Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The SNS External Antenna H- Ion Source

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that we will meet our operational commitments as well as provide for future facility upgrades with high reliability, we have developed an RF-driven, H- ion source based on a ceramic aluminum nitride (AlN) plasma chamber [1]. This source is expected to be utilized by the SNS for neutron production starting in 2009. This report details the design of the production source which features an AlN plasma chamber, 2-layer external antenna, cooled-multicusp magnet array, Cs2CrO4 cesium system and a Molybdenum plasma ignition gun. Performance of the production source both on the SNS accelerator and SNS test stand is reported. The source has also been designed to accommodate an elemental Cs system with an external reservoir which has demonstrated unanalyzed beam currents up to ~100mA (60Hz, 1ms) on the SNS ion source test stand.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

STATISTICS OF GAMMA-RAY POINT SOURCES BELOW THE FERMI DETECTION LIMIT

An analytic relation between the statistics of photons in pixels and the number counts of multi-photon point sources is used to constrain the distribution of gamma-ray point sources below the Fermi detection limit at energies above 1 GeV and at latitudes below and above 30 deg. The derived source-count distribution is consistent with the distribution found by the Fermi Collaboration based on the first Fermi point-source catalog. In particular, we find that the contribution of resolved and unresolved active galactic nuclei (AGNs) to the total gamma-ray flux is below 20%-25%. In the best-fit model, the AGN-like point-source fraction is 17% {+-} 2%. Using the fact that the Galactic emission varies across the sky while the extragalactic diffuse emission is isotropic, we put a lower limit of 51% on Galactic diffuse emission and an upper limit of 32% on the contribution from extragalactic weak sources, such as star-forming galaxies. Possible systematic uncertainties are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF AN ENERGETIC 38.5 ms PULSAR POWERING THE GAMMA-RAY SOURCE IGR J18490-0000/HESS J1849-000

We report the discovery of a 38.5 ms X-ray pulsar in observations of the soft {gamma}-ray source IGR J18490-0000 with the Rossi X-ray Timing Explorer (RXTE). PSR J1849-0001 is spinning down rapidly with period derivative 1.42 x 10{sup -14} s s{sup -1}, yielding a spin-down luminosity E-dot = 9.8 x 10{sup 36} erg s{sup -1}, characteristic age {tau}{sub c}{identical_to}P/2 P-dot = 42.9 kyr, and surface dipole magnetic field strength B{sub s} = 7.5 x 10{sup 11} G. Within the INTEGRAL/IBIS error circle lies a point-like XMM-Newton and Chandra X-ray source that shows evidence of faint extended emission consistent with a pulsar wind nebula (PWN). The XMM-Newton spectrum of the point source is well fitted by an absorbed power-law model with photon index {Gamma}{sub PSR} = 1.1 {+-} 0.2, N{sub H} = (4.3 {+-} 0.6) x 10{sup 22} cm{sup -2}, and F{sub PSR}(2-10 keV) = (3.8 {+-} 0.3) x 10{sup -12} erg cm{sup -2} s{sup -1}, while the spectral parameters of the extended emission are roughly {Gamma}{sub PWN} {approx} 2.1 and F{sub PWN}(2-10 keV) {approx} 9 x 10{sup -13} erg cm{sup -2} s{sup -1}. IGR J18490-0000 is also coincident with the compact TeV source HESS J1849-000. For an assumed distance of 7 kpc in the Scutum arm tangent region, the 0.35-10 TeV luminosity of HESS J1849-000 is 0.13% of the pulsar's spin-down energy, while the ratio F(0.35-10 TeV)/F{sub PWN}(2-10 keV) {approx} 2. These properties are consistent with leptonic models of TeV emission from PWNe, with PSR J1849-0001 in a stage of transition from a synchrotron X-ray source to an inverse Compton {gamma}-ray source.

