Search NASA⌕ Search

SEARCH · Search NASA

Results for “Avoidance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Pseudosmooth tribrid inflation in SU(5)

A realistic tribrid model of sneutrino inflation is constructed in an R-symmetric SU(5) grand unified theory (GUT). To avoid the monopole problem, a pseudosmooth inflationary trajectory is generated with the help of an additional Z 5 symmetry which is broken during and after inflation. The predictions of inflationary parameters are made at the central value of the scalar spectral index, n s =0.968. The largest possible value of the tensor to scalar ratio, r ≲ 0.0027, is obtained with sub-Planckian field values (≲m P ). A successful realization of reheating and leptogenesis is achieved by avoiding the gravitino problem with a reheat temperature as low as 10 6 GeV. The predicted range of the gauge symmetry breaking scale, 5 × 10 16 ≲ M/GeV ≲ 5 × 10 17 , turns out to be somewhat larger than the typical GUT scale. Finally, with additional vector-like families, a successful gauge coupling unification is achieved by avoiding the no-go theorem related to R-symmetric SU(5) GUT.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Co-benefits of China’s climate policy for air quality and human health in China and transboundary regions in 2030

Abstract Climate policies targeting CO 2 emissions from fossil fuels can simultaneously reduce emissions of air pollutants and their precursors, thus mitigating air pollution and associated health impacts. Previous work has examined co-benefits of climate policy from reducing PM 2.5 in rapidly-developing countries such as China, but have not examined co-benefits from ozone and its transboundary impact for both PM 2.5 and ozone. Here, we compare the air quality and health co-benefits of China’s climate policy on both PM 2.5 and ozone in China to their co-benefits in three downwind and populous countries (South Korea, Japan and the United States) using a coupled modeling framework. In a policy scenario consistent with China’s pledge to peak CO 2 emissions in approximately 2030, avoided premature deaths from ozone reductions are 54 300 (95% confidence interval: 37 100–71 000) in China in 2030, nearly 60% of those from PM 2.5 . Total avoided premature deaths in South Korea, Japan, and the US are 1200 (900–1600), 3500 (2800–4300), and 1900 (1400–2500), respectively. Total avoided deaths in South Korea and Japan are dominated by reductions in PM 2.5 -related mortality, but ozone plays a more important role in the US. Similar to co-benefits for PM 2.5 in China, co-benefits of China’s policy for ozone and for both pollutants in those downwind countries also rise with increasing policy stringency.

54 ENVIRONMENTAL SCIENCES↗

Three approaches for the classification of protoneutron star oscillation modes

ABSTRACT The future detection of gravitational waves (GWs) from a Galactic core-collapse supernova will provide information on the physics inside protoneutron stars (PNS). In this work, we apply three different classification methods for the PNS non-radial oscillation modes: Cowling classification, Generalized Cowling Nomenclature (GCN), and a classification based on modal properties (CBMP). Using PNS models from 3D simulations of core-collapse supernovae, we find that in the early stages of the PNS evolution, typically 0.4 s after the bounce, the Cowling classification is inconsistent, but the GCN and the CBMP provide complementary information that helps to understand the evolution of the modes. In the GCN, we note several avoided crossings as the mode frequencies evolve at early times, while the CBMP tracks the modes across the avoided crossings. We verify that the strongest emission of GWs by the PNS corresponds to the f mode in the GCN, indicating that the mode trapping region alternates between the core and the envelope at each avoided crossing. At later times, approximately 0.4 s after the bounce, the three classification methods present a similar description of the mode spectrum. We use our results to test universal relations for the PNS modes according to their classification and find that the behaviour of the universal relations for f and p modes is remarkably simple in the CBMP.

Astronomy & Astrophysics↗

A heuristic classification of woody plants based on contrasting shade and drought strategies

