Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Developing Urban Air Mobility Vehicle Models to Support Air Traffic Management Concept Development

To support Urban Air Mobility (UAM) research efforts at NASA, the Airspace Target Generator (ATG) software used in the FutureFlight Central (FFC) air traffic control tower simulator is undergoing updates to support physics-based UAM vehicle models. A process was developed to integrate UAM vertical takeoff and landing (VTOL) aircraft into the fixed-wing ATG modeling environment without significant change to the underlying equations of motion and vehicle model database. The VTOL aircraft models were converted from a six degrees-of-freedom (6-DOF) representation into a four degrees-of-freedom (4-DOF) representation for integration within ATG. Three vehicle designs from the NASA Revolutionary Vertical-Lift Technologies (RVLT) project were selected: a lift-plus-cruise (LPC) aircraft model and quadrotor, electric-powered (QEP) 1-seater and 6-seater models. With the LPC model comprised of a nonlinear force and moment build-up, and the QEP models comprised of linearized stability derivatives, two separate processes were developed to convert the lift, drag, and propulsion characteristics of each model into the ATG model database. Key aircraft performance characteristics including climb, cruise, and descent performance were preserved during the conversion process. Because ATG simulates fixed-wing aircraft through ground taxi and takeoff to approach and landing, acceleration command algorithms were developed to model the vertical takeoff and vertical landing phase of UAM operations. A strategy was then developed to transition the aircraft model to- and from- the new control mode.

urban air mobility↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

Dynamic Modeling, Controls, and Testing for Electrified Aircraft

Electrified aircraft have the potential to provide significant benefits for efficiency and emissions reductions. To assess these potential benefits, modeling tools are needed to provide rapid evaluation of diverse concepts and to ensure safe operability and peak performance over the mission. The modeling challenge for these vehicles is the ability to show significant benefits over the current highly refined aircraft systems. The STARC-ABL (single-aisle turbo-electric aircraft with an aft boundary layer propulsor) is a new test proposal that builds upon previous N3-X team hybrid designs. This presentation describes the STARC-ABL concept, the NASA Electric Aircraft Testbed (NEAT) which will allow testing of the STARC-ABL powertrain, and the related modeling and simulation efforts to date. Modeling and simulation includes a turbofan simulation, Numeric Propulsion System Simulation (NPSS), which has been integrated with NEAT; and a power systems and control model for predicting testbed performance and evaluating control schemes. Model predictions provide good comparisons with testbed data for an NPSS-integrated test of the single-string configuration of NEAT.

Connolly, Joseph↗

A laboratory validation study of the time-lapse oscillatory pumping test for leakage detection in geological repositories

Geologic repositories are extensively used for disposing byproducts in mineral and energy industries. The safety and reliability of these repositories are a primary concern to environmental regulators and the public. Time-lapse oscillatory pumping test (OPT) has been introduced recently as a pressure-based technique for detecting potential leakage in geologic repositories. By routinely conducting OPT at a number of pulsing frequencies, an operator may identify the potential repository anomalies in the frequency domain, alleviating the ambiguity caused by reservoir noise and improving the signal-to-noise ratio. Building on previous theoretical and field studies, this work performed a series of laboratory experiments to validate the concept of time-lapse OPT using a custom made, stainless steel tank under relatively high pressures. The experimental configuration simulates a miniature geologic storage repository consisting of three layers (i.e., injection zone, caprock, and above-zone aquifer). Here results show that leakage in the injection zone led to deviations in the power spectrum of observed pressure data, and the amplitude of which also increases with decreasing pulsing frequencies. The experimental results are further analyzed by developing a 3D flow model, using which the model parameters are estimated through frequency domain inversion.

58 GEOSCIENCES↗

Radiation damage in cubic ZrO 2 and yttria-stabilized zirconia from molecular dynamics simulations

Here, we perform molecular dynamics simulation on cubic ZrO 2 and yttria-stabilized zirconia (YSZ) to elucidate defect cluster formation resulting from radiation damage, and evaluate the impact of Y-dopants. Interstitial clusters composed of split-interstitial building blocks, i.e., Zr-Zr or Y-Zr are formed. Moreover, oxygen vacancies control cation defect migration; in their presence, Zr interstitials aggregate to form split-interstitials whereas in their absence Zr interstitials remain immobile, as isolated single-interstitials. Y-doping prevents interstitial cluster formation due to sequestration of oxygen vacancies.

