Search NASA⌕ Search

SEARCH · Search NASA

Results for “Color Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: What level is achievable?

This paper focuses on the accuracy, in absolute dose measurements, with GafChromic EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum-assisted associative adversarial network: applying quantum annealing in deep learning

Abstract Generative models have the capacity to model and generate new examples from a dataset and have an increasingly diverse set of applications driven by commercial and academic interest. In this work, we present an algorithm for learning a latent variable generative model via generative adversarial learning where the canonical uniform noise input is replaced by samples from a graphical model. This graphical model is learned by a Boltzmann machine which learns low-dimensional feature representation of data extracted by the discriminator. A quantum processor can be used to sample from the model to train the Boltzmann machine. This novel hybrid quantum-classical algorithm joins a growing family of algorithms that use a quantum processor sampling subroutine in deep learning, and provides a scalable framework to test the advantages of quantum-assisted learning. For the latent space model, fully connected, symmetric bipartite and Chimera graph topologies are compared on a reduced stochastically binarized MNIST dataset, for both classical and quantum sampling methods. The quantum-assisted associative adversarial network successfully learns a generative model of the MNIST dataset for all topologies. Evaluated using the Fréchet inception distance and inception score, the quantum and classical versions of the algorithm are found to have equivalent performance for learning an implicit generative model of the MNIST dataset. Classical sampling is used to demonstrate the algorithm on the LSUN bedrooms dataset, indicating scalability to larger and color datasets. Though the quantum processor used here is a quantum annealer, the algorithm is general enough such that any quantum processor, such as gate model quantum computers, may be substituted as a sampler.

Wilson, Max (ORCID:0000000207983391)↗

Combined effects of prenatal exposure to polycyclic aromatic hydrocarbons and material hardship on child ADHD behavior problems

Highlights: • PAH are common carcinogenic and neurotoxic combustion-related air pollutants. • Exposure to PAH tends to be disproportionately high in low income communities. • Prenatal PAH exposure was measured by PAH-DNA adducts in maternal blood. • We evaluated the combined effects of prenatal PAH and material hardship on ADHD. • We observed significant effects of combined exposures on ADHD behavior problems. Polycyclic aromatic hydrocarbons (PAH) are carcinogenic and neurotoxic combustion by-products commonly found in urban air. Exposure to PAH is disproportionately high in low income communities of color who also experience chronic economic stress.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-675: Remote Dosimetry with a Novel PRESAGE Formulation

Purpose: 3D-gel dosimetry provides high-resolution treatment validation; however, scanners aren’t widely available. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote site for irradiation, then shipped back for scanning and analysis, affording a convenient service for treatment validation to institutions lacking the necessary equipment and resources. Previous works demonstrated the high-resolution performance and temporal stability of PRESAGE. Here the newest formulation is investigated for remote dosimetry use. Methods: A new formulation of PRESAGE was created with the aim of improved color stability post irradiation. Dose sensitivity was determined by irradiating cuvettes on a Varian Linac (6MV) from 0–15Gy and measuring change in optical density at 633nm. Sensitivity readings were tracked over time in a temperature control study to determine long-term stability. A large volume study was performed to evaluate the accuracy for remote dosimetry. A 1kg dosimeter was pre-scanned, irradiated on-site with an 8Gy 4field box treatment, post-scanned and shipped to Princess Margaret Hospital for remote reading on an identical scanner. Results: Dose sensitivities ranged from 0.0194–0.0295 ΔOD/(Gy*cm)—similar to previous formulations. Post-irradiated cuvettes stored at 10°C retained 100% initial sensitivity over 5 days and 98.6% over 10 weeks while cuvettes stored at room temperature fell to 95.8% after 5 days and 37.4% after 10 weeks. The immediate and 5-day scans of the 4field box dosimeter data was reconstructed, registered to the corresponding eclipse dose-distribution, and compared with analytical tools in CERR. Immediate and 5-day scans looked visually similar. Line profiles revealed close agreement aside from a slight elevation in dose at the edge in the 5-day readout. Conclusion: The remote dosimetry formulation exhibits excellent temporal stability in small volumes. While immediate and 5-day readout scans of large volume dosimeters show promising agreement, further development is required to reduce an apparent time dependent edge elevation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geologic remote sensing study of the Hayden pass-Orient Mine Area, Northern Sangre de Cristo Mountains, Colorado

