Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Using a polarized maser to detect high-frequency relic gravitational waves

A GHz maser beam with Gaussian-type distribution passing through a homogenous static magnetic field can be used to detect gravitational waves (GWs) with the same frequency. The presence of GWs will perturb the electromagnetic fields, giving rise to perturbed photon fluxes. After being reflected by a fractal membrane, the perturbed photons suffer little decay and can be measured by a microwave receiver. This idea has been explored to a certain extent as a method for very high-frequency gravitational waves. In this paper, we examine and develop this method more extensively, and confront the possible detection with the predicted signal of relic gravitational waves (RGWs). A maser beam with high linear polarization is used to reduce the background photon fluxes in the detecting direction as the main noise. As a key factor of applicability of this method, we give a preliminary estimation of the sensitivity of a sample detector limited by thermal noise using currently common technology. The minimal detectable amplitude of GWs is found to be h{sub min}{approx}10{sup -30}. Comparing with the known spectrum of the RGWs in the accelerating universe for {beta}=-1.9, there is still roughly a gap of 4{approx}5 orders. However, possible improvements on the detector can further narrow down the gap and make it a feasible method to detect high-frequency RGWs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field-size effect of physical doses in carbon-ion scanning using range shifter plates

A field-size effect of physical doses was studied in scanning irradiation with carbon ions. For the target volumes of 60x60x80, 40x40x80, and 20x20x80 mm{sup 3}, the doses along the beam axis within the spread-out Bragg peaks reduced to 99.4%, 98.2%, and 96.0% of the dose for the target of 80x80x80 mm{sup 3}, respectively. The present study revealed that the observed reductions can be compensated for by adopting the three-Gaussian form of lateral dose distributions for the pencil beam model used in the treatment planning system. The parameters describing the form were determined through the irradiation experiments making flat concentric squared frames with a scanned carbon beam. Since utilizing the three-Gaussian model in the dose optimization loop is at present time consuming, the correction for the field-size effect should be implemented as a ''predicted-dose scaling factor.'' The validity of this correction method was confirmed through the irradiation of a target of 20x20x80 mm{sup 3}.

61 RADIATION PROTECTION AND DOSIMETRY↗

A critical look at the prediction of the temperature field around a laser-induced melt pool on metallic substrates

The study of microstructure evolution in additive manufacturing of metals would be aided by knowing the thermal history. Since temperature measurements beneath the surface are difficult, estimates are obtained from computational thermo-mechanical models calibrated against traces left in the sample revealed after etching, such as the trace of the melt pool boundary. Here we examine the question of how reliable thermal histories computed from a model that reproduces the melt pool trace are. To this end, we perform experiments in which one of two different laser beams moves with constant velocity and power over a substrate of 17-4PH SS or Ti-6Al-4V, with low enough power to avoid generating a keyhole. We find that thermal histories appear to be reliably computed provided that (a) the power density distribution of the laser beam over the substrate is well characterized, and (b) convective heat transport effects are accounted for. Poor control of the laser beam leads to potentially multiple three-dimensional melt pool shapes compatible with the melt pool trace, and therefore to multiple potential thermal histories. Ignoring convective effects leads to results that are inconsistent with experiments, even for the mild melt pools here.

42 ENGINEERING↗

Photovoltaic properties of interfaces of organic films of substituted perylene with TiO{sub 2} and SnO{sub 2} surfaces

The photovoltaic effect has been detected and studied in structures based on ultrathin vacuum-deposited organic films of perylene-3,4,9,10-tetracarboxylic acid dianhydride on the titanium and tin dioxide surfaces. The interfacial potential barrier shape in these structures is studied by low-energy electron total current spectroscopy. Changes in the surface potential upon exposure to visible light are recorded in situ using an electron-beam probe with energies from 0 to 25 eV. The photovoltage is detected at incident photon energies of 1.5-2.5 eV, which corresponds to the organic film absorption range and simultaneously to the transmission band of titanium and tin dioxides. An analysis of the spectral distributions and transient responses shows that two components of the observed photovoltage can be distinguished. The relation of one of the components to the excitation of interband transitions in the organic film and another component to electronic transitions involving interfacial energy states are discussed.