36 MATERIALS SCIENCE↗

OpenStudio®-MCP [SWR-26-035]

OpenStudio®-MCP is a Model Context Protocol (MCP) server that lets AI assistants perform building energy modeling through natural language. Rather than requiring users to learn the OpenStudio® SDK, EnergyPlus® scripting, or Ruby/Python automation, the server translates conversational requests into sequences of tool calls that create models, design HVAC systems, run simulations, and extract results — all within a single chat session. The server's 124 tools are organized into a skills architecture where each skill encapsulates a domain of building energy modeling (envelope, HVAC, loads, weather, simulation, results) behind typed, LLM-friendly interfaces. High-leverage operations like applying ASHRAE 90.1 baseline systems or generating standards-compliant typical buildings are exposed as single tool calls that internally wire dozens of OpenStudio® objects. Bundled measures from ComStock™ and Openstudio® -common-measures-gem are wrapped with dedicated tools and typed arguments rather than exposed through a generic measure interface, so AI models get consistent, error-resistant recipes without needing to discover measure arguments at runtime. A key design decision is structured results extraction: six SQL-based tools return surgical ~300–1,000 token responses (end-use breakdowns, envelope summaries, HVAC sizing, timeseries data) instead of requiring the AI to parse ~100K-token raw HTML reports, making iterative design exploration practical within context window limits. The codebase is designed as a reference implementation — explicit, well-commented, and modular — so that other simulation engines (EnergyPlus® standalone, TRNSYS, DOE-2) can use it as a template for building their own MCP servers.

Ball, Brian [National Laboratory of the Rockies (N↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical simulation of Ulysses nutation

A numerical simulation has been performed on the in-orbit instability of the Ulysses Spacecraft. The thermal excitation from the solar flux, the flexible axial boom and its deployment mechanism have been modeled and analyzed. The simulation shows that the nutation build-up has been originated by the solar input on the axial boom coupled with the system nutation frequency of the spacecraft. The results agree with the observed behavior.

Marirrodriga, C. Garcia↗

Validation of an Accurate Three-Dimensional Helical Slow-Wave Circuit Model

The helical slow-wave circuit embodies a helical coil of rectangular tape supported in a metal barrel by dielectric support rods. Although the helix slow-wave circuit remains the mainstay of the traveling-wave tube (TWT) industry because of its exceptionally wide bandwidth, a full helical circuit, without significant dimensional approximations, has not been successfully modeled until now. Numerous attempts have been made to analyze the helical slow-wave circuit so that the performance could be accurately predicted without actually building it, but because of its complex geometry, many geometrical approximations became necessary rendering the previous models inaccurate. In the course of this research it has been demonstrated that using the simulation code, MAFIA, the helical structure can be modeled with actual tape width and thickness, dielectric support rod geometry and materials. To demonstrate the accuracy of the MAFIA model, the cold-test parameters including dispersion, on-axis interaction impedance and attenuation have been calculated for several helical TWT slow-wave circuits with a variety of support rod geometries including rectangular and T-shaped rods, as well as various support rod materials including isotropic, anisotropic and partially metal coated dielectrics. Compared with experimentally measured results, the agreement is excellent. With the accuracy of the MAFIA helical model validated, the code was used to investigate several conventional geometric approximations in an attempt to obtain the most computationally efficient model. Several simplifications were made to a standard model including replacing the helical tape with filaments, and replacing rectangular support rods with shapes conforming to the cylindrical coordinate system with effective permittivity. The approximate models are compared with the standard model in terms of cold-test characteristics and computational time. The model was also used to determine the sensitivity of various circuit parameters including typical manufacturing dimensional tolerances and support rod permittivity. By varying the circuit parameters of an accurate model using MAFIA, these sensitivities can be computed for manufacturing concerns, and design optimization previous to fabrication, thus eliminating the need for costly experimental iterations. Several variations were made to a standard helical circuit using MAFIA to investigate the effect that variations on helical tape and support rod width, metallized loading height and support rod permittivity, have on TWT cold-test characteristics.

Kory, Carol L.↗

Impact of Installation Faults on Heat Pump Performance

Numerous studies and surveys indicate that typically-installed HVAC equipment operate inefficiently and waste considerable energy due to varied installation errors (faults) such as improper refrigerant charge, incorrect airflow, oversized equipment, and leaky ducts. This article summarizes the results of a large United States (U.S.) experimental/analytical study (U.S. contribution to IEA HPP Annex 36) of the impact that different faults have on the performance of an air-source heat pump (ASHP) in a typical U.S. single-family house. It combines building effects, equipment effects, and climate effects in an evaluation of the faults impact on seasonal energy consumption through simulations of the house/ASHP pump system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques: Preprint

