Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

A parametric study of slow dynamic nonlinear elasticity with comparisons to models

Several phenomenological models that aspire to quantitative description of anomalous nonlinear mesoscopic elasticity are reviewed and compared with laboratory measurements. This class of nonlinearity, best known perhaps for slow dynamics and aging, is seen widely in imperfectly consolidated granular solids but is not well understood. Typical slow dynamic tests show that a modest conditioning oscillatory "pump" strain depresses material stiffness, which then recovers like the logarithm of time after conditioning ceases. Several phenomenological models based on physical arguments have been proposed that predict the material stiffness response to arbitrary pump strain histories during conditioning and recovery. Approximate closed form and numerical solutions to the models are presented that predict the quantitative influence of three key pump parameters: the pump's strain amplitude, the pump's strain rate, and the pump’s duration. Laboratory measurements on Berea sandstone, concrete and a confined single aluminum bead find that slow dynamic responses are linear in pump strain and independent of pump frequency. Measurements also show that, after pump-off, stiffness recovers over times far longer than the pump duration. These observations and others are compared to model predictions. One of the considered models, based on a picture of fast brittle damage and slow healing, successfully matches all these behaviors.

36 MATERIALS SCIENCE

A Data-Driven Method for Modeling Creep-Fatigue Stress- Strain Behavior Using Neural ODEs

In this paper, we introduce a data-driven machine learning approach for modeling one-dimensional stress–strain behavior under cyclic loading, utilizing experimental data from the nickel-based Alloy 617. The study employs uniaxial creep–fatigue test data acquired under various loading histories and compares two distinct neural network-based ODE models. The first model, known as the black-box model, comprehensively describes the strain–stress relationship using a Neural ODE equation. To interpret this black-box model, we apply the Sparse Identification of Nonlinear Dynamical Systems (SINDy) technique, transforming the black-box model into an equation-based model using symbolic regression. The second model, the Neural flow rule model, incorporates Hooke’s Law for the linear elastic component, with the nonlinear part characterized by a Neural ODE. Both models are trained with experimental data to accurately reflect the observed stress–strain behavior. We conduct a detailed comparison with the standard Chaboche model, which includes three back stresses. Our results demonstrate that the neural network-based ODE models precisely capture the experimental creep–fatigue mechanical behavior, exceeding the standard Chaboche model’s accuracy. Furthermore, an interpretable model derived from the black-box neural ODE model through symbolic regression achieves accuracy comparable to the Chaboche model, enhancing its interpretability. The results highlight the potential of neural network-based ODE models to depict complex creep–fatigue behavior, eliminating the necessity for experts to define a specific, material-focused model form.

creep-fatigue

Strong gradient neoclassical transport in the plateau regime

Strong gradient regions in tokamaks such as the pedestal or internal transport barriers are regions of reduced turbulence where neoclassical transport can play a dominant role. In pedestals, gradient lengths comparable to the ion poloidal gyroradius have been measured. Standard neoclassical theory can miss important strong gradient effects in these regions because it assumes that the gradient length scales of density, temperature and potential are larger than the ion poloidal gyroradius. We extend plateau regime neoclassical theory into regions of gradients of the order of the ion poloidal gyroradius to capture strong gradient effects on transport processes in the pedestal and internal transport barriers. The fundamental idea behind our new framework is to keep a scale separation between the orbit widths and the gradient length scales by performing a large aspect ratio expansion. In the plateau regime, strong gradients cause poloidal variation that is in–out as well as up–down asymmetric. We study two different test cases assuming either radial force balance or the absence of turbulence and show that strong gradient effects can enhance or reduce standard neoclassical theory predictions in the plateau regime in strong gradient regions.

fusion plasma

Three Dimensionally Woven Mid-Density Carbon Phenolic (3MDCP) is a Novel Single Piece Ablative TPS for Extreme Entry Environments

