Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The relationships between residual stress relaxation and texture development in AZ31 Mg alloys via the vibratory stress relief technique

A systematic study of residual stress relaxation and the texture evolution of cold-rolled AZ31 Mg alloys using the vibratory stress relief technique with a simple cantilever beam vibration system was performed using a high-resolution X-ray diffractometer and a portable X-ray residual stress analyzer. The effects of vibrational stress excitation on the surface residual stress distribution and on the texture of pole figures (0002) occurring during the vibratory stress relief were examined. Compared with the effects corresponding to the same alloy under non-vibration condition, it can be observed that the uniform surface residual stress distribution and relaxation of the compressive residual stress in the stress concentration zone were observed rather than all of the residual stresses being eliminated. Furthermore, with an increase in the vibrational aging time, the compressive residual stress, texture density, and (0002) preferred orientation increased first and then decreased. It should be underlined that the vibratory stress relief process for the vibrational aging time of more than 10 min is able to weaken the strong basal textures of AZ31 Mg alloys, which is valuable for enhancement of their formability and is responsible for an almost perfect 3D-Debye–Scherrer ring. - Highlights: • 3D-Debye ring about VSR technique is not discussed in the existing literature. • A newly developed VSR method is suitable for small or thin workpieces. • The cosα method accurately and effectively determines the residual stresses. • The VSR technique is valuable for enhancement of their formability. • The texture and preferred orientation change with the vibrational aging time.

36 MATERIALS SCIENCE↗

A prospective feasibility study evaluating the role of multimodality imaging and liquid biopsy for response assessment in locally advanced rectal carcinoma

Purpose: Colorectal cancer is a commonly encountered disease that poses several diagnostic and therapeutic challenges. The inherent heterogeneity of tumor biology and propensity to relapse despite “curative” resection pose significant challenges with regard to response assessment. Although MR imaging already plays a key role in primary staging of patients with rectal carcinoma, its reliability in restaging after neoadjuvant therapy is debatable (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). Therefore, there is significant interest in developing additional methods which may improve diagnostic accuracy. This study aims to evaluate the role of multimodality imaging and liquid biopsy in therapeutic response assessment. Methods: Seventeen patients were enrolled into the study over a span of 24 months. All underwent hybrid PET-MRI and CT-perfusion (CT-P), prior to and following neoadjuvant therapy for locally advanced rectal carcinoma. Twelve of the 17 patients also underwent liquid biopsy, which consisted of blood sampling and analysis of circulating tumor cells (CTCs) and extracellular vesicles (EVs), including cell fragments and microparticles (MPs), using the Cell Search System (Menarini Silicon Biosystems). SUV, DWI, and ADC were calculated during PET-MRI, and several parameters were evaluated during CT-perfusion, including average perfusion, blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), contrast extraction efficiency (E), and K-trans (K). Changes observed pre- and post-neoadjuvant therapy in each modality were compared to tumor response at histopathology using a modified Ryan tumor regression grading system. Results: Of the 17 patients included in the study, 14 were classified as non-responders, and 3 were classified as responders as determined by the modified Ryan Tumor Regression Grade (TRG) scoring system (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). When combined, blood markers and CT-P parameters (mean transit time (MTT), K-trans, and permeability-surface area product (PS)) produced the strongest models (p < 0.01). PET (SUV measurement) combined with CT-P-derived K-trans produced a marginally significant (p = 0.057) model for predicting response. MRI-derived ADC value did not provide a significant model for response prediction. Conclusion: A model of CT-P parameters plus liquid biopsy more accurately predicts tumor response than PET-MRI, CT-P alone, or liquid biopsy alone. These results suggest that in the evaluation of treatment response, liquid biopsy could provide additional information to functional imaging modalities such as CT-P and should therefore be explored further in a trial with larger sample size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of groundwater artificial recharge systems using a genetic algorithm: a case study in Beijing, China

