Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Human performance benefits gained by dynamic instructions compared to smart PDFs

Human performance benefits gained by dynamic instructions compared to smart PDFs In recent years multiple nuclear utilities have deployed an electronic work management solution to replace the traditional paper-based processes. There are many benefits of electronic work management solutions compared to paper processes, such as a more streamlined review and approval process of work packages and a better way to track and resolve any potential bottlenecks causing delays in the review process. These benefits have been recognized where electronic work management solutions have been successfully deployed. However the utilities also hoped the new solution would help the field worker conduct his/her job more efficiently, correctly, and safely. Unfortunately, the industry is now realizing that the deployed solutions did not fully help them reach that goal. The electronic work management solutions present the work instructions as an electronic copy (i.e., a portable document format (PDF)) of the paper instruction. The PDF versions used in these electronic work management solutions have some ability for data input, notes, and mark-ups, but are unable to provide many additional benefits compared to using paper. In fact, conducting work using a PDF on a tablet can be more cumbersome than with a paper instruction. For example, flipping back and forth in a paper instruction can be time consuming, but it is not at all as frustrating as scrolling back and forth on a tablet or continuously having to navigate between tabs. The researchers at Idaho National Laboratory (INL) approached the next step beyond smart PDFs from a human factors perspective. In close collaboration with multiple utilities they investigated how to present instruction content and how to design the interaction with the instruction to improve the workers performance and efficiency. Their solution is a dynamic presentation of the instruction that guides the worker through the correct path as well as ensuring the worker is on the correct component. The solution also automatically validates input and provides guidance if unexpected conditions are identified. A well-designed solution has the opportunity to vastly reduce the risk of human errors in the field, such as preventing actions on incorrect component or unintentionally skipping steps. The human factors researchers at INL leveraged their expertise, existing human performance tools, and a great amount of involvement from field workers in multiple utilities to develop and evaluate design concepts that will provide the human performance and efficiency benefits that the electronic work management solutions fall short to deliver. This paper will describe in detail how these new design concepts improve human performance.

47 OTHER INSTRUMENTATION↗

MO-A-201-00: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

MO-A-201-01: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

Comparison of multimesh hp-FEM to interpolation and projection methods for spatial coupling of thermal and neutron diffusion calculations

Multiphysics solution challenges are legion within the field of nuclear reactor design and analysis. One major issue concerns the coupling between heat and neutron flow (neutronics) within the reactor assembly. These phenomena are usually very tightly interdependent, as large amounts of heat are quickly produced with an increase in fission events within the fuel, which raises the temperature that affects the neutron cross section of the fuel. Furthermore, there typically is a large diversity of time and spatial scales between mathematical models of heat and neutronics. Indeed, the different spatial resolution requirements often lead to the use of very different meshes for the two phenomena. As the equations are coupled, one must take care in exchanging solution data between them, or significant error can be introduced into the coupled problem. We propose a novel approach to the discretization of the coupled problem on different meshes based on an adaptive multimesh higher-order finite element method (hp-FEM), and compare it to popular interpolation and projection methods. We show that the multimesh hp-FEM method is significantly more accurate than the interpolation and projection approaches considered in this study.

97 MATHEMATICS AND COMPUTING↗

Orbital-optimized MP2.5 and its analytic gradients: Approaching CCSD(T) quality for noncovalent interactions

Orbital-optimized MP2.5 [or simply “optimized MP2.5,” OMP2.5, for short] and its analytic energy gradients are presented. The cost of the presented method is as much as that of coupled-cluster singles and doubles (CCSD) [O(N{sup 6}) scaling] for energy computations. However, for analytic gradient computations the OMP2.5 method is only half as expensive as CCSD because there is no need to solve λ{sub 2}-amplitude equations for OMP2.5. The performance of the OMP2.5 method is compared with that of the standard second-order Møller–Plesset perturbation theory (MP2), MP2.5, CCSD, and coupled-cluster singles and doubles with perturbative triples (CCSD(T)) methods for equilibrium geometries, hydrogen transfer reactions between radicals, and noncovalent interactions. For bond lengths of both closed and open-shell molecules, the OMP2.5 method improves upon MP2.5 and CCSD by 38%–43% and 31%–28%, respectively, with Dunning's cc-pCVQZ basis set. For complete basis set (CBS) predictions of hydrogen transfer reaction energies, the OMP2.5 method exhibits a substantially better performance than MP2.5, providing a mean absolute error of 1.1 kcal mol{sup −1}, which is more than 10 times lower than that of MP2.5 (11.8 kcal mol{sup −1}), and comparing to MP2 (14.6 kcal mol{sup −1}) there is a more than 12-fold reduction in errors. For noncovalent interaction energies (at CBS limits), the OMP2.5 method maintains the very good performance of MP2.5 for closed-shell systems, and for open-shell systems it significantly outperforms MP2.5 and CCSD, and approaches CCSD(T) quality. The MP2.5 errors decrease by a factor of 5 when the optimized orbitals are used for open-shell noncovalent interactions, and comparing to CCSD there is a more than 3-fold reduction in errors. Overall, the present application results indicate that the OMP2.5 method is very promising for open-shell noncovalent interactions and other chemical systems with difficult electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput prediction of eucalypt lignin syringyl/guaiacyl content using multivariate analysis: A comparison between mid-infrared, near-infrared, and Raman spectroscopies for model development

Background: In order to rapidly and efficiently screen potential biofuel feedstock candidates for quintessential traits, robust high-throughput analytical techniques must be developed and honed. The traditional methods of measuring lignin syringyl/guaiacyl (S/G) ratio can be laborious, involve hazardous reagents, and/or be destructive. Vibrational spectroscopy can furnish high-throughput instrumentation without the limitations of the traditional techniques. Spectral data from mid-infrared, near-infrared, and Raman spectroscopies was combined with S/G ratios, obtained using pyrolysis molecular beam mass spectrometry, from 245 different eucalypt and Acacia trees across 17 species. Iterations of spectral processing allowed the assembly of robust predictive models using partial least squares (PLS). Results: The PLS models were rigorously evaluated using three different randomly generated calibration and validation sets for each spectral processing approach. Root mean standard errors of prediction for validation sets were lowest for models comprised of Raman (0.13 to 0.16) and mid-infrared (0.13 to 0.15) spectral data, while near-infrared spectroscopy led to more erroneous predictions (0.18 to 0.21). Correlation coefficients (r) for the validation sets followed a similar pattern: Raman (0.89 to 0.91), mid-infrared (0.87 to 0.91), and near-infrared (0.79 to 0.82). These statistics signify that Raman and mid-infrared spectroscopy led to the most accurate predictions of S/G ratio in a diverse consortium of feedstocks. Conclusion: Eucalypts present an attractive option for biofuel and biochemical production. Given the assortment of over 900 different species of Eucalyptus and Corymbia , in addition to various species of Acacia , it is necessary to isolate those possessing ideal biofuel traits. This research has demonstrated the validity of vibrational spectroscopy to efficiently partition different potential biofuel feedstocks according to lignin S/G ratio, significantly reducing experiment and analysis time and expense while providing non-destructive, accurate, global, predictive models encompassing a diverse array of feedstocks.

