Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Fission Meter Information Barrier Attribute Measurement System: Task 1 Report: Document existing Fission Meter neutron IB system

An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements in a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment M403: Electrostatic charge

Experiment M403 was flown on the Gemini 4 and 5 spacecraft in an effort to discover whether the spacecraft could accumulate sufficient excess electric charge to constitute a hazard for later Gemini-Agena rendezvous missions. An attempt was made to measure the electric field terminating on a small area of the spacecraft retrograde adapter section and to calculate the total spacecraft charge from this measured field value. The Gemini 5 instrument was inhibited from responding to electric fields that corresponded to a charge on the spacecraft. However, readings were obtained on the Gemini 5 mission that were of as great or greater magnitude than those obtained on the Gemini 4 mission. This could be interpreted as an indication that the contribution of a net spacecraft charge to the Gemini 4 measurements was negligible. An operational measurement that was performed on a later rendezvous mission was indicative of a very small exchange of charge between the Gemini spacecraft and the Agena vehicle.

Lafferty, P. E.↗

Flammability Limits of Gases Under Low Gravity Conditions

The purpose of this combustion science investigation is to determine the effect of zero, fractional, and super gravity on the flammability limits of a premixed methane air flame in a standard 51 mm diameter flammability tube and to determine, if possible, the fluid flow associated with flame passage under zero-g conditions and the density (and hence, temperature) profiles associated with the flame under conditions of incipient extinction. This is accomplished by constructing an appropriate apparatus for placement in NASA's Lewis Research Center Lear Jet facility and flying the prescribed g-trajectories while the experiment is being performed. Data is recorded photographically using the visible light of the flame. The data acquired is: (1) the shape and propagation velocity of the flame under various g-conditions for methane compositions that are inside the flammable limits, and (2) the effect of gravity on the limits. Real time accelerometer readings for the three orthogonal directions are displayed in full view of the cameras and the framing rate of the cameras is used to measure velocities.

Strehlow, R. A.↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Learning to read aloud: A neural network approach using sparse distributed memory

An attempt to solve a problem of text-to-phoneme mapping is described which does not appear amenable to solution by use of standard algorithmic procedures. Experiments based on a model of distributed processing are also described. This model (sparse distributed memory (SDM)) can be used in an iterative supervised learning mode to solve the problem. Additional improvements aimed at obtaining better performance are suggested.

Joglekar, Umesh Dwarkanath↗

TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

60 APPLIED LIFE SCIENCES↗

Measuring error rates of mid-circuit measurements

High-fidelity mid-circuit measurements, which read out the state of specific qubits in a multiqubit processor without destroying them or disrupting their neighbors, are a critical component for useful quantum computing. They enable fault-tolerant quantum error correction, dynamic circuits, and other paths to solving classically intractable problems. But there are few methods to assess their performance comprehensively. In this work, we address this gap by introducing the first randomized benchmarking protocol that measures the rate at which mid-circuit measurements induce errors in many-qubit circuits. Using this protocol, we detect and eliminate previously undetected measurement-induced crosstalk in a 20-qubit trapped-ion quantum computer. Then, we use the same protocol to measure the rate of measurement-induced crosstalk error on a 27-qubit IBM Q processor, and quantify how much of that error is eliminated by dynamical decoupling.

Hothem, Daniel [Sandia National Laboratories (SNL-↗

A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

guppy i : a code for reducing the storage requirements of cosmological simulations

ABSTRACT As cosmological simulations have grown in size, the permanent storage requirements of their particle data have also grown. Even modest simulations present a major logistical challenge for the groups which run these boxes and researchers without access to high performance computing facilities often need to restrict their analysis to lower quality data. In this paper, we present guppy, a compression algorithm and code base tailored to reduce the sizes of dark matter-only cosmological simulations by approximately an order of magnitude. guppy is a ‘lossy’ algorithm, meaning that it injects a small amount of controlled and uncorrelated noise into particle properties. We perform extensive tests on the impact that this noise has on the internal structure of dark matter haloes, and identify conservative accuracy limits which ensure that compression has no practical impact on single-snapshot halo properties, profiles, and abundances. We also release functional prototype libraries in C, Python, and Go for reading and creating guppy data.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-145: Effects of Temporary Tachytherapy Inhibition Magnet On MOSFET Dose Measurements of Cardiovascular Implantable Electronic Devices (CIED) in Radiation Therapy Patients