Three Dimensionally Woven Mid-Density Carbon Phenolic (3MDCP) is robust, single piece, carbon phenolic ablative thermal protection system under development at NASA Ames Research Center initially for the Mars Sample Return Earth Entry System (MSR EES). The MSR EES requirements drove the need for TPS with no seams, capable of surviving the highest entry conditions for any NASA Earth return capsule with heat fluxes >2000 W/cm2 and pressures >1.5 atmospheres. To produce 3MDCP required development of new weaving infrastructure to enable weaving of preforms large enough to form into a single piece heatshield. It required development of forming techniques to transform a flat woven panel into a sphere cone shape and enhanced infusion processes to support larger scale infusion of resin into the formed preforms. A rigorous performance testing campaign was conducted to develop and validate the materials thermal response model used to determine the required material thickness and to demonstrate the material can survive the extreme entry conditions. The end of the development effort (end of FY26) will result in a TPS at Technical Readiness Level (TRL) 6 and Manufacturing Readiness Level (MRL) 6+ for the MSR EES mission and a mature system ready to support other missions. This poster will provide a snapshot of where 3MDCP is in its development phase.

Ablator

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Crewed Space Vehicle Battery Safety Requirements

This requirements document is applicable to all batteries on crewed spacecraft, including vehicle, payload, and crew equipment batteries. It defines the specific provisions required to design a battery that is safe for ground personnel and crew members to handle and/or operate during all applicable phases of crewed missions, safe for use in the enclosed environment of a crewed space vehicle, and safe for use in launch vehicles, as well as in unpressurized spaces adjacent to the habitable portion of a space vehicle. The required provisions encompass hazard controls, design evaluation, and verification. The extent of the hazard controls and verification required depends on the applicability and credibility of the hazard to the specific battery design and applicable missions under review. Evaluation of the design and verification program results shall be completed prior to certification for flight and ground operations. This requirements document is geared toward the designers of battery systems to be used in crewed vehicles, crew equipment, crew suits, or batteries to be used in crewed vehicle systems and payloads (or experiments). This requirements document also applies to ground handling and testing of flight batteries. Specific design and verification requirements for a battery are dependent upon the battery chemistry, capacity, complexity, charging, environment, and application. The variety of battery chemistries available, combined with the variety of battery-powered applications, results in each battery application having specific, unique requirements pertinent to the specific battery application. However, there are basic requirements for all battery designs and applications, which are listed in section 4. Section 5 includes a description of hazards and controls and also includes requirements.

Jeevarajan, Judith A.

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Ice in Convective Storm Environments: Assessing Impacts of Microphysics on Simulated Reflectivities

Satellite radar retrievals of clouds and precipitation rely on assumptions about the microphysical properties of hydrometeors such as particle size distributions (PSDs) and massdimensional relationships, which have been shown to vary in distinct environments. A deeper understanding of linkages between mass-dimensional relationships, ice crystal shape, and radar reflectivities across cloud and precipitation regimes is necessary for developing new retrievals for upcoming satellite radar missions, including the INvestigation of Convective UpdraftS (INCUS), as well as future missions that will feature space-borne radars observing clouds, convection, and precipitation. This study investigates ice microphysical characteristics through aircraft in-situ and remote sensing observations from two convective events during the Mid-latitude Continental Convective Clouds Experiment (MC3E) in the Southern Great Plains, and tests implications for ice particle habit in forward modeled radar observations. During MC3E, the Ka/Ku- band High Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP) was onboard the NASA ER-2 aircraft, while in-situ measurements were taken onboard the University of North Dakota Citation. In-situ PSDs and particle shape information from optical array probe data are used to forward model radar reflectivities from particle scattering databases and are compared against HIWRAP reflectivities. Various particle combinations can be used to find agreement with HIWRAP observations, and the forward modeled reflectivities were sensitive to particle type. Varying the riming on the aggregate and graupel particles resulted in larger than 10 dB differences in reflectivities. The in-situ and radar observations imply the occurrence of aggregation, size sorting and lofting particles.

