Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical processing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Advances in Kriging-Based Autonomous X-Ray Scattering Experiments

Autonomous experimentation is an emerging paradigm for scientific discovery, wherein measurement instruments are augmented with decision-making algorithms, allowing them to autonomously explore parameter spaces of interest. We have recently demonstrated a generalized approach to autonomous experimental control, based on generating a surrogate model to interpolate experimental data, and a corresponding uncertainty model, which are computed using a Gaussian process regression known as ordinary Kriging (OK). We demonstrated the successful application of this method to exploring materials science problems using x-ray scattering measurements at a synchrotron beamline. Here, we report several improvements to this methodology that overcome limitations of traditional Kriging methods. The variogram underlying OK is global and thus insensitive to local data variation. We augment the Kriging variance with model-based measures, for instance providing local sensitivity by including the gradient of the surrogate model. As with most statistical regression methods, OK minimizes the number of measurements required to achieve a particular model quality. However, in practice this may not be the most stringent experimental constraint; e.g. the goal may instead be to minimize experiment duration or material usage. We define an adaptive cost function, allowing the autonomous method to balance information gain against measured experimental cost. We provide synthetic and experimental demonstrations, validating that this improved algorithm yields more efficient autonomous data collection.

36 MATERIALS SCIENCE↗

MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.

60 APPLIED LIFE SCIENCES↗

LENS: Learning Enabled Network Synthesis

RTRC and UMD have developed novel machine learning based methods under the ARPA-E DIFFERENTIATE program for rapid acceleration of hypothesis generation in complex architecture design spaces involving both discrete choices of component inclusion and interconnection and continuous parametric decisions. The project named Learning Enabled Network Synthesis (LENS) further demonstrated the developed methods on challenging electrical power converter design problems by identifying the most suitable circuit topologies and simultaneously selecting the most appropriate components to achieve optimized design of power converter with improved performances. We demonstrated that LENS could enable exploration of very large design space of circuit topologies and components by addressing the limitations of conventional design process in non-linear, high switching speed, multi-dimensional power converter design and optimization. The key innovation developed in LENS is the seamless integration of statistical learning and logical reasoning techniques and building on the individual strengths of these techniques for rapid hypothesis discovery. The main component of LENS comprises of: 1) Graph Reasoning Engine (GRE) to enforce composition rules that rapidly reject all discrete architectures that are composed incorrectly and generates an adaptive database of feasible designs which can be used by ML modules, 2) Graph Generative Learning module which is a deep neural network based generative model for graph architectures which can enable design space exploration beyond the dataset generated by the GRE, 3) Graph Reduced Order Model (ROM) for graph domains for accelerating computation of output metrics, and 4) Active learning and Rule Discovery module for sample efficient learning and extracting logical rules from the learned ML models which will be integrated in the GRE to enhance the filtering effectiveness. LENS approach can be applied to any design domains where designs can be represented as multi-attribute graphs. The LENS team integrated the various technical innovations listed above into an optimization pipeline and exercised the optimization pipeline on the converter design problem. The LENS project demonstrated that the developed AI/ML technologies can be used to generate novel converter circuits >45x faster than experts on chosen use-cases. This can enable faster design space exploration and identification of new designs which are not considered by experts due to the increasing design space complexity. This has significant potential impact on the public and energy needs of the country. It is currently estimated that 30% of all electrical powers generated passes through power converters. The future estimate is that 80% of all power generated would be passing through converters. LENS fills a critical gap in this space since by accelerating the design process the designers would be able to generate more efficient converters which can lead to significant energy savings for the country.

42 ENGINEERING↗

Cold Molecular Gas Along the Merger Sequence in Local Luminous Infrared Galaxies

We present an initial result from the {sup 12}CO (J = 1–0) survey of 79 galaxies in 62 local luminous and ultraluminous infrared galaxy (LIRG and ULIRG) systems obtained using the 45 m telescope at the Nobeyama Radio Observatory. This is a systematic {sup 12}CO (J = 1–0) survey of the Great Observatories All-sky LIRGs Survey (GOALS) sample. The molecular gas mass of the sample is in the range 2.2×10{sup 8}--7.0×10{sup 9} M{sub ⊙} within the central several kiloparsecs subtended by the 15{sup ′′} beam. A method to estimate the size of a CO gas distribution is introduced, which is combined with the total CO flux in the literature. This method is applied to part of our sample, and we find that the median CO radius is 1–4 kpc. From the early stage to the late stage of mergers, we find that the CO size decreases while the median value of the molecular gas mass in the central several-kiloparsec region is constant. Our results statistically support a scenario where molecular gas inflows toward the central region from the outer disk to replenish gas consumed by starburst, and that such a process is common in merging LIRGs.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-531: Performance Evaluation of Multithreaded Geant4 for Proton Therapy Dose Calculations in a High Performance Computing Facility

Purpose: To evaluate the efficiency of multithreaded Geant4 (Geant4-MT, version 10.0) for proton Monte Carlo dose calculations using a high performance computing facility. Methods: Geant4-MT was used to calculate 3D dose distributions in 1×1×1 mm3 voxels in a water phantom and patient's head with a 150 MeV proton beam covering approximately 5×5 cm2 in the water phantom. Three timestamps were measured on the fly to separately analyze the required time for initialization (which cannot be parallelized), processing time of individual threads, and completion time. Scalability of averaged processing time per thread was calculated as a function of thread number (1, 100, 150, and 200) for both 1M and 50 M histories. The total memory usage was recorded. Results: Simulations with 50 M histories were fastest with 100 threads, taking approximately 1.3 hours and 6 hours for the water phantom and the CT data, respectively with better than 1.0 % statistical uncertainty. The calculations show 1/N scalability in the event loops for both cases. The gains from parallel calculations started to decrease with 150 threads. The memory usage increases linearly with number of threads. No critical failures were observed during the simulations. Conclusion: Multithreading in Geant4-MT decreased simulation time in proton dose distribution calculations by a factor of 64 and 54 at a near optimal 100 threads for water phantom and patient's data respectively. Further simulations will be done to determine the efficiency at the optimal thread number. Considering the trend of computer architecture development, utilizing Geant4-MT for radiotherapy simulations is an excellent cost-effective alternative for a distributed batch queuing system. However, because the scalability depends highly on simulation details, i.e., the ratio of the processing time of one event versus waiting time to access for the shared event queue, a performance evaluation as described is recommended.

60 APPLIED LIFE SCIENCES↗

Blinking statistics and molecular counting in direct stochastic reconstruction microscopy (dSTORM)

Abstract Motivation Many recent advancements in single-molecule localization microscopy exploit the stochastic photoswitching of fluorophores to reveal complex cellular structures beyond the classical diffraction limit. However, this same stochasticity makes counting the number of molecules to high precision extremely challenging, preventing key insight into the cellular structures and processes under observation. Results Modelling the photoswitching behaviour of a fluorophore as an unobserved continuous time Markov process transitioning between a single fluorescent and multiple dark states, and fully mitigating for missed blinks and false positives, we present a method for computing the exact probability distribution for the number of observed localizations from a single photoswitching fluorophore. This is then extended to provide the probability distribution for the number of localizations in a direct stochastic optical reconstruction microscopy experiment involving an arbitrary number of molecules. We demonstrate that when training data are available to estimate photoswitching rates, the unknown number of molecules can be accurately recovered from the posterior mode of the number of molecules given the number of localizations. Finally, we demonstrate the method on experimental data by quantifying the number of adapter protein linker for activation of T cells on the cell surface of the T-cell immunological synapse. Availability and implementation Software and data available at https://github.com/lp1611/mol_count_dstorm. Supplementary information Supplementary data are available at Bioinformatics online.

Patel, Lekha↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

Safety-Factor Calibration for Wind Turbine Extreme Loads

Proper prediction of long-term extreme values for operating wind turbine loads and deflections is a critical component of wind turbine design. Direct observations or simulations of long-term extremes are not yet available; therefore, these predictions rely on some combination of large numbers of simulations and extrapolation. Extrapolation methods themselves can have significant uncertainty, and they also require that the wind turbine designer have a greater level of statistical expertise--factors that make the methods less attractive for industrial application. As an alternative to extrapolation, safety factors can be calibrated using techniques that allow designers to use smaller data sets. To calculate such factors, a series of simulations was used to extrapolate 50 year extreme values for a 5 MW wind turbine. Two methods are proposed for calculating such safety factors: one based on the mean and standard deviation of extreme values, and one based on the median of extreme values. Through a process of random sampling without replacement, the safety factor based on the median of extreme values was found to be less variable and also more independent of the number of simulations. The safety factors required were as large as 1.7, or were only 1.25 if rotor thrust loads were considered the dominant design drivers.

17 WIND ENERGY↗

Time reversal symmetry of generalized quantum measurements with past and future boundary conditions

Here we expand the time reversal symmetry arguments of quantum mechanics, originally proposed by Wigner in the context of unitary dynamics, to contain situations including generalized measurements for monitored quantum systems. We propose a scheme to derive the time-reversed measurement operators by considering the Schrödinger picture dynamics of a qubit coupled to a measuring device, and show that the time-reversed measurement operators form a Positive Operator Valued Measure (POVM) set. We present three particular examples to illustrate time reversal of measurement operators: (1) the Gaussian spin measurement, (2) a dichotomous POVM for spin, and (3) the measurement of qubit fluorescence. We then propose a general rule to unravel any rank two qubit measurement, and show that the backward dynamics obeys the retrodicted equations of the forward dynamics starting from the time reversed final state. We demonstrate the time reversal invariance of dynamical equations using the example of qubit fluorescence. We also generalize the discussion of a statistical arrow of time for continuous quantum measurements introduced by Dressel et al. (Phys Rev Lett 119:220507, 2017): we show that the backward probabilities can be computed from a process similar to retrodiction from the time-reversed final state, and extend the definition of an arrow of time to ensembles prepared with pre- and post-selections, where we obtain a non-vanishing arrow of time in general. We discuss sufficient conditions for when time’s arrow vanishes and show our method also captures the contributions to time’s arrow due to natural physical processes like relaxation of an atom to its ground state. As a special case, we recover the time reversibility of the weak value as its complex conjugate using our method, and discuss how our conclusions differ from the time-symmetry argument of Aharonov–Bergmann–Lebowitz rule.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure retrieval from four-dimensional scanning transmission electron microscopy: Statistical analysis of potential pitfalls in high-dimensional data

Four-dimensional (4D) scanning transmission electron microscopy is one of the most rapidly growing modes of electron microscopy imaging. The advent of fast pixelated cameras and the associated data infrastructure have greatly accelerated this process. Yet conversion of the 4D datasets into physically meaningful structure images in real space remains an open issue. In this work, we demonstrate that it is possible to systematically create filters that will affect the apparent resolution or even qualitative features of the real-space structure image, reconstructing artificially generated patterns. As initial efforts, we explore statistical model selection algorithms, aiming for robustness and reliability of estimated filters. This statistical model selection analysis demonstrates the need for regularization and cross validation of inversion methods to robustly recover structure from high-dimensional diffraction datasets.

36 MATERIALS SCIENCE↗

Astrophysical S -factors, Thermonuclear Rates, and Electron Screening Potential for the 3 He(d,p) 4 He Big Bang Reaction via a Hierarchical Bayesian Model

