Earths environment and therefore are the key to understanding how conditions in the future will compare to conditions today. Earth science observational data, derived products and models are used to answer key questions of global significance. In the near-term, as long as the missions data are being used actively for scientific research, it continues to be important to provide easy access to the data and services commensurate with current information technology. For the longer term, when the focus of the research community shifts toward new missions and observations, it is essential to preserve the previous mission data and associated information. This will enable a new user in the future to understand how the data were used for deriving information, knowledge and policy recommendations and to repeat the experiment to ascertain the validity and possible limitations of conclusions reached in the past and to provide confidence in long term trends that depended on data from multiple missions. Organizations that collect, process, and utilize Earth observation data today have a responsibility to ensure that the data and associated content continue to be preserved by them or are gathered and handed off to other organizations for preservation for the benefit of future generations. In order to ensure preservation of complete content necessary for understanding and reusing the data and derived digital products from todays missions, it is necessary to develop a specification of such preservation content. While there are existing standards that address archival and preservation in general, there are no existing international standards or specifications today to address what content should be preserved. The purpose of this paper is to outline briefly the existing standards that apply to preservation, describe a recent effort in getting an international standard in place for specifying preservation content for Earth observation data and derived digital data products and the remaining work needed to arrive at a standard.

ISO Standards↗

Nitric acid oxide mixing ratio measurements using a rocket launched chemiluminescent instrument

A total of 18 rocket launched parachute borne nitric oxide instruments were launched from 1977 to 1985. A very precise instrument for the measurement of the nitric oxide mixing ratio was fabricated. No changes were made in the main body of the instruments, i.e., things associated with the reaction volume. Except for the last 4 launches, however, it did not yield the required absolute values that was hoped for. Two major problems were encountered. First, the wrong choice of the background calibration gas, nitrogen, caused the first 10 data sets to be too low in the absolute mixing ratio by nearly the order of 2 to 5 ppbv. The error was realized, and air was substituted for the bias gas measurement. Second, in the desire to extend the measurement to higher altitudes, the problem of contaminating the inlet flow tube with ozone from the reagent gas was encountered. The ozone valve was opened too early in the flight and this caused the pressure in the reaction volume to exceed the pressure at the flow tube entrance, permitting the ozone to migrate backwards. This problem was restricted to an altitude above 45 km.

Horvath, Jack J.↗

Considerations for acoustic emission monitoring of spherical Kevlar/epoxy composite pressure vessels

We are continuing to research the applications of acoustic emission testing for predicting burst pressure of filament-wound Kevlar 49/epoxy pressure vessels. This study has focused on three specific areas. The first area involves development of an experimental technique and the proper instrumentation to measure the energy given off by the acoustic emission transducer per acoustic emission burst. The second area concerns the design of a test fixture in which to mount the composite vessel so that the acoustic emission transducers are held against the outer surface of the composite. Included in this study area is the calibration of the entire test setup including couplant, transducer, electronics, and the instrument measuring the energy per burst. In the third and final area of this study, we consider the number, location, and sensitivity of the acoustic emission transducers used for proof testing composite pressure vessels.

Hamstad, M. A.↗

Use of TEMPO as a Proxy for Hyperspectral Geostationary Ocean Color Measurements from the GeoXO OCX Instrument: Harnessing Machine Learning and Principal Component Techniques for Atmospheric and Glint Correction

Retrievals of ocean color from space are important for better understanding the ocean ecosystem. The launch of atmospheric geostationary hyperspectral sensors such as TEMPO, provides a unique opportunity to examine the diurnal variability in ocean ecology. While TEMPO does not have as high spatial resolution or full spectral coverage as planned coastal ocean sensors such as the Geosynchronous Littoral Imaging and Monitoring Radiometer (GLIMR) or GeoXO Ocean Color instrument (OCX), its hourly measurements provide coverage of regions such as Lake Erie and the Gulf of Mexico at spatial scales of approximately 5 km. These data can be useful for testing new algorithms. We will apply our newly developed machine learning based atmospheric correction approach for ocean color retrievals to TEMPO data. Our approach begins by decomposing measured radiances from hyperspectral sensors into spectral features that describe the scattering and absorption of the atmosphere as well as the underlying surface reflectance. The coefficients of the principal components are then used to train a neural network to predict ocean color properties derived from collocated MODIS/VIIRS physically-based retrievals. This machine learning approach does not rely on radiative transfer modeling, and the use of MODIS/VIIRS data for training accounts for possible calibration b in hyperspectral data. Previously, we applied our approach using blue and UV wavelengths with the Ozone Monitoring Instrument (OMI) and TROPOspheric Monitoring Instrument (TROPOMI) to show that it can estimate ocean color properties in less-than-ideal conditions such as lightly to moderately clouded conditions as well as sun glint and thus improve the spatial coverage of ocean color measurements. TEMPO provides an opportunity to improve on this approach since it will provide collocated measurements at green and red wavelengths that were not available from OMI and TROPOMI and are important particularly for coastal waters. Additionally, our technique can be applied early in the mission and has potential to demonstrate the value of near real time ocean color products that are important for monitoring of harmful algae blooms and other oceanic phenomena.

Zachary Fasnacht↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗

Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

Vargas, Magda B.↗

Surface finish measurement studies

The performance of stylus instruments for measuring the topography of National Transonic Facility (NTF) model surfaces both for monitoring during fabrication and as an absolute measurement of topography was evaluated. It was found that the shop-grade instruments can damage the surface of models and that their use for monitoring fabrication procedures can lead to surface finishes that are substantially out of range in critical areas of the leading edges. The development of a prototype light-scattering instrument which would allow for rapid assessment of the surface finish of a model is also discussed.

Teague, E. C.↗