Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Quantifying Fluid-Wettable Effective Pore Space in the Utica and Bakken Oil Shale Formations

Combined (ultra-) small angle neutron scattering measurements [(U)SANS] and a contrast matching technique were employed to quantify the porosity and pore size distribution from 1 nm to 10 μm and to differentiate accessible (open) pores and inaccessible (closed) pores with respect to organophilic and hydrophilic fluids for two Utica and two Bakken shale samples. Overall, the results indicate that around 40–70% of the pores in the Utica oil shales (mixed carbonate mudstone) are accessible to oil, and 34–37% of the pore surfaces are water-wet. In contrast, the Bakken oil shales (mixed siliceous mudstone and carbonate/siliceous mudstone), which have high total organic carbon contents, have a higher proportion of isolated pore space that is not preferentially wet by oil or water, with less than 36% of the pores accessible to both fluids. In addition, for both formations, pores less than 3 nm in diameter are not oil accessible (organic matter related) but water accessible (clay tactoids related).

58 GEOSCIENCES↗

Structure-property relationship of nanocrystalline Pr{sub 2}Co{sub 14}B-based hard magnetic film

Nanocrystalline Pr{sub 2}Co{sub 14}B-based films are deposited on two types of substrates at 600 deg. C by radio frequency magnetron sputtering. All samples are composed of a hard magnetic phase Pr{sub 2}Co{sub 14}B and a small amount of a soft magnetic phase Co{sub 3}B. The film sputtered on the thermally oxidized silicon wafer has a more dispersed distribution of Co{sub 3}B and a smaller average grain size of Pr{sub 2}Co{sub 14}B than that deposited on alumina substrates; therefore, the former film shows a stronger intergrain exchange coupling action (IECA) than the latter film. In addition, the coercivity (8.6 kOe) and ratio (0.68) of remanence to saturation magnetization of the film sputtered on thermally oxidized silicon wafers are considerably higher than those (0.4 kOe and 0.56) of the film deposited on alumina substrates. In the case of the film sputtered on alumina substrates, the size of most magnetic domains is comparable to the average grain size of magnetic phases, implying the occurrence of a weak IECA. However, in the case of the film sputtered on thermally oxidized silicon wafers, the size of most magnetic domains is considerably larger than the mean grain size of magnetic phases, indicating the occurrence of a strong IECA. The effect of the IECA on the coercivity of specimens is determined by analyzing the temperature dependence of coercivity in the framework of a nucleation model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

COLD MOLECULAR GAS IN MERGER REMNANTS. I. FORMATION OF MOLECULAR GAS DISKS

We present the ≲1 kpc resolution {sup 12}CO imaging study of 37 optically selected local merger remnants using new and archival interferometric maps obtained with ALMA, CARMA, the Submillimeter Array, and the Plateau de Bure Interferometer. We supplement a sub-sample with single-dish measurements obtained at the Nobeyama Radio Observatory 45 m telescope for estimating the molecular gas mass (10{sup 7} {sup –} {sup 11} M {sub ☉}) and evaluating the missing flux of the interferometric measurements. Among the sources with robust CO detections, we find that 80% (24/30) of the sample show kinematical signatures of rotating molecular gas disks (including nuclear rings) in their velocity fields, and the sizes of these disks vary significantly from 1.1 kpc to 9.3 kpc. The size of the molecular gas disks in 54% of the sources is more compact than the K-band effective radius. These small gas disks may have formed from a past gas inflow that was triggered by a dynamical instability during a potential merging event. On the other hand, the rest (46%) of the sources have gas disks that are extended relative to the stellar component, possibly forming a late-type galaxy with a central stellar bulge. Our new compilation of observational data suggests that nuclear and extended molecular gas disks are common in the final stages of mergers. This finding is consistent with recent major-merger simulations of gas-rich progenitor disks. Finally, we suggest that some of the rotation-supported turbulent disks observed at high redshifts may result from galaxies that have experienced a recent major merger.

