Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

MHD Analysis of Dual-Coolant Lead-Lithium Blanket for Spherical Tokamak Advanced Reactor

The tritium breeding blanket is vital for future fusion power plants, with the Spherical Tokamak Advanced Reactor (STAR) project highlighting the dual-coolant lead-lithium (DCLL) design. The DCLL blanket performs shielding, energy exhaust, and tritium breeding using a lead-lithium alloy , with lithium as the breeder and lead as the neutron multiplier. It also serves as the primary coolant, with helium providing supplemental cooling. Reduced-activation ferritic/martensitic steel is used for the blanket structure. Magnetohydrodynamic (MHD) phenomena influence the liquid metal flow in a magnetic field, affecting heat transfer in the breeder affected by energetic neutrons. Understanding key flow parameters in such conditions is critical for efficient DCLL design. This study uses three-dimensional thermofluid MHD analysis with ANSYS CFX software, modified at Princeton Plasma Physics Laboratory, to simulate high Hartmann flows. The neutronics code MCNP, coupled with plasma equilibrium, provides heat source distribution. In conclusion, we examine electromagnetic interactions in adjacent fluid domains and analyze the magnetic field’s impact on flow distribution in the inboard and outboard blanket layout, using detailed mesh generation for accurate results.

DCLL↗

Geant4 Computing Performance Benchmarking and Monitoring

Performance evaluation and analysis of large scale computing applications is essential for optimal use of resources. As detector simulation is one of the most compute intensive tasks and Geant4 is the simulation toolkit most widely used in contemporary high energy physics (HEP) experiments, it is important to monitor Geant4 through its development cycle for changes in computing performance and to identify problems and opportunities for code improvements. All Geant4 development and public releases are being profiled with a set of applications that utilize different input event samples, physics parameters, and detector configurations. Results from multiple benchmarking runs are compared to previous public and development reference releases to monitor CPU and memory usage. Observed changes are evaluated and correlated with code modifications. Besides the full summary of call stack and memory footprint, a detailed call graph analysis is available to Geant4 developers for further analysis. The set of software tools used in the performance evaluation procedure, both in sequential and multi-threaded modes, include FAST, IgProf and Open|Speedshop. In conclusion, the scalability of the CPU time and memory performance in multi-threaded application is evaluated by measuring event throughput and memory gain as a function of the number of threads for selected event samples.

97 MATHEMATICS AND COMPUTING↗

Cavallo's multiplier for in situ generation of high voltage

Here, a classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.

47 OTHER INSTRUMENTATION↗

Narrow-line Seyfert 1 galaxies in Sloan Digital Sky Survey: a new optical spectroscopic catalogue

ABSTRACT Narrow-line Seyfert 1 (NLSy1) galaxies are an enigmatic class of active galactic nuclei (AGN) that exhibit peculiar multiwavelength properties across the electromagnetic spectrum. For example, these sources have allowed us to explore the innermost regions of the central engine of AGN using X-ray observations and have also provided clues about the origin of relativistic jets considering radio and gamma-ray bands. Keeping in mind the ongoing and upcoming wide-field, multifrequency sky surveys, we present a new catalogue of NLSy1 galaxies. This was done by carrying out a detailed decomposition of >2 million optical spectra of quasars and galaxies from the Sloan Digital Sky Survey Data Release 17 (SDSS-DR17) using the publicly available software ‘Bayesian AGN Decomposition Analysis for SDSS Spectra’. The catalogue contains 22656 NLSy1 galaxies which is more than twice the size of the previously identified NLSy1s based on SDSS-DR12. As a corollary, we also release a new catalogue of 52273 broad-line Seyfert 1 (BLSy1) galaxies. The estimated optical spectral parameters and derived quantities confirm the previously known finding of NLSy1 galaxies being AGN powered by highly accreting, low-mass black holes. We conclude that this enlarged sample of NLSy1 and BLSy1 galaxies will enable us to explore the low-luminosity end of the AGN population by effectively utilizing the sensitive, high-quality observations delivered by ongoing/upcoming wide-field sky surveys. The catalogue has been made public at https://www.ucm.es/blazars/seyfert.