36 MATERIALS SCIENCE↗

SU-F-P-21: Study of Dosimetry Accuracy of Small Passively Scattered Proton Beam Fields

Purpose: To study the accuracy of the dose distribution of very small irregular fields of passively scattered proton beams calculated by the analytical pencil beam model of the Eclipse treatment planning system (TPS). Methods: An irregular field with a narrow region (width < 1 cm) that was used for the treatment of a small volume adjacent to a previously treated area were chosen for this investigation. Point doses at different locations inside the field were measured with a small volume ion chamber (A26, Standard Imaging). 2-D dose distributions were measured using a 2-D ion chamber array (MatriXX, IBA). All the measurements were done in plastic water phantom. The measured dose distributions were compared with the verification plan dose calculated in a water like phantom for the patient treatment field without the use of the compensator. Results: Point doses measured with the ion chamber in the narrowest section of the field were found to differ as much as 10% from the Eclipse calculated dose at some of the points. The 2-D dose distribution measured with the MatriXX which was validated by comparison with limited film measurement, at the proximal 95%, center of the spread out Bragg Peak and distal 90% depths agreed reasonably well with the TPS calculated dose distribution with more than 92% of the pixels passing the 2% / 2 mm dose distance agreement. Conclusion: The dose calculated by the pencil beam model of the Eclipse TPS for narrow irregular fields may not be accurate within 5% at some locations of the field, especially at the points close to the field edge due to the limitation of the dose calculation model. Overall accuracy of the calculated 2-D dose distribution was found to be acceptable for the 2%/2 mm dose/distance agreement with the measurement.

60 APPLIED LIFE SCIENCES↗

How well do time-integrated K{sub {alpha}} images represent hot electron spatial distributions?

A computational study is described, which addresses how well spatially resolved time-integrated K{sub {alpha}} images recorded in intense laser-plasma experiments correlate with the distribution of ''hot'' (>1 MeV) electrons as they propagate through the target. The hot electron angular distribution leaving the laser-plasma region is critically important for many applications such as Fast Ignition or laser based x-ray sources; and K{sub {alpha}} images are commonly used as a diagnostic. It is found that K{sub {alpha}} images can easily mislead due to refluxing and other effects. Using the particle-in-cell code LSP, it is shown that a K{sub {alpha}} image is not solely determined by the initial population of forward directed hot electrons, but rather also depends upon ''delayed'' hot electrons, and in fact continues to evolve long after the end of the laser interaction. Of particular note, there is a population of hot electrons created during the laser-plasma interaction that acquire a velocity direction opposite that of the laser and subsequently reflux off the front surface of the target, deflect when they encounter magnetic fields in the laser-plasma region, and then traverse the target in a wide spatial distribution. These delayed fast electrons create significant features in the K{sub {alpha}} time-integrated images. Electrons refluxing from the sides and the back of the target are also found to play a significant role in forming the final K{alpha} image. The relative contribution of these processes is found to vary depending on depth within target. These effects make efforts to find simple correlations between K{alpha} images and, for example, Fast Ignition relevant parameters prone to error. Suggestions for future target design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of jet observables sensitive to $\textit{b}$-quark fragmentation in $t\bar{t}$ events at the LHC with the ATLAS detector

Several observables sensitive to the fragmentation of $\textit{b}$ quarks into $\textit{b}$ hadrons are measured using 36 fb -1 of $\sqrt{s}$ = 13 TeV proton-proton collision data collected with the ATLAS detector at the LHC. Jets containing b hadrons are obtained from a sample of dileptonic $t\bar{t}$ events, and the associated set of charged-particle tracks is separated into those from the primary $\textit{pp}$ interaction vertex and those from the displaced b-decay secondary vertex. This division is used to construct observables that characterize the longitudinal and transverse momentum distributions of the $\textit{b}$ hadron within the jet. The measurements have been corrected for detector effects and provide a test of heavy-quark-fragmentation modeling at the LHC in a system where the top-quark decay products are color connected to the proton beam remnants. The unfolded distributions are compared with the predictions of several modern Monte Carlo parton-shower generators and generator tunes, and a wide range of agreement with the data is observed, with $\textit{p}$ values varying from 5 × 10 -4 to 0.98. These measurements complement similar measurements from $e^+e^-$ collider experiments in which the $\textit{b}$ quarks originate from a color singlet $Z/γ^{\ast}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma turbulence in the downstream ionosheath of Venus

Observations made by the Pioneer Venus Orbiter plasma analyzer and the plasma wave instrument in the Venus ionosheath are compared. Large increases in plasma wave turbulence levels appear to be connected with changing plasma distributions and interpenetrating plasma beams. Some of these plasma waves are identified as Doppler - shifted ion acoustic waves due to beam/beam interactions, but it is noted that different forms of instabilities are probably also operative. The changes in the temperature, intensity and energy of the peak in the PVO plasma distributions are similar to those observed by Venera 10 closer to the planet and appear to be evidence for rarefaction and compression in the downstream ionosheath. Some of the changes in the PVO plasma distributions may be related to the presence of a second ion population or the acceleration of protons.