79 ASTRONOMY AND ASTROPHYSICS↗

Source-sink relationships

Life on earth depends on the growth and survival of plants. In order for plants to grow and develop effectively, coordination between sources and sinks is required. Source organs provide a net uptake of resources whilst sink organs have a net drawdown of resources. Molecular mechanisms regulate the relationship between sources and sinks. These molecular mechanisms include carbon- and nitrogen-containing metabolites, plant hormones, and genes. Sources and sinks for both carbon and nitrogen are key contributors to plant growth, and these regulate themselves and one another via feedback, feedforward, and crosstalk mechanisms. Our understanding of the relationships between sources and sinks is increased by experimental manipulations of the source-sink balance. To bring about increases in crop growth and yield, a holistic view of sources and sinks must be developed, including the molecular mechanisms underpinning the relationships between them. Mathematical modelling can be an effective tool for providing this unified perspective.

54 ENVIRONMENTAL SCIENCES↗

Using Pb Isotope to Quantify the Effect of Various Sources on Multi-Metal Polluted soil in Guiyu

Guiyu is known as one of the largest e-waste disposal and recycling sites in China, which suffers greatly from heavy metal pollution. By evaluating the concentrations and distribution of 21 metal elements with Principal Component Analyses (PCA), five principal components were identified, which accounted for 70.4% of the information of the initial data matrix, including one e-waste recycling source, two geological sources, one source of human activities and one ocean aerosol source. Among them, the source of human activities cannot be detailed only by PCA. By using Pb isotope, the unexplained source was judged as battery sludge. Combining 21 metallic and metalloid element datasets with Pb isotope concentrations is more accurate and effective to identify uncertain sources in soil.

54 ENVIRONMENTAL SCIENCES↗

Source partitioning of anthropogenic groundwater nitrogen in a mixed-use landscape, Tutuila, American Samoa

This study presents a modeling framework for quantifying human impacts and for partitioning the sources of contamination related to water quality in the mixed-use landscape of a small tropical volcanic island. On Tutuila, the main island of American Samoa, production wells in the most populated region (the Tafuna-Leone Plain) produce most of the island’s drinking water. However, much of this water has been deemed unsafe to drink since 2009. Tutuila has three predominant anthropogenic non-point-groundwater-pollution sources of concern: on-site disposal systems (OSDS), agricultural chemicals, and pig manure. These sources are broadly distributed throughout the landscape and are located near many drinking-water wells. Water quality analyses show a link between elevated levels of total dissolved groundwater nitrogen (TN) and areas with high non-point-source pollution density, suggesting that TN can be used as a tracer of groundwater contamination from these sources. The modeling framework used in this study integrates land-use information, hydrological data, and water quality analyses with nitrogen loading and transport models. The approach utilizes a numerical groundwater flow model, a nitrogen-loading model, and a multi-species contaminant transport model. Nitrogen from each source is modeled as an independent component in order to trace the impact from individual land-use activities. Model results are calibrated and validated with dissolved groundwater TN concentrations and inorganic δ{sup 15}N values, respectively. Results indicate that OSDS contribute significantly more TN to Tutuila’s aquifers than other sources, and thus should be prioritized in future water-quality management efforts.

54 ENVIRONMENTAL SCIENCES↗

Verification of dry storage cask loading using monoenergetic photon sources

Safeguarding the contents of spent nuclear fuel dry storage casks requires the verification of cask contents, especially if continuity of knowledge has been lost. The high attenuation of the cask’s thick shielding and stored fuel assemblies makes verification difficult using conventional photon radiography. Thomson-scattering quasi-monoenergetic photon sources offer narrow angular and energy spread for increased penetration. This paper demonstrates the advantages of such a source by examining effects of source properties on transmission through thick, highly attenuating objects. This information is then applied to calculations and simulations of transmission for a variety of photon sources and cask configurations. Here, the performance of the source is compared to traditional bremsstrahlung sources and other advanced methods, in the context of typical nuclear fuel dry storage casks. It is shown that the use of a Thomson scattering based quasi-monoenergetic photon source enables determination of fuel assembly occupancies faster and more accurately than other methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alteration trends and geochemical source region characteristics preserved in the fluviolacustrine sedimentary record of Gale crater, Mars