Woody plants vary in their adaptations to drought and shade. For a better prediction of vegetation responses to drought and shade within dynamic global vegetation models, it is critical to group species into functional types with similar adaptations. One of the key challenges is that the adaptations are generally determined by a large number of plant traits that may not be available for a large number of species. In this study, we present two heuristic woody plant groups that were separated using cluster analysis in a three-dimensional trait–environment space based on three key metrics for each species: mean xylem embolism resistance, shade tolerance and habitat aridity. The two heuristic groups separate these species into tolerators and avoiders. Furthermore, the tolerators either rely on their high embolism resistance to tolerate drought in arid habitats (e.g., Juniperus and Prunus ) or rely on high shade tolerance to withstand shaded conditions in wet habitats (e.g., Picea , Abies and Acer ). In contrast, all avoiders have low embolism resistance and low shade tolerance. In arid habitats, avoiders tend to minimize catastrophic embolism (e.g., most Pinus species) while in wet habitats, they may survive despite low shade tolerance (e.g., Betula , Populus , Alnus and Salix ). Because our approach links traits to the environmental conditions, we expect it could be a promising framework for predicting changes in species composition, and therefore ecosystem function, under changing environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Stochastic noise can be helpful for variational quantum algorithms

Saddle points constitute a crucial challenge for first-order gradient descent algorithms. In notions of classical machine learning, they are avoided, for example, by means of stochastic gradient descent methods. In this work, we provide evidence that the saddle-points problem can be naturally avoided in variational quantum algorithms by exploiting the presence of stochasticity. We prove convergence guarantees and present practical examples in numerical simulations and on quantum hardware. We argue that the natural stochasticity of variational algorithms can be beneficial for avoiding strict saddle points, i.e., those saddle points with at least one negative Hessian eigenvalue. This insight that some levels of shot noise could help is expected to add a new perspective to notions of near-term variational quantum algorithms. Published by the American Physical Society 2025

Liu, Junyu↗

Observation of the dynamics leading to a conical intersection in dissociative electron attachment to water

Following prior work on the lower-energy resonances, we apply techniques of momentum imaging and ab initio scattering calculations to the process of dissociative electron attachment to water via the highest-energy {sup 2}B{sub 2} resonance. We focus on the H{sup -} anion fragment, which is produced via dynamics passing through and avoiding the conical intersection with the lower A{sub 1} state, leading to OH ({sup 2}{Pi}) and OH ({sup 2}{Sigma}), respectively. The momentum imaging technique, when combined with theoretical calculations on the attachment amplitude and dissociation dynamics, demonstrates that the angular distributions provide a signature of the location of the conical intersection in the space of nuclear configurations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of Negligible Creep Criteria to Candidate Materials for HTGR Pressure Vessels

Two of the proposed High Temperature Gas Reactors (HTGRs) under consideration for a demonstration plant have the design object of avoiding creep effects in the reactor pressure vessel (RPV) during normal operation. This work addresses the criteria for negligible creep in Subsection NH, Division 1 of the ASME B&PV (Boiler and Pressure Vessel) Code, Section III, other international design codes and some currently suggested criteria modifications and their impact on permissible operating temperatures for various reactor pressure vessel materials. The goal of negligible creep could have different interpretations depending upon what failure modes are considered and associated criteria for avoiding the effects of creep. It is shown that for the materials of this study, consideration of localized damage due to cycling of peak stresses results in a lower temperature for negligible creep than consideration of the temperature at which the allowable stress is governed by creep properties. In assessing the effect of localized cyclic stresses it is also shown that consideration of cyclic softening is an important effect that results in a higher estimated temperature for the onset of significant creep effects than would be the case if the material were cyclically hardening. There are other considerations for the selection of vessel material besides avoiding creep effects. Of interest for this review are (1) the material s allowable stress level and impact on wall thickness (the goal being to minimize required wall thickness) and (2) ASME Code approval (inclusion as a permitted material in the relevant Section and Subsection of interest) to expedite regulatory review and approval. The application of negligible creep criteria to two of the candidate materials, SA533 and Mod 9Cr-1Mo (also referred to as Grade 91), and to a potential alternate, normalized and tempered 2 Cr-1Mo, is illustrated and the relative advantages and disadvantages of the materials are discussed.

Jetter, Robert I↗

The Impact of Material and Design Criteria on the Assessment of Negligible Creep

Two of the proposed High Temperature Gas Reactors (HTGRs) under consideration for a demonstration plant have the design object of avoiding creep effects during normal operation. The goal of negligible creep could have different interpretations depending upon what failure modes are considered and associated criteria for avoiding the effects of creep. This work addresses the criteria for negligible creep in Subsection NH of Section III of the ASME B&PV Code, other international design codes and some currently suggested criteria modifications and their impact on permissible operating temperatures for various reactor pressure vessel materials. There are a number of other considerations for the selection of vessel material besides avoiding creep effects. Of particular interest for this review are (1) the material s allowable stress level and impact on wall thickness (the goal being to minimize required wall thickness) and (2) ASME Code approval (inclusion as a permitted material in the relevant Section and Subsection of interest) to expedite regulatory review and approval. The application of negligible creep criteria to two of the candidate materials, SA533 and Mod 9Cr-1Mo, and to a potential alternate, normalized and tempered 2 Cr-1Mo, are illustrated and the relative advantages and disadvantages are discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

NPIP: A skew line needle configuration optimization system for HDR brachytherapy

Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, {delta}. The candidate needle set consisted of 5000 needles, and a range of {delta} values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of {delta} values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer needles than the current HDR brachytherapy workflow. Combined with robot assisted brachytherapy, this system has the potential to reduce side effects associated with treatment. A physical trial should be done to test the implant feasibility of NPIP needle configurations.

60 APPLIED LIFE SCIENCES↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-581: A Comparative Study of Standard IMRT and VMAT Planning Techniques for Unilateral and Bilateral Head and Neck Irradiation

Purpose: To compare dosimetric properties and monitor units (MU) of IMRT plans with several VMAT head and neck (H and N) plans. Methods: Seventeen unilateral H and N (UHN) and five bilateral H and N (BHN) patients initially treated with IMRT were replanned with VMAT. Several arc arrangements were studied for each patient: 1)for UHN, two 360° arcs, two 260° arcs, two 210° arcs, two 360° arcs with contralateral avoidance sectors, and 2)for BHN, two 360° arcs, two 360° arcs with bilateral avoidance sectors, two 360° arcs with bilateral avoidance sectors and a third arc limited to the upper neck. Optimization constraints were adjusted for each patient and plan. All plans were normalized to achieve the same highest-dose PTV coverage. Percent differences (IMRT-VMAT)/VMAT in MU, dose homogeneity (HI=maximum point dose/prescription dose), and organ-at-risk (OAR) metrics are reported and statistical significance evaluated (p<0.05; paired Student t-test). Results: Average reduction in MU with VMAT was 28% for UHN (p<0.0001) and 63% for BHN (p<0.0001). Average HI for UHN IMRT and 360° arc VMAT plans was 1.08 and for plans with arcs <360° average HI=1.10. Average HI for BHN IMRT was 1.07, for three-arc VMAT 1.08, and for two-arc VMAT 1.11. For UHN, two 210° arcs achieved lower contralateral parotid max (−2.6 Gy, p<0.02) and mean (−1.2 Gy, p=0.06) dose. For BHN two-arc plans, contralateral parotid mean dose increased (3.3 Gy, p<0.04) and larynx max dose increased (2.9 Gy, p<0.02) with no change in larynx mean dose. Conclusion: For UHN, 360degree arc VMAT consistently produced plans dosimetrically comparable to IMRT with the benefit of lower MU. VMAT with arcs <360degrees produced plans inferior to IMRT in dose homogeneity and without significantly improved OAR sparing. For BHN, three-arc plans were dosimetrically comparable to IMRT with lower MU, while two-arc plans were inferior to IMRT in HI and OAR dose. Research supported in part by a Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-01: Effect of Iodine Contrast Agent Concentration On Cerebrovascular Dose for Synchrotron Radiation Microangiography Based On a Simple Mouse Head Model and a Voxel Mouse Head Phantom

Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results: The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatment isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.

60 APPLIED LIFE SCIENCES↗

Impact of Electrolyte Solvent on Li 4 Ti 5 O 12 /LiNi 0.90 Mn 0.05 Co 0.05 O 2 Battery Performance for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) systems require dedicated development of battery materials that target long cycle life and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) and LiNi 0.9 Mn 0.05 Co 0.05 O 2 (NMC90-5-5) shows promise to achieve targets for BTMS applications; however, minimal literature is available that discusses electrolyte solvent selection for this pairing. This study explores the role of electrolyte solvent on cycle life in LTO/NMC90-5-5 batteries. Four model electrolytes are evaluated; the baseline, Gen2, is compared with 1M LiPF 6 added to each of three separate solvents: ethylene carbonate (EC), ethyl methyl carbonate (EMC), and fluoroethylene carbonate (FEC). An additional consideration is that NMC90-5-5 undergoes an H2→H3 phase transition that allows for a significant increase to capacity; however, it’s unclear how this phase transition impacts electrolyte stability and cycle life. Therefore, the phase transition is avoided or accessed by cycling to 2.6V or 2.7V, respectively. The cells with Gen2, cycled to 2.6V, show the highest capacity retention due to EC passivating the LTO, EMC improving stability at the NMC90-5-5, and avoiding increased degradation from the 2.7V protocol. Despite having high initial reactivity that causes Li-depletion, FEC was the only solvent to avoid increased degradation when moving to the higher termination voltage.

25 ENERGY STORAGE↗

Can we use antipredator behavior theory to predict wildlife responses to high-speed vehicles?

Animals seem to rely on antipredator behavior to avoid vehicle collisions. There is an extensive body of antipredator behavior theory that have been used to predict the distance/time animals should escape from predators. These models have also been used to guide empirical research on escape behavior from vehicles. However, little is known as to whether antipredator behavior models are appropriate to apply to an approaching high-speed vehicle scenario. We addressed this gap by (a) providing an overview of the main hypotheses and predictions of different antipredator behavior models via a literature review, (b) exploring whether these models can generate quantitative predictions on escape distance when parameterized with empirical data from the literature, and (c) evaluating their sensitivity to vehicle approach speed using a simulation approach wherein we assessed model performance based on changes in effect size with variations in the slope of the flight initiation distance (FID) vs. approach speed relationship. The slope of the FID vs. approach speed relationship was then related back to three different behavioral rules animals may rely on to avoid approaching threats: the spatial, temporal, or delayed margin of safety. We used literature on birds for goals (b) and (c). Our review considered the following eight models: the economic escape model, Blumstein’s economic escape model, the optimal escape model, the perceptual limit hypothesis, the visual cue model, the flush early and avoid the rush (FEAR) hypothesis, the looming stimulus hypothesis, and the Bayesian model of escape behavior. We were able to generate quantitative predictions about escape distance with the last five models. However, we were only able to assess sensitivity to vehicle approach speed for the last three models. The FEAR hypothesis is most sensitive to high-speed vehicles when the species follows the spatial (FID remains constant as speed increases) and the temporal margin of safety (FID increases with an increase in speed) rules of escape. The looming stimulus effect hypothesis reached small to intermediate levels of sensitivity to high-speed vehicles when a species follows the delayed margin of safety (FID decreases with an increase in speed). The Bayesian optimal escape model reached intermediate levels of sensitivity to approach speed across all escape rules (spatial, temporal, delayed margins of safety) but only for larger (> 1 kg) species, but was not sensitive to speed for smaller species. Overall, no single antipredator behavior model could characterize all different types of escape responses relative to vehicle approach speed but some models showed some levels of sensitivity for certain rules of escape behavior. We derive some applied applications of our findings by suggesting the estimation of critical vehicle approach speeds for managing populations that are especially susceptible to road mortality. Overall, we recommend that new escape behavior models specifically tailored to high-speeds vehicles should be developed to better predict quantitatively the responses of animals to an increase in the frequency of cars, airplanes, drones, etc. they will face in the next decade.

54 ENVIRONMENTAL SCIENCES↗

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products

ENERGY STAR is a voluntary energy efficiency labeling program operated jointly by the Environmental Protection Agency (US EPA) and the U.S. Department of Energy (US DOE), designed to identify and promote energy-efficient products, buildings and practices. Since the program inception in 1992, ENERGY STAR has become a leading international brand for energy efficient products, and currently labels more than thirty products, spanning office equipment, heating, cooling and ventilation equipment, commercial and residential lighting, home electronics, and major appliances. ENERGY STAR's central role in the development of regional, national and international energy programs necessitates an open process whereby its program achievements to date as well as projected future savings are shared with stakeholders. This report presents savings estimates from the use ENERGY STAR labeled products. We present estimates of energy, dollar, and carbon savings achieved by the program in the year 2009, annual forecasts for 2010 and 2011, and cumulative savings estimates for the period 1993 through 2009 and cumulative forecasts for the period 2010 through 2015. Through 2009 the program saved 9.5 Quads of primary energy and avoided the equivalent of 170 million metric tons carbon (MMTC). The forecast for the period 2009-2015 is 11.5 Quads or primary energy saved and 202 MMTC emissions avoided. The sensitivity analysis bounds the best estimate of carbon avoided between 110 MMTC and 231 MMTC (1993 to 2009) and between 130 MMTC and 285 MMTC (2010 to 2015).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for the Standard Model Higgs boson produced in association with a W Boson in the isolated-track charged-lepton channel using the Collider Detector at Fermilab