Remote sensor data from a NASA Convair 990 radar flight and Mission 101 and 105 have been interpreted and evaluated. Based on interpretation of the remote sensor data, a geologic map has been prepared and compared with a second geologic map, prepared from interpretation of both remote sensor data and field data. Comparison of the two maps gives one indication of the usefulness and reliability of the remote sensor data. Color and color infrared photography provided the largest amount of valuable information. Multiband photography was of lesser value and side-looking radar imagery provided no new information that was not available on small scale photography. Thermal scanner imagery proved to be a very specialized remote sensing tool that should be applied to areas of low relief and sparse vegetation where geologic features produce known or suspected thermal contrast. Low sun angle photography may be a good alternative to side-looking radar imagery but must be flown with critical timing.

Wychgram, D. C.↗

Water depth penetration film test

As part of the National Aeronautics and Space Administration Earth Resources Program, a comparative and controlled evaluation of nine film-filter combinations was completed to establish the relative effectiveness in recording water subsurface detail if exposed from an aerial platform over a typical water body. The films tested, with one exception, were those which prior was suggested had potential. These included an experimental 2-layer positive color film, a 2-layer (minus blue layer) film, a normal 3-layer color film, a panchromatic black-and-white film, and a black-and-white infrared film. Selective filtration was used with all films.

Lockwood, H. E.↗

Results from the National Aeronautics and Space Administration remote sensing experiments in the New York Bight, 7-17 April 1975

A cooperative operation was conducted in the New York Bight to evaluate the role of remote sensing technology to monitor ocean dumping. Six NASA remote sensing experiments were flown on the C-54, U-2, and C-130 NASA aircraft, while NOAA obtained concurrent sea truth information using helicopters and surface platforms. The experiments included: (1) a Radiometer/Scatterometer (RADSCAT), (2) an Ocean Color Scanner (OCS), (3) a Multichannel Ocean Color Sensor (MOCS), (4) four Hasselblad cameras, (5) an Ebert spectrometer; and (6) a Reconafax IV infrared scanner and a Precision Radiation Thermometer (PRT-5). The results of these experiments relative to the use of remote sensors to detect, quantify, and determine the dispersion of pollutants dumped into the New York Bight are presented.

Hall, J. B., Jr.↗

Validation of the DESI DR2 Ly$α$ forest full-shape analysis

We present the validation of the Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2) Lyman-$α$ (Ly$α$) forest full-shape analysis. This analysis combines three-dimensional Ly$α$ forest auto-correlations and cross-correlations with quasars to extract information from both the baryon acoustic oscillation (BAO) feature and the broadband clustering signal, with primary emphasis on the Alcock-Paczynski (AP) measurement. Compared to the DESI DR1 analysis, the DR2 validation uses substantially larger and more realistic mock datasets, including CoLoRe 2LPT and AbacusSummit Ly$α$ forest simulations. The modeling framework is also improved through analytic marginalization over small scales ($<10$$h^{-1}$Mpc) and the impact of ultraviolet background fluctuations. The validation program was completed prior to unblinding and defines quantitative requirements for the cosmological parameters of interest, which are evaluated using hundreds of mock realizations. We further test the analysis through independent fits to the auto- and cross-correlations, multiple catalog splits, and a broad suite of analysis and modeling variations applied to both mocks and blinded observational data. We find that the BAO and AP parameters satisfy all validation requirements and remain stable across all tests. In contrast, mock studies reveal a significant bias in the inferred growth-rate parameter $fσ_8$, leading us to exclude this measurement from the final analysis. The consistency across mocks, data splits, and robustness tests demonstrates that the DR2 Ly$α$ full-shape analysis provides a reliable and substantially improved broadband AP measurement over previous Ly$α$ forest studies.

Herbold, M. [Chicago U., KICP; Ohio State U.] (ORC↗

To assess the value of satellite photographs in resource evaluation on a national scale

The author has identified the following significant results. The limit of resolution on ERTS imagery is normally acknowledged to be about 60 miles although very long features such as roads and railways which are often less than 10 miles long are easily detectable. An example is the north-south road and railway from Lobatse to Francistown. Vegetation growth from winter to summer is readily monitored on false color imagery. The limits of government ranches and special farming areas can be quite accurately ascertained from ERTS imagery. Another aspect to which ERTS imagery lends itself is the location and demarcation of bush fires, many of which were seen on the first imagery which was acquired at the end of the cold, dry season. As a whole, MSS 7 offers maximum reflectance contrast among black and white imagery and is the wavelength used most for interpretation.

