Search NASA⌕ Search

SEARCH · Search NASA

Results for “software based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Fast Algorithm for Evaluating Critical Current of High-Temperature Superconducting Pancake Coil

Second-generation (2G) high-temperature superconducting (HTS) tapes are now capable of carrying very high transport current and promising for a wide range of applications. The critical current of HTS coils is important for applications, such as superconducting electric machines, superconducting magnetic energy storage, and superconducting magnets. Therefore, precisely and quickly calculating critical current of HTS coils is very important for designing HTS devices. This paper provides a fast algorithm for evaluating critical current of HTS pancake coil. The fast algorithm is realized through a stationary model, which is based on finite element method (FEM) software. The stationary model means that the model is solved by stationary study instead of time-dependent study. To validate this method, a pancake HTS coil was wound and its critical current was measured. Meanwhile, an axial symmetric stationary model was built according to the geometry of the measured HTS coil. By comparing measured and calculated results, the effectiveness of the stationary model was demonstrated. Moreover, the stationary model is compared with H formulation model. The calculated results by the two models are nearly the same. However, by using stationary calculation, the stationary model can remarkably speed up the computational process. Due to the advantage of calculating speed, the stationary model can be used to characterize and design large-scale HTS applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding I/O workload characteristics of a Peta-scale storage system

Understanding workload characteristics is critical for optimizing and improving the performance of current systems and software, and architecting new storage systems based on observed workload patterns. In this paper, we characterize the I/O workloads of scientific applications of one of the world's fastest high performance computing (HPC) storage cluster, Spider, at the Oak Ridge Leadership Computing Facility (OLCF). OLCF flagship petascale simulation platform, Titan, and other large HPC clusters, in total over 250 thousands compute cores, depend on Spider for their I/O needs. We characterize the system utilization, the demands of reads and writes, idle time, storage space utilization, and the distribution of read requests to write requests for the Peta-scale Storage Systems. From this study, we develop synthesized workloads, and we show that the read and write I/O bandwidth usage as well as the inter-arrival time of requests can be modeled as a Pareto distribution. We also study the I/O load imbalance problems using I/O performance data collected from the Spider storage system.

I/O↗

A comprehensive modeling method for proton exchange membrane electrolyzer development

Hydrogen attracts significant interests as an effective energy carrier that can be derived from renewable sources. Hydrogen production using a proton-exchange membrane (PEM) electrolyzer can efficiently convert renewable power via water splitting in wide scales—from large, centralized generation to on-site production. Mathematical models with multiple scales and fidelities facilitate the continuing improvements of PEM electrolyzer development to improve performance, cost, and reliability. The model scopes and methods are presented in this paper, which also introduces a comprehensive PEM electrolysis modeling tool based on computational fluid dynamics (CFD) software, ANSYS/Fluent. The modeling tool incorporates electrochemical model of a PEM electrolysis cell to simulate the performance of coupled thermal-fluid, species transport, and electrochemical processes in a product-scale cell or stack by leveraging the powerful meshing generation and CFD solver of ANSYS/Fluent. The thermal-fluid modeling includes liquid water/gas two-phase flow and simulates a PEM electrolysis cell by using Fluent user-defined functions as add-on modules accounting for PEM-specific species transport and electrochemical processes. The modeling outcomes expediate PEM electrolyzer scaling up from basic material development and laboratory testing.

08 HYDROGEN↗

Comprehensive Detection of Single Amino Acid Variants and Evaluation of Their Deleterious Potential in a PANC-1 Cell Line

Identifying single amino acid variants (SAAVs) in cancer is critical for precision oncology. Several advanced algorithms are now available to identify SAAVs but attempts to combine different algorithms and optimize them on large datasets to achieve a more comprehensive coverage of SAAVs have not been implemented. Herein we report an expanded detection of SAAVs in the PANC-1 cell line using three different strategies, which results in identification of 540 SAAVs in the mass spectrometry data, the most comprehensive coverage yet reported. Among the set of 540 SAAVs, 79 are evaluated as deleterious SAAVs based on analysis using novel AssVar software in which one of the driver mutations found in each protein of KRAS, TP53 and SLC37A4 is further validated using independent selected reaction monitoring (SRM) analysis. Our study represents the most comprehensive discovery of SAAVs to date and the first large-scale detection of deleterious SAAVs in the PANC-1 cell line. This work may serve as the basis for future research in pancreatic cancer and personal immunotherapy and treatment.

