Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Smolt Responses to Hydrodynamic Conditions in Forebay Flow Nets of Surface Flow Outlets, 2007

This study provides information on juvenile salmonid behaviors at McNary and The Dalles dams that can be used by the USACE, fisheries resource managers, and others to support decisions on long-term measures to enhance fish passage. We researched smolt movements and ambient hydrodynamic conditions using a new approach combining simultaneous acoustic Doppler current profiler (ADCP) and acoustic imaging device (AID) measurements at surface flow outlets (SFO) at McNary and The Dalles dams on the Columbia River during spring and summer 2007. Because swimming effort vectors could be computed from the simultaneous fish and flow data, fish behavior could be categorized as passive, swimming against the flow (positively rheotactic), and swimming with the flow (negatively rheotactic). We present bivariate relationships to provide insight into fish responses to particular hydraulic variables that engineers might consider during SFO design. The data indicate potential for this empirical approach of simultaneous water/fish measurements to lead to SFO design guidelines in the future.

13 HYDRO ENERGY↗

Closed-loop control of active nematic flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware/software/wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Nishiyama, Katsu [Brandeis Univ., Waltham, MA (Uni↗

Development and Calibration of an Online Energy Model for AHU Fan

The model development is necessary for the study of the energy consumption of Heating, Ventilation, and Air Conditioning (HVAC) systems. To predict the HVAC energy consumption accurately, one needs to model the individual HVAC components either from the measured data or based on the knowledge of the underlying physical phenomenon. Online model characterization is critical for improving the performance of real-time model-based fault detection and diagnosis (FDD) strategies. For HVAC control, models can be used to optimize the supervisory and local feedback control strategies to improve the energy consumption efficiency, or for providing ancillary services to the grid. It has been reported that, fans in HVAC systems of commercial buildings alone can provide substantial frequency regulation service, with little change in the indoor environment. In this paper, a real-time data-driven Air Handling Unit (AHU) fan model was developed based on recursive multi regression model. A generic nonlinear polynomial model has been studied to cover scenarios with different combinations of measurement variables, variable orders as well as different training and prediction horizons. Typical measurements including static pressure, mass flow rate, and damper positions are utilized as inputs to model the power consumption of the fan. The developed models have been validated both with simulation data from EnergyPlus-Dymola co-simulation model and with field measurement data for small to medium commercial buildings. The validation results show that the online model proposed can provide an effective prediction of the AHU fan power consumption.

Dong, Jin↗

A Modeling Tool to Analyze the Performance of Industrial Cooling Towers

Energy efficiency and energy savings have become an important factor as industries look for ways to save energy and minimize their energy consumption while reducing their carbon footprint. Cooling towers are utilized significantly in industries for either serving chillers or process cooling. Depending on the size of the cooling tower, it can use a surprising amount of energy and water, which is why it is crucial to make sure that the facility has optimized their cooling tower.A modeling tool has been developed to perform a thorough analysis of a cooling tower and its various operations to ensure that the facility has optimized its cooling tower. This model analyzes an annual base case in comparison with the revised case of a cooling tower operation. This modeling tool simulates 8,760 hourly calculations for fan power for various fan controls, water consumption, and pumping energy consumption and demand based on the user’s location and its corresponding Typical Meteorological Year 3 (TMY3) weather data. This model is capable to simulate up to five cooling tower cells as one large tower utilizing one pump or parallel pumping. The successful validated cooling tower model should assist industry to save energy at their facility through their cooling tower, whether they use it for process cooling or heating, ventilation and air conditioning (HVAC) applications. The entering/leaving water temperatures based on a monthly operating schedule or a wet-bulb temperature schedule will be used as inputs, and the model can calculate savings in energy for various conditions including variable-frequency drive (VFD) on the fan/pump, drift eliminators, number of cycles of concentration, reduced water flow rate, etc.

Hooper, Josh↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

High Spectral Resolution X-ray Observation of Magnetic CVs: EX Hya

In magnetic cataclysmic variables (CVs) the primary is a highly magnetized white dwarf (WD) whose field controls the accretion flow close to the WD, leading to a shock and accretion column that radiate chiefly in X-rays. We present preliminary results from a 500 ks Chandra HETG observation of the brightest magnetic CV EX Hya. From the observational dataset we are able to measure the temperature and density at different points of the cooling accretion column using sensitive line ratios. We also construct line-based light curves to search for rotational modulation of the X-ray emission.

