Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion acceleration in Ar-Xe and Ar-He plasmas. II. Ion velocity distribution functions

Ion velocity distribution functions (ivdfs) are investigated by laser induced fluorescence in Ar-Xe and Ar-He expanding helicon plasmas as a function of gas composition. In the case of Ar-Xe plasma, it was found that in the helicon source, both the Ar{sup +} and Xe{sup +} vdfs are unimodal. Their parallel speeds are subsonic and unaffected by changes in gas composition. At the end of the source, the argon ivdf shows a bimodal structure indicative of an electric double layer upstream of the measurement location. The fast argon ion component parallel velocity increases with Xe fraction from 6.7 to 8 km/s as the Xe fraction increases from 0% to 4%. In the expansion region, the bimodal character of Ar ivdf is maintained with a supersonic fast component reaching parallel speeds of 10.5 km/s. For all the studied plasma conditions and different spatial locations, the Xe{sup +} vdf exhibits a unimodal structure with a maximum parallel flow velocity of 2.2 km/s at the end of the source. For Ar-He plasma, the Ar ivdf is bimodal with the fast ion component parallel velocity increasing from 5.2 to 7.8 km/s as the He fraction increases from 0% to 30%. For the same He fraction range, the slow argon ion population distribution changes from a single Gaussian to a wide distribution extending all the way from the speed of the fast population to 0 m/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SINGLE-STAR H II REGIONS AS A PROBE OF MASSIVE STAR SPECTRAL ENERGY DISTRIBUTIONS

The shape of OB-star ionizing spectral energy distributions (SEDs) is a critical component in many diagnostics of galaxy and interstellar medium properties. To quantitatively examine the shape of the OB-star SED, we compare long slit observations of single-star, Large Magellanic Cloud H II regions to the predictions from CLOUDY photoionization simulations that use CoStar, TLUSTY, and WM-basic stellar atmosphere models as the ionizing source. For each atmosphere model, we run grids of H II region simulations with the effective temperature (T{sub eff}) of the star as a free parameter. The best SEDs from each atmosphere code are found by matching the predicted emission-line spectra with those observed from the nebulae. By assuming a clumpy gas distribution, all atmosphere codes are able to reproduce the observed emission lines, except at the highest energy transitions {approx}> 40 eV. Taking into account both low and high energy transitions, we find that simulations using WM-basic produce the best agreement with the observed line ratios. The rates of ionizing photons from different atmosphere models vary systematically with the relative hardness of the SEDs. However, in general the rates produced by the model SEDs, for standard log(g) = 4.0 models, are consistent with the rates derived from the H{alpha} luminosities. We find that our effective temperatures inferred from the nebular ionization balance are consistent with those predicted by conventional photospheric-based calibrations from the literature. We suggest that future spectral type to T{sub eff} calibrations can be constructed from nebular data.

79 ASTRONOMY AND ASTROPHYSICS↗

Equilibrium reconstruction based on core magnetic measurement and its applications on equilibrium transition in Joint-TEXT tokamak

Evaluation and reconstruction of plasma equilibrium, especially to resolve the safety factor profile, is imperative for advanced tokamak operation and physics study. Based on core magnetic measurement by the high resolution laser polarimeter-interferometer system (POLARIS), the equilibrium of Joint-TEXT (J-TEXT) plasma is reconstructed and profiles of safety factor, current density, and electron density are, therefore, obtained with high accuracy and temporal resolution. The equilibrium reconstruction procedure determines the equilibrium flux surfaces essentially from the data of POLARIS. Refraction of laser probe beam, a major error source of the reconstruction, has been considered and corrected, which leads to improvement of accuracy more than 10%. The error of reconstruction has been systematically assessed with consideration of realistic diagnostic performance and scrape-off layer region of plasma, and its accuracy has been verified. Fast equilibrium transitions both within a single sawtooth cycle and during the penetration of resonant magnetic perturbation have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and recent results of MAGIC