Julia A. Shates

Protein Crystal Growth Results From the United States Microgravity Laboratory-1 Mission

Protein crystal growth experiments have been performed by this laboratory on 18 Space Shuttle missions since April, 1985. In addition, a number of microgravity experiments also have been performed and reported by other investigators. These Space Shuttle missions have been used to grow crystals of a variety of proteins using vapor diffusion, liquid diffusion, and temperature-induced crystallization techniques. The United States Microgravity Laboratory - 1 mission (USML-1, June 25 - July 9, 1992) was a Spacelab mission dedicated to experiments involved in materials processing. New protein crystal growth hardware was developed to allow in orbit examination of initial crystal growth results, the knowledge from which was used on subsequent days to prepare new crystal growth experiments. In addition, new seeding hardware and techniques were tested as well as techniques that would prepare crystals for analysis by x-ray diffraction, a capability projected for the planned Space Station. Hardware that was specifically developed for the USML-1 mission will be discussed along with the experimental results from this mission.

L J Delucas

Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN

Characterization of a New Phase and Its Effect on the Work Characteristics of a Near-Stoichiometric Ni30Pt20Ti50 High-Temperature Shape Memory Alloy (HTSMA)

A new phase observed in a nominal Ni 30 Pt 20 Ti 50 (at.%) high temperature shape memory alloy has been characterized using transmission electron microscopy and 3-D atom probe tomography. This phase forms homogenously in the B2 austenite matrix by a nucleation and growth mechanism and results in a concomitant increase in the martensitic transformation temperature of the base alloy. Although the structure of this phase typically contains a high density of faults making characterization difficult, it appears to be trigonal (-3m point group) with a o ~1.28 nm and c o ~1.4 nm. Precipitation of this phase increases the microhardness of the alloy substantially over that of the solution treated and quenched single-phase material. The effect of precipitation strengthening on the work characteristics of the alloy has been explored through load-biased strain-temperature testing in the solution-treated condition and after aging at 500 ºC for times ranging from 1 to 256 hours. Work output was found to increase in the aged alloy as a result of an increase in transformation strain, but was not very sensitive to aging time. The amount of permanent deformation that occurred during thermal cycling under load was small but increased with increasing aging time and stress. Nevertheless, the dimensional stability of the alloy at short aging times (1-4 hours) was still very good making it a potentially useful material for high-temperature actuator applications.

A Garg

Unraveling interphase-driven failure pathways in LiMn0.6Fe0.4PO4/graphite pouch cells

LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.

Chak, Chanmonirath Michael

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

Insights into elevated temperature tensile deformation mechanisms and kink banding in additively manufactured tungsten

Additive manufacturing (AM) potentially enables fabrication and repair of plasma facing components (PFCs) of tungsten. However, deformation mechanisms in AM-fabricated tungsten under service-relevant thermomechanical conditions remain unknown majorly due to challenges in achieving crack-free W. This study reveals the deformation mechanisms operative under tension at 800 °C and 1200 °C in the electron beam melting powder bed fusion (EBM-PBF) fabricated W. Textured columnar grains with mixed <001 >/<111 >|| build-direction were observed. Strong anisotropy in tensile properties persisted across test temperatures, and all specimens exhibited extensive deformation-induced banding phenomena. Grain boundary character analysis of the deformed specimens indicated that these deformation bands were kink bands with tilt grain boundaries prominently present at the band-matrix interface. Interestingly, the material within the kink bands rotated toward higher resolved shear stress, providing insights into the origins of kink band formation in body-centered cubic refractory metals. Intragranular misorientation axis analysis revealed that plasticity was dominated by {110} <111 > slip at 800 °C, whereas additional (213)[11⁢̄1] and (112)[11⁢̄1] slip systems activated at 1200 °C. A dense low-angle boundary networks observed near fractured surface indicated the onset of dynamic recrystallization. Results reveal plasticity governing mechanisms in AM-fabricated W under power plant-relevant conditions, and provide insights into kink band attributes in refractory metals.

Mayes, Riley [ORNL] (ORCID:000900089307010X)

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic