Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Cosmic Reionization on Computers: Baryonic Effects on Halo Concentrations during the Epoch of Reionization

Baryons both increase halo concentration through adiabatic contraction and expel mass through feedback processes. However, it is not well understood how the radiation fields prevalent during the epoch of reionization affect the evolution of concentration in dark matter halos. We investigate how baryonic physics during the epoch of reionization modify the structure of dark matter halos in the Cosmic Reionization On Computers (CROC) simulations. We use two different measures of halo concentration to quantify the effects. We compare concentrations of halos matched between full-physics simulations and dark-matter-only simulations with identical initial conditions between 5 ≤ z ≤ 9. Baryons in full-physics simulations do pull matter toward the center, increasing the maximum circular velocity compared to dark-matter-only simulations. However, their overall effects are much less than if all the baryons were simply centrally concentrated indicating that heating processes efficiently counteract cooling effects. Finally, we show that the baryonic effects on halo concentrations at z ≈ 5 are relatively insensitive to environmental variations of reionization history. These results are pertinent to models of galaxy–halo connection during the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dynamically Distinct Stellar Population in the Leading Arm of the Sagittarius Stream

We present a chemical and dynamical analysis of the leading arm (LA) and trailing arm (TA) of the Sagittarius (Sgr) stream, as well as for the Sgr dwarf galaxy core (SC), using red giant branch, main-sequence, and RR Lyrae stars from large spectroscopic survey data. The different chemical properties among the LA, TA, and SC generally agree with recent studies and can be understood by a radial metallicity gradient established in the progenitor of the Sgr dwarf, followed by preferential stellar stripping from the outer part of the Sgr progenitor. One striking finding is a relatively larger fraction of low-eccentricity stars (e < 0.4) in the LA than in the TA and SC. The TA and SC exhibit very similar distributions. Considering that a tidal tail stripped off from a dwarf galaxy maintains the orbital properties of its progenitor, we expect that the e-distribution of the LA should be similar to that of the TA and SC. Thus, the disparate behavior of the e-distribution of the LA is of particular interest. Following the analysis of Vasiliev et al., we attempt to explain the different e-distribution by introducing a time-dependent perturbation of the Milky Way by the Large Magellanic Cloud's (LMC) gravitational pull, resulting in substantial evolution of the angular momentum of the LA stars to produce the low-e stars. In addition, we confirm from RR Lyrae stars with high eccentricity (e > 0.6) that the TA stars farther away from the SC are also affected by disturbances from the LMC.

79 ASTRONOMY AND ASTROPHYSICS↗

Friction Stir Spot Welding (FSSW) of Advanced High Strength Steel (AHSS)

Friction stir spot welding (FSSW) is applied to join advanced high strength steels (AHSS): galvannealed dual phase 780 MPa steel (DP780GA), transformation induced plasticity 780 MPa steel (TRIP780), and hot-stamped boron steel (HSBS). A low-cost Si3N4 ceramic tool was developed and used for making welds in this study instead of polycrystalline cubic boron nitride (PCBN) material used in earlier studies. FSSW has the advantages of solid-state, low-temperature process, and the ability of joining dissimilar grade of steels and thicknesses. Two different tool shoulder geometries, concave with smooth surface and convex with spiral pattern, were used in the study. Welds were made by a 2-step displacement control process with weld time of 4, 6, and 10 seconds. Static tensile lap-shear strength achieved 16.4 kN for DP780GA-HSBS and 13.2kN for TRIP780-HSBS, above the spot weld strength requirements by AWS. Nugget pull-out was the failure mode of the joint. The joining mechanism was illustrated from the cross-section micrographs. Microhardness measurement showed hardening in the upper sheet steel (DP780GA or TRIP780) in the weld, but softening of HSBS in the heat-affect zone (HAZ). The study demonstrated the feasibility of making high-strength AHSS spot welds with low-cost tools.

