Search NASA⌕ Search

SEARCH · Search NASA

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of the feeding arteries of hepatocellular carcinomas by performing dual arterial phase CT during pre-transarterial chemoembolization angiography

Purpose: This study evaluated the usefulness of performing dual arterial phase computed tomography (CT) during pre-transarterial chemoembolization (TACE) angiography for identifying the feeding arteries of hepatocellular carcinomas (HCC). Materials and methods: Dual arterial phase CT was performed during pre-TACE angiography in 73 patients with 139 HCC. Ten HCC underwent this procedure twice, so the total number of examined HCC was 149. Early and late arterial phase images were obtained 6 seconds after injection of an iodinated contrast material serially during a single breath-hold. The feeding artery was defined as the branch of the hepatic artery that was connected to the enhanced areas of the tumor. For HCC that could not be visualized on the early arterial phase images, fusion images superimposing the early and late arterial phase images were constructed. Furthermore, technical success defined as successful catheterization of the subsegmental or more distal feeding artery was evaluated. Results: The feeding artery was correctly identified on dual arterial phase CT in 146 of the 149 tumors (98.0%). In two HCC, the feeding arteries could not be identified due to severe motion artifacts, and in one, due to the presence of anastomosis between the right and left hepatic arteries. Catheterization of the subsegmental feeding artery was successful in all TACE procedures (technical success rate: 100%). Conclusion: Performing dual arterial phase CT during angiography appears to be useful for identifying the feeding arteries of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carina up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delay and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functional Imaging of the Foot with Perfusion Angiography in Critical Limb Ischemia

PurposeTo report on the first clinical experience with perfusion angiography (PA) of the foot in patients with chronic critical limb ischemia.Materials and MethodsPA is a post-processing software algorithm and no extra digital subtraction angiography (DSA) has to be performed for this analysis. The data used to test the feasibility of PA were obtained from a consecutive group of 89 patients with CLI who were treated with standard below the knee angioplasty and 12 separate patients who were not suitable for endovascular revascularization.ResultsMotion artifacts in the dataset of the DSA made post-procedural analysis impossible in 10 % intervention. In the majority of patients (59/68) PA showed an increase in volume flow in the foot after successful angioplasty of the crural vessels. However, in 9/68 patients no increase was seen after successful angioplasty. With the use of a local administered competitive α-adrenergic receptor antagonist, it is also possible to test and quantify the capillary resistance index which is a parameter for the remaining functionality of the microcirculation in CLI patients.ConclusionPA might be used as a new endpoint for lower limb revascularization and can also be used to test the functionality the microcirculation to identify sub-types of patients with CLI. Clinical evaluation and standardization of PA is mandatory before introduction in daily practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Novel X-Ray Visible Zein-Based Non-adhesive Precipitating Liquid Embolic HEI{sub E1-2017}: An Exploratory Study

Purpose: To investigate the novel zein-based non-adhesive precipitating liquid embolic HEI{sub E1-2017}. Materials and Methods: Zein-based liquid embolics are an own class of embolization material. In this study, HEI{sub E1-2017}, a novel zein-based liquid embolic, was investigated. Visibility was assessed in vitro in CT and MRI phantoms, embolization characteristics were assessed in vivo in the kidneys of 12 pigs. Components of HEI{sub E1-2017} were zein as occlusion material, ethanol as solvent, and iodized oil as radiopaque material. HEI{sub E1-2017} was used in pure (HEI-PURE) and manually modified (HEI-MOD) form and compared with 6% ethylene vinyl alcohol copolymer (EVOH). Different radiological methods (CT, MRI, DSA, cone-beam CT, and micro-CT) and histopathologic analyses were applied to compare visibility and vascular occlusion patterns. Results: In CT phantoms, all embolics were definitely visible as hyperdense materials. In MRI phantoms, signal-to-noise ratio was highest for HEI-PURE, followed by HEI-MOD and EVOH. In all kidneys, embolization procedures were technically successful and without complications. In DSA, all embolics were definitely visible during and after embolization. Only EVOH caused substantial artifacts in cone-beam CT and CT. In micro-CT and histopathology, HEI-PURE showed a homogeneous occlusion from segmental arteries to glomerular capillaries. HEI-MOD demonstrated the deepest vascular penetration (up to the level of peritubular capillaries), but with an inhomogeneous distribution. For EVOH, there was inhomogeneous vascular occlusion from segmental arteries to glomerular capillaries. Conclusion: HEI{sub E1-2017} is a promising novel zein-based liquid embolic. Further preclinical and clinical studies with higher case numbers and long-term follow-up are needed to further assess the value of this embolic material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Local bilinear computation of Jacobi sets

Abstract We propose a novel method for the computation of Jacobi sets in 2D domains. The Jacobi set is a topological descriptor based on Morse theory that captures gradient alignments among multiple scalar fields, which is useful for multi-field visualization. Previous Jacobi set computations use piecewise linear approximations on triangulations that result in discretization artifacts like zig-zag patterns. In this paper, we utilize a local bilinear method to obtain a more precise approximation of Jacobi sets by preserving the topology and improving the geometry. Consequently, zig-zag patterns on edges are avoided, resulting in a smoother Jacobi set representation. Our experiments show a better convergence with increasing resolution compared to the piecewise linear method. We utilize this advantage with an efficient local subdivision scheme. Finally, our approach is evaluated qualitatively and quantitatively in comparison with previous methods for different mesh resolutions and across a number of synthetic and real-world examples.