The Higgs boson is the only elementary particle predicted by the Standard Model (SM) that has not yet been observed experimentally. If it exists, it explains the spontaneous electroweak symmetry breaking and the origin of mass for gauge bosons and fermions. We test the validity of the SM by performing a search for the associated production of a Higgs boson and a W boson in the channel where the Higgs boson decays to a bottom-antibottom quark pair and the W boson decays to a charged lepton and a neutrino (the WH channel). We study a dataset of proton-antiproton collisions at a centre-of-mass energy √s = 1.96 TeV provided by the Tevatron accelerator, corresponding to an integrated luminosity of 5.7 fb -1 , and recorded using the Collider Detector at Fermilab (CDF).We select events consistent with the signature of exactly one charged lepton (electron or muon), missing transverse energy due to the undetected neutrino (MET) and two collimated streams of particles (jets), at least one of which is required to be identified as originating from a bottom quark. We improve the discrimination of Higgs signal from backgrounds through the use of an artificial neural network. Using a Bayesian statistical inference approach, we set for each hypothetical Higgs boson mass in the range 100-150 GeV/c 2 with 5 GeV/c 2 increments a 95% credibility level (CL) upper limit on the ratio between the Higgs production cross section times branching fraction and the SM prediction. Our main original contributions are the addition of a novel charged lepton reconstruction algorithm with looser requirements (ISOTRK) with respect the electron or muon tight criteria (TIGHT), as well as the introduction of a novel trigger-combination method that allows to maximize the event yield while avoiding trigger correlations and that is used for the ISOTRK category. The ISOTRK candidate is a high-transverse-momentum good-quality track isolated from other activity in the tracking system and not required to match a calorimeter cluster, as for a tight electron candidate, or an energy deposit in the muon detector, as for a tight muon candidate. The ISOTRK category recovers real charged leptons that otherwise would be lost in the non-instrumented regions of the detector. This allows the reconstruction of more W boson candidates, which in turn increases the number of reconstructed WH signal candidate events, and therefore improves the sensitivity of the WH search. For the TIGHT charged lepton categories, we employ charged-lepton-dedicated triggers to improve the rate of WH signal acceptance during data taking. Since there is no ISOTRK-dedicated trigger at CDF, for the ISOTRK charged lepton category we employ three MET-plus-jets-based triggers. For each trigger we first identify the jet selection where the trigger efficiency is flat with respect to jet information (transverse energy and direction of motion in the transverse plane for the two jets in the event) and then we parametrize the trigger efficiency as a function of trigger MET. On an event-by-event basis, for each trigger we compute a trigger efficiency as a function of trigger parametrization, trigger MET, jet information, trigger prescale and information about whether the trigger is defined or not. For the ISOTRK category we combine the three triggers using a novel method, which allows the combination of any number of triggers in order to maximize the event yield while avoiding trigger correlations. On an event-by-event basis, only the trigger with the largest efficiency is used. By avoiding a logical 'OR' between triggers, the loss in the yield of events accepted by the trigger combination is compensated by a smaller and easier-to-compute corresponding systematic uncertainty. The addition of the ISOTRK charged lepton category to the TIGHT category produces an increase of 33% in the WH signal yield and a decrease of 15.5% to 19.0% in the median expected 95% CL cross-section upper limits across the entire studied Higgs mass interval. The improvement in analysis sensitivity is smaller than the improvement in signal yield because the ISOTRK category has a smaller signal over background ratio than the TIGHT category, due to the looser ISOTRK reconstruction criteria. The observed (median expected) 95% CL SM Higgs upper limits on cross section times branching ratio vary between 2.39 x SM (2.73 x SM) for a Higgs mass of 100 GeV/c 2 to 31.1 x SM (31.2 x SM) for a Higgs mass of 150 GeV/c 2 , while the value for a 115 GeV/c 2 Higgs boson is that of 5.08 x SM (3.79 x SM). The novel trigger combination method is already in use by several CDF analyses. It is applicable to any analysis that uses triggers based on MET and jets, such as supersymmetry searches at the ATLAS and CMS experiments at the Large Hadron Collider. In its most general form, the method can be used by any analysis that combines any number of different triggers.

43 PARTICLE ACCELERATORS↗