Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The AGORA High-Resolution Galaxy Simulations Comparison Project

Context. Satellite galaxies experience multiple physical processes when interacting with their host halos, often leading to the quenching of star formation. In the Local Group, satellite quenching has been shown to be highly efficient, affecting nearly all satellites except the most massive ones. While recent surveys study Milky Way-analogs to assess how representative our Local Group is, the dominant physical mechanisms behind satellite quenching in Milky Way-mass halos remain under debate. Aims. We analyze satellite quenching within the same Milky Way-mass halo simulated using various widely used astrophysical codes, each using different hydrodynamic methods and implementing different supernovae feedback recipes. The goal is to determine whether quenched fractions, quenching timescales, and the dominant quenching mechanisms are consistent across codes or if they show sensitivity to the specific hydrodynamic method and supernovae feedback physics employed. Methods. We used a subset of high-resolution cosmological zoom-in simulations of a Milky Way-mass halo from the multiple-code AGORA CosmoRun suite. Our analysis focuses on comparing satellite quenching across the different models and against observational data. We also analyzed the dominant mechanisms driving satellite quenching in each model. Results. We find that the quenched fraction is consistent with the latest SAGA Survey results within its 1σ host-to-host scatter across all the models. Regarding quenching timescales, all the models reproduce the trend observed in the ELVES survey, Local Group observations, and previous simulations: The less massive the satellite, the shorter its quenching timescale. All of our models converge on the dominant quenching mechanisms: Strangulation halts cold gas accretion in all satellites, while ram pressure stripping is the predominant mechanism for gas removal, and it is particularly effective in satellites with M * <10 8 M ⊙ . Nevertheless, the efficiency of the stripping mechanisms differs among the codes, showing a strong sensitivity to the different supernovae feedback implementations and/or hydrodynamic methods employed.

Local Group↗

Two-layer transient heat transfer using impulse response methods

Solutions to the inverse heat conduction problem (IHCP) are methods that can be used to quantify surface heat flux in multi-layer materials for components in which there are limited subsurface (internal) temperature measurements, such as coated components. A critical consideration is to capture high frequency fluctuations using a practical heat flux sensor. To that end, this paper highlights key parameters for calculating accurate surface heat transfer. Specifically, this research extends the available solutions to the IHCP for multi-substrate structures through an impulse response methodology. The sensitivity of the impulse method was quantified with respect to practical measurements. Further, when compared to the inverse case, the impulse method resulted in lower errors when calculating surface heat flux over a range of conditions. Overall, this work provides a foundation for deducing heat flux from a subsurface heat flux sensor while maintaining a high-frequency response.

42 ENGINEERING↗

Ultrafast Imaging of Molecules with Electron Diffraction

Photoexcited molecules convert light into chemical and mechanical energy through changes in electronic and nuclear structure that take place on femtosecond timescales. Gas phase ultrafast electron diffraction (GUED) is an ideal tool to probe the nuclear geometry evolution of the molecules and complements spectroscopic methods that are mostly sensitive to the electronic state. GUED is a passive probing tool that does not alter the molecular properties during the probing process and is sensitive to the spatial distribution of charge in the molecule, including both electrons and nuclei. Improvements in temporal resolution have enabled GUED to capture coherent nuclear motions in molecules in the excited and ground electronic states with femtosecond and subangstrom resolution. Here we present the basic theory of GUED and explain what information is encoded in the diffraction signal, review how GUED has been used to observe coherent structural dynamics in recent experiments, and discuss the advantages and limitations of the method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Modification of Silicon Pillar Arrays To Enhance Fluorescence Detection of Uranium and DNA

There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Here in this paper, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytes were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 μL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.

