Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Ptychographic x-ray imaging of surfaces on crystal truncation rod

Ptychography is a high-resolution imaging technique, which does not require lenses for image magnification and which provides phase contrast with high sensitivity. Here, we propose to use x-ray ptychography for the imaging of surface structure in crystalline samples. We show that ptychography can be used to image atomic step structures using coherent diffraction patterns recorded along the crystal truncation rod of a crystal surface. In a proof-of-concept experiment on a Pt (111) sample, we present ptychographic reconstructions showing features consistent with surface steps. Due to the penetration power of x-rays, this method could find interesting applications for the study of surface structures under buried interfaces or in harsh environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional atomic scale electron density reconstruction of octahedral tilt epitaxy in functional perovskites

Octahedral tilts are the most ubiquitous distortions in perovskite-related structures that can dramatically influence ferroelectric, magnetic, and electronic properties; yet the paradigm of tilt epitaxy in thin films is barely explored. Non-destructively characterizing such epitaxy in three-dimensions for low symmetry complex tilt systems composed of light anions is a formidable challenge. Here we demonstrate that the interfacial tilt epitaxy can transform ultrathin calcium titanate, a non-polar earth-abundant mineral, into high-temperature polar oxides that last above 900 K. The comprehensive picture of octahedral tilts and polar distortions is revealed by reconstructing the three-dimensional electron density maps across film-substrate interfaces with atomic resolution using coherent Bragg rod analysis. The results are complemented with aberration-corrected transmission electron microscopy,film superstructure reflections, and are in excellent agreement with density functional theory. Conclusively, the study could serve as a broader template for non-destructive, three-dimensional atomic resolution probing of complex low symmetry functional interfaces.

36 MATERIALS SCIENCE↗

Image reconstruction from sparse data ion synchrotron-radiation-based micro-tomography.

Synchrotron-radiation-based microcomputed-tomography (SR-{micro}CT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-{micro}CT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, synchrotron x-ray radiation from a large number of projection views can result in significant structural deformation within the specimen. A possible approach to reducing imaging time and specimen deformation is to decrease the number of projection views. In the work, using reconstruction algorithms developed recently for medical computed tomography (CT), we investigate and demonstrate image reconstruction from sparse-view data acquired in SR-{micro}CT. Numerical results of our study suggest that images of practical value can be obtained from data acquired at a number of projection views significantly lower than those used currently in a typical SR-{micro}CT imaging experiment.

99 GENERAL AND MISCELLANEOUS↗

The eukaryotic CMG helicase pumpjack and integration into the replisome

The eukaryotic replisome is a multiprotein machine that contains DNA polymerases, sliding clamps, helicase, and primase along with several factors that participate in cell cycle and checkpoint control. The detailed structure of the 11-subunit CMG helicase (Cdc45/Mcm2-7/GINS) has been solved recently by cryoEM single-particle 3D reconstruction and reveals pumpjack motions that imply an unexpected mechanism of DNA translocation. CMG is also the organizing center of the replisome. Recent in vitro reconstitution of leading and lagging strand DNA synthesis has enabled structural analysis of the replisome. By building the replisome in stages from pure proteins, single-particle EM studies have identified the overall architecture of the eukaryotic replisome. Suprisingly leading and lagging strand polymerases bind to opposite faces of the CMG helicase, unlike the long-held view that DNA polymerases are located in back of the helicase to act on the unwound strands.

DNA helicase↗

Al rich (111) and (110) surfaces of LaAlO 3

Lanthanum aluminate (LaAlO 3 ) has garnered significant interests since the discovery of a 2D electron gas at the LaAlO 3 /SrTiO 3 interface. Here in this work, the (110) surface of LaAlO 3 was studied using a combination of transmission electron microscopy plan and profile imaging, image simulation, electron diffraction, X-ray photoelectron spectroscopy, and density functional theory calculations. Profile imaging of the (110) surface was performed on a (111) oriented single crystalline sample with an Al rich surface. Our results indicate that high annealing temperatures (1000–1300°C) commonly used in preparing well ordered, flat surfaces of LaAlO 3 result in Al rich surfaces. The (110) surface was found to be single layered AlO x with a (2 × 1) reconstruction. Angle resolved X-ray photoelectron spectroscopy indicated that the (2 × 1) surface structure was not hydrated. Convex hull construction of surface enthalpies as a function of excess AlO 1.5 on the (110) surface was done using density functional theory calculations.