09 BIOMASS FUELS↗

Pilot Project Technology Business Case: Mobile Work Packages

Performance advantages of the new pilot project technologies are widely acknowledged, but it has proven difficult for utilities to derive business cases for justifying investment in these new capabilities. Lack of a business case is often cited by utilities as a barrier to pursuing wide-scale application of digital technologies to nuclear plant work activities. The decision to move forward with funding usually hinges on demonstrating actual cost reductions that can be credited to budgets and thereby truly reduce O&M or capital costs. Technology enhancements, while enhancing work methods and making work more efficient, often fail to eliminate workload such that it changes overall staffing and material cost requirements. It is critical to demonstrate cost reductions or impacts on non-cost performance objectives in order for the business case to justify investment by nuclear operators. The Business Case Methodology (BCM) was developed in September of 2015 to frame the benefit side of II&C technologies to address the “benefit” side of the analysis—as opposed to the cost side—and how the organization evaluates discretionary projects (net present value (NPV), accounting effects of taxes, discount rates, etc.). The cost and analysis side is not particularly difficult for the organization and can usually be determined with a fair amount of precision (not withstanding implementation project cost overruns). It is in determining the “benefits” side of the analysis that utilities have more difficulty in technology projects and that is the focus of this methodology. The methodology is presented in the context of the entire process, but the tool provided is limited to determining the organizational benefits only. This report describes a the use of the BCM in building a business case for mobile work packages, which includes computer-based procedures and other automated elements of a work package. Key to those impacts will be identifying where the savings are “harvestable,” meaning they result in an actual reduction in headcount and/or cost. The report describes the specific activities conducted with a partner utility to examine the various work activities associated with mobile work packages to determine what time savings and error rate reductions are available. The report summarizes these findings in the form of a business case for the technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Criticality Safety Lessons Learned in the Design of the Uranium Processing Facility at the Y-12 National Security Complex

The Uranium Processing Facility (UPF) is being built by the National Nuclear Security Administration (NNSA) to replace aging uranium processes at the Y-12 National Security Complex (Y-12 NSC) in Oak Ridge Tennessee. Specifically, the processes housed in building 9212 are being replaced as this facility dates to the World War II Manhattan Project days of Y-12. When the UPF Project is completed it will consist of three main facilities along with several support facilities. The Main Processing Building (MPB) will house oxide production and metal casting operations. The Salvage and Accountability Building (SAB) will house wet chemistry operations (examples include recovery evaporation and calcination of solutions). The Personnel Support Building will be connected to both the SAB and the MPB and will serve as a transition facility for materials and personnel between the two. The MPB will also be connected to the Highly Enriched Uranium Materials Storage Facility (HEUMF) via a connector (HCON) to permit transfers from storage into UPF directly. This paper will summarize some of the more important lessons learned for the NCS practitioner working in a design environment rather than in a production or experimental environment. As the Chief NCS Engineer for the UPF Project I have been responsible for ensuring the technical evaluations produced on the project are high quality, technically accurate, and conform to the Y-12 NCS Program expectations. Ensuring nuclear criticality safety for processes that do not yet exist in reality is a challenge very different than that of ensuring subcriticality for processes in an operating facility. The biggest difference being that in design space – everything is imaginary whereas in the operating facility you have the benefit of being able to go out and look at the equipment and interview the operators. Ensuring that Nuclear Criticality Safety is integrated into design is a process that requires constant communication between the NCS staff and the broader engineering design team. Until the facility is constructed – nothing is physically stable and so rigorous documentation of decisions – to include any assumptions – is necessary to minimize errors. Non-NCS engineers will not understand the hazard or the physics of nuclear criticality. It is up to the NCS staff to provide training and communication to the team. The NCS staff must be patient and prepared to explain themselves many times and be as flexible as possible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Qubit Assignment Using Time Reversal