59 BASIC BIOLOGICAL SCIENCES↗

One‐at‐a‐Time Parameter Perturbation Ensemble of the Community Land Model, Version 5.1

Comprehensive land models are subject to significant parametric uncertainty, which can be hard to quantify due to the large number of parameters and high model computational costs. We constructed a large parameter perturbation ensemble (PPE) for the Community Land Model version 5.1 with biogeochemistry configuration (CLM5.1-BGC). We performed more than 2,000 simulations perturbing 211 parameters across six forcing scenarios. This provides an expansive data set, which can be used to identify the most influential parameters on a wide range of output variables globally, by biome, or by plant functional type. We found that parameter effects can exceed scenario effects and that a small number of parameters explains a large fraction of variance across our ensemble. The most important parameters can differ regionally and also based on the forcing scenario. The software infrastructure developed for this experiment has greatly reduced the human and computer time needed for CLM PPEs, which can facilitate routine investigation of parameter sensitivity and uncertainty, as well as automated calibration.

Kennedy, Daniel [NSF National Center for Atmospher↗

Estimation of Anthocyanin Content of Berries by NIR Method

Anthocyanin contents of fruits were estimated by VIS spectrophotometer and compared with spectra measured by NIR spectrophotometer (600-1100 nm step 10 nm). The aim was to find a relationship between NIR method and traditional spectrophotometric method. The testing protocol, using NIR, is easier, faster and non-destructive. NIR spectra were prepared in pairs, reflectance and transmittance. A modular spectrocomputer, realized on the basis of a monochromator and peripherals Bentham Instruments Ltd (GB) and a photometric camera created at Canning Research Institute, were used. An important feature of this camera is the possibility offered for a simultaneous measurement of both transmittance and reflectance with geometry patterns T0/180 and R0/45. The collected spectra were analyzed by CAMO Unscrambler 9.1 software, with PCA, PLS, PCR methods. Based on the analyzed spectra quality and quantity sensitive calibrations were prepared. The results showed that the NIR method allows measuring of the total anthocyanin content in fresh berry fruits or processed products without destroying them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

Physical optics simulations with PHASE for SwissFEL beamlines

PHASE is a software tool for physical optics simulation based on the stationary phase approximation method. The code is under continuous development since about 20 years and has been used for instance for fundamental studies and ray tracing of various beamlines at the Swiss Light Source. Along with the planning for SwissFEL a new hard X-ray free electron laser under construction, new features have been added to permit practical performance predictions including diffraction effects which emerge with the fully coherent source. We present the application of the package on the example of the ARAMIS 1 beamline at SwissFEL. The X-ray pulse calculated with GENESIS and given as an electrical field distribution has been propagated through the beamline to the sample position. We demonstrate the new features of PHASE like the treatment of measured figure errors, apertures and coatings of the mirrors and the application of Fourier optics propagators for free space propagation.

43 PARTICLE ACCELERATORS↗

REDUCING THE DIMENSIONALITY OF DATA: LOCALLY LINEAR EMBEDDING OF SLOAN GALAXY SPECTRA

We introduce locally linear embedding (LLE) to the astronomical community as a new classification technique, using Sloan Digital Sky Survey spectra as an example data set. LLE is a nonlinear dimensionality reduction technique that has been studied in the context of computer perception. We compare the performance of LLE to well-known spectral classification techniques, e.g., principal component analysis and line-ratio diagnostics. We find that LLE combines the strengths of both methods in a single, coherent technique, and leads to improved classification of emission-line spectra at a relatively small computational cost. We also present a data subsampling technique that preserves local information content, and proves effective for creating small, efficient training samples from large, high-dimensional data sets. Software used in this LLE-based classification is made available.

79 ASTRONOMY AND ASTROPHYSICS↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

An architecture for real time data acquisition and online signal processing for high throughput tandem mass spectrometry

Independent, greedy collection of data events using simple heuristics results in massive over-sampling of the prominent data features in large-scale studies over what should be achievable through “intelligent,” online acquisition of such data. As a result, data generated are more aptly described as a collection of a large number of small experiments rather than a true large-scale experiment. Nevertheless, achieving “intelligent,” online control requires tight interplay between state-of-the-art, data-intensive computing infrastructure developments and analytical algorithms. In this paper, we propose a Software Architecture for Mass spectrometry-based Proteomics coupled with Liquid chromatography Experiments (SAMPLE) to develop an “intelligent” online control and analysis system to significantly enhance the information content from each sensor (in this case, a mass spectrometer). Using online analysis of data events as they are collected and decision theory to optimize the collection of events during an experiment, we aim to maximize the information content generated during an experiment by the use of pre-existing knowledge to optimize the dynamic collection of events.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GridAPPS-D™ a distribution management platform to develop applications for rural electric utilities