36 MATERIALS SCIENCE↗

Model independent x-ray standing wave analysis of periodic multilayer structures

We present a model independent approach for the analysis of X-ray fluorescence yield modulated by an X-ray standing wave (XSW), that allow a fast reconstruction of the atomic distribution function inside a sample without fitting procedure. The approach is based on the direct regularized solution of the system of linear equations that characterizes the fluorescence yield. The suggested technique was optimized for, but not limited to, the analysis of periodic layered structures where the XSW is formed under Bragg conditions. The developed approach was applied to the reconstruction of the atomic distribution function for LaN/BN multilayers with 50 periods of 43 Å thick layers. The object is especially difficult to analyze with traditional methods, as the estimated thickness of the interface region between the constituent materials is comparable to the individual layer thicknesses. However, using the suggested technique, it was possible to reconstruct width of the La atomic distribution showing that the La atoms stay localized within the LaN layers and interfaces and do not diffuse into the BN layer. The analysis of the reconstructed profiles showed that the positions of the center of the atomic distribution function can be estimated with an accuracy of 1 Å.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bottom-up structural proteomics: cryoEM of protein complexes enriched from the cellular milieu

X-ray crystallography often requires non-native constructs involving mutations or truncations, and is challenged by membrane proteins and large multicomponent complexes. Here, we present a bottom-up endogenous structural proteomics approach whereby near-atomic-resolution cryo electron microscopy (cryoEM) maps are reconstructed ab initio from unidentified protein complexes enriched directly from the endogenous cellular milieu, followed by identification and atomic modeling of the proteins. The proteins in each complex are identified using cryoID, a program we developed to identify proteins in ab initio cryoEM maps. As a proof of principle, we applied this approach to the malaria-causing parasite Plasmodium falciparum, an organism that has resisted conventional structural-biology approaches, to obtain atomic models of multiple protein complexes implicated in intraerythrocytic survival of the parasite. Our approach is broadly applicable for determining structures of undiscovered protein complexes enriched directly from endogenous sources.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic restructuring of supported metal nanoparticles and its implications for structure insensitive catalysis

Some fundamental concepts of catalysis are not fully explained but are of paramount importance for the development of improved catalysts. An example is the concept of structure insensitive reactions, where surface-normalized activity does not change with catalyst metal particle size. Here we explore this concept and its relation to surface reconstruction on a set of silica-supported Ni metal nanoparticles (mean particle sizes 1–6 nm) by spectroscopically discerning a structure sensitive (CO 2 hydrogenation) from a structure insensitive (ethene hydrogenation) reaction. Using state-of-the-art techniques, inter alia in-situ STEM, and quick-X-ray absorption spectroscopy with sub-second time resolution, we have observed particle-size-dependent effects like restructuring which increases with increasing particle size, and faster restructuring for larger particle sizes during ethene hydrogenation while for CO 2 no such restructuring effects were observed. Furthermore, a degree of restructuring is irreversible, and we also show that the rate of carbon diffusion on, and into nanoparticles increases with particle size. We finally show that these particle size-dependent effects induced by ethene hydrogenation, can make a structure sensitive reaction (CO 2 hydrogenation), structure insensitive. We thus postulate that structure insensitive reactions are actually apparently structure insensitive, which changes our fundamental understanding of the empirical observation of structure insensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Entropy-Tailored Fast-Charging Sodium Layered Cathodes

O3-type layered transition metal (TM) oxides are widely used as cathode materials for Na-ion batteries due to their high energy density potential, enabled by the state of charge (SoC)-dependent transition from octahedral (O-type) to prismatic (P-type) structures during Na-ion (de)sodiation. However, the O–P transition is often criticized for compromising the Na-ion mobility and limiting the cycle life. Herein, we reveal the intrinsic correlation between O–P transitions, oxygen behaviors, and Na-ion kinetics. We demonstrate that a compositionally versatile, entropy-tailored approach can promote preferred transitions (characterized by large lattice parameter deviations in the O-type region and rapid O–P biphasic reactions), enhancing Na-ion migration, as revealed by in situ high-energy synchrotron X-ray diffraction (HEXRD). Additionally, irreversible oxygen loss at high SoC is effectively mitigated, while TM migration and surface reconstruction are greatly suppressed, further accelerating Na-ion transport and stabilizing the structure, as confirmed by X-ray absorption spectroscopy (XAS) and theoretical analyses. The result is an exceptionally high rate capability of 88.7 mAh g –1 at 20 C (2.4 A g –1 ) with a superior normalized retention of 72.6%, accompanied by a prolonged lifetime with 74.3% retention after 1000 cycles. In conclusion, this work advances the understanding of the chemistry–property relationships in O3-type layered cathodes and broadens the prospects for fabricating high-power-density electrodes.