79 ASTRONOMY AND ASTROPHYSICS↗

A CLOUDINESS INDEX FOR TRANSITING EXOPLANETS BASED ON THE SODIUM AND POTASSIUM LINES: TENTATIVE EVIDENCE FOR HOTTER ATMOSPHERES BEING LESS CLOUDY AT VISIBLE WAVELENGTHS

We present a dimensionless index that quantifies the degree of cloudiness of the atmosphere of a transiting exoplanet. Our cloudiness index is based on measuring the transit radii associated with the line center and wing of the sodium or potassium line. In deriving this index, we revisited the algebraic formulae for inferring the isothermal pressure scale height from transit measurements. We demonstrate that the formulae of Lecavelier et al. and Benneke and Seager are identical: the former is inferring the temperature while assuming a value for the mean molecular mass and the latter is inferring the mean molecular mass while assuming a value for the temperature. More importantly, these formulae cannot be used to distinguish between cloudy and cloud-free atmospheres. We derive values of our cloudiness index for a small sample of seven hot Saturns/Jupiters taken from Sing et al. We show that WASP-17b, WASP-31b, and HAT-P-1b are nearly cloud-free at visible wavelengths. We find the tentative trend that more irradiated atmospheres tend to have fewer clouds consisting of sub-micron-sized particles. We also derive absolute sodium and/or potassium abundances ∼10{sup 2} cm{sup −3} for WASP-17b, WASP-31b, and HAT-P-1b (and upper limits for the other objects). Higher-resolution measurements of both the sodium and potassium lines, for a larger sample of exoplanetary atmospheres, are needed to confirm or refute this trend.

79 ASTRONOMY AND ASTROPHYSICS↗

Volatiles in interplanetary dust particles: A comparison with CI and CM chondrites

In an effort to classify and determine the origin of interplanetary dust particles (IDPs), 14 of these particles were studied using a laser microprobe/mass spectrometer. The mass spectra for these particles varied dramatically. Some particles released hydroxide or water which probably originated in hydroxide-bearing minerals or hydrates. Others produced spectra which included a number of hydrocarbons and resembled meteorite spectra. However, none of the individual IDPs gave spectra which could be matched identically with a particular meteorite type such as a CI or CM carbonaceous chondrite. We believe this was due to the fact that 10-20 micron size IDPs are too small to be representative of the parent body. To verify that the diversity was due primarily to the small particle sizes, small grains of approximately the same size range as the IDPs were obtained from two primitive meteorites, Murchison and Orgueil, and these small meteorite particles were treated exactly like the IDPs. Considerable diversity was observed among individual grains, but a composite spectrum of all the grains from one meteorite closely resembled the spectrum obtained from a much larger sample of that meteorite. A composite spectrum of the 14 IDPs also resembled the spectra of the CM and CI meteorites, pointing to a possible link between IDPs and carbonaceous chondrites. This also illustrates that despite the inherent diversity in particles as small as 10-20 micron, conclusions can be drawn about the possible origin and overall composition of such particles by looking not only at results from individual particles but also by including many particles in a study and basing conclusions on some kind of composite data.

Bustin, Roberta↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Zn, Ga and Gd Doping on Structural and Magnetic Properties of Nanonickel Ferrite Prepared by Two Different Methods

Zn/Ga/Gd-substituted NiFe{sub 2}O{sub 4} was formed by solid state reaction and citrate methods. The influence of substitutions on phase formation, the strain, crystallize size, cations distribution and magnetic properties have been examined by X-ray diffraction, Mössbauer effect spectrometer, Fourier-transform infrared, and vibrating sample magnetometer. Zn/Ga/Gd substituted NiFe{sub 2}O{sub 4} samples prepared by solid state method showed that as gadolinium introduced into the system, a second phase was formed with a small percentage while samples prepared by citrate method exhibited a single phase. The distributions of different cations between different sites were determined by both Mössbauer effect spectroscopy, modified Bertaut and Rietveld analysis. Mössbauer technique at room temperature showed that samples synthesized by the ceramic method have a magnetic order while samples prepared by citrate method have a superparamagnetic nature. The canting angle between magnetic ions was increased by increased the amount of Zn in samples prepared by both methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Copper oxy-sulfide and copper sulfate thin films as transparent p-type conductive electrodes