99 GENERAL AND MISCELLANEOUS↗

Seasonal changes in the drivers of water physico-chemistry variability of a small freshwater tidal river

Where rivers meet the sea, tides can exert a physical and chemical influence on the lower reaches of a river. How tidal dynamics in these tidal river reaches interact with upstream hydrological drivers such as storm rainfall, which ultimately determines the quantity and composition of material transferred from watersheds to estuaries, is currently unknown. We monitored a small freshwater tidal river in the Pacific Northwest, USA in high resolution over one year to evaluate the relative importance of tides versus upstream hydrological flows (i.e., base flow and precipitation events) on basic physico-chemical parameters (pH, dissolved oxygen, turbidity, specific conductivity, and temperature), and how these interactions relate to the downstream estuary. Tidal variability and diurnal cycles (i.e. solar radiation) dominated water physico-chemical variability in the summer, but the influence of these drivers was overshadowed by storm-driven sharp pulses in river physico-chemistry during the remainder of the year. Within such events, we found incidences of counterclockwise hysteresis of pH, counterclockwise hysteresis of dissolved oxygen, and clockwise hysteresis of turbidity, although systematic trends were not observed across events. The dominance of storm rainfall in the river’s physico-chemistry dynamics, and similar pulses of decreased pH observed in adjacent estuarine waters, suggest that the linkage between tidal streams and the broader system is variable throughout the year. High-frequency monitoring of tidal river biogeochemistry is therefore crucial to enable the assessment of how the relative strength of these drivers may change with future sea level rise and altered precipitation patterns to modulate biogeochemical dynamics across the land-ocean-atmosphere continuum.

aquatic↗

The 2014–2017 outburst of the young star ASASSN-13db: A time-resolved picture of a very-low-mass star between EXors and FUors*

Context. Accretion outbursts are key elements in star formation. ASASSN-13db is a M5-type star with a protoplanetary disk, the lowest-mass star known to experience accretion outbursts. Since its discovery in 2013, it has experienced two outbursts, the second of which started in November 2014 and lasted until February 2017. Aims. We observe the photometric and spectroscopic behavior of ASASSN-13db during the 2014–2017 outburst. Methods. We use high- and low-resolution spectroscopy and time-resolved photometry from the ASAS-SN survey, the LCOGT and the Beacon Observatory to study the light curve of ASASSN-13db and the dynamical and physical properties of the accretion flow. Results. The 2014–2017 outburst lasted for nearly 800 days. A 4.15 d period in the light curve likely corresponds to rotational modulation of a star with hot spot(s). The spectra demonstrate multiple emission lines with variable inverse P-Cygni profiles and a highly variable blue-shifted absorption below the continuum. Line ratios from metallic emission lines (Fe I/Fe II, Ti I/Ti II) suggest temperatures of ~5800–6000 K in the accretion flow. Conclusions. Photometrically and spectroscopically, the 2014–2017 event displays an intermediate behavior between EXors and FUors. The accretion rate ([$\dot{M}$]= 1–3 × 10 -7 M ⊙ /yr), about two orders of magnitude higher than the accretion rate in quiescence, is not vastly different from the accretion rate observed in 2013. The absorption features in the spectra suggest that the system is viewed at a high angle and drives a powerful, non-axisymmetric wind, maybe related to magnetic reconnection. The properties of ASASSN-13db suggest that temperatures lower than those for solar-type stars are needed for modeling accretion in very-low-mass systems. Finally, the rotational modulation during the outburst reveals that accretion-related structures settle after the beginning of the outburst and can be relatively stable and long-lived. Our work also demonstrates the power of time-resolved photometry and spectroscopy to explore the properties of variable and outbursting stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Hydrodynamics Test Problems with Linear Velocity Profiles

As an extension of the works of Coggeshall and Ramsey, a class of analytic solutions to the radiation hydrodynamics equations is derived for code verification purposes. These solutions are valid under assumptions including diffusive radiation transport, a polytropic gas equation of state, constant conductivity, separable flow velocity proportional to the curvilinear radial coordinate, and divergence-free heat flux. In accordance with these assumptions, the derived solution class is mathematically invariant with respect to the presence of radiative heat conduction, and thus represents a solution to the compressible flow (Euler) equations with or without conduction terms included. With this solution class, a quantitative code verification study (using spatial convergence rates) is performed for the cell-centered, finite volume, Eulerian compressible flow code xRAGE developed at Los Alamos National Laboratory. Simulation results show near second order spatial convergence in all physical variables when using the hydrodynamics solver only, consistent with that solver's underlying order of accuracy. However, contrary to the mathematical properties of the solution class, when heat conduction algorithms are enabled the calculation does not converge to the analytic solution.

97 MATHEMATICS AND COMPUTING↗

Hydrodynamic characterization of the coastal pioneer array ocean observing system

Ocean observation buoys require relatively small amounts of power, yet traditionally necessitate costly resupply trips for battery replacement. With the offshore location of the buoys and small power requirements, wave energy may be an effective solution for providing consistent and reliable power to support the buoy instrumentation. The US National Science Foundation Ocean Observatories Initiative (OOI) includes arrays of point absorber-like buoy systems used for ocean observation that have been deployed at multiple locations including the Southern Mid-Atlantic Bight. A study is currently underway to design a pitch resonator wave energy converter to supplement existing renewable energy generation for powering observation instrumentation. This paper details field measurements from surface moorings of the OOI Coastal Pioneer Array, which informs the subsequent development of a numerical model for the moored observation system. The model is developed in Wave Energy Converter Simulator (WEC-Sim), which leverages the Simscape multibody solver within the MATLAB/Simulink framework and linear potential flow theory to simulate the hydrodynamic interactions and multibody dynamics in 6 degrees of freedom. Multiple tuning variables are considered to produce a model for the system that matches well with empirical data (about 8% error). In conclusion, the WEC-Sim model will serve as a platform for integrating the pitch resonator wave energy converter concept and deployment preparation (detailed design including power take-off and control systems, response evaluation, etc.).

hydrodynamic modeling↗

Cost Effective Recovery of Low-TDS Frac Flowback Water for Re-use

The project goal was to develop a cost-effective water recovery process to reduce the costs and envi-ronmental impact of shale gas production. This effort sought to develop both a flowback water pre-treatment process and a membrane-based partial demineralization process for the treatment of the low-Total Dissolved Solids (TDS) portion of the flowback water produced during hydrofracturing operations. The TDS cutoff for consideration in this project is < 35,000 {approx} 45,000 ppm, which is the typical limit for economic water recovery employing reverse osmosis (RO) type membrane desalination processes. The ultimate objective is the production of clean, reclaimed water suitable for re-use in hydrofracturing operations. The team successfully compiled data on flowback composition and other attributes across multiple shale plays, identified the likely applicability of membrane treatment processes in those shales, and expanded the proposed product portfolio to include four options suitable for various reuse or discharge applications. Pretreatment technologies were evaluated at the lab scale and down-selected based upon their efficacy in removing key contaminants. The chosen technologies were further validated by performing membrane fouling studies with treated flowback water to demonstrate the technical feasibility of flowback treatment with RO membranes. Process flow schemes were constructed for each of the four product options based on experimental performance data from actual flowback water treatment studies. For the products requiring membrane treatment, membrane system model-ing software was used to create designs for enhanced water recovery beyond the typical seawater desalination benchmark. System costs based upon vendor and internal cost information for all process flow schemes were generated and are below target and in line with customer expectations. Finally, to account for temporal and geographic variability in flowback characteristics as well as local disposal costs and regulations, a parametric value assessment tool was created to assess the economic attractiveness of a given flowback recovery process relative to conventional disposal for any combination of anticipated flowback TDS and local disposal cost. It is concluded that membrane systems in combination with appropriate pretreatment technologies can provide cost-effective recovery of low-TDS flow-back water for either beneficial reuse or safe surface discharge.

03 NATURAL GAS↗

ABSTRACT: Upscaling Fracture Properties in Support of Dual-permeability Simulations

Rainier Mesa (RM) is a tuffaceous, high-elevation plateau on the Nevada Test Site (NTS) that has been subjected to numerous nuclear tests between 1957 and 1992. Unlike other tests on the NTS located within or just above the saturated zone, tests at the RM T-tunnel complex were conducted within a variably saturated sequence of bedded and non-welded vitric and zeolitized tuff units, located approximately 500 m above the regional groundwater flow system. The low permeability and high porosity of the underlying zeolitized tuff units suggest the downward transport of radionuclides released from these tests are minimal through the tuff matrix. However, numerous faults observed to discharge water into tunnel drifts may serve as preferential pathways for radionuclide migration. Data collected from tunnel drifts indicate that faulting within the zeolitized tuff units is sparse with fractal clustering, and that connectivity between adjacent fault clusters is often weak to non-existent. The sparse fault density at RM, in conjunction with the extreme variability in the spatial distribution of faults, poses challenges not readily addressed by existing upscaling methods that upscale fracture properties as equivalent grid tensors. The unique fault statistics at RM has led to the development of a fracture continuum method designed to faithfully preserve flow and transport properties of the sparse fault networks. This method is based on selective mapping and upscaling of fault hydraulic and transport properties onto a continuum grid in support of dual-permeability simulations. Comparisons of global flow and random walk particle breakthrough between two-dimensional discrete fracture network and fracture continuum simulations demonstrate the utility of this method.