Paliya, Vaidehi S. (ORCID:0000000177745308)↗

DSPS: Differentiable stellar population synthesis

ABSTRACT Models of stellar population synthesis (SPS) are the fundamental tool that relates the physical properties of a galaxy to its spectral energy distribution (SED). In this paper, we present DSPS: a python package for SPS. All of the functionality in DSPS is implemented natively in the JAX library for automatic differentiation, and so our predictions for galaxy photometry are fully differentiable, and directly inherit the performance benefits of JAX, including portability onto GPUs. DSPS also implements several novel features, such as i) a flexible empirical model for stellar metallicity that incorporates correlations with stellar age, ii) support for the Diffstar model that provides a physically-motivated connection between the star formation history of a galaxy (SFH) and the mass assembly of its underlying dark matter halo. We detail a set of theoretical techniques for using autodiff to calculate gradients of predictions for galaxy SEDs with respect to SPS parameters that control a range of physical effects, including SFH, stellar metallicity, nebular emission, and dust attenuation. When forward modelling the colours of a synthetic galaxy population, we find that DSPS can provide a factor of 5 speed-up over standard SPS codes on a CPU, and a factor of 300-400 on a modern GPU. When coupled with gradient-based techniques for optimization and inference, DSPS makes it practical to conduct expansive likelihood analyses of simulation-based models of the galaxy–halo connection that fully forward model galaxy spectra and photometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Periodicity significance testing with null-signal templates: reassessment of PTF’s SMBH binary candidates

Periodograms are widely employed for identifying periodicity in time series data, yet they often struggle to accurately quantify the statistical significance of detected periodic signals when the data complexity precludes reliable simulations. We develop a data-driven approach to address this challenge by introducing a null-signal template (NST). The NST is created by carefully randomizing the period of each cycle in the periodogram template, rendering it non-periodic. It has the same frequentist properties as a periodic signal template, and we show with simulations that the distribution of false positives is the same as with the original periodic template, regardless of the underlying data. Thus, performing a periodicity search with the NST acts as an effective simulation of the null (no-signal) hypothesis, without having to simulate the noise properties of the data. We apply the NST method to the supermassive black hole binaries (SMBHB) search in the Palomar Transient Factory (PTF), where Charisi et al. had previously proposed 33 high signal-to-noise candidates utilizing simulations to quantify their significance. Our approach reveals that these simulations do not capture the complexity of the real data. There are no statistically significant periodic signal detections above the non-periodic background. To improve the search sensitivity, we introduce a Gaussian quadrature based algorithm for the Bayes Factor with correlated noise as a test statistic. We show with simulations that this improves sensitivity to true signals by more than an order of magnitude. However, the Bayes Factor approach also results in no statistically significant detections in the PTF data.

79 ASTRONOMY AND ASTROPHYSICS↗

Estradiol associations with brain functional connectivity in postmenopausal women

Abstract Objective Previous studies have found that estrogens play a role in functional connectivity in the brain; however, little research has been done regarding how estradiol is associated with functional connectivity in postmenopausal women. The purpose of this study was to examine the relationship between estradiol and functional connectivity in postmenopausal women. Methods Structural and blood oxygenation level–dependent resting-state magnetic resonance imaging scans of 88 cognitively healthy postmenopausal individuals were obtained along with blood samples collected the same day as the magnetic resonance imaging to assess hormone levels. We generated connectivity values in CONN toolbox version 20.b, an SPM-based software. Results A regression analysis was run using estradiol level and regions of interest (ROI), including the hippocampus, parahippocampus, dorsolateral prefrontal cortex, and precuneus. Estradiol level was found to enhance parahippocampal gyrus anterior division left functional connectivity during ROI-to-ROI regression analysis. Estradiol enhanced functional connectivity between the parahippocampal gyrus anterior division left and the precuneus as well as the parahippocampal gyrus anterior division left and parahippocampal gyrus posterior division right. An exploratory analysis showed that years since the final menstrual period was related to enhanced connectivity between regions within the frontoparietal network. Conclusions These results illustrated the relationship between estradiol level and functional connectivity in postmenopausal women. They have implications for understanding how the functioning of the brain changes for individuals after menopause that may eventually lead to changes in cognition and behavior in older ages.