Purpose: To determine the effects of temporary tachytherapy inhibition magnet on MOSFET dose measurements of cardiovascular implantable electronic devices (CIED) in radiation therapy patients. Methods: Infield and peripheral MOSFET dose measurements with 6MV photon beams were performed to evaluate dose to a CIED in the presence of a doughnut shaped temporary tachytherapy inhibition magnet. Infield measurements were done to quantify the effects of the magnetic field alone and shielding by the magnet. MOSFETs were placed inside a 20×20cm{sup 2} field at a depth of 3cm in the isocentre plane in the presence and absence of the magnet. Peripheral dose measurements were done to determine the impact of the magnet on dose to the CIED in a clinical setting. These measurements were performed at the centre, under the rim and half way between a 10×10cm{sup 2} field edge and the magnet with MOSFETS placed at the surface, 0.5cm and 1cm depths in the presence and absence of the magnet. Results: Infield measurements showed that effects of magnetic field on the MOSFET readings were within the 2% MOSFET dose measurement uncertainty; a 20% attenuation of dose under the magnet rim was observed. Peripheral dose measurements at the centre of the magnet show an 8% increase in surface dose and a 6% decrease in dose at 1cm depth. Dose under the magnet rim was reduced by approximately 68%, 45% and 25% for MOSFET placed at 0.0, 0.5 and 1.0cm bolus depths, respectively. Conclusions: The magnetic field has an insignificant effect on MOSFET dose measurements. Dose to the central region of CIED represented by centre of the magnet doughnut increases at the surface, and decreases at depths due to low energy scattering contributions from the magnet. Dose under the magnet rim, representing CIED edges, decreased significantly due to shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams

Purpose: The electron fluence inside a parallel-plate ionization chamber positioned in a water phantom and exposed to a clinical electron beam deviates from the unperturbed fluence in water in absence of the chamber. One reason for the fluence perturbation is the well-known “inscattering effect,” whose physical cause is the lack of electron scattering in the gas-filled cavity. Correction factors determined to correct for this effect have long been recommended. However, more recent Monte Carlo calculations have led to some doubt about the range of validity of these corrections. Therefore, the aim of the present study is to reanalyze the development of the fluence perturbation with depth and to review the function of the guard rings. Methods: Spatially resolved Monte Carlo simulations of the dose profiles within gas-filled cavities with various radii in clinical electron beams have been performed in order to determine the radial variation of the fluence perturbation in a coin-shaped cavity, to study the influences of the radius of the collecting electrode and of the width of the guard ring upon the indicated value of the ionization chamber formed by the cavity, and to investigate the development of the perturbation as a function of the depth in an electron-irradiated phantom. The simulations were performed for a primary electron energy of 6 MeV. Results: The Monte Carlo simulations clearly demonstrated a surprisingly large in- and outward electron transport across the lateral cavity boundary. This results in a strong influence of the depth-dependent development of the electron field in the surrounding medium upon the chamber reading. In the buildup region of the depth-dose curve, the in–out balance of the electron fluence is positive and shows the well-known dose oscillation near the cavity/water boundary. At the depth of the dose maximum the in–out balance is equilibrated, and in the falling part of the depth-dose curve it is negative, as shown here the first time. The influences of both the collecting electrode radius and the width of the guard ring are reflecting the deep radial penetration of the electron transport processes into the gas-filled cavities and the need for appropriate corrections of the chamber reading. New values for these corrections have been established in two forms, one converting the indicated value into the absorbed dose to water in the front plane of the chamber, the other converting it into the absorbed dose to water at the depth of the effective point of measurement of the chamber. In the Appendix, the in–out imbalance of electron transport across the lateral cavity boundary is demonstrated in the approximation of classical small-angle multiple scattering theory. Conclusions: The in–out electron transport imbalance at the lateral boundaries of parallel-plate chambers in electron beams has been studied with Monte Carlo simulation over a range of depth in water, and new correction factors, covering all depths and implementing the effective point of measurement concept, have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrically-cooled HPGe detector for advanced x-ray spectroscopy and imaging

