Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Optimization of carbon capture systems using surrogate models of simulated processes.

With increasing demand placed on power generation plants to reduce carbon dioxide (CO2) emissions, processes to separate and capture CO2 for eventual sequestration are highly sought after. Carbon capture processes impart a parasitic load on the power plants; it is estimated that this would increase the cost of electricity from existing pulverized coal plants anywhere from 71-85 percent [1]. The National Energy and Technology Lab (NETL) is working to lower this to below a 30 percent increase. To reach this goal, work is being done not only to accurately simulate these processes, but also to leverage those accurate and detailed simulations to design optimal carbon capture processes. The major challenges include the lack of accurate algebraic models of the processes, computationally costly simulations, and insufficiently robust simulations. The first challenge bars the use of provable derivative-based optimization algorithms. The latter two can either lead to difficult or impossible direct derivative-free optimization. To overcome these difficulties, we take a more indirect method to solving this problem by, first, generating an accurate set of algebraic surrogate models from the simulation then using derivative-based solvers to optimize the surrogate models. We developed a method that uses derivative-based and derivative-free optimization alongside machine learning and statistical techniques to generate the set of low-complexity surrogate models using data sampled from detailed simulations. The models are validated and improved through the use of derivative-free solvers to adaptively sample new simulation points. The resulting surrogate models can then be used in a superstructure-based process synthesis and solved using derivative-based methods to optimize carbon capture processes.

01 COAL, LIGNITE, AND PEAT↗

Selection of an optimal plan for construction of a spacecraft antenna system

An attempt is made to summarize the experience of the design of antennas for various types of spacecraft: fully oriented, partially oriented, and with arbitrary orientation. Several examples of the construction of antenna systems and their characteristics are given. The optimal relationship between weight, dimension and power characteristics of on-board devices allows selection of the most acceptable versions. Questions are presented for consideration in design of optimal spacecraft antenna-feeder systems.

Prigoda, B. A.↗

Manual of phosphoric acid fuel cell power plant optimization model and computer program

An optimized cost and performance model for a phosphoric acid fuel cell power plant system was derived and developed into a modular FORTRAN computer code. Cost, energy, mass, and electrochemical analyses were combined to develop a mathematical model for optimizing the steam to methane ratio in the reformer, hydrogen utilization in the PAFC plates per stack. The nonlinear programming code, COMPUTE, was used to solve this model, in which the method of mixed penalty function combined with Hooke and Jeeves pattern search was chosen to evaluate this specific optimization problem.

Lu, C. Y.↗

Capturing Infrastructure Interdependencies for Power Outages Prediction During Extreme Events

As extreme weather events such as hurricanes, severe thunderstorms, and floods grow in frequency and intensity, the disruption of power grid systems poses significant challenges, including widespread electrical outages, economic losses, and threats to public safety. This paper presents a forward-looking approach that leverages geographical graph-based machine learning models to predict county-level maximum power outages during such events. By capturing the intricate interdependencies within power system networks, our approach aims to provide precise and actionable predictions that can optimize emergency response efforts and enhance grid resilience. Through the integration of real-world data, including hurricane advisories and power outage records, we have trained and benchmarked multiple machine learning models, demonstrating the feasibility and potential of this method. While our initial results are promising, this paper also charts a course for advancing these models, addressing the remaining challenges, and ultimately transforming how we anticipate and respond to the impacts of extreme weather on power systems.