An optimization approach is used for the operation of groundwater artificial recharge systems in an alluvial fan in Beijing, China. The optimization model incorporates a transient groundwater flow model, which allows for simulation of the groundwater response to artificial recharge. The facilities’ operation with regard to recharge rates is formulated as a nonlinear programming problem to maximize the volume of surface water recharged into the aquifers under specific constraints. This optimization problem is solved by the parallel genetic algorithm (PGA) based on OpenMP, which could substantially reduce the computation time. To solve the PGA with constraints, the multiplicative penalty method is applied. In addition, the facilities’ locations are implicitly determined on the basis of the results of the recharge-rate optimizations. Two scenarios are optimized and the optimal results indicate that the amount of water recharged into the aquifers will increase without exceeding the upper limits of the groundwater levels. Optimal operation of this artificial recharge system can also contribute to the more effective recovery of the groundwater storage capacity.

58 GEOSCIENCES↗

The Vital Function of Fe3O4@Au nanocomposites for Hydrolase Biosensor Design and Its Application in Detection of Methyl Parathion

A nanocomposite of gold nanoparticles (AuNPs) decorating a magnetic Fe3O4 core was synthesized using cysteamine (SH–NH2) as linker, and characterized by TEM, XPS, UV and electrochemistry. Then a hydrolase biosensor, based on self-assembly of methyl parathion hydrolase (MPH) on the Fe3O4@Au nanocomposite, was developed for sensitive and selective detection of the organophosphorus pesticide (OP) methyl parathion. The magnetic nanocomposite provides an easy way to construct the enzyme biosensor by simply exerting an external magnetic field, and also provides a simple way to renew the electrode surface by removing the magnet. Unlike inhibition-based enzyme biosensors, the hydrolase is not poisoned by OPs and thus is reusable for continuous measurement. AuNPs not only provide a large surface area, high loading efficiency and fast electron transfer, but also stabilize the enzyme through electrostatic interactions. The MPH biosensor shows rapid response and high selectivity for detection of methyl parathion, with a linear range from 0.5 to 1000 ng/mL and a detection limit of 0.1 ng/mL. It also shows acceptable reproducibility and stability. The simplicity and ease of operation of the proposed method has great potential for on-site detection of P–S containing pesticides and provides a promising strategy to construct a robust biosensor.

Au nanoparticles↗

Measurable radiation levels around individuals externally contaminated by nuclear fallout

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger–Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235 U-fueled device.

61 RADIATION PROTECTION AND DOSIMETRY↗

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for Phase Transitions in Artificial Kagome Spin Ice

Artificial Kagome spin ice is a metasurface consisting of small islands of polarizable magnets. These islands can be oriented by an external magnetic field applied in the same plane as the metasurface. By subsequently applying a relatively weaker field in the opposite direction of the initial field, a portion of the magnets in the lattice can be repolarized or “flipped” the other way. These flips cause instabilities in a previously uniformly aligned lattice, causing the system to interact with itself and induce changes in the overall magnetization of the metasurface. This Summer, my goal was to use this phenomenon to discern whether or not these systems could undergo a phase transition caused only by the initial change of the external magnetic field. Based on previous datasets that indicated that such a transition was observable, my task was to find and reproduce this potential phenomena. This process was conducted by repeating measurements on the system by using an external magnet to align the spin ice and then using Magnetic Force Microscopy (MFM) to probe the surface of the material to understand the changes in the magnetization over time. This report will discuss the characteristics of artificial Kagome spin ice, the methodology used to induce phase transitions, and the image processing methods used to understand the results. Although no reproducible evidence of a phase transition was found during the Summer, we were able to successfully reproduce short-term responses in the spin ice, as well as plot a hysteresis curve of the material.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The application of general aerodynamic lifting surface elements to problems in unsteady transonic flow

A study was conducted to investigate the feasibility of using combined subsonic and supersonic linear theory as a means for solving unsteady transonic flow problems in an economical and yet realistic manner. With some modification, existing linear theory methods are combined into a single program and a simple algorithm is derived for determining interference between lifting surface elements of different Mach number. The method is applied to a wide variety of problems for which measured unsteady pressure distributions and Mach number distributions are available. By comparing theory and experiment, the transonic method solutions show a significant improvement over uniform flow solutions. It is concluded that with these refinements the method will provide a means for performing realistic transonic flutter and dynamic response analyses at costs which are compatible with current linear theory based solutions.