As quantum computers with large numbers of qubits become increasingly available, experiments executed on a given device may not utilize all available qubits. In this case, the outcome of executing a quantum program will depend on the ability to efficiently select a subset of high-performing physical qubits. For any given quantum program and device there are many ways to assign physical qubits for execution of the program, and assignments will differ in performance due to the variability in quality across qubits and entangling operations on a single device. Evaluating the performance of each assignment using fidelity estimation introduces significant experimental overhead and will be infeasible for many applications, while relying on standard device benchmarks provides incomplete information about the performance of any specific program. Furthermore, the number of possible assignments grows combinatorially in the number of qubits on the device and in the program, motivating the use of heuristic optimization techniques. We demonstrate a practical solution to the problem of qubit assignment by using simulated annealing with a cost function based on the Loschmidt echo, a diagnostic that measures the reversibility of a quantum process. We provide theoretical justification for this choice of cost function by demonstrating that the optimal qubit assignment coincides with the optimal qubit assignment based on state fidelity in the weak error limit, and we provide experimental justification using diagnostics performed on Google’s superconducting qubit devices. We then establish the performance of simulated annealing for qubit assignment using classical simulations of noisy devices as well as optimization experiments performed on a quantum processor. Our results demonstrate that the use of Loschmidt echoes and simulated annealing provides a scalable and flexible approach to optimizing qubit assignment on near-term hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated Work Package: Initial Wireless Communication Platform Design, Development, and Evaluation

The Department of Energy’s Light Water Reactor Sustainability Program is developing the scientific basis to ensure long-term reliability, productivity, safety, and security of the nuclear power industry in the United States. The Instrumentation, Information, and Control (II&C) pathway of the program aims to increase the role of advanced II&C technologies to achieve this objective. One of the pathway efforts at Idaho National Laboratory (INL) is to improve the work packages execution process by replacing the expensive, inefficient, bulky, complex, and error-prone paper-based work orders with automated work packages (AWPs). An AWP is an automated and dynamic presentation of the work package designed to guide the user through the work process. It is loaded on a mobile device, such as a tablet, and is capable of communicating with plant equipment and systems to acquire plant and procedure states. The AWP replaces those functions where a computer is more efficient and reliable than a human. To enable the automatic acquisition of plant data, it is necessary to design and develop a prototype platform for data exchange between the field instruments and the AWP mobile devices. The development of the platform aims to reveal issues and solutions generalizable to large-scale implementation of a similar system. Topics such as bandwidth, robustness, response time, interference, and security are usually associated with wireless communication. These concerns, along with other requirements, are listed in an earlier INL report. Specifically, the targeted issues and performance aspects in this work are relevant to the communication infrastructure from the perspective of promptness, robustness, expandability, and interoperability with different technologies.

Automated Work Packages↗

Modeling the effect of wind speed and direction shear on utility‐scale wind turbine power production

Abstract Wind speed and direction variations across the rotor affect power production. As utility‐scale turbines extend higher into the atmospheric boundary layer (ABL) with larger rotor diameters and hub heights, they increasingly encounter more complex wind speed and direction variations. We assess three models for power production that account for wind speed and direction shear. Two are based on actuator disc representations, and the third is a blade element representation. We also evaluate the predictions from a standard power curve model that has no knowledge of wind shear. The predictions from each model, driven by wind profile measurements from a profiling LiDAR, are compared to concurrent power measurements from an adjacent utility‐scale wind turbine. In the field measurements of the utility‐scale turbine, discrete combinations of speed and direction shear induce changes in power production of −19% to +34% relative to the turbine power curve for a given hub height wind speed. Positive speed shear generally corresponds to over‐performance and increasing magnitudes of direction shear to greater under‐performance, relative to the power curve. Overall, the blade element model produces both higher correlation and lower error relative to the other models, but its quantitative accuracy depends on induction and controller sub‐models. To further assess the influence of complex, non‐monotonic wind profiles, we also drive the models with best‐fit power law wind speed profiles and linear wind direction profiles. These idealized inputs produce qualitative and quantitative differences in power predictions from each model, demonstrating that time‐varying, non‐monotonic wind shear affects wind power production.