Here, we developed a hierarchical Bayesian framework to estimate S-factors and thermonuclear rates for the 3 He(d,p) 4 He reaction, which impacts the primordial abundances of 3 He and 7 Li. The available data are evaluated and all direct measurements are taken into account in our analysis for which we can estimate separate uncertainties for systematic and statistical effects. For the nuclear reaction model, we adopt a single-level, two-channel approximation of R-matrix theory, suitably modified to take the effects of electron screening at lower energies into account. In addition to the usual resonance parameters (resonance location and reduced widths for the incoming and outgoing reaction channel), we include the channel radii and boundary condition parameters in the fitting process. Our new analysis of the 3 He(d,p) 4 He S-factor data results in improved estimates for the thermonuclear rates. This work represents the first nuclear rate evaluation using R-matrix theory embedded into a hierarchical Bayesian framework, properly accounting for all known sources of uncertainty. Therefore, it provides a test bed for future studies of more complex reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a still preclinical tumor therapy approach that uses arrays of a few tens of micrometer wide parallel beams separated by a few 100 μm. The production, measurement, and planning of such radiation fields are a challenge up to now. Here, the authors investigate the feasibility of radiochromic film dosimetry in combination with a microscopic readout as a tool to validate peak and valley doses in MRT, which is an important requirement for a future clinical application of the therapy. Methods: Gafchromic{sup ®} HD-810 and HD-V2 films are exposed to MRT fields at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF) and are afterward scanned with a microscope. The measured dose is compared with Monte Carlo calculations. Image analysis tools and film handling protocols are developed that allow accurate and reproducible dosimetry. The performance of HD-810 and HD-V2 films is compared and a detailed analysis of the resolution, noise, and energy dependence is carried out. Measurement uncertainties are identified and analyzed. Results: The dose was measured with a resolution of 5 × 1000 μm{sup 2} and an accuracy of 5% in the peak and between 10% and 15% in the valley region. As main causes for dosimetry uncertainties, statistical noise, film inhomogeneities, and calibration errors were identified. Calibration errors strongly increase at low doses and exceeded 3% for doses below 50 and 70 Gy for HD-V2 and HD-810 films, respectively. While the grain size of both film types is approximately 2 μm, the statistical noise in HD-V2 is much higher than in HD-810 films. However, HD-810 films show a higher energy dependence at low photon energies. Conclusions: Both film types are appropriate for dosimetry in MRT and the microscope is superior to the microdensitometer used before at the ESRF with respect to resolution and reproducibility. However, a very careful analysis of the image data is required. Dosimetry at low photon energies should be performed with great caution due to the energy sensitivity of the films. In this respect, HD-V2 films showed to have an advantage over HD-810 films. However, HD-810 films have a lower statistical noise level. When a higher resolution is required, e.g., for the dosimetry of pencil beam irradiations, noise may render HD-V2 films inapplicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTING UNSPECIFIED STRUCTURE IN LOW-COUNT IMAGES

Unexpected structure in images of astronomical sources often presents itself upon visual inspection of the image, but such apparent structure may either correspond to true features in the source or be due to noise in the data. This paper presents a method for testing whether inferred structure in an image with Poisson noise represents a significant departure from a baseline (null) model of the image. To infer image structure, we conduct a Bayesian analysis of a full model that uses a multiscale component to allow flexible departures from the posited null model. As a test statistic, we use a tail probability of the posterior distribution under the full model. This choice of test statistic allows us to estimate a computationally efficient upper bound on a p-value that enables us to draw strong conclusions even when there are limited computational resources that can be devoted to simulations under the null model. We demonstrate the statistical performance of our method on simulated images. Applying our method to an X-ray image of the quasar 0730+257, we find significant evidence against the null model of a single point source and uniform background, lending support to the claim of an X-ray jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Solid waste management challenges for cities in developing countries

Highlights: Black-Right-Pointing-Pointer Stakeholders. Black-Right-Pointing-Pointer Factors affecting performance waste management systems. Black-Right-Pointing-Pointer Questionnaire as Annex for waste management baseline assessment. - Abstract: Solid waste management is a challenge for the cities' authorities in developing countries mainly due to the increasing generation of waste, the burden posed on the municipal budget as a result of the high costs associated to its management, the lack of understanding over a diversity of factors that affect the different stages of waste management and linkages necessary to enable the entire handling system functioning. An analysis of literature on the work done and reported mainly in publications from 2005 to 2011, related to waste management in developing countries, showed that few articles give quantitative information. The analysis was conducted in two of the major scientific journals, Waste Management Journal and Waste Management and Research. The objective of this research was to determine the stakeholders' action/behavior that have a role in the waste management process and to analyze influential factors on the system, in more than thirty urban areas in 22 developing countries in 4 continents. A combination of methods was used in this study in order to assess the stakeholders and the factors influencing the performance of waste management in the cities. Data was collected from scientific literature, existing data bases, observations made during visits to urban areas, structured interviews with relevant professionals, exercises provided to participants in workshops and a questionnaire applied to stakeholders. Descriptive and inferential statistic methods were used to draw conclusions. The outcomes of the research are a comprehensive list of stakeholders that are relevant in the waste management systems and a set of factors that reveal the most important causes for the systems' failure. The information provided is very useful when planning, changing or implementing waste management systems in cities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental constraints on the Zn 73 ( n , γ ) Zn 74 reaction rate