Obstetrics & Gynecology↗

Comparing event generator predictions and ab initio calculations of ν- 12 C neutral-current quasielastic scattering at 1 GeV

The measurement of neutrino oscillations and exotic physics searches are important parts of the physics program in the near future, with new state-of-the-art experiments planned within the next decade. Future and modern experiments in these fields will make use of nuclear targets. Event generators (EGs) are software used in the analysis of neutrino oscillation experiments. EGs are used to predict kinematic observables for a range of neutrino energies. These simulations make use of simple models of nucleon dynamics. As such, they may fail to capture features of more rigorous theoretical calculations. This work compares EG performance to nuclear theory calculations by comparing observables generated in the two frameworks. We provide a common set of definitions between theory and experiment and assess the adequacy of the implementation of two nuclear physics models in EG simulations. Neutral-current quasielastic (NCQE) scattering events for neutrinos and antineutrinos on a 12 C target are simulated with a specific EG, NEUT, used by the T2K experiment for its analysis. The simulated cross sections are compared to analytic calculations from nuclear theory within the factorization scheme. We compare the NEUT implementation of two different models on nuclear spectral functions: the relativistic Fermi gas (RFG) and the correlated basis spectral function (CBF) to analytic calculations of the same models in the factorization scheme. For both nuclear physics models, we compare the appearance of features in the distributions relevant to experimental analyses. The peak of the cross section dσ/(dΩ dω) is consistent in energy transfer, ω, for RFG and CBF simulations. Qualitatively, the shape of the simulated distribution is similar to the one obtained through theory calculations; however, there are some discrepancies between the theory calculations and the NEUT simulation. While the EG simulations and analytic calculations with the same model of nuclear dynamics show similar overall features, there are still differences between the two. These results demonstrate the importance of benchmarking EGs so their nuclear physics implementations can be improved for the analysis of future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new synchrotron rapid-scanning X-ray fluorescence (SRS-XRF) imaging station at SSRL beamline 6-2

This paper describes a new large-range rapid-scan X-ray fluorescence (XRF) imaging station at beamline 6-2 at the Stanford Synchrotron Radiation Lightsource at SLAC National Accelerator Laboratory. This station uses a continuous rapid-scan system with a scan range of 1000 × 600 mm and a load capacity of up to 25 kg, capable of 25–100 µm resolution elemental XRF mapping and X-ray absorption spectroscopy (XAS) of a wide range of objects. XRF is measured using a four-element Hitachi Vortex ME4 silicon drift detector coupled to a Quantum Detectors Xspress3 multi-channel analyzer system. A custom system allows the X-ray spot size to be changed quickly and easily via pinholes ranging from 25 to 100 µm, and the use of a poly-capillary or axially symmetric achromatic optic may achieve a <10 µm resolution in the future. The instrument is located at wiggler beamline 6-2 which has an energy range of 2.1–17 keV, creating K emission for elements up to strontium, and L or M emission for all other elements. XAS can also be performed at selected sample positions within the same experiment, allowing for a more detailed chemical characterization of the elements of interest. Furthermore, sparse excitation energy XRF imaging can be performed over a wide range of incident X-ray energies. User friendliness has been emphasized in all stages of the experiment, including versatile sample mounts, He purged chambers for low- Z analyses, and intuitive visualization hardware and software. The station provides analysis capabilities for a wide range of materials and research fields including biological, chemical, environmental and materials science, paleontology, geology and cultural heritage.

47 OTHER INSTRUMENTATION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Dynamic Adaptable Asynchronous Progress Model for MPI RMA Multiphase Applications

Casper is a process-based asynchronous progress model for MPI one-sided communication on multi-and many-core architectures. The one-sided communication is not truly one-sided in most MPI implementations: the target process still relies on software progress to complete incoming operations. Casper allows the user to specify an arbitrary number of cores dedicated to background ghost processes and transparently redirects the RMA operations to ghost processes by utilizing the PMPI redirection and MPI-3 shared-memory technologies. Although Casper benefits applications that suffer from lack of asynchronous progress, the operation redirection design might not support complex multiphase applications effectively, which often involve dynamically changing communication density and computing workloads. In this paper, we present an adaptive mechanism in Casper to address the limitation of static asynchronous progress in multiphase applications. For this we exploit two adaptive strategies, a user-guided strategy and a fully transparent and automatic strategy based on self-profiling and prediction, to dynamically reconfigure the asynchronous progress in Casper according to real-time performance characteristics during multiphase execution. We evaluate the adaptive approaches in both microbenchmarks and a real quantum chemistry application suite, NWChem, on the Cray XC30 supercomputer and an Intel Omni-Path cluster.