Lee, Sangkeun (Matt) [ORNL] (ORCID:000000021317511↗

A transfer learning approach to energy-efficient control of small and medium-sized commercial buildings

Model-free reinforcement learning (RL) provides a data-driven and adaptive approach to optimize building energy use while satisfying occupant comfort. This powerful tool does not need any prior knowledge about the environment and system it is optimizing and can adapt its policy based on the changes in captures. Like any other data-driven tool, it faces high training costs due to the extensive agent-environment interactions required to capture long-term building dynamics and user comfort. Transfer learning, particularly policy distillation, offers a promising way to accelerate training by leveraging pretrained RL agents in different building and system types. Here, this study investigates online student distillation, in which the student model updates its neural network weights using outputs from teacher models. The work introduces a student distillation strategy designed for efficient knowledge transfer, along with a teacher selection method that ensures high-quality guidance. The approach is validated using a highly calibrated whole building energy model for a small/medium commercial building test facility. Results show substantial reductions in training time and data requirements while surpassing the performance of ASHRAE Guideline 36, an advanced rule-based control strategy. The distilled RL model required 45% less data and achieved 20% higher cumulative rewards than a state-of-the-art RL model, with faster convergence and lower energy consumption. These outcomes demonstrate that effective transfer learning enables a scalable and data-efficient energy management solution for commercial buildings.

ASHRAE guideline 36↗

H ∞ Control for Energy Dispatch in Autonomous Nanogrid With Communication Delays

This paper proposes an optimal controller and estimator for energy dispatch to balance the power supply and demand considering communication delays. The proposed algorithm involves modeling an autonomous nanogrid (ANG) consisting of distributed energy resources, energy storage systems, loads, an $H$ ∞ controller with a reference power modulation technique, and a state estimator. The ANG was developed to express the dynamic supply-demand energy balance of a nanogird system. Reference power modulation was designed to generate the desired ESS power based on the imbalanced energy. Random communication delays were modeled using a stochastic variable satisfying the Bernoulli random binary distribution. The optimal $H$ ∞ controller and estimator were developed using a linear matrix inequality approach to exponentially stabilize the closed-loop system. Simulations were performed using real daily demand forecasts obtained from the Korea Meteorological Administration to demonstrate the effectiveness of the proposed real-time optimization algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hierarchical Modeling for Reactive Power Optimization With Joint Transmission and Distribution Networks by Curve Fitting

Here, in order to solve the reactive power optimization with joint transmission and distribution networks, a hierarchical modeling method is proposed in this paper. It allows the reactive power optimization of transmission and distribution networks to be performed separately, leading to a master–slave structure and improves traditional centralized modeling methods by alleviating the big data problem in a control center. Specifically, the transmission-distribution-network coordination issue of the hierarchical modeling method is investigated. First, a curve-fitting approach is developed to provide a cost function of the slave model for the master model, which reflects the impacts of each slave model. Second, the transmission and distribution networks are decoupled at feeder buses, and all the distribution networks are coordinated by the master reactive power optimization model to achieve the global optimality. Finally, numerical results on two test systems verify the effectiveness of the proposed hierarchical modeling and curve-fitting methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of the FRIB beam dump: a hybrid genetic algorithm and reinforcement learning approach

The operational envelope of high-power-density systems, such as particle accelerators and advanced nuclear energy systems, is critically constrained by the need to manage extreme thermal loads. To address this, we present a novel hybrid optimization framework combining a genetic algorithm (GA) with a soft actor-critic (SAC) deep reinforcement learning agent. This framework was applied to a practical high-heat-flux problem: redesigning the beam dump at the Facility for Rare Isotope Beams (FRIB) for a power upgrade from 20 kW to 50 kW. The resulting design, validated by three-dimensional conjugate heat transfer simulations, suppresses hazardous hot spots and yields a markedly more uniform temperature distribution. This provides a robust operating margin, increasing the average power-handling capability by 72% relative to the current design, demonstrating the framework’s potential to solve complex thermal management challenges in both accelerator technology and advanced nuclear systems.

Accelerator↗

Wind power forecasting : state-of-the-art 2009.

Many countries and regions are introducing policies aimed at reducing the environmental footprint from the energy sector and increasing the use of renewable energy. In the United States, a number of initiatives have been taken at the state level, from renewable portfolio standards (RPSs) and renewable energy certificates (RECs), to regional greenhouse gas emission control schemes. Within the U.S. Federal government, new energy and environmental policies and goals are also being crafted, and these are likely to increase the use of renewable energy substantially. The European Union is pursuing implementation of its ambitious 20/20/20 targets, which aim (by 2020) to reduce greenhouse gas emissions by 20% (as compared to 1990), increase the amount of renewable energy to 20% of the energy supply, and reduce the overall energy consumption by 20% through energy efficiency. With the current focus on energy and the environment, efficient integration of renewable energy into the electric power system is becoming increasingly important. In a recent report, the U.S. Department of Energy (DOE) describes a model-based scenario, in which wind energy provides 20% of the U.S. electricity demand in 2030. The report discusses a set of technical and economic challenges that have to be overcome for this scenario to unfold. In Europe, several countries already have a high penetration of wind power (i.e., in the range of 7 to 20% of electricity consumption in countries such as Germany, Spain, Portugal, and Denmark). The rapid growth in installed wind power capacity is expected to continue in the United States as well as in Europe. A large-scale introduction of wind power causes a number of challenges for electricity market and power system operators who will have to deal with the variability and uncertainty in wind power generation when making their scheduling and dispatch decisions. Wind power forecasting (WPF) is frequently identified as an important tool to address the variability and uncertainty in wind power and to more efficiently operate power systems with large wind power penetrations. Moreover, in a market environment, the wind power contribution to the generation portofolio becomes important in determining the daily and hourly prices, as variations in the estimated wind power will influence the clearing prices for both energy and operating reserves. With the increasing penetration of wind power, WPF is quickly becoming an important topic for the electric power industry. System operators (SOs), generating companies (GENCOs), and regulators all support efforts to develop better, more reliable and accurate forecasting models. Wind farm owners and operators also benefit from better wind power prediction to support competitive participation in electricity markets against more stable and dispatchable energy sources. In general, WPF can be used for a number of purposes, such as: generation and transmission maintenance planning, determination of operating reserve requirements, unit commitment, economic dispatch, energy storage optimization (e.g., pumped hydro storage), and energy trading. The objective of this report is to review and analyze state-of-the-art WPF models and their application to power systems operations. We first give a detailed description of the methodologies underlying state-of-the-art WPF models. We then look at how WPF can be integrated into power system operations, with specific focus on the unit commitment problem.

17 WIND ENERGY↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reliable Thermoelectric Module Design under Opposing Requirements from Structural and Thermoelectric Considerations

Structural reliability of thermoelectric generation (TEG) systems still remains an issue especially for applications such as large scale industrial or automobile exhaust heat recovery where a TEG system is subject to dynamic loads and thermal cycling. Traditional thermoelectric (TE) system design and optimization techniques, focused on performance alone, could result in designs that may fail during operation as the geometric requirements for optimal performance (especially the power) are often in conflict with the requirements for mechanical reliability. This study focused on reducing the thermomechanical stresses in a TEG system without compromising the optimized system performance. Finite element simulations were carried out to study the effect of TE element (leg) geometry such as the leg length and cross-sectional shape under constrained material volume requirements. Results indicated that the element length has a major influence on the element stresses whereas the regular cross-sectional shapes have minor influence. Additionally, the impact of TE element stresses on the mechanical reliability is evaluated with the brittle material failure theory based on Weibull analysis. An alternate couple configuration that relies on the industry practice of redundant element design is investigated. Results showed that the alternate configuration considerably reduced the TE element and metallization stresses thereby enhancing the structural reliability with little trade-off in the optimized performance. The proposed alternate configuration could serve as a potential design modification for improving the reliability of systems optimized for thermoelectric performance.

36 MATERIALS SCIENCE↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-dimensional neutronics optimization of helium-cooled blanket for multi-functional experimental fusion-fission hybrid reactor (FDS-MFX)

Three-dimensional neutronics optimization calculations were performed to analyse the parameters of Tritium Breeding Ratio (TBR) and maximum average Power Density (PDmax) in a helium-cooled multi-functional experimental fusion-fission hybrid reactor named FDS (Fusion-Driven hybrid System)-MFX (Multi-Functional experimental) blanket. Three-stage tests will be carried out successively, in which the tritium breeding blanket, uranium-fueled blanket and spent-fuel-fueled blanket will be utilized respectively. In this contribution, the most significant and main goal of the FDS-MFX blanket is to achieve the PDmax of about 100 MW/m3 with self-sustaining tritium (TBR {>=} 1.05) based on the second-stage test with uranium-fueled blanket to check and validate the demonstrator reactor blanket relevant technologies based on the viable fusion and fission technologies. Four different enriched uranium materials were taken into account to evaluate PDmax in subcritical blanket: (i) natural uranium, (ii) 3.2% enriched uranium, (iii) 19.75% enriched uranium, and (iv) 64.4% enriched uranium carbide. These calculations and analyses were performed using a home-developed code VisualBUS and Hybrid Evaluated Nuclear Data Library (HENDL). The results showed that the performance of the blanket loaded with 64.4% enriched uranium was the most attractive and it could be promising to effectively obtain tritium self-sufficiency (TBR-1.05) and a high maximum average power density ({approx}100 MW/m{sup 3}) when the blanket was loaded with the mass of {sup 235}U about 1 ton. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Parameter Design and Optimal Control of an Open Core Flywheel Energy Storage System

In low earth orbit (LEO) satellite applications spacecraft power is provided by photovoltaic cells and batteries. To overcome battery shortcomings the University of Maryland, working in cooperation with NASA/GSFC and NASA/LeRC, has developed a magnetically suspended flywheel for energy storage applications. The system is referred to as an Open Core Composite Flywheel (OCCF) energy storage system. Successful application of flywheel energy storage requires integration of several technologies, viz. bearings, rotor design, motor/generator, power conditioning, and system control. In this paper we present a parameter design method which has been developed for analyzing the linear SISO model of the magnetic bearing controller for the OCCF. The objective of this continued research is to principally analyze the magnetic bearing system for nonlinear effects in order to increase the region of stability, as determined by high speed and large air gap control. This is achieved by four tasks: (1) physical modeling, design, prototyping, and testing of an improved magnetically suspended flywheel energy storage system, (2) identification of problems that limit performance and their corresponding solutions, (3) development of a design methodology for magnetic bearings, and (4) design of an optimal controller for future high speed applications. Both nonlinear SISO and MIMO models of the magnetic system were built to study limit cycle oscillations and power amplifier saturation phenomenon observed in experiments. The nonlinear models include the inductance of EM coils, the power amplifier saturation, and the physical limitation of the flywheel movement as discussed earlier. The control program EASY5 is used to study the nonlinear SISO and MIMO models. Our results have shown that the characteristics and frequency responses of the magnetic bearing system obtained from modeling are comparable to those obtained experimentally. Although magnetic saturation is shown in the bearings, there are good correlations between the theoretical model and experimental data. Both simulation and experiment confirm large variations of the magnetic bearing characteristics due to air gap growth. Therefore, the gap growth effect should be considered in the magnetic bearing system design. Additionally, the magnetic bearing control system will be compared to other design methods using not only parameter design but H-infinity optimal control and mu synthesis.

Pang, D.↗

Real-Time Optimization of Distribution-level Energy Resources [SWR-18-27]

Researchers at NREL have developed a novel real-time control architecture to optimize the operation of DERs at residential, commercial, and industrial levels. The real-time system enables (portions of) feeders to emulate virtual power plants providing services to the rest of the grid, while ensuring satisfaction of electrical limits and maximizing customers’ benefits. This system can be integrated with legacy hardware and/or new advanced systems to optimally manage both individually-controlled DERs and aggregations of DERs. By virtue of the proposed engineering approach, the DERs collectively regulate the powers at an electrical point to respond to grid dispatch signals such as an automatic generation control, a ramping signal, or a 5-minute dispatch. Overall, this architecture allows end customers to minimize their payments and partake in grid operations while guaranteeing power quality in the distribution network.

Dall-Anese, Emiliano↗