MAGIC is a single-dish Cherenkov telescope located on La Palma (Spain), hence with an optimal view on the Northern sky. Sensitive in the 30 GeV-30 TeV energy band, it is nowadays the only ground-based instrument being able to measure high-energy {gamma}-rays below 100 GeV. We review the most recent experimental results obtained using MAGIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuSTAR observations of magnetar 1E 1841–045

We report new spectral and temporal observations of the magnetar 1E 1841–045 in the Kes 73 supernova remnant obtained with the Nuclear Spectroscopic Telescope Array. Combined with new Swift and archival XMM-Newton and Chandra observations, the phase-averaged spectrum is well characterized by a blackbody plus double power law, in agreement with previous multimission X-ray results. However, we are unable to reproduce the spectral results reported based on Suzaku observations. The pulsed fraction of the source is found to increase with photon energy. The measured rms pulsed fractions are ∼12% and ∼17% at ∼20 and ∼50 keV, respectively. We detect a new feature in the 24-35 keV band pulse profile that is uniquely double peaked. This feature may be associated with a possible absorption or emission feature in the phase-resolved spectrum. We fit the X-ray data using the recently developed electron-positron outflow model by Beloborodov for the hard X-ray emission from magnetars. This produces a satisfactory fit, allowing a constraint on the angle between the rotation and magnetic axes of the neutron star of ∼20° and on the angle between the rotation axis and line of sight of ∼50°. In this model, the soft X-ray component is inconsistent with a single blackbody; adding a second blackbody or a power-law component fits the data. The two-blackbody interpretation suggests a hot spot of temperature kT ≈ 0.9 keV occupying ∼1% of the stellar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

areaDetector/ADTimePix3

ADTimePix3 is an open‑source EPICS areaDetector driver for TimePix3 pixel detectors from Advanced Scientific Instruments (ASI). It provides a complete control and data‑acquisition interface between EPICS and the Serval server, supporting both real detectors (single‑chip and 2×2 quad configurations) and the TimePix3 emulator. The driver configures measurements via an HTTP/JSON REST API and acquires data through high‑rate TCP streams for raw events, images, and histograms. It offers real‑time preview and accumulated images, Time‑of‑Flight histogram processing, pixel masking (including Binary Pixel Configuration files and hot‑pixel tools), extensive health and status monitoring, and integration with standard areaDetector plugins for file saving and downstream analysis. ADTimePix3 is designed for Linux 64‑bit systems (tested on Ubuntu and RHEL) and is distributed under an MIT license with additional institutional disclaimers, enabling reuse and extension in photon science beamlines and other TimePix3‑based experimental facilities.

Gofron, Kaz↗

Implosion dynamics and K-shell x-ray generation in large diameter stainless steel wire array Z pinches with various nesting configurations

Nested stainless steel wire array variations were investigated on the 20 MA Z machine [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)]. In order to reach experimentally observed electron temperatures near 3.8 keV and excite the K shell, these {approx}6.7 keV photon energy x-ray sources must be of large initial diameter (45-80 mm) which poses a concern for magnetic Rayleigh-Taylor instability growth. We discuss the implosion dynamics in these large diameter wire arrays, including an analysis of the ablation phase indicating that the prefill material is snowplowed at large radius. Nested array configurations with various mass and radius ratios are compared for instability mitigation and K-shell scaling. Degradation of the K-shell x-ray power and yield was observed for shots that did not have simultaneous implosion of the outer and inner wire arrays. Shots that were designed per this constraint exhibited K-shell yield scaling consistent with the model of J. W. Thornhill et al. [IEEE Trans. Plasma Sci. 34, 2377 (2006)] which had been benchmarked to single array results. This lends confidence to K-shell yield predictions using this model for future shots on the refurbished Z machine. Initial results employing a triple nested wire array to stabilize the large diameter implosion are also reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COLLISIONAL EXCITATION OF FAR-INFRARED LINE EMISSIONS FROM WARM INTERSTELLAR CARBON MONOXIDE (CO)

Motivated by recent observations with Herschel/PACS, and the availability of new rate coefficients for the collisional excitation of CO, the excitation of warm astrophysical CO is revisited with the use of numerical and analytic methods. For the case of an isothermal medium, results have been obtained for a wide range of gas temperatures (100-5000 K) and H{sub 2} densities (10{sup 3}-10{sup 9} cm{sup -3}), and presented in the form of rotational diagrams, in which the logarithm of the column density per magnetic substate, log (N{sub J} /g{sub J} ), is plotted for each state, as a function of its energy, E{sub J} . For rotational transitions in the wavelength range accessible to Herschel/PACS, such diagrams are nearly linear when n(H{sub 2}) {>=} 10{sup 8} cm{sup -3}. When n(H{sub 2}) {approx} 10{sup 6.8}-10{sup 8} cm{sup -3}, they exhibit significant negative curvature, whereas when n(H{sub 2}) {<=} 10{sup 4.8} cm{sup -3}, the curvature is uniformly positive throughout the PACS-accessible range. Thus, the observation of a positively curved CO rotational diagram does not necessarily require the presence of multiple temperature components. Indeed, for some sources observed with Herschel/PACS, the CO rotational diagrams show a modest positive curvature that can be explained by a single isothermal component. Typically, the required physical parameters are densities in the 10{sup 4}-10{sup 5} cm{sup -3} range and temperatures close to the maximum at which CO can survive. Other sources exhibit rotational diagrams with more curvature than can be accounted for by a single temperature component. For the case of a medium with a power-law distribution of gas temperatures, dN/dT{proportional_to}T{sup -b}, results have been obtained for H{sub 2} densities 10{sup 3}-10{sup 9} cm{sup -3} and power-law indices, b, in the range 1-5; such a medium can account for a CO rotational diagram that is more positively curved than any resulting from an isothermal medium.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray observations of two short but intense solar flares

This paper presents continuum X-ray spectra of impulsive emission in two short but intense solar flares which have relatively weak soft X-ray emissions, combining data obtained with soft X-ray and hard X-ray spectrometers on board two satellites, the SMM and Hinotori. In both flares, photon spectra of the impulsive component are found to flatten toward low energies, suggesting that a low-energy cutoff of the electron spectrum could be greater than about 50 keV and that the total energy contained in the electrons is significantly less than that usually quoted for a cutoff energy of about 20 keV. Different shapes of the X-ray spectrum at energies below 50 keV in other flares can be attributed to the variety in the relative strength of gradual and impulsive emissions. In one of the two flares, observations with the imager on Hinotori suggest that hard X-ray emission is likely to be associated with loop footpoints. It is argued that contamination by the gradual soft X-ray emission and/or the asymmetry of loops could explain the detection of single sources in the majority of flares that have been imaged in hard X-rays.

Nitta, Nariaki↗

Cloud Thickness from Diffusion of Lidar Pulses in Clouds

Measurements of the distribution of reflected light from a laser beam incident on an aqueous suspension of particles or "cloud" with known thickness and particle size distribution are reported. The distribution is referred to as the "cloud radiative Green's function", G. In the diffusion domain, G is sensitive to cloud thickness, allowing that important quantity to be retrieved. The goal of the laboratory simulation is to provide preliminary estimates of sensitivity of G to cloud thickness,for use in the optimal design of an offbeam Lidar instrument for remote sensing of cloud thickness (THOR, Thickness from Offbeam Returns). These clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The microsphere size distribution is roughly lognormal, from 0.5 microns to 25 microns, similar to real clouds. Density of suspended spheres is adjusted so mean-free-path of visible photons is about 10 cm, approximately 1000 times smaller than in real clouds. The light source is a ND:YAG laser at 530 nm. Detectors are flux and photon-counting Photomultiplier Tube (PMTS), with a glass probe for precise positioning. A Labview 5 VI controls positioning, and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider, and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns, and step size is selectable from the VI software. Far from the incident beam, the rate of exponential increase as the direction of the incident beam is approached scales as expected from diffusion theory, linearly with the cloud thickness, and inversely as the square root of the reduced optical thickness, and is independent of particle size. Near the beam the signal begins to increase faster than exponential, due to single and low-order scattering near the backward direction, and here the distribution depends on particle size. Results are being used to verify 3D Monte Carlo radiative transfer simulations, used to estimate signal-to-noise ratios for remotely sensed off beam returns, for both homogeneous and inhomogeneous clouds. Signal-to-noise estimates show that unfiltered observations are straight forward at night, while narrow band pass filters are being studied for day.

Cahalan, Robert F.↗

Imprinting a Focused X-Ray Laser Beam to Measure Its Full Spatial Characteristics

The new generation of x-ray free-electron lasers opens up unique avenues for exploring matter under exotic and extreme conditions. Extensive spatial characterization of focused, typically (sub)micron-sized, laser beams is indispensable but, nevertheless, difficult to be accomplished due to excessive radiation intensities. Methods exist allowing indirect or semidirect focus characterization from a safe distance far from the focal point. Here, in this study, we present a direct method of in-focus numerical phase recovery exploiting multishot desorption imprints in poly(methyl methacrylate). Shapes of the imprints serve as input data for the newly developed code PhaRe (phase recovery), inspired by the iterative Gerchberg-Saxton algorithm. A procedure of dynamic input-output mixing guarantees that the algorithm always converges to a self-consistent paraxial Helmholtz equation solution, which is thereafter optimized for transverse spatial coherence. Very good agreement with single-shot ablation imprints in lead tungstate (PbWO 4 ) is found. The experiment is carried out at the Linac Coherent Light Source with a focused beam monochromatized at 800 eV. The results of the coherence optimization indicate that the act of monochromatization may have an effect on otherwise very good transverse coherence of free-electron laser beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗

Room-temperature high-purity single-photon emission from carbon-doped boron nitride thin films

Hexagonal boron nitride (h-BN) has emerged as a promising platform for generating room temperature single photons exhibiting high brightness and spin-photon entanglement. However, improving emitter purity, stability, and scalability remains a challenge for quantum technologies. Here, we demonstrate highly pure and stable single-photon emitters (SPEs) in h-BN by directly growing carbon-doped, centimeter-scale h-BN thin films using the pulsed laser deposition (PLD) method. These SPEs exhibit room temperature operation with polarized emission, achieving a g (2) (0) value of 0.015, which is among the lowest reported for room temperature SPEs and the lowest achieved for h-BN SPEs. It also exhibits high brightness (~0.5 million counts per second), remarkable stability during continuous operation (>15 min), and a Debye-Waller factor of 45%. First-principles calculations reveal unique carbon defects responsible for these properties, enabled by PLD’s low-temperature synthesis and in situ doping. Our results demonstrate an effective method for large-scale production of high-purity, stable SPEs in h-BN, enabling robust quantum optical sources for various quantum applications.

36 MATERIALS SCIENCE↗

Use of Beacon Satellites for Efficient Uplink Transmission for Free-Space Quantum Entanglement Distribution

Efficient transmission of optical beams from ground to space is important for free-space entanglement distribution in a dual-uplink architecture in which photons from entanglement sources at two ground locations interact in an optical Bell-state measurement implemented on a satellite. Efficient transmission requires large transmitting apertures to minimize diffraction losses and high-performance adaptive optics to overcome the effects of atmospheric turbulence. Achieving good atmospheric compensation for beams transmitted to satellites is challenging because the need to point ahead of the satellite introduces anisoplanatism error that limits the effectiveness of the adaptive optics. An attractive approach for solving the point-ahead problem is to position a separate small satellite at the point-ahead location to provide a beacon source for the adaptive optics. This paper presents analysis of the requirements for the beacon source(s) for a dual-uplink entanglement-distribution demonstration. A relative performance metric is defined and evaluated for multiple beacon configurations, from a single, fixed beacon serving both ground sites to a dedicated beacon for each site continually adjusted to be at the correct point-ahead distance from the target satellite.