36 MATERIALS SCIENCE↗

Two-Sided Coded Aperture Imaging Without a Detector Plane

We introduce a novel design for a two-sided, coded-aperture, gamma-ray imager suitable for use in stand off detection of orphan radioactive sources. The design is an extension of an active-mask imager that would have three active planes of detector material, a central plane acting as the detector for two (active) coded-aperture mask planes, one on either side of the detector plane. In the new design the central plane is removed and the mask on the left (right) serves as the detector plane for the mask on the right (left). This design reduces the size, mass, complexity, and cost of the overall instrument. In addition, if one has fully position-sensitive detectors, then one can use the two planes as a classic Compton camera. This enhances the instrument's sensitivity at higher energies where the coded-aperture efficiency is decreased by mask penetration. A plausible design for the system is found and explored with Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulations of microchannel plate detectors. I. Steady-state voltage bias results

X-ray detectors based on straight-channel microchannel plates (MCPs) are a powerful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy in the fields of laser-driven inertial confinement fusion and fast Z-pinch experiments. Understanding the behavior of microchannel plates as used in such detectors is critical to understanding the data obtained. The subject of this paper is a Monte Carlo computer code we have developed to simulate the electron cascade in a MCP under a static applied voltage. Also included in the simulation is elastic reflection of low-energy electrons from the channel wall, which is important at lower voltages. When model results were compared to measured MCP sensitivities, good agreement was found. Spatial resolution simulations of MCP-based detectors were also presented and found to agree with experimental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-channel method for measuring losses in a ring optical resonator at a wavelength of 632.8 nm

A two-channel method is proposed for measuring losses in an optical ring resonator (RR), in which eigenmodes (counterpropagating waves) are excited by means of a Zeeman ring He – Ne laser with a wavelength of 632.8 nm. The measured frequency splitting of the laser counterpropgating waves is used to determine the absolute value of losses in an exemplary RR. The value of losses in the measured RR is determined by comparing the resonance width of the output radiation intensity with the resonance width of the radiation intensity for an exemplary resonator. The algorithm of intensity resonance processing takes into account the distortions caused by the dynamic effect, which allows a significant increase in the accuracy (up to 1% – 2%) and sensitivity of the proposed method. The measured losses in the RR with a perimeter of 28 cm constitute 80 – 5000 ppm. (resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on negative incident photon-to-electron conversion efficiency of quantum dot-sensitized solar cells

Recently, negative signals are frequently observed during the measuring process of monochromatic incident photon-to-electron conversion efficiency (IPCE) for sensitized solar cells by DC method. This phenomenon is confusing and hindering the reasonable evaluation of solar cells. Here, cause of negative IPCE values is studied by taking quantum dot-sensitized solar cell (QDSC) as an example, and the accurate measurement method to avoid the negative value is suggested. The negative background signals of QDSC without illumination are found the direct cause of the negative IPCE values by DC method. Ambient noise, significant capacitance characteristics, and uncontrolled electrochemical reaction all can lead to the negative background signals. When the photocurrent response of device under monochromatic light illumination is relatively weak, the actual photocurrent signals will be covered by the negative background signals and the resulting IPCE values will appear negative. To improve the signal-to-noise ratio, quasi-AC method is proposed for IPCE measurement of solar cells with weak photocurrent response based on the idea of replacing the absolute values by the relative values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TaN resistor process development and integration.

This paper describes the development and implementation of an integrated resistor process based on reactively sputtered tantalum nitride. Image reversal lithography was shown to be a superior method for liftoff patterning of these films. The results of a response surface DOE for the sputter deposition of the films are discussed. Several approaches to stabilization baking were examined and the advantages of the hot plate method are shown. In support of a new capability to produce special-purpose HBT-based Small-Scale Integrated Circuits (SSICs), we developed our existing TaN resistor process, designed for research prototyping, into one with greater maturity and robustness. Included in this work was the migration of our TaN deposition process from a research-oriented tool to a tool more suitable for production. Also included was implementation and optimization of a liftoff process for the sputtered TaN to avoid the complicating effects of subtractive etching over potentially sensitive surfaces. Finally, the method and conditions for stabilization baking of the resistors was experimentally determined to complete the full implementation of the resistor module. Much of the work to be described involves the migration between sputter deposition tools - from a Kurt J. Lesker CMS-18 to a Denton Discovery 550. Though they use nominally the same deposition technique (reactive sputtering of Ta with N{sup +} in a RF-excited Ar plasma), they differ substantially in their design and produce clearly different results in terms of resistivity, conformity of the film and the difference between as-deposited and stabilized films. We will describe the design of and results from the design of experiments (DOE)-based method of process optimization on the new tool and compare this to what had been used on the old tool.