Intriligator, D. S.↗

Experimental evidences for emittance degradation by space charge effect when using a focusing solenoid below an electron cyclotron resonance ion source

Solenoids are widely used to provide initial focusing of beams extracted from an ion source. However, in the case of an electron cyclotron resonance (ECR) ion source, the extracted beam will usually include different ion species and for each of them a wide distribution of charge states. When such a multicomponent beam is focused by a solenoid, the ions with a Q/A larger than the beam of interest are overfocused and usually go through a waist before reaching the analyzing magnet. If the beam currents obtained for these ions are sufficient, the resulting space charge forces can significantly degrade the emittance of the beam components with a lower Q/A and result for those in a hollow beam. Using a beam viewer and an emittance-measuring device, this paper reports on experimental findings that confirm the existence of such an effect for low charge states of argon. Moreover, by changing the experimental conditions of the ECR plasma in order to modify the charge state distribution of the extracted ion beam, it is shown that the threshold where this space charge effect starts to be significant can be changed.

43 PARTICLE ACCELERATORS↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

Soft X-ray spectrometer design for warm dense plasma measurements on DARHT Axis-I

A preliminary design study is being performed on a soft X-ray spectrometer to measure K-shell spectra emitted by a warm dense plasma generated on Axis-I of the Dual-Axis Radiographic Hydrodynamic Testing (DARHT) facility at Los Alamos National Laboratory. The 100-ns-long intense, relativistic electron pulse with a beam current of 1.7 kA and energy of 19.8 MeV deposits energy into a thin metal foil heating it to a warm dense plasma. The collisional ionization of the target by the electron beam produces an anisotropic angular distribution of K-shell radiation and a continuum of both scattered electrons and Bremsstrahlung up to the beam energy of 19.8 MeV. The principal goal of this project is to characterize these angular distributions to determine the optimal location to deploy the soft X-ray spectrometer. In addition, a proof-of-principle design will be presented. The ultimate goal of the spectrometer is to obtain measurements of the plasma temperature and density to benchmark equation-of-state models of the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recycler lattice for Project X at Fermilab

Project X is an intense proton source that provides beam for various physics programs. The source consists of an 8 GeV H- superconducting linac that injects into the Fermilab Recycler where H- are converted to protons. Protons are provided to the Main Injector and accelerated to desired energy (in the range 60-120 GeV) or extracted from the Recycler for the 8 GeV program. A long drift space is needed to accommodate the injection chicane with stripping foils. The Recycler is a fixed 8 GeV kinetic energy storage ring using permanent gradient magnets. A phase trombone straight section is used to control the tunes. In this paper, the existing FODO lattice in RR10 straight section being converted into doublet will be described. Due to this change, the phase trombone straight section has to be modified to bring the tunes to the nominal working point. A toy lattice of recycler ring is designed to simulate the end-shim effects of each permanent gradient magnet to add the flexibility to handle the tune shift to the lattice during the operation of 1.6E14 with KV distribution of the proton beam to give {approx}0.05 of space charge tune shift. The comparison or the combinations of the two modification ways for the Recycler ring lattice will be presented also in this paper.

43 PARTICLE ACCELERATORS↗

A Review of Advanced Characterization Methods and Techniques for Amorphous and Poorly Crystalline Materials Applicable to Cementitious Waste Forms

This review covers advanced characterization methods of cementitious materials. The particular focus is to understand cementitious compositions with amorphous content because conventional techniques such as X-ray diffraction are more applicable to materials with long range order. Also of interest is advanced characterization that provides deeper insights into properties such as porosity. There are five groups of characterization methods discussed in this review which are: electron beam/microscopy, X-ray, neutron diffraction and scattering, nuclear magnetic resonance, and optical techniques. The techniques can be further grouped by the categories of nanoscale structural understanding (transmission electron microscopy and pair distribution function), microscale structural understanding (focused ion beam and x-ray tomography), microscopic elemental distributions (energy dispersive spectroscopy and X-ray fluorescence), and chemical binding information (electron energy loss spectroscopy, x-ray absorption spectroscopy, nuclear magnetic resonance, Raman spectroscopy, and infrared spectroscopy), with advantages and disadvantages of each method discussed. The recommendation for further research is to begin with techniques that are easier to prepare samples for, measure, and analyze, such as the optical techniques of Raman and infrared spectroscopy. If more information is needed, pursue collaborations, other techniques, or proposals for beam time at the synchrotron sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k{sub Q} factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k{sub Q} factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k{sub Q} factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V{sub cyl} which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V{sub cyl}: (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V{sub cyl}, no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k{sub Q} factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k{sub Q{sub p{sub c{sub s{sub r,Q{sub m{sub s{sub r}{sup f{sub p}{sub c}{sub s}{sub r},f{sub m}{sub s}{sub r}}}}}}}}}=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.

60 APPLIED LIFE SCIENCES↗

Effect of antisymmetric C–H stretching excitation on the dynamics of O({sup 1}D) + CH{sub 4} → OH + CH{sub 3}

The effect of antisymmetric C–H stretching excitation of CH{sub 4} on the dynamics and reactivity of the O({sup 1}D) + CH{sub 4} → OH + CD{sub 3} reaction at the collision energy of 6.10 kcal/mol has been investigated using the crossed-beam and time-sliced velocity map imaging techniques. The antisymmetric C–H stretching mode excited CH{sub 4} molecule was prepared by direct infrared excitation. From the measured images of the CH{sub 3} products with the infrared laser on and off, the product translational energy and angular distributions were derived for both the ground and vibrationally excited reactions. Experimental results show that the vibrational energy of the antisymmetric stretching excited CH{sub 4} reagent is channeled exclusively into the vibrational energy of the OH co-products and, hence, the OH products from the excited-state reaction are about one vibrational quantum hotter than those from the ground-state reaction, and the product angular distributions are barely affected by the vibrational excitation of the CH{sub 4} reagent. The reactivity was found to be suppressed by the antisymmetric stretching excitation of CH{sub 4} for all observed CH{sub 3} vibrational states. The degree of suppression is different for different CH{sub 3} vibrational states: the suppression is about 40%–60% for the ground state and the umbrella mode excited CH{sub 3} products, while for the CH{sub 3} products with one quantum symmetric stretching mode excitation, the suppression is much less pronounced. In consequence, the vibrational state distribution of the CH{sub 3} product from the excited-state reaction is considerably different from that of the ground-state reaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preferential heating of oxygen 5{sup +} ions by finite-amplitude oblique Alfvén waves

Minor ions in the fast solar wind are known to have higher temperatures and to flow faster than protons in the interplanetary space. In this study we combine previous research on parametric instability theory and 2.5D hybrid simulations to study the onset of preferential heating of Oxygen 5{sup +} ions by large-scale finite-amplitude Alfvén waves in the collisionless fast solar wind. We consider initially non-drifting isotropic multi-species plasma, consisting of isothermal massless fluid electrons, kinetic protons and kinetic Oxygen 5{sup +} ions. The external energy source for the plasma heating and energization are oblique monochromatic Alfvén-cyclotron waves. The waves have been created by rotating the direction of initial parallel pump, which is a solution of the multi-fluid plasma dispersion relation. We consider propagation angles θ ≤ 30°. The obliquely propagating Alfvén pump waves lead to strong diffusion in the ion phase space, resulting in highly anisotropic heavy ion velocity distribution functions and proton beams. We discuss the application of the model to the problems of preferential heating of minor ions in the solar corona and the fast solar wind.

43 PARTICLE ACCELERATORS↗

BASS. XXXIII. Swift-BAT Blazars and Their Jets through Cosmic Time

We derive the most up-to-date Swift-Burst Alert Telescope (BAT) blazar luminosity function in the 14–195 keV range, making use of a clean sample of 118 blazars detected in the BAT 105 month survey catalog, with newly obtained redshifts from the BAT Active Galatic Nucleus Spectroscopic Survey. We determine the best-fit X-ray luminosity function for the whole blazar population, as well as for flat-spectrum radio quasars (FSRQs) alone. The main results are: (1) at any redshift, BAT detects the most luminous blazars, above any possible break in their luminosity distribution, which means we cannot differentiate between density and luminosity evolution; (2) the whole blazar population, dominated by FSRQs, evolves positively up to redshift z ~ 4.3, confirming earlier results and implying lower number densities of blazars at higher redshifts than previously estimated. The contribution of this source class to the cosmic X-ray background at 14–195 keV can range from 5%–18%, while possibly accounting for 100% of the MeV background. We also derived the average 14 keV–10 GeV spectral energy distribution for BAT blazars, which allows us to predict the number counts of sources in the MeV range, as well as the expected number of high-energy (>100 TeV) neutrinos. A mission like COSI will detect 40 MeV blazars, of which two may have coincident neutrino detections. Finally, taking into account beaming selection effects, the distribution and properties of the parent population of these extragalactic jets are derived. We find that the distribution of viewing angles is quite narrow, with most sources aligned within <5° of the line of sight. Moreover, the average Lorentz factor, $\langle$Γ$\rangle$ = 8–12, is lower than previously suggested for these powerful sources.

79 ASTRONOMY AND ASTROPHYSICS↗