97 MATHEMATICS AND COMPUTING↗

Detecting impacts of surface development near weather stations since 1895 in the San Joaquin Valley of California

Abstract Temperature readings observed at surface weather stations have been used for detecting changes in climate due to their long period of observations. The most common temperature metrics recorded are the daily maximum (TMax) and minimum (TMin) extremes. Unfortunately, influences besides background climate variations impact these measurements such as changes in (1) instruments, (2) location, (3) time of observation, and (4) the surrounding artifacts of human civilization (buildings, farms, streets, etc.) Quantifying (4) is difficult because the surrounding infrastructure, unique to each site, often changes slowly and variably and is thus resistant to general algorithms for adjustment. We explore a direct method of detecting this impact by comparing a single station that experienced significant development from 1895 to 2019, and especially since 1970, relative to several other stations with lesser degrees of such development (after adjustments for the (1) to (3) are applied). The target station is Fresno, California (metro population ~ 15,000 in 1900 and ~ 1 million in 2019) situated on the eastern side of the broad, flat San Joaquin Valley in which several other stations reside. A unique component of this study is the use of pentad (5-day averages) as the test metric. Results indicate that Fresno experienced + 0.4 °C decade −1 more nighttime warming (TMin) since 1970 than its neighbors—a time when population grew almost 300%. There was little difference seen in TMax trends between Fresno and non-Fresno stations since 1895 with TMax trends being near zero. A case is made for the use of TMax as the preferred climate metric relative to TMin for a variety of physical reasons. Additionally, temperatures measured at systematic times of the day (i.e., hourly) show promise as climate indicators as compared with TMax and especially TMin (and thus TAvg) due to several complicating factors involved with daily high and low measurements.

54 ENVIRONMENTAL SCIENCES↗

Viscoelastic-Mapping of Cellulose Nanofibrils Using Low-Total-Force Contact Resonance Force Microscopy (LTF-CRFM)

Low-total-force contact resonance force microscopy (LTF-CRFM), an atomic force microscopy method, is introduced as a non-destructive means to quantify the local viscoelastic loss tangent (tan..delta..) of supported cellulose nanofibrils (CNFs). The method limits static and dynamic forces during measurement to minimize substrate and geometry effects and to reduce the potential for stress-induced CNF damage. LTF-CRFM uses Brownian motion to achieve the thermally-limited lowest dynamic force, while approaching adhesive pull-off to achieve the low static force. LTF-CRFM measurements were shown to generate analyzable data without evidence of nonlinear artifacts and without damage to the CNF over static forces ranging from 11.6 to 84.6 nN. The measured tan..delta.. of CNFs was 0.015 +/- 0.0094, which is the first reported tan..delta.. measurement of an isolated CNF. Finally, LTF-CRFM successfully mapped tan..delta.. along the length of CNFs to determine that kink defects along the CNF do not impart a local viscoelastic property change at the spatial resolution of the measurement.

BIOMASS FUELS↗

The impact of socio-technical communication styles on the diversity and innovation potential of global science collaboratories

Emerging cyber-infrastructure tools are enabling scientists to transparently co-develop, share, and communicate about real-time diverse forms of knowledge artifacts. In these environments, communication preferences of scientists are posited as an important factor affecting innovation capacity and robustness of social and knowledge network structures. Scientific knowledge creation in such communities is called global participatory science (GPS). Recently, using agent-based modeling and collective action theory as a basis, a complex adaptive social communication network model (CollectiveInnoSim) is implemented. This work leverages CollectiveInnoSim implementing communication preferences of scientists. Social network metrics and knowledge production patterns are used as proxy metrics to infer innovation potential of emergent knowledge and collaboration networks. The objective is to present the underlying communication dynamics of GPS in a form of computational model and delineate the impacts of various communication preferences of scientists on innovation potential of the collaboration network. Ultimately, the insight gained can help policy-makers to design GPS environments and promote innovation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

An empirical investigation of organic software product lines

Abstract Software product line engineering is a best practice for managing reuse in families of software systems that is increasingly being applied to novel and emerging domains. In this work we investigate the use of software product line engineering in one of these new domains, synthetic biology. In synthetic biology living organisms are programmed to perform new functions or improve existing functions. These programs are designed and constructed using small building blocks made out of DNA. We conjecture that there are families of products that consist of common and variable DNA parts, and we can leverage product line engineering to help synthetic biologists build, evolve, and reuse DNA parts. In this paper we perform an investigation of domain engineering that leverages an open-source repository of more than 45,000 reusable DNA parts. We show the feasibility of these new types of product line models by identifying features and related artifacts in up to 93.5% of products, and that there is indeed both commonality and variability. We then construct feature models for four commonly engineered functions leading to product lines ranging from 10 to 7.5 × 10 20 products. In a case study we demonstrate how we can use the feature models to help guide new experimentation in aspects of application engineering. Finally, in an empirical study we demonstrate the effectiveness and efficiency of automated reverse engineering on both complete and incomplete sets of products. In the process of these studies, we highlight key challenges and uncovered limitations of existing SPL techniques and tools which provide a roadmap for making SPL engineering applicable to new and emerging domains.

97 MATHEMATICS AND COMPUTING↗

Sensitivity Gains, Linearity, and Spectral Reproducibility in Nonuniformly Sampled Multidimensional MAS NMR Spectra of High Dynamic Range.

Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C,15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity and line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high quality artifact-free datasets.

Environmental Molecular Sciences Laboratory↗