Energy & Fuels↗

WE-G-BRF-08: Robust Characterization and Patient Experience of a Time-Resolved Ultrasound System for Prostate Tracking

Purpose: Characterization of a time resolved ultrasound device (4D-US), used for localization and motion monitoring of prostate radiotherapy. Methods: The 4D-US system accuracy to reproduce prostate motion was investigated and artifacts were determined under detailed experimental and ultimately clinical conditions. Two fields of view (FOV) of 30 and 60 degrees and two corresponding acquisition speeds were evaluated under experimental conditions with gradual increased complexity. The reconstruction ability and trajectory tracking depends on the relative speed between the ultrasound probe and the moving object. Two different types of phantoms were developed; one capable of following a predetermined trajectory with variable speeds, and a second one designed to test the US ability to a track dynamically-deformed prostate. Four hypo-prostate patients (10fx) were monitored during the treatment to detect intrafraction motion. Results: Prostate speeds up to 6mm/s and 3mm/s can be successfully tracked by the system when using the small and large FOV, respectively. The system response time, calculated based on the speedinduced volumetric distortion, is dependent on the FOV, with 1.1s for the small FOV and 1.4s for the large FOV. The response time was also found dependent on the size of target, increasing from 1.4s to 1.7s for target diameters of 4cm to 2.8cm. The deformable dynamic phantom has shown that the system is able to successfully follow a highly-deformed, slowmoving prostate with an error < 0.5mm. The overall range of patient intrafraction motion was (−2.4 to 2.2)mm, (−2.6 to 2.4)mm, (−3.0 to 4.3)mm in the RL, SI and AP directions, respectively. Conclusion: The 4DUS system using a large FOV is appropriate to monitor the prostate motion as well as the adjacent organs at risk. However, infrequent abrupt motion can be problematic and the small FOV system is preferred for such patients, particularly for future applications as online prostate monitoring employed for MLC tracking.

60 APPLIED LIFE SCIENCES↗

Z-checker: A framework for assessing lossy compression of scientific data

Because of the vast volume of data being produced by today’s scientific simulations and experiments, lossy data compressor allowing user-controlled loss of accuracy during the compression is a relevant solution for significantly reducing the data size. However, lossy compressor developers and users are missing a tool to explore the features of scientific data sets and understand the data alteration after compression in a systematic and reliable way. To address this gap, we have designed and implemented a generic framework called Z-checker. On the one hand, Z-checker combines a battery of data analysis components for data compression. On the other hand, Z-checker is implemented as an open-source community tool to which users and developers can contribute and add new analysis components based on their additional analysis demands. In this article, we present a survey of existing lossy compressors. Then, we describe the design framework of Z-checker, in which we integrated evaluation metrics proposed in prior work as well as other analysis tools. Specifically, for lossy compressor developers, Z-checker can be used to characterize critical properties (such as entropy, distribution, power spectrum, principal component analysis, and autocorrelation) of any data set to improve compression strategies. For lossy compression users, Z-checker can detect the compression quality (compression ratio and bit rate) and provide various global distortion analysis comparing the original data with the decompressed data (peak signal-to-noise ratio, normalized mean squared error, rate–distortion, rate-compression error, spectral, distribution, and derivatives) and statistical analysis of the compression error (maximum, minimum, and average error; autocorrelation; and distribution of errors). Z-checker can perform the analysis with either coarse granularity (throughout the whole data set) or fine granularity (by user-defined blocks), such that the users and developers can select the best fit, adaptive compressors for different parts of the data set. Z-checker features a visualization interface displaying all analysis results in addition to some basic views of the data sets such as time series. To the best of our knowledge, Z-checker is the first tool designed to assess lossy compression comprehensively for scientific data sets.

97 MATHEMATICS AND COMPUTING↗

X-ray and optical correlation of type I Seyfert NGC 3516 studied with Suzaku and Japanese ground-based telescopes

From 2013 April to 2014 April, we performed X-ray and optical simultaneous monitoring of the type 1.5 Seyfert galaxy NGC 3516. We employed Suzaku and five Japanese ground-based telescopes—the Pirka, Kiso Schmidt, Nayuta, MITSuME, and the Kanata telescopes. The Suzaku observations were conducted seven times with various intervals ranging from days or weeks to months, with an exposure of ∼50 ks each. The optical B-band observations not only covered those of Suzaku almost simultaneously, but also followed the source as frequently as possible. As a result, NGC 3516 was found in its faint phase with a 2–10 keV flux of 0.21–2.70 × 10{sup −11} erg s{sup −1} cm{sup −2}. The 2–45 keV X-ray spectra were composed of a dominant variable hard power-law (PL) continuum with a photon index of ∼1.7 and a non-relativistic reflection component with a prominent Fe–Kα emission line. Producing the B-band light curve by differential image photometry, we found that the B-band flux changed by ∼2.7 × 10{sup −11} erg s{sup −1} cm{sup −2}, which is comparable to the X-ray variation, and we detected a significant flux correlation between the hard PL component in X-rays and the B-band radiation, for the first time in NGC 3516. By examining their correlation, we found that the X-ray flux preceded that in the B band by 2.0{sub −0.6}{sup +0.7} days (1σ error). Although this result supports the X-ray reprocessing model, the derived lag is too large to be explained by the standard view, which assumes a “lamppost”-type X-ray illuminator located near a standard accretion disk. Our results are better explained by assuming a hot accretion flow and a truncated disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating simplifications of subsurface process representations for field-scale permafrost hydrology models

Abstract. Permafrost degradation within a warming climate poses a significant environmental threat through both the permafrost carbon feedback and damage to human communities and infrastructure. Understanding this threat relies on better understanding and numerical representation of thermo-hydrological permafrost processes and the subsequent accurate prediction of permafrost dynamics. All models include simplified assumptions, implying a tradeoff between model complexity and prediction accuracy. The main purpose of this work is to investigate this tradeoff when applying the following commonly made assumptions: (1) assuming equal density of ice and liquid water in frozen soil, (2) neglecting the effect of cryosuction in unsaturated freezing soil, and (3) neglecting advective heat transport during soil freezing and thaw. This study designed a set of 62 numerical experiments using the Advanced Terrestrial Simulator (ATS v1.2) to evaluate the effects of these choices on permafrost hydrological outputs, including both integrated and pointwise quantities. Simulations were conducted under different climate conditions and soil properties from three different sites in both column- and hillslope-scale configurations. Results showed that amongst the three physical assumptions, soil cryosuction is the most crucial yet commonly ignored process. Neglecting cryosuction, on average, can cause 10 %–20 % error in predicting evaporation, 50 %–60 % error in discharge, 10 %–30 % error in thaw depth, and 10 %–30 % error in soil temperature at 1 m beneath the surface. The prediction error for subsurface temperature and water saturation is more obvious at hillslope scales due to the presence of lateral flux. By comparison, using equal ice–liquid density has a minor impact on most hydrological metrics of interest but significantly affects soil water saturation with an averaged 5 %–15 % error. Neglecting advective heat transport presents the least error, 5 % or even much lower, in most metrics of interest for a large-scale Arctic tundra system without apparent influence caused by localized groundwater flow, and it can decrease the simulation time at hillslope scales by 40 %–80 %. By challenging these commonly made assumptions, this work provides permafrost hydrology scientists an important context for understanding the underlying physical processes, including allowing modelers to better choose the appropriate process representation for a given modeling experiment.