High Purity Germanium (HPGe) detectors are used for high-resolution x- and gamma-ray spectroscopy. For their operation, the necessary cryogenic cooling is performed with liquid nitrogen or with electromechanical coolers. Although mature and industrialized solutions, most of HPGe detectors integrating electrical coolers present a limited spectroscopic performance due to the generated mechanical vibration and electromagnetic interference. This paper describes a novel HPGe detector, specifically designed to address the challenges of ultimate x-ray spectroscopy and imaging applications. Due to the stringent demands associated with nano-scale imaging in synchrotron applications, a custom-designed cryostat was built around a Canberra CP5-Plus electrical cooler featuring extremely low vibration levels and high cooling power. The heat generated by the cryo-cooler itself, as well as the electronics, is evacuated via an original liquid cooling circuit. This architecture can also be used to address high ambient temperature, which does not allow conventional cryo-coolers to work properly. The multichannel detector head can consist of a segmented monolithic HPGe sensor, or several closely packed sensors. Each sensor channel is read out by state-of-the-art pulse-reset preamplifiers in order to achieve excellent energy resolution for count rates in excess of 1 Mcps. The sensitive electronics are located in EMI-proof housings to avoid any interference from other devices on a beam-line. The front-end of the detector is built using selected high-purity materials and alloys to avoid any fluorescence effects. We present a detailed description of the detector design and we report on its performance. A discussion is also given on the use of electrically cooled HPGe detectors for applications requiring ultimate energy resolution, such as synchrotron, medicine or nuclear industry. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ESD Test Apparatus for Soldering Irons

ESDA (Electrostatic Discharge Association) ESD STM 13.1-2000 requires frequent testing of the voltage leakage from the tip of a soldering iron and the resistance from the tip of the soldering iron to the common point ground. Without this test apparatus, the process is time-consuming and requires several wires, alligator clips, or test probes, as well as additional equipment. Soldering iron tips must be tested for electrostatic discharge risks frequently, and this typically takes a lot of time in setup and testing. This device enables the operator to execute the full test in one minute or less. This innovation is a simple apparatus that plugs into a digital multimeter (DMM) and the Common Point Ground (CPG) reference. It enables the user to perform two of the electrostatic discharge tests required in ESD STM 13.1-2000. The device consists of a small black box with two prongs sticking out of one end, two inputs on the opposite end (one of the inputs is used to connect the reference CPG to the DMM), and a metal tab on one side. Inside the box are wires, several washers of various materials, and assembly hardware (nuts and screws/bolts). The device is a passive electronic component that is plugged into a DMM. The operator sets the DMM to read voltage. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The voltage is read and recorded. The operator switches the DMM to read resistance. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The resistance is recorded. If the recorded voltage and resistance are below a number stated in ESDA ESD STM 13.1-2000, the test is considered to pass. The device includes all the necessary wiring internal to its body so the operator does not need to do any independent wiring, except for grounding. It uses a stack of high-thermal-resistance washers to minimize the heat transfer from the soldering iron to the wiring used to measure the resistance and voltages. This minimizes thermal error. The device allows very rapid execution of a test that is performed frequently.

Sancho, Jose↗

Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive V that is, they do not require any on-board power supply such as batteries V and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. In general, RFID is a method of identifying items using radio waves to interrogate tags encoded with a unique identifier that are affixed to the items of interest. In the case of passive tags, only the interrogator, which transmits power to the tags in the form of radio-frequency electromagnetic radiation, requires access to a power supply. Passive RFID technologies are used today in many applications, including asset tracking and management, security and access control, and remote sensing. To date, most of the development and application in RFID technology has focused on either asset/inventory tracking and control or security and access control because these are the largest commercial application areas. Recently however, there has been growing interest in using passive RFID technology for remote sensing applications, and SAW devices are at the forefront of RFID sensing technology development. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of current generation tags limits the performance in a cluttered sensing environment. That is, as more SAW-based sensors are added to the environment, numerous tag responses are superimposed at the receiver and decoding all or even a subset of the telemetry becomes increasingly difficult. Background clutter generated by reflectors other than the sensors themselves is also a problem, as is multipath interference and signal distortion, but the limiting factor in many remote sensing applications can be expected to be tag mutual interference. This problem may be greatly mitigated by proper design of the SAW tag waveform, but that remains an open research problem, and in the meantime, several other related questions remain to be answered including: (1) What are the fundamental relationships between tag parameters such as bit-rate, time-bandwidth-product, SNR, and achievable collision resolution? (2) What are the differences in optimal or near-optimal interrogator designs between noise-limited environments and interference-limited environments? (3) What are the performance characteristics of different interrogator designs in term of parameters such as transmitter power level, range, and number of interfering tags? In this paper, we will present the results of a research effort aimed at providing at least partial answers to all of these questions.

Barton Richard J.↗

SU-D-209-04: Raise Your Table: An Effective Way to Reduce Radiation Dose for Fluoroscopy

Purpose: Patient table height plays an important role in estimating patient skin dose for interventional radiology (IR) procedures, because the patient’s skin location is dependent on the height of table. Variation in table height can lead to as much as 150% difference in skin dose for patient exams with similar air kerma meter readings. In our facility, IR procedural workflow was recently changed to require the IR physicians to confirm the patient table height before the procedure. The patient table height data was collected before and after this workflow change to validate the implementation of this practice. Methods: Table height information was analyzed for all procedures performed in three IR rooms, which were impacted by the workflow change, covering three months before and after the change (Aug 2015 to Jan 2016). In total, 442, 425, and 390 procedures were performed in these three rooms over this time period. There were no personnel or procedure assignment changes during the six-month period of time. Statistical analysis was performed for the average table height changes before and after the workflow change. Results: For the three IR rooms investigated, after the workflow change, the average table heights were increased by 1.43 cm (p=0.004084), 0.66 cm (p=0.187089), and 1.59 cm (p=0.002193), providing a corresponding estimated skin dose savings of 6.76%, 2.94% and 7.62%, respectively. After the workflow change, the average table height was increased by 0.95 cm, 0.63 cm, 0.55 cm, 1.07 cm, 1.12 cm, and 3.36 cm for the six physicians who routinely work in these three rooms. Conclusion: Consistent improvement in table height settings has been observed for all IR rooms and all physicians following a simple workflow change. This change has led to significant patient dose savings by making physicians aware of the pre-procedure table position.

60 APPLIED LIFE SCIENCES↗

Modeling Personalized Email Prioritization: Classification-based and Regression-based Approaches

Email overload, even after spam filtering, presents a serious productivity challenge for busy professionals and executives. One solution is automated prioritization of incoming emails to ensure the most important are read and processed quickly, while others are processed later as/if time permits in declining priority levels. This paper presents a study of machine learning approaches to email prioritization into discrete levels, comparing ordinal regression versus classier cascades. Given the ordinal nature of discrete email priority levels, SVM ordinal regression would be expected to perform well, but surprisingly a cascade of SVM classifiers significantly outperforms ordinal regression for email prioritization. In contrast, SVM regression performs well -- better than classifiers -- on selected UCI data sets. This unexpected performance inversion is analyzed and results are presented, providing core functionality for email prioritization systems.

97 MATHEMATICS AND COMPUTING↗

Complex Parsing for In-Network Acceleration of High-Energy Physics Experiments

This paper describes a novel application and evaluation of programmable networking in High-Energy Physics (HEP): a complete parser for the custom packet format used by Fermilab’s DUNE experiment. Notably, this parser is implemented on a Tofino programmable network switch and evaluated on the FABRIC testbed by using network traffic generated by the ICEBERG DUNE prototype. The parsed network traffic consists of Jumbo Ethernet frames that contain digitizations of sensor readings from ICEBERG’s detector.This work is an early investigation into providing in-network processing support for HEP experiments. The paper describes DUNE’s custom packet format, the challenges encountered when implementing a parser for that format, and an exploration of the techniques that are needed to overcome those challenges. We identify performance bottlenecks and discuss directions for future research.

Sagstad, Bjoern [IIT, Chicago] (ORCID:000900033610↗

CMS Storage Performance with RNTuple

CMS is transitioning to use ROOT’s new RNTuple data storage format for the files CMS will write in the HL-LHC era. Based on initial tests, CMS expects faster I/O and smaller files compared to the present TTree storage format. This contribution will show a comprehensive performance comparison between RNTuple and TTree I/O using CMS AOD and MiniAOD data formats as test cases for both simulation and collision data corresponding to similar data taking conditions of LHC Run 3. Quantities such as the resulting file size, the memory usage of the I/O components, and the rate of events being read from a file or written to a file will be measured. CMS’ data processing relies heavily on reading files over the local or wide area networks. The file read patterns are important because the latencies have been seen to influence the total production job times. Therefore a study on the file read patterns will be conducted by recording traces of the offset, size, and timestamp of each read request for both RNTuple and TTree. The behavior of network reads will be mimicked by reading local files where artificial latency will be added to the read requests. The effect of different latency values on the job times will be studied.

Jones, Christopher D. [Fermilab]↗