36 MATERIALS SCIENCE↗

In-plane ultrasonic needle tracking using a fiber-optic hydrophone

Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.

60 APPLIED LIFE SCIENCES↗

Combining X-ray Absorption and X-ray Diffraction Techniques for in Situ Studies of Chemical Transformations in Heterogeneous Catalysis:Advantages and Limitations

Recent advances in catalysis instrumentations include synchrotron-based facilities where time-resolved X-ray scattering and absorption techniques are combined in the same in situ or operando experiment to study catalysts at work. To evaluate the advances and limitations of this method, we performed a series of experiments at the new XAFS/XRD instrument in the National Synchrotron Light Source. Nearly simultaneous X-ray diffraction (XRD) and X-ray absorption fine-structure (XAFS) measurements of structure and kinetics of several catalysts under reducing or oxidizing conditions have been performed and carefully analyzed. For CuFe{sub 2}O{sub 4} under reducing conditions, the combined use of the two techniques allowed us to obtain accurate data on kinetics of nucleation and growth of metallic Cu. For the inverse catalyst CuO/CeO{sub 2} that underwent isothermal reduction (with CO) and oxidation (with O{sub 2}), the XAFS data measured in the same experiment with XRD revealed strongly disordered Cu species that went undetected by diffraction. These and other examples emphasize the unique sensitivity of these two complementary methods to follow catalytic processes in the broad ranges of length and time scales.

43 PARTICLE ACCELERATORS↗

Assessing pulsar timing array sensitivity to gravitational wave bursts with memory

Highly energetic astrophysical phenomena like supermassive black hole binary (SMBHB) mergers are predicted to emit prodigious amounts of gravitational waves (GWs). An anticipated component of the gravitational waveform known as 'memory' is permanent and nonoscillatory. For SMBHB mergers, the memory is created primarily during the most violent moments of the inspiral immediately preceding the final plunge and ring-down when the strongest gravitational fields are at work and the nonlinearities of general relativity are most pronounced. The essentially time-domain nature of memory makes it forbiddingly difficult to detect with ground based GW detectors, leaving pulsar timing array (PTA) experiments as the most promising means by which it may be detected and studied. In this paper, we discuss how GW bursts with memory (BWMs) influence pulsar timing experiments and develop methods to assess how sensitive modern timing efforts are to such GW events. We discuss how PTA searches for BWMs can be used to constrain the rate of BWMs and how these constraints relate to information regarding the population of SMBHBs.

79 ASTRONOMY AND ASTROPHYSICS↗

29Si NMR in solid state with CPMG acquisition under MAS

A remarkable enhancement of sensitivity can be often achieved in {sup 29}Si solid-state NMR by applying the well-known Carr-Purcell-Meiboom-Gill (CPMG) train of rotor-synchronized {pi} pulses during the detection of silicon magnetization. Here, several one- and two-dimensional (1D and 2D) techniques are used to demonstrate the capabilities of this approach. Examples include 1D {sup 29}Si{l_brace}X{r_brace} CPMAS spectra and 2D {sup 29}Si{l_brace}X{r_brace} HETCOR spectra of mesoporous silicas, zeolites and minerals, where X = {sup 1}H or {sup 27}Al. Data processing methods, experimental strategies and sensitivity limits are discussed and illustrated by experiments. The mechanisms of transverse dephasing of {sup 29}Si nuclei in solids are analyzed. Fast magic angle spinning, at rates between 25 and 40 kHz, is instrumental in achieving the highest sensitivity gain in some of these experiments. In the case of {sup 29}Si-{sup 29}Si double-quantum techniques, CPMG detection can be exploited to measure homonuclear J-couplings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CORRLA-RS