Rural electric utilities, many of which operate with a co-op management approach, have unique operational challenges not shared with their municipal or IOU counterparts. Rural electric utilities typically have fewer customers per feeder mile, and are generally less able to afford the costs, or provide robust support for today’s Advanced Distribution Management System (ADMS) offerings. Additionally, co-ops typically do not need the full suite of ADMS offerings but would benefit from a subset of applications such as OMS, Unbalanced Power-Flow, Volt-VAR optimization and FLISR (Fault Location Isolation and Service Restoration). Their needs, even within these applications, are simpler and more standardized. Lastly, due to their size, their IT capabilities and resources are commonly limited; hence hardware and software needs to be standards-based and easy to maintain with only most expansions of current capabilities. GridAPPS-D™ is an open-source, application development environment that’s part of the Department of Energy’s Grid Modernization Efforts, being led by the Pacific Northwest National Laboratory. The GridAPPS-D project is developing a reference architecture and implementation with the goal of reducing the time and cost to integrate distribution applications for both planning and operations through the use of standardized interfaces and data models. In this paper, we present a view of the reference architecture for GridAPPS-D and highlight its applicability to the rural electric utilities’ needs, including descriptions of applications being developed using this platform, and how they can be applied to other rural electric utilities.

distribution management, GridAPPS-D, rural electri↗

Poster — Thur Eve — 51: An analysis of the effectiveness of automated pre-, post- and intra-treatment auditing of electronic health records

We describe development of automated, web-based, electronic health record (EHR) auditing software for use within our paperless radiation oncology clinic. By facilitating access to multiple databases within the clinic, each patient's EHR is audited prior to treatment, regularly during treatment, and post treatment. Anomalies such as missing documentation, non-compliant workflow and treatment parameters that differ significantly from the norm may be monitored, flagged and brought to the attention of clinicians. By determining historical trends using existing patient data and by comparing new patient data with the historical, we expect our software to provide a measurable improvement in the quality of radiotherapy at our centre.

60 APPLIED LIFE SCIENCES↗

Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-CAMPUS-J-03: Elasticity Functions Based On 4DCT Images to Predict Tumor and Normal Tissue Response to Radiation for Patients with Lung Cancers

Purpose: To investigate radiotherapy outcomes by incorporating 4DCT-based physiological and tumor elasticity functions for lung cancer patients. Methods: 4DCT images were acquired from 28 lung SBRT patients before radiation treatment. Deformable image registration (DIR) was performed from the end-inhale to the end-exhale using a B-Spline-based algorithm (Elastix, an open source software package). The resultant displacement vector fields (DVFs) were used to calculate a relative Jacobian function (RV) for each patient. The computed functions in the lung and tumor regions represent lung ventilation and tumor elasticity properties, respectively. The 28 patients were divided into two groups: 16 with two-year tumor local control (LC) and 12 with local failure (LF). The ventilation and elasticity related RV functions were calculated for each of these patients. Results: The LF patients have larger RV values than the LC patients. The mean RV value in the lung region was 1.15 (±0.67) for the LF patients, higher than 1.06 (±0.59) for the LC patients. In the tumor region, the elasticity-related RV values are 1.2 (±0.97) and 0.86 (±0.64) for the LF and LC patients, respectively. Among the 16 LC patients, 3 have the mean RV values greater than 1.0 in the tumors. These tumors were located near the diaphragm, where the displacements are relatively large.. RV functions calculated in the tumor were better correlated with treatment outcomes than those calculated in the lung. Conclusion: The ventilation and elasticity-related RV functions in the lung and tumor regions were calculated from 4DCT image and the resultant values showed differences between the LC and LF patients. Further investigation of the impact of the displacements on the computed RV is warranted. Results suggest that the RV images might be useful for evaluation of treatment outcome for lung cancer patients.

60 APPLIED LIFE SCIENCES↗

Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Fast and Accurate Intersections on a Sphere

We introduce a fast, high-precision algorithm for calculating intersections between great circle arcs and lines of constant latitude on the unit sphere. We first propose a simplified intersection point formula with improved speed and numerical robustness over the ones traditionally implemented in geoscience software. We then show how algorithms based on the concept of error-free transformations (EFT) can be applied to evaluate this formula within a relative error bound that is on the order of machine precision. Here, we demonstrate that, with a vectorized and parallelized implementation, this enhanced accuracy is achieved with no compute time overhead compared to a direct calculation in hardware floating point, making our algorithm suitable for performance-sensitive applications like regridding of high-resolution climate data. In contrast, evaluating our formula using high-precision data types like quadruple precision and arbitrary precision, or using the robust intersection computation routines from the Computational Geometry Algorithms Library, leads to significant computational overhead, especially since these alternatives inhibit vectorization. More generally, our work demonstrates how EFT techniques can be combined and extended to implement nontrivial geometric calculations with high accuracy and speed.

Environmental sciences↗