Background: The recent observation of a neutron-star merger finally confirmed one astrophysical location of the rapid neutron-capture process (r-process). Evidence of the production of A < 140 nuclei was seen, but there is still little detailed information about how those lighter elements are produced in such an environment. Many of the questions surrounding the A ≈ 80 nuclei are likely to be answered only when the nuclear physics involved in the production of r-process nuclei is well understood. Neutron-capture reactions are an important component of the r-process, and neutron-capture cross sections of r-process nuclei, which are very neutron rich, have large uncertainties. Purpose: Indirectly determine the neutron-capture cross section and reaction rate of 73 Zn(n,γ ) 74 Zn. Methods: The nuclear level density (NLD) and γ-ray strength function (γSF) of 74 Zn were determined following a total absorption spectroscopy (TAS) experiment focused on the β decay of 74 Cu into 74 Zn performed at the National Superconducting Cyclotron Laboratory. The NLD and γSF were used as inputs in a Hauser-Feshbach statistical model to calculate the neutron-capture cross section and reaction rate. Results: The NLD and γSF of 74 Zn were experimentally constrained for the first time using β-delayed γ rays measured with TAS and the β-Oslo method. The NLD and γSF were then used to constrain the neutron-capture cross section and reaction rate for the 73 Zn(n, γ ) 74 Zn reaction. In Conclusion, the uncertainty in the neutron-capture cross section and reaction rate of 73 Zn(n, γ ) 74 Zn calculated in TALYS was reduced to under a factor of 2 from a factor of 5 in the cross section and a factor of 11 in the reaction rate using the experimentally obtained NLD and γSF.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A two-stage method for microcalcification cluster segmentation in mammography by deformable models

Purpose: Segmentation of microcalcification (MC) clusters in x-ray mammography is a difficult task for radiologists. Accurate segmentation is prerequisite for quantitative image analysis of MC clusters and subsequent feature extraction and classification in computer-aided diagnosis schemes. Methods: In this study, a two-stage semiautomated segmentation method of MC clusters is investigated. The first stage is targeted to accurate and time efficient segmentation of the majority of the particles of a MC cluster, by means of a level set method. The second stage is targeted to shape refinement of selected individual MCs, by means of an active contour model. Both methods are applied in the framework of a rich scale-space representation, provided by the wavelet transform at integer scales. Segmentation reliability of the proposed method in terms of inter and intraobserver agreements was evaluated in a case sample of 80 MC clusters originating from the digital database for screening mammography, corresponding to 4 morphology types (punctate: 22, fine linear branching: 16, pleomorphic: 18, and amorphous: 24) of MC clusters, assessing radiologists’ segmentations quantitatively by two distance metrics (Hausdorff distance—HDIST{sub cluster}, average of minimum distance—AMINDIST{sub cluster}) and the area overlap measure (AOM{sub cluster}). The effect of the proposed segmentation method on MC cluster characterization accuracy was evaluated in a case sample of 162 pleomorphic MC clusters (72 malignant and 90 benign). Ten MC cluster features, targeted to capture morphologic properties of individual MCs in a cluster (area, major length, perimeter, compactness, and spread), were extracted and a correlation-based feature selection method yielded a feature subset to feed in a support vector machine classifier. Classification performance of the MC cluster features was estimated by means of the area under receiver operating characteristic curve (Az ± Standard Error) utilizing tenfold cross-validation methodology. A previously developed B-spline active rays segmentation method was also considered for comparison purposes. Results: Interobserver and intraobserver segmentation agreements (median and [25%, 75%] quartile range) were substantial with respect to the distance metrics HDIST{sub cluster} (2.3 [1.8, 2.9] and 2.5 [2.1, 3.2] pixels) and AMINDIST{sub cluster} (0.8 [0.6, 1.0] and 1.0 [0.8, 1.2] pixels), while moderate with respect to AOM{sub cluster} (0.64 [0.55, 0.71] and 0.59 [0.52, 0.66]). The proposed segmentation method outperformed (0.80 ± 0.04) statistically significantly (Mann-Whitney U-test, p < 0.05) the B-spline active rays segmentation method (0.69 ± 0.04), suggesting the significance of the proposed semiautomated method. Conclusions: Results indicate a reliable semiautomated segmentation method for MC clusters offered by deformable models, which could be utilized in MC cluster quantitative image analysis.

60 APPLIED LIFE SCIENCES↗