The CORRLA-RS package provides a suite of statistical methods for sampling multidimensional distributions and to conduct sensitivity and correlation analysis of large scale data in the Rust programming language. The software provides a unique solution to multidimensional constrained sampling problems utilizing a combination of parallelized Markov Chain Monte Carlo methods and traditional rejection sampling. The sensitivity and correlation analysis methods are backed by a high performance randomized singular value decomposition implementation which enables datasets larger than the random access memory (RAM) size to be analyzed. Additionally, CORRLA-RS implements the active subspace identification method using a KD-Tree and the randomized singular value decomposition acting in concert.

Gurecky, William [Oak Ridge National Laboratory (O↗

Adaptive immersed isogeometric level-set topology optimization

Here, this paper presents for the first time an adaptive immersed approach for level-set topology optimization using higher-order truncated hierarchical B-spline discretizations for design and state variable fields. Boundaries and interfaces are represented implicitly by the iso-contour of one or multiple level-set functions. An immersed finite element method, the eXtended IsoGeometric Analysis, is used to predict the physical response. The proposed optimization framework affords different adaptively refined higher-order B-spline discretizations for individual design and state variable fields. The increased continuity of higher-order B-spline discretizations together with local refinement enables direct control over the accuracy of the representation of each field while simultaneously reducing computational cost compared to uniformly refined discretizations. A flexible mesh adaptation strategy enables local refinement based on geometric measures or physics-based error indicators. These adaptive discretization and analysis approaches are integrated into gradient-based optimization schemes, evaluating the design sensitivities using the adjoint method. Numerical studies illustrate the features of the proposed framework with static, linear elastic, multi-material, two- and three-dimensional problems. The examples provide insight into the effect of refining the design variable field on the optimization result and the convergence rate of the optimization process. Using coarse higher-order B-spline discretizations for level-set fields promotes the development of smooth designs and suppresses the emergence of small features. Moreover, adaptive mesh refinement for state variable fields results in a reduction of overall computational cost. Higher-order B-spline discretizations are especially interesting when evaluating gradients of state variable fields due to their higher inter-element continuity.

36 MATERIALS SCIENCE↗

Evaluation of Density-Functional Tight-Binding Methods for Simulation of Protic Molecular Ion Pairs

In this work, we benchmark the accuracy of the density-functional tight-binding (DFTB) method, namely the long-range corrected second-order (LC-DFTB2) and third-order (DFTB3) models, for predicting energetics of imidazolium-based ionic liquid (IL) ion pairs. We compare the DFTB models against popular density functionals such as LC-ωPBE and B3LYP, using ab initio domain-based local pair-natural orbital coupled cluster (DLPNO-CC) energies as reference. Calculations were carried out in the gas phase, as well as in aqueous solution using implicit solvent methods. We find that the LC-DFTB2 model shows excellent performance in the gas phase and agrees well with reference energies in implicit solvent, often outperforming DFTB3 predictions for complexation energetics. Our study identifies a range of opportunities for use of the LC-DFTB method and quantifies its sensitivity to protonation states and the types of chemical interactions between ion pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proposal for the utilization of the total cross section covariances and its correlations with channel reactions for sensitivity and uncertainty analysis

An alternate method for the estimation of the global uncertainty on criticality, using the total cross section and its covariances, is proposed. Application of the method with currently available covariance data leads to an unrealistically large prediction of the global uncertainty on criticality. New covariances for total cross section and individual reactions are proposed. Analysis with the proposed covariance matrices is found to result in a global uncertainty for criticality consistent with the traditional method. Recommendations are made to evaluators for providing total cross section covariances. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Holmium-163 electron-capture spectroscopy with transition-edge sensors

Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (Q EC < 3 keV) and short half-life (4570 years) of 163 Ho make it attractive for high-precision electron-capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the escaping neutrino. We have developed a complete process for proton irradiation-based isotope production, isolation, and purification of 163 Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163 Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163 Ho. Finally, we present our work in these areas and discuss the measured spectrum and its comparison to current theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