Highlights: • Cu{sub 2}O, CuS and CuSO{sub 4} films are prepared and compared as p-type transparent electrodes. • CuSO{sub 4} gives the highest visible transmittance and CuS the lowest sheet resistance. • Cu{sub 2}O sulfurization produces CuS with a rougher surface and higher resistance. • CuS oxidation gives a Cu{sub 2}S and Cu{sub 2}O mixture with the best electrode performance. - Abstract: Starting from evaporated Cu layers, oxidation and sulfurization processes were developed by reaction at 250 °C with O{sub 2} or elemental sulfur to obtain Cu{sub 2}O and CuS thin films, respectively, with p-type conductivity and visible transparency. With the aim of achieving mixed compounds that combine the best properties of oxides (transparency) and sulfides (metal-like conductivity), different methods were tested, including Cu{sub 2}O sulfurization, CuS oxidation and direct Cu sulfoxidation. The crystalline structure, morphology and optical and electrical characteristics of the various samples were studied comparatively. CuSO{sub 4} crystals with a mean size above 40 nm were obtained by sulfoxidation, showing higher transmittance and lower resistance than the Cu{sub 2}O film shaped by crystallites of ∼13 nm. Moreover, a superior electrode quality was achieved after CuS oxidation, which produces a mixture of small Cu{sub 2}O and larger Cu{sub 2}S nanocrystals with visible transmittance as high as the pure oxide and a hole density close to the sulfide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High figure of merit in nanostructured n-type KPb{sub m}SbTe{sub m+2} thermoelectric materials.

We demonstrate that the KPb{sub m}SbTe{sub 2+m} system (PLAT-m for tellurium, antimony, lead potassium, m = 19-21) of materials exhibits high thermoelectric performance. Samples with compositions K{sub 1-x}Pb{sub m+{delta}}Sb{sub 1+{gamma}}Te{sub m+2} were prepared using several combinations of x, {delta}, {gamma} and m and their thermoelectric properties were investigated in the temperature range of 300-800 K. All K{sub 1-x}Pb{sub m+{delta}}Sb{sub 1+{gamma}}Te{sub m+2} samples exhibited n-type conduction over the measured temperature range. Their lattice thermal conductivities were found to be significantly reduced when compared to PbTe and even AgPb{sub m}SbTe{sub m+2}. For example, for K{sub 0.95}Pb{sub 20}Sb{sub 1.2}Te{sub 22} a lattice thermal conductivity as low as 0.4 W/(m {center_dot} K) was estimated at 650 K (based on a Lorenz number of 1.25 x 10{sup -8} W {center_dot} {Omega}/K{sup 2}). High resolution transmission electron microscopy on several samples revealed a widely dispersed nanoscale particle with varying size and shape endotaxially embedded inside a PbTe-rich matrix which is believed to be responsible for the reduced lattice thermal conductivity of K{sub 1-x}Pb{sub m+{delta}}Sb{sub 1+{gamma}}Te{sub m+2} materials. Because of their small size, the nanoinclusions are coherent with the matrix and therefore do not markedly degrade the electrical conductivity of the materials. As a result, very high figures of merit are achieved at high temperature for several compositions. For K{sub 0.95}Pb{sub 20}Sb{sub 1.2}Te{sub 22}, a maximum figure of merit ZT {approx} 1.6 was obtained around 750 K. This value is similar to that of n-type LAST-18 and is two times larger than that of the-state-of-the-art n-type PbTe.

36 MATERIALS SCIENCE↗

Reinterpreting fundamental plane correlations with machine learning

ABSTRACT This work explores the relationships between galaxy sizes and related observable galaxy properties in a large volume cosmological hydrodynamical simulation. The objectives of this work are to develop a better understanding of both the correlations between galaxy properties and the influence of environment on galaxy physics in order to build an improved model for the galaxy sizes, building off of the fundamental plane. With an accurate intrinsic galaxy size predictor, the residuals in the observed galaxy sizes can potentially be used for multiple cosmological applications, including making measurements of galaxy velocities in spectroscopic samples, estimating the rate of cosmic expansion, and constraining the uncertainties in the photometric redshifts of galaxies. Using projection pursuit regression, the model accurately predicts intrinsic galaxy sizes and have residuals which have limited correlation with galaxy properties. The model decreases the spatial correlation of galaxy size residuals by a factor of ∼5 at small scales compared to the baseline correlation when the mean size is used as a predictor.