54 ENVIRONMENTAL SCIENCES↗

Surrogate Models for TREAT Transient Calculations

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) is currently preparing for resumption of operation after more than 20 years in a long-term standby state. In parallel with preparation for operations and a new transient testing program, the DOENE Advanced Modeling and Simulation program (NEAMS) has been supporting the development of three-dimensional transient multi-physics modeling capabilities within the reactor physics application MAMMOTH. Recently, the MAMMOTH reactor physics team has begun development of uncertainty and sensitivity analysis for the TREAT core. This research will be used to support the analysis of reactor operation and experiment planning. Traditional approaches, i.e., Monte Carlo simulations, for such tasks require a large number of model evaluations under both steady state and transient conditions. However, exhaustive sets of sampling runs are simply not practical for TREAT since evaluations of each model can take a substantial amount of time. A solution to this problem is to build a surrogate model employing a smaller number of model evaluations. The surrogate model is designed to provide an accurate and fast approximation to the detailed TREAT model. In this manner, the surrogate model can be used in place of the TREAT transient model for uncertainty and sensitivity analysis at a fraction of the computational cost. The high dimensional model representation (HDMR) method is employed here for approximating the responses of interest in terms of functions of lower dimensions. This method has been implemented in RAVEN and all TREAT transient calculations are performed using the multiphysics code MAMMOTH. In addition, a code interface has also been developed in order to couple RAVEN with MAMMOTH. The surrogate model is then tested and compared for TREAT startup testing program Transient Test no. 15 core, and its accuracy is measured by its ability to estimate the mean, coefficient of variance, skewness, excess kurtosis and probability density function of the outputs of Transient Test no. 15 model, as well as root mean square error metric.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CRITICAL EVALUATION OF MAGNETIC FIELD DETECTIONS REPORTED FOR PULSATING B-TYPE STARS IN LIGHT OF ESPaDOnS, NARVAL, AND REANALYZED FORS1/2 OBSERVATIONS

Recent spectropolarimetric studies of seven slowly pulsating B (SPB) and {beta} Cep stars have suggested that photospheric magnetic fields are more common in B-type pulsators than in the general population of B stars, suggesting a significant connection between magnetic and pulsational phenomena. We present an analysis of new and previously published spectropolarimetric observations of these stars. New Stokes V observations obtained with the high-resolution ESPaDOnS and Narval instruments confirm the presence of a magnetic field in one of the stars ({epsilon} Lup), but find no evidence of magnetism in five others. A re-analysis of the published longitudinal field measurements obtained with the low-resolution FORS1/2 spectropolarimeters finds that the measurements of all stars show more scatter from zero than can be attributed to Gaussian noise, suggesting the presence of a signal and/or systematic underestimation of error bars. Re-reduction and re-measurement of the FORS1/2 spectra from the ESO archive demonstrates that small changes in reduction procedure lead to substantial changes in the inferred longitudinal field, and substantially reduces the number of field detections at the 3{sigma} level. Furthermore, we find that the published periods are not unique solutions to the time series of either the original or the revised FORS1/2 data. We conclude that the reported field detections, proposed periods, and field geometry models for {alpha} Pyx, 15 CMa, 33 Eri, and V1449 Aql are artifacts of the data analysis and reduction procedures, and that magnetic fields at the reported strength are no more common in SPB/{beta} Cep stars than in the general population of B stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the impact of glycolate on arp and mcu operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5,000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5,000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similarly to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. In addition to the MST and mMST testing, testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5,000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests. (A single data point in the 5,000 ppm test is physically impossible and SRNL is currently resolving this obvious error.) At this time, SRNL concludes that the presence of up to 10,000 ppm of glycolate does not affect cesium removal by the current solvent system used in the MCU. Although not tested, the impact of glycolate for the Next Generation Solvent - that replaces BOBCalixC6 with MaxCalix - is expected to be very similar to that for the baseline solvent. Testing is needed to confirm. Additional testing is recommended to both further examine the nature of the interaction of glycolate with MST and mMST and also to help address some postulated risks on ARP/MCU operations with implementation of the glycolate flowsheet. The additional testing includes FTIR and Raman spectroscopy to examine the surface of the MST and mMST particles, iodometric titrations to determine the peroxide content in the mMST before and after exposure to glycolate, particle size measurements of the MST and mMST from the experiments performed with glycolate, and measurements of soluble Ti in the supernate from these glycolate experiments. With regards to MCU impacts, the following tests are also recommended based on the premortem risk assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