54 ENVIRONMENTAL SCIENCES↗

Final Report: Optimal Model Complexity in Geological Carbon Sequestration: A Response Surface Uncertainty Analysis

The critical component of a risk assessment study in evaluating GCS is an analysis of uncertainty in CO2 modeling. In such analyses, direct numerical simulation of CO2 flow and leakage requires many time-consuming model runs. Alternatively, analytical methods have been developed which allow fast and efficient estimation of CO2 storage and leakage, although restrictive assumptions on formation rock and fluid properties are employed. In this study, an intermediate approach is proposed based on the Design of Experiment and Response Surface methodology, which consists of using a limited number of numerical simulations to estimate a prediction outcome as a combination of the most influential uncertain site properties. The methodology can be implemented within a Monte Carlo framework to efficiently assess parameter and prediction uncertainty while honoring the accuracy of numerical simulations. The choice of the uncertain properties is flexible and can include geologic parameters that influence reservoir heterogeneity, engineering parameters that influence gas trapping and migration, and reactive parameters that influence the extent of fluid/rock reactions. The method was tested and verified on modeling long-term CO2 flow, non-isothermal heat transport, and CO2 dissolution storage by coupling two-phase flow with explicit miscibility calculation using an accurate equation of state that gives rise to convective mixing of formation brine variably saturated with CO2. All simulations were performed using three-dimensional high-resolution models including a target deep saline aquifer, overlying caprock, and a shallow aquifer. To evaluate the uncertainty in representing reservoir permeability, sediment hierarchy of a heterogeneous digital stratigraphy was mapped to create multiple irregularly shape stratigraphic models of decreasing geologic resolutions: heterogeneous (reference), lithofacies, depositional environment, and a (homogeneous) geologic formation. To ensure model equivalency, all the stratigraphic models were successfully upscaled from the reference heterogeneous model for bulk flow and transport predictions (Zhang & Zhang, 2015). GCS simulation was then simulated with all models, yielding insights into the level of parameterization complexity that is needed for the accurate simulation of reservoir pore pressure, CO2 storage, leakage, footprint, and dissolution over both short (i.e., injection) and longer (monitoring) time scales. Important uncertainty parameters that impact these key performance metrics were identified for the stratigraphic models as well as for the heterogeneous model, leading to the development of reduced/simplified models at lower characterization cost that can be used for the reservoir uncertainty analysis. All the CO2 modeling was conducted using PFLOTRAN – a massively parallel, multiphase, multi-component, and reactive transport simulator developed by a multi-laboratory DOE/SciDAC (Scientific Discovery through Advanced Computing) project (Zhang et al., 2017, in review). Within the uncertainty analysis framework, increasing reservoir depth were investigated to explore its effect on the uncertainty outcomes and the potential for developing gravity-stable injection with increased storage security (Dai et al., 20126; Dai et al., 2017, in review). Finally, to accurately model CO2 fluid-rock reactions and resulting long-term storage as secondary carbonate minerals, a modified kinetic rate law for general mineral dissolution and precipitation was proposed and verified that is invariant to a scale transformation of the mineral formula weight. This new formulation will lead to more accurate assessment of mineral storage over geologic time scales (Lichtner, 2016).

58 GEOSCIENCES↗

Flow cytometry-based methods for assessing soluble scFv activities and detecting pathogen antigens in solution

Novel methods are reported for evaluating and utilizing single chain fragment variable (scFv) antibodies derived from yeast-display libraries. Yeast-display was used to select scFv specific to invariant surface glycoproteins (ISG) of Trypanosoma brucei. A limiting step in the isolation of scFv from nonimmune libraries is the conversion of highly active yeast-displayed scFv into soluble antibodies that can be used in standard immunoassays. Challenges include limited solubility or activity following secretion and purification of scFv. For this reason, few scFv derived from yeast-display platforms have moved into development and implementation as diagnostic reagents. To address this problem, assays were developed that employ both yeastdisplayed and secreted scFv as analytical reagents. The first is a competitive inhibition flow cytometry (CIFC) assay that detects secreted scFv by virtue of its ability to competitively inhibit the binding of biotinylated antigen to yeast-displayed scFv. The second is an epitope binning assay that uses secreted scFv toidentify additional yeast-displayed scFv that bind nonoverlapping or noncompeting epitopes on an antigen. The epitope binning assay was used not only to identify sandwich assay pairs with yeast-displayed scFv, but also to identify active soluble scFv present in low concentration in a crude expression extract. Finally, a CIFC assay was developed that bypasses entirely the need for soluble scFv expression, by using yeast displayed scFv to detect unlabeled antigen in samples. These methods will facilitate the continued development and practical implementation of scFv derived from yeast-display libraries.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale Thermal-hydraulic analysis of the MARVEL micro-reactor using coupled MOOSE Subchannel (SCM) and SAM

MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory’s Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor’s primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL’s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiscale Thermal-hydraulic analysis of the MARVEL microreactor using a coupled SAM and SCM simulation. (PPTX)

This is .pptx document presenting a summary of the paper of the same name that has been submitted and accepted to NURETH-21: MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor's primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL?s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