The Mars Science Laboratory’s Chemistry and Camera (ChemCam) instrument suite on-board the Curiosity rover has analysed ~1200 sedimentary targets during the mission up to sol 1482. These targets have included sedimentary rock, diagenetic features (e.g., fracture-associated alteration halos, mineral veins, nodules, and erosion resistant raised ridges), active aeolian fines, soils and float. We have isolated ChemCam geochemical trends relating to diagenetic features and alteration products from those of the sedimentary rock in order to identify the compositional characteristics of Gale crater’s sediment source regions. The effects of grain size variation on sedimentary unit geochemistry have been taken into account by grouping and analysing geological units according to grain size. With obvious diagenetic features removed from the database, and predominately isochemical aqueous alteration inferred for the Mt Sharp Group samples, we propose that source region composition is a stronger source of geochemical change between the Bradbury and Mt Sharp Groups than open-system alteration. Additionally, a lack of correlation between the Chemical Index of Alteration (CIA) values and SiO 2 , MgO or FeO T indicates that the slight increase in chemical weathering of the Mt Sharp Group sediments was insufficient to overprint sediment source compositional signatures. This has led to the identification of five unique igneous endmember compositions which we hypothesise to have contributed to Gale crater’s stratigraphic record. These endmembers are: (1) a subalkaline basalt, compositionally similar to the tholeiitic Adirondack Class basalts of Gusev crater, and dominant within the finer grained units up to the base of Mt Sharp; (2) a trachybasalt, mostly identified within conglomerate units from the Darwin waypoint to the base of Mt Sharp; (3) a potassium-rich volcanic source, determined from strong potassium enrichment and a high abundance of sanidine that is most dominant in the fluvial sandstones and conglomerates of the Kimberley formation; (4) a highly evolved, silica-rich igneous source that correlates with the presence of tridymite, and is recorded in the lacustrine mudstone of Mt Sharp’s Marias Pass locality; and, (5) a fractionated, relatively SiO 2 -rich subalkaline basalt, seen to have influenced the composition of mudstone deposited in the lower part of the Mt Sharp Group. Endmembers (1), (2), (3), and (4) have previously been identified at specific waypoints along the rover’s traverse, but we show that their influence extends throughout Gale’s stratigraphic record. The occurrence of detected endmembers is also strongly correlated with stratigraphic position, which suggests changing sediment source regions with time. We conclude that Gale sediment provenances were much more varied than suggested by the largely homogenous, globally-distributed Martian basalt inferred from orbit, showing that complex magmatic assemblages exist within the ancient highland crust surrounding Gale.

58 GEOSCIENCES↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

The Los Alamos Neutron Science Center Spallation Neutron Sources

The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ~100 keV. The characteristics of these sources, and ongoing industry program are described in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Mining Nontraditional Water Sources for a Distributed Hydrogen Economy

Securing decarbonized economies for energy and commodities will require abundant and widely available green H 2 . Ubiquitous wastewaters and nontraditional water sources could potentially feed water electrolyzers to produce this green hydrogen without competing with drinking water sources. Herein, we show that the energy and costs of treating nontraditional water sources such as municipal wastewater, industrial and resource extraction wastewater, and seawater are negligible with respect to those for water electrolysis. We also illustrate that the potential hydrogen energy that could be mined from these sources is vast. Based on these findings, we evaluate the implications of small-scale, distributed water electrolysis using disperse nontraditional water sources. Techno-economic analysis and life cycle analysis reveal that the significant contribution of H 2 transportation to costs and CO 2 emissions results in an optimal levelized cost of hydrogen at small- to moderate-scale water electrolyzer size. The implications of utilizing nontraditional water sources and decentralized or stranded renewable energy for distributed water electrolysis are highlighted for several hydrogen energy storage and chemical feedstock applications. Finally, we discuss challenges and opportunities for mining H 2 from nontraditional water sources to achieve resilient and sustainable economies for water and energy.

54 ENVIRONMENTAL SCIENCES↗

Helicon plasma generator-assisted surface conversion ion source for the production of H{sup -} ion beams at the Los Alamos Neutron Science Center