Cunningham, A. M., Jr.↗

Transfer matrix approach to layered systems with axial symmetry

The stress and displacement distribution in a layered medium is found by means of transfer matrices. The surface loading exhibits axial symmetry, and each layer is of infinite extent in the horizontal direction, of constant depth, and is considered to be linearly elastic, homogeneous, and isotropic. The method developed has the built-in advantage of enforcing interface continuity conditions automatically. Its application to layered composites shows the flexibility with which it predicts the local as well as the global response of the medium.

Bahar, L. Y.↗

Fracture mechanics; Proceedings of the 22nd National Symposium, Atlanta, GA, June 26-28, 1990. Vols. 1 & 2

Current research on fracture mechanics is reviewed, focusing on ductile fracture; high-temperature and time-dependent fracture; 3D problems; interface fracture; microstructural aspects of fatigue and fracture; and fracture predictions and applications. Particular attention is given to the determination and comparison of crack resistance curves from wide plates and fracture mechanics specimens; a relationship between R-curves in contained and uncontained yield; the creep crack growth behavior of titanium alloy Ti-6242; a crack growth response in three heat resistant materials at elevated temperature; a crack-surface-contact model for determining effective-stress-intensity factors; interfacial dislocations in anisotropic bimaterials; an effect of intergranular crack branching on fracture toughness evaluation; the fracture toughness behavior of exservice chromium-molybdenum steels; the application of fracture mechanics to assess the significance of proof loading; and a load ratio method for estimating crack extension.

Ernst, Hugo A.↗

Signal Processing and Calibration of Continuous-Wave Focused CO2 Doppler Lidars for Atmospheric Backscatter Measurement

Two continuous-wave(CW)focused C02 Doppler lidars (9.1 and 10.6 micrometers) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic and spectrum analyzer and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is approximately 3 x 10(exp -12)/m/sr at 9.1 micrometers and approximately 9 x 10(exp -12)/m/sr at 10.6 micrometers. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6 micrometer lidar intercomparisons were made. Measurements at 9.1 micrometers, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope C-12 O(2)-18 gas.

Rothermel, Jeffry↗

A Study of Penalty Function Methods for Constraint Handling with Genetic Algorithm

COMETBOARDS (Comparative Evaluation Testbed of Optimization and Analysis Routines for Design of Structures) is a design optimization test bed that can evaluate the performance of several different optimization algorithms. A few of these optimization algorithms are the sequence of unconstrained minimization techniques (SUMT), sequential linear programming (SLP) and the sequential quadratic programming techniques (SQP). A genetic algorithm (GA) is a search technique that is based on the principles of natural selection or "survival of the fittest". Instead of using gradient information, the GA uses the objective function directly in the search. The GA searches the solution space by maintaining a population of potential solutions. Then, using evolving operations such as recombination, mutation and selection, the GA creates successive generations of solutions that will evolve and take on the positive characteristics of their parents and thus gradually approach optimal or near-optimal solutions. By using the objective function directly in the search, genetic algorithms can be effectively applied in non-convex, highly nonlinear, complex problems. The genetic algorithm is not guaranteed to find the global optimum, but it is less likely to get trapped at a local optimum than traditional gradient-based search methods when the objective function is not smooth and generally well behaved. The purpose of this research is to assist in the integration of genetic algorithm (GA) into COMETBOARDS. COMETBOARDS cast the design of structures as a constrained nonlinear optimization problem. One method used to solve constrained optimization problem with a GA to convert the constrained optimization problem into an unconstrained optimization problem by developing a penalty function that penalizes infeasible solutions. There have been several suggested penalty function in the literature each with there own strengths and weaknesses. A statistical analysis of some suggested penalty functions is performed in this study. Also, a response surface approach to robust design is used to develop a new penalty function approach. This new penalty function approach is then compared with the other existing penalty functions.