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory and the University of Minnesota are conducting a three-year, multipart study on residential retrofit wall assemblies. The project is funded by the U.S. Department of Energy’s Building Technology Office and will identify, test and verify wall assemblies for hygrothermal performance in retrofit applications. The study includes a comprehensive literature review and expert advisory group, which inform wall selection. Selected wall assemblies are then thermally simulated using EnergyPlus and THERM, and hygrothermally simulated using WUFI, to model both thermal and moisture performance of the wall assembly. Eight wall assemblies are then experimentally tested in an in-situ laboratory environment at the University of Minnesota, with a typical residential wall used as a baseline. The in-situ experiment looks at the physical hygrothermal performance of each assembly. The simulation and experimental results will be combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits. This paper presents progress after year one of the study. Wall system modeling and laboratory testing is scheduled to begin in November, 2019. We will discuss the parameters for wall selection and experimental design, which includes approaches to modeling and simulation, along with the physical experiment design. This paper will also outline the parameters for the techno-economic analysis, and criteria used to inform model development.

Antonopoulos, Chrissi A.↗

Machine Learning for DUNE Supernova Trigger

One of the major scientific goals of the Deep Underground Neutrino Experiment (DUNE) is to detect and measure the neutrino flux originating from galactic core-collapse supernovae. These neutrinos provide an opportunity to study the end of life evolution of massive stars, and reveal information about the structure of core-collapse that is not visible in observations of the electromagnetic spectrum. Because of the rarity of these events, it is crucial that DUNE is able to detect supernova neutrino interactions when they occur. However, this will require sifting through a large quantity of data, motivating the development of a trigger algorithm to identify significant events and discard irrelevant data. Machine learning provides a potential approach to building this trigger. This project generates ADC and ground truth images of simulated neutrino interactions in a LArTPC detector to be used for machine learning, and uses them to train a sparse Convolutional Neural Network (C NN). The performance of this model when applied to the task of pixel classification based on interaction type is examined. This project found that the sparse CNN approach has the potential to have high accuracy in pixel classification, meaning it may be highly relevant to the development of a supernova neutrino trigger for the DUNE far detector.

Damish, S.↗

Human System Simulation in Support of Human Performance Technical Basis at NPPs

This paper focuses on strategies and progress toward establishing the Idaho National Laboratory’s (INL’s) Human Systems Simulator Laboratory at the Center for Advanced Energy Studies (CAES), a consortium of Idaho State Universities. The INL is one of the National Laboratories of the US Department of Energy. One of the first planned applications for the Human Systems Simulator Laboratory is implementation of a dynamic nuclear power plant simulation (NPP) where studies of operator workload, situation awareness, performance and preference will be carried out in simulated control rooms including nuclear power plant control rooms. Simulation offers a means by which to review operational concepts, improve design practices and provide a technical basis for licensing decisions. In preparation for the next generation power plant and current government and industry efforts in support of light water reactor sustainability, human operators will be attached to a suite of physiological measurement instruments and, in combination with traditional Human Factors Measurement techniques, carry out control room tasks in simulated advanced digital and hybrid analog/digital control rooms. The current focus of the Human Systems Simulator Laboratory is building core competence in quantitative and qualitative measurements of situation awareness and workload. Of particular interest is whether introduction of digital systems including automated procedures has the potential to reduce workload and enhance safety while improving situation awareness or whether workload is merely shifted and situation awareness is modified in yet to be determined ways. Data analysis is carried out by engineers and scientists and includes measures of the physical and neurological correlates of human performance. The current approach supports a user-centered design philosophy (see ISO 13407 “Human Centered Design Process for Interactive Systems, 1999) wherein the context for task performance along with the requirements of the end-user are taken into account during the design process and the validity of design is determined through testing of real end users

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Thermal balance of a wall with PCM-enhanced thermal insulation

ABSTRACT: PCM insulation mixtures function as lightweight thermal mass components. It is expected that these types of dynamic insulation systems will contribute to the objective of reducing energy use in buildings. In this paper, dynamic thermal properties of a material in which phase hange occurs are analyzed, using the temperature-dependent specific heat model. Integral formula for the total heat flow in finite time interval, across the surface of a slab of the phase change material, was derived. Simulations have been performed to analyze heat transfer through a light-weight wall assembly with PCM-enhanced insulation, in different external climate thermal conditions. Results of simulations indicate that for cyclic processes, the effect of PCM in an insulation layer results rather in time shifting of the heat flux extreme values than in reduction of the total heat flow. The heat gains maxima, resulting in high cooling loads, are shifted in time by about two hours and reduced about 15% to 30% for not very high external sol-air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