The converter-type negative ion source currently employed at the Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. In this kind of an ion source the extracted H{sup -} beam current is limited by the achievable plasma density which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which deposits on the H{sup -} converter surface and degrades its performance. Therefore, we have started an ion source development project focused on replacing these thermionic cathodes (filaments) of the converter source by a helicon plasma generator capable of producing high-density hydrogen plasmas with low electron energy. In our studies which have so far shown that the plasma density of the surface conversion source can be increased significantly by exciting a helicon wave in the plasma, and we expect to improve the performance of the surface converter H{sup -} ion source in terms of beam brightness and time between services. The design of this new source and preliminary results are presented, along with a discussion of physical processes relevant for H{sup -} ion beam production with this novel design. Ultimately, we perceive this approach as an interim step towards our long-term goal, combining a helicon plasma generator with an SNS-type main discharge chamber, which will allow us to individually optimize the plasma properties of the plasma cathode (helicon) and H{sup -} production (main discharge) in order to further improve the brightness of extracted H{sup -} ion beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 140 mA cw deuteron electron cyclotron resonance source for the IFMIF-EVEDA project

In the framework of the IFMIF-EVEDA phase (International Fusion Materials Irradiation Facility--Engineering Validation and Engineering Design Activities), the CEA-Saclay is in charged of the design and realization of the 140 mA cw deuteron source. The IFMIF EVEDA demonstrator will be installed in Japan in the next six years and will have to accelerate the deuteron beam up to 9 MeV. CEA will build the source and the low energy beam line (LEBT) and will test the cw high intensity deuteron production at Saclay. The SILHI source is an electron cyclotron resonance (ECR) source, operating at 2.45 GHz. In 2001, it produced more than 130 mA of deuteron beam in pulsed mode to minimize neutron production. Such a result pushes to develop a new ECR source based on the SILHI design and equipped with a specific extraction system. Several options of the accelerator column will be implemented in order to improve the reliability and the efficiency of the source. The IFMIF source and LEBT design will be reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL (invited)

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e {mu}A of O{sup 7+}, 505 e {mu}A of Xe{sup 20+}, 306 e {mu}A of Xe{sup 27+}, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

43 PARTICLE ACCELERATORS↗

A hybrid surface arc discharge ion source to produce ultra pure Ca{sup +2} beams for {sup 40}Ca({alpha},{gamma}){sup 44}Ti reaction studies at ISAC/TRIUMF

ISAC is an accelerator facility primarily dedicated to astrophysical studies. Off-line and online ion sources provide up to 65 keV of stable and radioactive beams to the ISAC accelerators. Initial acceleration is done via a constant velocity radio frequency quadrupole that requires 2 keV/u. Then the beam is further accelerated to 1.5 MeV/u at ISAC-I and 6.5 MeV/u at ISAC-II. To study radiative capture reactions relevant for astrophysics, the recoil mass spectrometer DRAGON was built in the experimental area. {sup 40}Ca({alpha},{gamma}){sup 44}Ti is identified as one of the key reactions in supernovae to produce {sup 44}Ti and is given highest priority. For this experiment, an ultrapure Ca{sup +2} beam was requested from the off-line ion source. Initial tests showed that, when using conventional ion sources, {sup 40}Ar and {sup 40}K are the impurities that are most difficult to eliminate. In order to overcome this problem, a new concept was needed and the hybrid surface arc discharge ion source was born. The hybrid surface ion source consists of a small surface ionizer and an arc discharge placed in a solenoid field. A very low ratio of {sup 40}Ar/{sup 40}Ca=8x10{sup -5} was achieved with this new source and the experiment was completed successfully. The source is described in detail and its performance is discussed in this article.

43 PARTICLE ACCELERATORS↗

Electron source of triode type with radial converging electron flow for irradiation of cylindrical targets

Design of an electron source of triode type is described, which produces a radial converging electron beam employed for modification of the outer surface of fuel element claddings. Experimental investigations of the source showed that beam current magnitude, efficiency of beam focusing to the target, stability of source operation, and beam pulse duration become worse when the target diameter drops below certain values. A method for the calculation of the source operation was developed. Calculations showed that the reason of worse source operation is the initial angular spread of electrons when the target diameter is small. Because of the angular spread a part of electrons passes by the target and oscillates between the target and cathode. The space charge of the oscillating electrons lowers the emission current magnitude and leads to the formation of a virtual cathode in the grid-target gap despite the fact that the emission beam current is less than the limiting one. Formation of a virtual cathode is a reason for the unstable source operation and restriction of the beam pulse duration. Recommendations for the improvement of the source design are suggested.

43 PARTICLE ACCELERATORS↗