Astronomy & Astrophysics↗

Action-based dynamical modeling for the Milky Way disk

We present RoadMapping, a full-likelihood dynamical modeling machinery that aims to recover the Milky Way’s (MW) gravitational potential from large samples of stars in the Galactic disk. RoadMapping models the observed positions and velocities of stars with a parameterized, three-integral distribution function (DF) in a parameterized axisymmetric potential. We investigate through differential test cases with idealized mock data how the breakdown of model assumptions and data properties affect constraints on the potential and DF. Our key results are: (i) If the MW’s true potential is not included in the assumed model potential family, we can—in the axisymmetric case—still find a robust estimate for the potential, with only ≲10% difference in surface density within |z|⩽1.1 kpc inside the observed volume. (ii) Modest systematic differences between the true and model DF are inconsequential. E.g., when binning stars to define sub-populations with simple DFs, binning errors do not affect the modeling as long as the DF parameters of neighboring bins differ by <20%. In addition, RoadMapping ensures unbiased potential estimates for either (iii) small misjudgements of the spatial selection function (i.e., ≲15% at the survey volume’s edge), (iv) if distances are known to within 10%, or (v) if proper motion uncertainties are known within 10% or are smaller than δμ≲1 mas yr{sup −1}. Challenges are the rapidly increasing computational costs for large sample sizes. Overall, RoadMapping is well suited to making precise new measurements of the MW’s potential with data from the upcoming Gaia releases.

79 ASTRONOMY AND ASTROPHYSICS↗

Airborne particulate matter and spacecraft internal environments

Instrumentation, consisting of a Shuttle Particle Sampler (SPS) and a Shuttle Particle Monitor (SPM), has been developed to characterize the airborne particulate matter in the Space Shuttle cabin during orbital flight. The SPS size selectively collects particles in four size fractions (0-2.5, 2.5-10, 10-100, and greater than 100 microns) which are analyzed postflight for mass concentration and size distribution, elemental composition, and morphology. The SPM provides a continuous record of particle concentration through photometric light scattering. Measurements were performed onboard Columbia, OV-102, during the flight of STS-32 in January 1990. No significant changes were observed in the particle mass concentration, size distribution, or chemical composition in samples collected during flight-day 2 and flight-day 7. The total mass concentration was 56 microg/cu cm with approximately half of the particles larger than 100 microns. Elemental analysis showed that roughly 70 percent of the particles larger than 2.5 microns were carbonaceous with small amounts of other elements present. The SPM showed no temporal or spatial variation in particle mass concentration during the mission.

Liu, Benjamin Y. H.↗

Improving the chi-squared approximation for bivariate normal tolerance regions

Let X be a two-dimensional random variable distributed according to N2(mu,Sigma) and let bar-X and S be the respective sample mean and covariance matrix calculated from N observations of X. Given a containment probability beta and a level of confidence gamma, we seek a number c, depending only on N, beta, and gamma such that the ellipsoid R = (x: (x - bar-X)'S(exp -1) (x - bar-X) less than or = c) is a tolerance region of content beta and level gamma; i.e., R has probability gamma of containing at least 100 beta percent of the distribution of X. Various approximations for c exist in the literature, but one of the simplest to compute -- a multiple of the ratio of certain chi-squared percentage points -- is badly biased for small N. For the bivariate normal case, most of the bias can be removed by simple adjustment using a factor A which depends on beta and gamma. This paper provides values of A for various beta and gamma so that the simple approximation for c can be made viable for any reasonable sample size. The methodology provides an illustrative example of how a combination of Monte-Carlo simulation and simple regression modelling can be used to improve an existing approximation.