36 MATERIALS SCIENCE↗

Evaluating the Impact of Road Grade on Simulated Commercial Vehicle Fuel Economy Using Real-World Drive Cycles

Commercial vehicle fuel economy is known to vary significantly with both positive and negative road grade. Medium- and heavy-duty vehicles operating at highway speeds require incrementally larger amounts of energy to pull heavy payloads up inclines as road grade increases. Non-hybrid vehicles are then unable to recapture energy on descent and lose energy through friction braking. While the on-road effects of road grade are well understood, the majority of standard commercial vehicle drive cycles feature no climb or descent requirements. Additionally, existing literature offers a limited number of sources that attempt to estimate the on-road energy implications of road grade in the medium- and heavy-duty space. This study uses real-world commercial vehicle drive cycles from the National Renewable Energy Laboratory's Fleet DNA database to simulate the effects of road grade on fuel economy across a range of vocations, operating conditions, and locations. Drive-cycles are matched with vocation-specific vehicle models and simulated with and without grade. Fuel use due to grade is presented, and variation in fuel consumption due to drive cycle and vehicle characteristics is explored through graphical and statistical comparison. The results of this study suggest that road grade accounts for 1%-9% of fuel use in commercial vehicles on average and up to 40% on select routes.

33 ADVANCED PROPULSION SYSTEMS↗

Light-duty Plug-in Electric Vehicles in China: Evolution, Competition, and Outlook

China's plug-in electric vehicle (PEV) market with stocks at 7.8 million is the world's largest in 2021, and it accounts for half of the global PEV growth in 2021. The PEV market in China has dramatically evolved since the pandemic in 2020: over 20% of all new PEV sales are from China by mid-2022. Recent features of PEV market dynamics, consumer acceptance, policies, and infrastructure have important implications for both the global energy market and manufacturing stakeholders. From the perspective of demand pull-supply push, this study analyzes China's PEV industry with a market dynamics framework by reviewing sales, product and brand, infrastructure, and government policies from the last few years and outlooking the development of the new government’s 14th Five-Year Plan (2021-2025). From the demand side, small-sized sedans and compact sport utility vehicles with increased electric ranges are both popular for PEVs, and the electric range of over 60% of new battery electric vehicles in 2021 has been longer than 400 km. From the supply side, although foreign brands like Tesla are still competitive, the products by Chinese domestic automakers like BYD are becoming more attractive and cannibalizing the high-end market. However, the production capacity and cost of PEVs may be limited by the upstream of the supply chain – the battery manufacturing and supply chain inflation. In addition, it is also uncertain how much sales demand impacts will be caused by the potential global economic recession. The government firmly supports electrification and decarbonization of the vehicle industry by emphasizing the importance of the vehicle industry for promoting the greenhouse gas net zero by 2060. The dual-credit policy is regarded as the most critical regulation in a bid to restrain fuel consumption and promote PEV share. Still, the market is facing some technological obstacles, such as battery safety and driving range anxiety, before real prosperity. In addition, the Chinese electric vehicle market is seeing a trend toward the development of new technologies such as vehicle-to-X, autonomous driving, and connected vehicles.