quantum↗

Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance

Often only a single physical process or component is investigated in the simulation of radiation detector systems. The results are then considered to be representative of what is expected in the correlating physical experiment. Although singular assessments may serve as a good estimate, the overall performance of a radiation detector system depends on several physical processes and the performance of all components within the system. Our Geant4-based multiphysics simulation toolkit couples radiation transport with optical photon processes, providing simulations of radiation detector systems components from the scintillator through the photocathode of the photodetector. Work to incorporate the back-end detector components, including the complete photodetector and subsequent electronics (e.g., amplifiers, digitizers), is underway. Geant4 is used to model the radiation transport and optical photon processes that occur in the front-end detector system components when exposed to a chosen source. These components include the scintillator, detector housing, optical coupling to the photodetector, and photocathode of the photodetector. Characteristics of several detector systems that have been studied include time response; pulse height spectra; number of photoelectrons per MeV; detector efficiency versus incident quanta energy; and effects on detector response due to change in geometries, materials, and reflectivity. Comparison of these characteristics by means of this toolkit enables the selection of the optimal individual components; thus, it is possible to specify the radiation detector system best suited to meet the requirements of any physical experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantized Electronic Doping towards Atomically Controlled “Charge-Engineered” Semiconductor Nanocrystals

“Charge engineering” of semiconductor nanocrystals (NCs) through so-called electronic impurity doping is a long-standing challenge in colloidal chemistry and holds promise for ground-breaking advancements in many optoelectronic, photonic, and spin-based nanotechnologies. To date, our knowledge is limited to a few paradigmatic studies on a small number of model compounds and doping conditions, with important electronic dopants still unexplored in nanoscale systems. Equally importantly, fine-tuning of charge engineered NCs is hampered by the statistical limitations of traditional approaches. The resulting intrinsic doping inhomogeneity restricts fundamental studies to statistically averaged behaviors and complicates the realization of advanced device concepts based on their advantageous functionalities. We aim to address these issues by realizing the first example of II–VI NCs electronically doped with an exact number of heterovalent gold atoms, a known p-type acceptor impurity in bulk chalcogenides. Single-dopant accuracy across entire NC ensembles is obtained through a novel non-injection synthesis employing ligand-exchanged gold clusters as “quantized” dopant sources to seed the nucleation of CdSe NCs in organic media. Structural, spectroscopic, and magneto-optical investigations trace a comprehensive picture of the physical processes resulting from the exact doping level of the NCs. Gold atoms, doped here for the first time into II–VI NCs, are found to incorporate as nonmagnetic Au + species activating intense size-tunable intragap photoluminescence and artificially offsetting the hole occupancy of valence band states. Fundamentally, the transient conversion of Au + to paramagnetic Au 2+ (5d 9 configuration) under optical excitation results in strong photoinduced magnetism and diluted magnetic semiconductor behavior revealing the contribution of individual paramagnetic impurities to the macroscopic magnetism of the NCs. Altogether, our results demonstrate a new chemical approach toward NCs with physical functionalities tailored to the single impurity level and offer a versatile platform for future investigations and device exploitation of individual and collective impurity processes in quantum confined structures.

36 MATERIALS SCIENCE↗

the Large Aperture GRB Observatory

The Large Aperture GRB Observatory (LAGO) aims at the detection of high energy photons from Gamma Ray Bursts (GRB) using the single particle technique (SPT) in ground based water Cherenkov detectors (WCD). To reach a reasonable sensitivity, high altitude mountain sites have been selected in Mexico (Sierra Negra, 4550 m a.s.l.), Bolivia (Chacaltaya, 5300 m a.s.l.) and Venezuela (Merida, 4765 m a.s.l.). We report on the project progresses and the first operation at high altitude, search for bursts in 6 months of preliminary data, as well as search for signal at ground level when satellites report a burst.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