36 MATERIALS SCIENCE↗

Higher-order phase shift reconstruction approach

Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DECADE+ DES Y3 Weak Lensing Mass Map: A 13,000 deg $\^{} 2$ View of Cosmic Structure from 270 Million Galaxies

We present the largest galaxy weak lensing mass map of the late-time Universe, reconstructed from 270 million galaxies in the DECADE and DES Year 3 datasets, covering 13,000 square degrees. We validate the map through systematic tests against observational conditions (depth, seeing, etc.), finding the map is statistically consistent with no contamination. The large area covered by the mass map makes it a well-suited tool for cosmological analyses, cross-correlation studies and the identification of large-scale structure features. We demonstrate its potential by detecting cosmic filaments directly from the mass map for the first time and validating them through their association with galaxy clusters selected using the Sunyaev-Zeldovich effect from Planck and ACT DR6.

Gatti, M.↗

Quantifying Errors in 3D CME Parameters Derived from Synthetic Data Using White-Light Reconstruction Techniques

Current efforts in space weather forecasting of CMEs have been focused on predicting their arrival time and magnetic structure. To make these predictions, methods have been developed to derive the true CME speed, size, position, and mass, among others. Difficulties in determining the input parameters for CME forecasting models arise from the lack of direct measurements of the coronal magnetic fields and uncertainties in estimating the CME 3D geometric and kinematic parameters after eruption. White-light coronagraph images are usually employed by a variety of CME reconstruction techniques that assume more or less complex geometries. This is the first study from our International Space Science Institute (ISSI) team “Understanding Our Capabilities in Observing and Modeling Coronal Mass Ejections”, in which we explore how subjectivity affects the 3D CME parameters that are obtained from the Graduated Cylindrical Shell (GCS) reconstruction technique, which is widely used in CME research. To be able to quantify such uncertainties, the “true” values that are being fitted should be known, which are impossible to derive from observational data. We have designed two different synthetic scenarios where the “true” geometric parameters are known in order to quantify such uncertainties for the first time. We explore this by using two sets of synthetic data: 1) Using the ray-tracing option from the GCS model software itself, and 2) Using 3D magnetohydrodynamic (MHD) simulation data from the Magnetohydrodynamic Algorithm outside a Sphere code. Our experiment includes different viewing configurations using single and multiple viewpoints. CME reconstructions using a single viewpoint had the largest errors and error ranges overall for both synthetic GCS and simulated MHD white-light data. As the number of viewpoints increased from one to two, the errors decreased by approximately 4° in latitude, 22° in longitude, 14° in tilt, and 10° in half-angle. Our results quantitatively show the critical need for at least two viewpoints to be able to reduce the uncertainty in deriving CME parameters. We did not find a significant decrease in errors when going from two to three viewpoints for our specific hypothetical three spacecraft scenario using synthetic GCS white-light data. As we expected, considering all configurations and numbers of viewpoints, the mean absolute errors in the measured CME parameters are generally significantly higher in the case of the simulated MHD white-light data compared to those from the synthetic white-light images generated by the GCS model. We found the following CME parameter error bars as a starting point for quantifying the minimum error in CME parameters from white-light reconstructions: Δθ (latitude)=6° +2° -3° , Δϕ (longitude)=11° +18° -6° , Δγ (tilt)=25° +8° -7° , Δx (half-angle)=10° +12° -6° , Δh (height)=0.6 +1.2 -0.4 R ⨀ , and Δκ (ratio)=0.1 +0.03 -0.02 .

Coronal mass ejections↗

Quantifying Errors in 3D CME Parameters Derived From Synthetic Data Using White-Light Reconstruction Techniques

Current efforts in space weather forecasting of CMEs have been focused on predicting their arrival time and magnetic structure. To make these predictions, methods have been developed to derive the true CME speed, size, position, and mass, among others. Difficulties in determining the input parameters for CME forecasting models arise from the lack of direct measurements of the coronal magnetic fields and uncertainties in estimating the CME 3D geometric and kinematic parameters after eruption. White-light coronagraph images are usually employed by a variety of CME reconstruction techniques that assume more or less complex geometries. This is the first study from our International Space Science Institute (ISSI) team “Understanding Our Capabilities in Observing and Modeling Coronal Mass Ejections”, in which we explore how subjectivity affects the 3D CME parameters that are obtained from the Graduated Cylindrical Shell (GCS) reconstruction technique, which is widely used in CME research. To be able to quantify such uncertainties, the “true” values that are being fitted should be known, which are impossible to derive from observational data. We have designed two different synthetic scenarios where the “true” geometric parameters are known in order to quantify such uncertainties for the first time. We explore this by using two sets of synthetic data: 1) Using the ray-tracing option from the GCS model software itself, and 2) Using 3D magnetohydrodynamic (MHD) simulation data from the Magnetohydrodynamic Algorithm outside a Sphere code. Our experiment includes different viewing configurations using single and multiple viewpoints. CME reconstructions using a single viewpoint had the largest errors and error ranges overall for both synthetic GCS and simulated MHD white-light data. As the number of viewpoints increased from one to two, the errors decreased by approximately 4° in latitude, 22° in longitude, 14° in tilt, and 10° in half-angle. Our results quantitatively show the critical need for at least two viewpoints to be able to reduce the uncertainty in deriving CME parameters. We did not find a significant decrease in errors when going from two to three viewpoints for our specific hypothetical three spacecraft scenario using synthetic GCS white-light data. As we expected, considering all configurations and numbers of viewpoints, the mean absolute errors in the measured CME parameters are generally significantly higher in the case of the simulated MHD white-light data compared to those from the synthetic white-light images generated by the GCS model. We found the following CME parameter error bars as a starting point for quantifying the minimum error in CME parameters from white-light reconstructions: Δθ (latitude)=6° +2° -3° , Δϕ (longitude)=11° +18° -6° , Δγ (tilt)=25° +8° -7° , Δx (half-angle)=10° +12° -6° , Δh (height)=0.6 +1.2 -0.4 R ⨀ , and Δκ (ratio)=0.1 +0.03 -0.02 .

Coronal mass ejections↗

DECADE+DES Y3 Weak Lensing Mass Map: A 13,000 deg$^2$ View of Cosmic Structure from 270 Million Galaxies

We present the largest galaxy weak lensing mass map of the late-time Universe, reconstructed from 270 million galaxies in the DECADE and DES Year 3 datasets, covering 13,000 square degrees. We validate the map through systematic tests against observational conditions (depth, seeing, etc.), finding the map is statistically consistent with no contamination. The large area covered by the mass map makes it a well-suited tool for cosmological analyses, cross-correlation studies and the identification of large-scale structure features. We demonstrate its potential by detecting cosmic filaments directly from the mass map for the first time and validating them through their association with galaxy clusters selected using the Sunyaev-Zeldovich effect from Planck and ACT DR6.

Gatti, M. [Chicago U., KICP] (ORCID:00000001613487↗

Optically probing Al—O and O—H vibrations to characterize water adsorption and surface reconstruction on α-alumina: An experimental and theoretical study

Oxide/water interfaces are ubiquitous in a wide variety of applications and the environment. Despite this ubiquity, and attendant decades of study, gaining molecular level insight into water/oxide interaction has proven challenging. In part, this challenge springs from a lack of tools to concurrently characterize changes in surface structure (i.e., water/oxide interaction from the perspective of the solid) and O—H population and local environment (i.e., water/oxide interaction from the water perspective). Here, we demonstrate the application of surface specific vibrational spectroscopy to the characterization of the interaction of the paradigmatic α-Al{sub 2}O{sub 3}(0001) surface and water. By probing both the interfacial Al—O (surface phonon) and O—H spectral response, we characterize this interaction from both perspectives. Through electronic structure calculation, we assign the interfacial Al—O response and rationalize its changes on surface dehydroxylation and reconstruction. Because our technique is all-optical and interface specific, it is equally applicable to oxide surfaces in vacuum, ambient atmospheres and at the solid/liquid interface. Application of this approach to additional alumina surfaces and other oxides thus seems likely to significantly expand our understanding of how water meets oxide surfaces and thus the wide variety of phenomena this interaction controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acquisition of STEM Images by Adaptive Compressive Sensing

Compressive Sensing (CS) allows a signal to be sparsely measured first and accurately recovered later in software [1]. In scanning transmission electron microscopy (STEM), it is possible to compress an image spatially by reducing the number of measured pixels, which decreases electron dose and increases sensing speed [2,3,4]. The two requirements for CS to work are: (1) sparsity of basis coefficients and (2) incoherence of the sensing system and the representation system. However, when pixels are missing from the image, it is difficult to have an incoherent sensing matrix. Nevertheless, dictionary learning techniques such as Beta-Process Factor Analysis (BPFA) [5] are able to simultaneously discover a basis and the sparse coefficients in the case of missing pixels. On top of CS, we would like to apply active learning [6,7] to further reduce the proportion of pixels being measured, while maintaining image reconstruction quality. Suppose we initially sample 10% of random pixels. We wish to select the next 1% of pixels that are most useful in recovering the image. Now, we have 11% of pixels, and we want to decide the next 1% of “most informative” pixels. Active learning methods are online and sequential in nature. Our goal is to adaptively discover the best sensing mask during acquisition using feedback about the structures in the image. In the end, we hope to recover a high quality reconstruction with a dose reduction relative to the non-adaptive (random) sensing scheme. In doing this, we try three metrics applied to the partial reconstructions for selecting the new set of pixels: (1) variance, (2) Kullback-Leibler (KL) divergence using a Radial Basis Function (RBF) kernel, and (3) entropy. Figs. 1 and 2 display the comparison of Peak Signal-to-Noise (PSNR) using these three different active learning methods at different percentages of sampled pixels. At 20% level, all the three active learning methods underperform the original CS without active learning. However, they all beat the original CS as more of the “most informative” pixels are sampled. One can also argue that CS equipped with active learning requires less sampled pixels to achieve the same value of PSNR than CS with pixels randomly sampled, since all the three PSNR curves with active learning grow at a faster pace than that without active learning. For this particular STEM image, by observing the reconstructed images and the sensing masks, we find that while the method based on RBF kernel acquires samples more uniformly, the one on entropy samples more areas of significant change, thus less uniformly. The KL-divergence method performs the best in terms of reconstruction error (PSNR) for this example [8].

Xie, Weiyi↗

Effect of Annealing on Direct Recycled NMC Cathodes

A substantial number of electric vehicle batteries are poised to reach end-of-life conditions in the next decade. Direct recycling has advantages over typical recycling processes because it preserves the chemical structure of the material. One key step of direct recycling materials like nickel manganese cobalt oxide (NMC) cathodes is relithiation, which includes replacing the depleted lithium inventory in the cathode and annealing the material to fix crystallographic degradation. This work uses multiple characterization techniques (synchrotron X-ray diffraction, Ni X-ray absorption near edge structure, scanning transmission electron microscopy) to understand the lithiation mechanism of degraded and chemically relithiated NMC 622. Despite the necessary reconstruction after relithiation being limited to the surface of the degraded NMC 622, a high annealing temperature of 720 °C is still necessary to restore the NMC 622 structure back to pristine condition after relithiation. This work also finds that treating degraded NMC 622 with an annealing step is sufficient to restore key electrochemical and structural properties, other essential features of pristine NMC 622 material such as particle porosity and morphology are largely unaffected. Understanding the effect of this annealing step has important implications on defining the degree of success of any given direct recycling strategy.

36 MATERIALS SCIENCE↗

Structural principles of distinct assemblies of the human α4β2 nicotinic receptor

Fast chemical communication in the nervous system is mediated by neurotransmitter-gated ion channels. The prototypical member of this class of cell surface receptors is the cation-selective nicotinic acetylcholine receptor. As with most ligand-gated ion channels, nicotinic receptors assemble as oligomers of subunits, usually as hetero-oligomers and often with variable stoichiometries. This intrinsic heterogeneity in protein composition provides fine tunability in channel properties, which is essential to brain function, but frustrates structural and biophysical characterization. The α4β2 subtype of the nicotinic acetylcholine receptor is the most abundant isoform in the human brain and is the principal target in nicotine addiction. This pentameric ligand-gated ion channel assembles in two stoichiometries of α- and β-subunits (2α:3β and 3α:2β). Both assemblies are functional and have distinct biophysical properties, and an imbalance in the ratio of assemblies is linked to both nicotine addiction and congenital epilepsy. Here we leverage cryo-electron microscopy to obtain structures of both receptor assemblies from a single sample. Antibody fragments specific to β2 were used to ‘break’ symmetry during particle alignment and to obtain high-resolution reconstructions of receptors of both stoichiometries in complex with nicotine. Furthermore, the results reveal principles of subunit assembly and the structural basis of the distinctive biophysical and pharmacological properties of the two different stoichiometries of this receptor.

60 APPLIED LIFE SCIENCES↗