Hao, Xu↗

Evaluation of MOPITT Version 7 joint TIR–NIR X CO retrievals with TCCON

Observations of carbon monoxide (CO) from the Measurements Of Pollution In The Troposphere (MOPITT) instrument aboard the Terra spacecraft were expected to have an accuracy of 10 % prior to the launch in 1999. Here we evaluate MOPITT Version 7 joint (V7J) thermal-infrared and near-infrared (TIR–NIR) retrieval accuracy and precision and suggest ways to further improve the accuracy of the observations. We take five steps involving filtering or bias corrections to reduce scatter and bias in the data relative to other MOPITT soundings and ground-based measurements. (1) We apply a preliminary filtering scheme in which measurements over snow and ice are removed. (2) We find a systematic pairwise bias among the four MOPITT along-track detectors (pixels) on the order of 3–4 ppb with a small temporal trend, which we remove on a global scale using a temporally trended bias correction. (3) Using a small-region approximation (SRA), a new filtering scheme is developed and applied based on additional quality indicators such as the signal-to-noise ratio (SNR). After applying these new filters, the root-mean-squared error computed using the local median from the SRA over 16 years of global observations decreases from 3.84 to 2.55 ppb. (4) We also use the SRA to find variability in MOPITT retrieval anomalies that relates to retrieval parameters. We apply a bias correction to one parameter from this analysis. (5) After applying the previous bias corrections and filtering, we compare the MOPITT results with the GGG2014 ground-based Total Carbon Column Observing Network (TCCON) observations to obtain an overall global bias correction. These comparisons show that MOPITT V7J is biased high by about 6 %–8 %, which is similar to past studies using independent validation datasets on V6J. When using TCCON spectrometric column retrievals without the standard airmass correction or scaling to aircraft (WMO scale), the ground- and satellite-based observations overall agree to better than 0.5 %. GEOS-Chem data assimilations are used to estimate the influence of filtering and scaling to TCCON on global CO and tend to pull concentrations away from the prior fluxes and closer to the truth. We conclude with suggestions for further improving the MOPITT data products.

Hedelius, Jacob K. (ORCID:0000000320257519)↗

NOvA 2024 official data release (26.61E20 neutrino + 12.5E20 antineutrino)

This data release corresponds to the Bayesian 2024 analysis of NOvA $\nu_e$ appearance and $\nu_{\mu}$ disappearance data, corresponding to analysis described in https://arxiv.org/abs/2509.04361. File `NOvA_2024_data_histograms.root` contains data histograms for all the NOvA data samples. Exposure: * neutrino-enhanced beam: 26.61E20 protons on target * antineutrino-enhanced beam: 12.5E20 protons on target External constraints: * ss2th12=0.851, dm21=7.53e-5 are fixed at 2019 PDG values, with negligible effect on NOvA predictions. * ss2th13 & dm32: * RCDB1D: 1D constraint from Daya Bay for ss2th13, 0.0851+/-0.0024 * RCDB2D: Correlated 2D constraint from Daya Bay on ss2th13 & dm32, available in their official 2023 data release: https://journals.aps.org/prl/abstract/10.1103/PhysRevLett.130.161802#supplemental An additional file containing the predictions (`NOvA_2024_prediction_with_systs_histograms.root`) for all channels’ signal and background components computed at the NOvA best-fit oscillation parameters and systematic pull terms. Numu samples include the no-oscillation case as well. Please note that any fits performed with these histograms are not expected to exactly reproduce the official NOvA results as parameterizations of the numerous systematic uncertainties considered in the official fits are not included in this release. The zip file also contains the 2D credible interval contours, with details in a README.md

Sztuc, Artur [University Coll. London] (ORCID:0000↗

Continuous integration for concurrent MOOSE framework and application development on GitHub

For the past several years, Idaho National Laboratory’s MOOSE framework team has employed modern software engineering techniques (continuous integration, joint application/framework source code repos- itories, automated regression testing, etc.) in developing closed-source multiphysics simulation software (Gaston et al., Journal of Open Research Software vol. 2, article e10, 2014). In March 2014, the MOOSE framework was released under an open source license on GitHub, significantly expanding and diversifying the pool of current active and potential future contributors on the project. Despite this recent growth, the same philosophy of concurrent framework and application development continues to guide the project’s development roadmap. Several specific practices, including techniques for managing multiple repositories, conducting automated regression testing, and implementing a cascading build process are discussed in this short paper. Furthermore, special attention is given to describing the manner in which these practices naturally synergize with the GitHub API and GitHub-specific features such as issue tracking, Pull Requests, and project forks.

97 MATHEMATICS AND COMPUTING↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗

Size_resolved_ice_nucleating_particle_INP_concentrations_from_the_INPOP_campaign

Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the US DOE ARM AMF3 in Oliktok Point, AK from 1 Mar to 31 May 2017. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D, had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. The pump typically pulled 25 lpm at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 36,000 total L of air per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Following collection and transport from AMF3 to PI Creamean's laboratory in Boulder, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile bags and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 5 months after collection). Drop freezing assays (DFAs) were conducted on one daily sample per week of the study for all four stages, with daily samples analyzed from 22 - 29 May 2017. Immediately after removal from the freezer, 2 mL of ultrapure water was added with a single-use sterile syringe directly to the bags, then mixed using a vortex mixer for 2 hours at 500 rpm to resuspend particles from the PFA into the ultrapure water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected, but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen can be calculated as can the estimated INP concentration per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 1971.

4-stage DRUM aerosol collector (DA400),Aerosol imp↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM&rsquo;s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 &micro;m. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleating particle concentrations measured by the PNNL-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Pacific Northwest National Laboratory (PNNL). The PNNL-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Kulkarni et al. 2020). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Kulkarni, G., Hiranuma, N., M&ouml;hler, O., H&ouml;hler, K., China, S., Cziczo, D. J., & DeMott, P. J. (2020). A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: Assessment and performance study. Atmospheric Measurement Techniques, 13(12), 6631&ndash;6643. https://doi.org/10.5194/amt-13-6631-2020.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗

Fluorescent bioaerosol particle concentrations measured by the DU WIBS during the AGINSGP field experiment

Real-time, immersion mode ambient fluorescent bioaerosol concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a Wideband Integrated Bioaerosol Sensor (DMT Inc.; WIBS-4A). The WIBS-4A is an optical particle counter that also measures single particle fluorescence in three channels, along with particle asymmetry. Particles are grouped into different types depending on which channels they fluoresce in. The instrument was located in the guest instrument facility (GIF) and measured fluorescent particle concentrations from April 7th to April 29th. Data presented here are the concentrations for each particle type, binned in 5 minute increments. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Particles were dried using a silica diffusion dryer prior to analysis.

54 ENVIRONMENTAL SCIENCES↗

SCILLA nitrogen oxide (NOx) airborne data

Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.

NOx concentration↗

SCILLA ozone (O3) airborne data

Ozone mixing ratios in ppb are measured using a Teledyne API Model T400U. The analyzer uses UV absorption at 254 nm to determine O3 concentration. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, NOx, and H2O) and an oxidation flow reactor. The data were recorded at 0.1 Hz.

Ozone concentration↗

SCILLA Secondary Aerosol Volume Concentration Airborne Data

This data set contains secondary aerosol volume concentration in cubic micrometers per cubic centimeter (um^3/cm^3). The aerosol was generated in an oxidation flow reactor (OFR) and its volume concentration measured with a scanning mobility particle sizer (SMPS). Both components were designed and built at the University of California Riverside. Ambient particles were removed with a Teflon filter upstream of the OFR and then pure ammonium sulfate particles were added to create a stable aerosol surface area on which low-volatility oxidation products condense. High concentrations of hydroxyl radical (OH) formed inside the OFR accelerate the oxidative chemistry that would typically occur over a period of several days in the atmosphere, resulting in the production of secondary aerosol from precursor gases present in the ambient air. Concentrations of added ozone and water vapor were controlled to produce the desired and approximately constant level of photochemical aging. The reactor temperature was controlled, while the pressure was not, and was always slightly lower than that of the sampled outside air. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between the OFR and several gas analyzers (NOx, CO, O3, and H2O). Though not contained in these files, data from an aerosol mass spectrometer intermittently operated downstream of the OFR are also available.

{"secondary aerosol concentration",aerosol_concent↗

A Climatology of Dust Deposition in the Upper Colorado River Basin for February-May 1980-2023

This data set is a long-term climatology of the average monthly total dust deposition, wet and dry, for the months of February-May 1980-2023 pulled from the MERRA-2 reanalysis data set over the Upper Colorado River Basin. This data set can be used to study the long-term spatiotemporal patterns of dust deposition, especially on snow. This data set is associated with the preprint article “A multi-decadal climatology of dust-on-snow from wet deposition in the Upper Colorado River Basin”.

dry_dust_deposition↗