97 MATHEMATICS AND COMPUTING↗

Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-122: Dosimetric Comparison Between Cone, HDMLC and MicroMLC for the Treatment of Trigeminal Neuralgia

Purpose: The purpose of this work was to evaluate the dosimetric characteristics of three collimation systems, 5mm circular cone (Brainlab) and square fields of 5mm with HDMLC (Varian) and microMLC Moduleaf, Siemens) for trigeminal neuralgia treatment. Methods: A TPS Iplan v4.5 BrainLAB was used to do treatment plans for each collimations system in a square solid water phantom with isocenter at 5cm depth. Single field and treatment plan including 11 arcs with fix field and 100° gantry range was made for each collimation systems. EBT3 films were positioned at isocenter in a coronal plane to measured dose distribution for all geometries. Films were digitized with a Vidar DosimetryPro Red scanner with a resolution of 89dpi and RIT113v6.1 software was used for analysis. Penumbra region (80%–20%), FWHM and dose percentage at 5mm and 10mm from CAX were determined. All profiles were normalized at CAX. Results: For single beam the penumbra (FWHM) was 1.5mm (5.3mm) for the cone, 1.9mm (5.5mm) for HDMLC and 1.8mm (5.4mm) for the microMLC. Dose percentage at 5mm was 6.9% for cone, 12.5% for HDMLC and 8.7% for the microMLC. For treatment plan the penumbra (FWHM) was 2.58mm (5.47mm) for the cone, 2.8mm (5.84mm) for HDMLC and 2.58mm (6.09mm) for the microMLC. Dose perecentage at 5mm was 13.1% for cone, 16.1% for HDMLC, 15.2% for the microMLC. Conclusion: The cone has a dose falloff larger than the microMLC and HDMLC, by its reduced penumbra, this translates into better protection of surrounding healthy tissue, however, the microMLC and HDMLC have similar accuracy to cone.

60 APPLIED LIFE SCIENCES↗

SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conducted in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.

60 APPLIED LIFE SCIENCES↗

SU-E-T-49: A Multi-Institutional Study of Independent Dose Verification for IMRT

Purpose: AAPM TG114 does not cover the independent verification for IMRT. We conducted a study of independent dose verification for IMRT in seven institutes to show the feasibility. Methods: 384 IMRT plans in the sites of prostate and head and neck (HN) were collected from the institutes, where the planning was performed using Eclipse and Pinnacle3 with the two techniques of step and shoot (S&S) and sliding window (SW). All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. An ion-chamber measurement in a water-equivalent slab phantom was performed to compare the doses computed using the TPS and an independent dose verification program. Additionally, the agreement in dose computed in patient CT images between using the TPS and using the SMU was assessed. The dose of the composite beams in the plan was evaluated. Results: The agreement between the measurement and the SMU were −2.3±1.9 % and −5.6±3.6 % for prostate and HN sites, respectively. The agreement between the TPSs and the SMU were −2.1±1.9 % and −3.0±3.7 for prostate and HN sites, respectively. There was a negative systematic difference with similar standard deviation and the difference was larger in the HN site. The S&S technique showed a statistically significant difference between the SW. Because the Clarkson-based method in the independent program underestimated (cannot consider) the dose under the MLC. Conclusion: The accuracy would be improved when the Clarkson-based algorithm should be modified for IMRT and the tolerance level would be within 5%.

60 APPLIED LIFE SCIENCES↗

SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencil Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.

60 APPLIED LIFE SCIENCES↗

SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT

Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

YADAS, Version 0

YADAS is a software system for statistical analysis using Markov chain Monte Carlo (MCMC). As such, it performs Monte Carlo integration of probability distributions and generates estimates of unknown quantities based on data and expert opinion if available. Its architecture makes it extensible enough to be helpful in the analysis of any statistical model, so it is particularly useful for statistic researchers. YADAS features a versatile scheme for defining models, and another versatile scheme for defining sampling algorithms that includes a default starting place for most analyses.

Graves, Todd↗