Ortiz, Francisco↗

Electrically conductive proppant and methods for detecting, locating and characterizing the electrically conductive proppant

Electrically conductive proppants and methods for detecting, locating, and characterizing same are provided. The electrically conductive proppant can include a substantially uniform coating of an electrically conductive material having a thickness of at least 500 nm. The method can include injecting a hydraulic fluid into a wellbore extending into a subterranean formation at a rate and pressure sufficient to open a fracture therein, injecting into the fracture a fluid containing the electrically conductive proppant, electrically energizing the earth at or near the fracture, and measuring three dimensional (x, y, and z) components of electric and magnetic field responses at a surface of the earth or in an adjacent wellbore.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrically conductive proppant and methods for detecting, locating and characterizing the electrically conductive proppant

Electrically conductive proppants and methods for detecting, locating, and characterizing same are provided. The electrically conductive proppant can include a substantially uniform coating of an electrically conductive material having a thickness of at least 500 nm. The method can include injecting a hydraulic fluid into a wellbore extending into a subterranean formation at a rate and pressure sufficient to open a fracture therein, injecting into the fracture a fluid containing the electrically conductive proppant, electrically energizing the earth at or near the fracture, and measuring three dimensional (x, y, and z) components of electric and magnetic field responses at a surface of the earth or in an adjacent wellbore.

47 OTHER INSTRUMENTATION↗

Electrically conductive proppant and methods for detecting, locating and characterizing the electrically conductive proppant

Electrically conductive proppants and methods for detecting, locating, and characterizing same are provided. The electrically conductive proppant can include a substantially uniform coating of an electrically conductive material having a thickness of at least 500 nm. The method can include injecting a hydraulic fluid into a wellbore extending into a subterranean formation at a rate and pressure sufficient to open a fracture therein, injecting into the fracture a fluid containing the electrically conductive proppant, electrically energizing the earth at or near the fracture, and measuring three dimensional (x, y, and z) components of electric and magnetic field responses at a surface of the earth or in an adjacent wellbore.

Cannan, Chad↗

SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.

60 APPLIED LIFE SCIENCES↗

Shock compression response of cold-rolled Ni/Al multilayer composites

Uniaxial strain, plate-on-plate impact experiments were performed on cold-rolled Ni/Al multilayer composites and the resulting Hugoniot was determined through time-resolved measurements combined with impedance matching. The experimental Hugoniot agreed with that previously predicted by two dimensional (2D) meso-scale calculations. Additional 2D meso-scale simulations were performed using the same computational method as the prior study to reproduce the experimentally measured free surface velocities and stress profiles. Finally, these simulations accurately replicated the experimental profiles, providing additional validation for the previous computational work.

36 MATERIALS SCIENCE↗

Cross‐Instrument Comparison of MapCam and OVIRS on OSIRIS‐REx

Two of the instruments onboard the OSIRIS-REx spacecraft, the MapCam color imager and the OVIRS visible and 20 infrared spectrometer, observed the surface of asteroid (101955) Bennu in partially overlapping wavelengths. 21 Significant scientific advances have been enabled by using data from these two instruments in tandem, but a robust 22 statistical understanding of their relationship is needed for future analyses to cross-compare their data as accurately 23 and sensitively as possible. Here we present a cross-instrument comparison of data acquired by MapCam and 24 OVIRS, including methods and results for all global and site-specific observation campaigns in which both 25 instruments were active. In our analysis, we consider both the absolute radiometric offset and the relative 26 (normalized) variation between the two instruments; we find that both depend strongly on the photometric and 27 instrumental conditions during the observation. The two instruments have a large absolute offset (>15%) due to their 28 independent radiometric calibrations. However, they are very consistent (relative offset as low as 1%) when each 29 instrument’s response is normalized at a single wavelength, particularly at low phase angles where shadows on 30 Bennu’s rough surface are minimized. We recommend using the global datasets acquired at 12:30 pm local solar 31 time for cross-comparisons; data acquired at higher phase angles have larger uncertainties.

D R Golish↗