Feiveson, Alan H.↗

Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery

This work extends the lossless data compression technique described in Fast Lossless Compression of Multispectral- Image Data, (NPO-42517) NASA Tech Briefs, Vol. 30, No. 8 (August 2006), page 26. The original technique was extended to include a near-lossless compression option, allowing substantially smaller compressed file sizes when a small amount of distortion can be tolerated. Near-lossless compression is obtained by including a quantization step prior to encoding of prediction residuals. The original technique uses lossless predictive compression and is designed for use on multispectral imagery. A lossless predictive data compression algorithm compresses a digitized signal one sample at a time as follows: First, a sample value is predicted from previously encoded samples. The difference between the actual sample value and the prediction is called the prediction residual. The prediction residual is encoded into the compressed file. The decompressor can form the same predicted sample and can decode the prediction residual from the compressed file, and so can reconstruct the original sample. A lossless predictive compression algorithm can generally be converted to a near-lossless compression algorithm by quantizing the prediction residuals prior to encoding them. In this case, since the reconstructed sample values will not be identical to the original sample values, the encoder must determine the values that will be reconstructed and use these values for predicting later sample values. The technique described here uses this method, starting with the original technique, to allow near-lossless compression. The extension to allow near-lossless compression adds the ability to achieve much more compression when small amounts of distortion are tolerable, while retaining the low complexity and good overall compression effectiveness of the original algorithm.

Xie, Hua↗

Constraints on Exposure Ages of Lunar and Asteroidal Regolith Particles

Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Exposure to the solar wind results in implantation effects that are preserved in the rims of grains (typically the outermost 100 nm), while impact processes result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. These processes are collectively referred to as space weathering. A critical element in the study of these processes is to determine the rate at which these effects accumulate in the grains during their space exposure. For small particulate samples, one can use the density of solar flare particle tracks to infer the length of time the particle was at the regolith surface (i.e., its exposure age). We have developed a new technique that enables more accurate determination of solar flare particle track densities in mineral grains <50 micron in size that utilizes focused ion beam (FIB) sample preparation combined with transmission electron microscopy (TEM) imaging. We have applied this technique to lunar soil grains from the Apollo 16 site (soil 64501) and most recently to samples from asteroid 25143 Itokawa returned by the Hayabusa mission. Our preliminary results show that the Hayabusa grains have shorter exposure ages compared to typical lunar soil grains. We will use these techniques to re-examine the track density-exposure age calibration from lunar samples reported by Blanford et al. (1975).

Berger, Eve L.↗

Additive Construction using Basalt Regolith Fines

Planetary surfaces are often covered in regolith (crushed rock), whose geologic origin is largely basalt. The lunar surface is made of small-particulate regolith and areas of boulders located in the vicinity of craters. Regolith composition also varies with location, reflecting the local bedrock geology and the nature and efficiency of the micrometeorite-impact processes. In the lowland mare areas (suitable for habitation), the regolith is composed of small granules (20 - 100 microns average size) of mare basalt and volcanic glass. Impacting micrometeorites may cause local melting, and the formation of larger glassy particles, and this regolith may contain 10-80% glass. Studies of lunar regolith are traditionally conducted with lunar regolith simulant (reconstructed soil with compositions patterned after the lunar samples returned by Apollo). The NASA Kennedy Space Center (KSC) Granular Mechanics & Regolith Operations (GMRO) lab has identified a low fidelity but economical geo-technical simulant designated as Black Point-1 (BP-1). It was found at the site of the Arizona Desert Research and Technology Studies (RATS) analog field test site at the Black Point lava flow in adjacent basalt quarry spoil mounds. This paper summarizes activities at KSC regarding the utilization of BP-1 basalt regolith and comparative work with lunar basalt simulant JSC-1A as a building material for robotic additive construction of large structures. In an effort to reduce the import or in-situ fabrication of binder additives, we focused this work on in-situ processing of regolith for construction in a single-step process after its excavation. High-temperature melting of regolith involves techniques used in glassmaking and casting (with melts of lower density and higher viscosity than those of metals), producing basaltic glass with high durability and low abrasive wear. Most Lunar simulants melt at temperatures above 1100 C, although melt processing of terrestrial regolith at 1500 C is not uncommon. These temperatures are achievable by laser heating or by using solar concentrators. Similar to volcanic magma, the cooling rate determines the crystallite size - slower cooling develops larger crystals, and rapid quenching can result in fully amorphous glass.

Additive↗