Hepworth, J. V.↗

Evaluation of thermal data for geologic applications

Sensitivity studies using thermal models indicated sources of errors in the determination of thermal inertia from HCMM data. Apparent thermal inertia, with only simple atmospheric radiance corrections to the measured surface temperature, would be sufficient for most operational requirements for surface thermal inertia. Thermal data does have additional information about the nature of surface material that is not available in visible and near infrared reflectance data. Color composites of daytime temperature, nighttime temperature, and albedo were often more useful than thermal inertia images alone for discrimination of lithologic boundaries. A modeling study, using the annual heating cycle, indicated the feasibility of looking for geologic features buried under as much as a meter of alluvial material. The spatial resolution of HCMM data is a major limiting factor in the usefulness of the data for geologic applications. Future thermal infrared satellite sensors should provide spatial resolution comparable to that of the LANDSAT data.

Kahle, A. B.↗

Green synthesis of gold nanoparticles using aqueous ethanol extract of Curcuma mangga rhizomes as reducing agent

Green synthesis of gold nanoparticles (AuNPs) had been developed as an alternative to chemical and physical methods due to its simplicity, cost effectiveness and eco-friendliness. The high biocompatibility and biostability features of AuNPs have found importance in biomedical applications in recent years. In this study, aqueous ethanol extract of Curcuma mangga rhizomes which acts as reducing and stabilizing agent was used to synthesize stable AuNPs by bioreduction of chloroauric acid. The formation of AuNPs was highlighted by the color change of the suspension from light yellow to reddish purple. Time-evolution was monitored by UV-visible spectroscopy, while surface plasmon (SP) absorption band of the AuNPs suspension was observed at a maximum absorption of 540 nm. Hydrodynamic radii and size distribution of the AuNPs in the suspension were evaluated using dynamic light scattering (DLS) and zeta potential measurement demonstrated negative surface charge. The particle size was calculated in the range of 2-30 nm using High Resolution Transmission Electron Microscopy (HRTEM). The morphology and elemental composition were further determined by Field Effect Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray (EDX) spectroscopy. Fourier transform infrared (FTIR) spectroscopy meanwhile was used to confirm the presence of AuNPs and functional groups involved in the gold bio-reduction process. Influence of the volume of extract and concentration of gold (III) chloride trihydrate (HAuCl{sub 4}.3H{sub 2}O) on the synthesis of AuNPs were also investigated. The results obtained indicate potential optimization and functionalization of AuNPs for future applications in bionanotechnology especially in the field of medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the first ionization potential of technetium

The first ionization potential (IP) of technetium (Tc) has been determined by evaluating Rydberg convergences toward the first ionization potential as well as toward two low-lying excited states of the singly charged Tc ion. The Rydberg states were excited and detected by applying multiphoton resonance ionization mass spectrometry (RIMS) on the long-lived isotope {sup 99g}Tc using a three-color excitation scheme. The observed Rydberg convergences yield a result for the first ionization potential of Tc V{sub IP}(Tc)=7.119380(32) eV. This precise value for V{sub IP}(Tc) is somewhat lower than the so far published data of 7.23 eV or 7.28 eV, dating back to the 1950s.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhanced contribution of the pairing gap to the QCD equation of state at large isospin chemical potential

In this paper QCD at large isospin density is studied, which is known to be in the superfluid state with Cooper pairs carrying the same quantum number as pions. The gap equation derived from the perturbation theory up to the next-to-leading-order corrections is solved. The pairing gap at large isospin chemical potential is found to be enhanced compared to the color-superconducting gap at large baryon chemical potential due to the 2 difference in the exponent arising from the stronger attraction in one-gluon exchange in the singlet channel. Then, using the gap function, the contribution of the condensation energy of the superfluid state to the QCD equation of state is evaluated. At isospin chemical potential of a few GeV, where the lattice QCD and the perturbative QCD can be both applied, the effect of the condensation energy becomes dominant even compared to the next-to-leading order corrections to the pressure in the perturbation theory. It resolves the discrepancy between the recent lattice QCD results and the perturbative QCD result. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Transverse momentum broadening of vector boson production in high energy nuclear collisions

We calculate in perturbative QCD the transverse momentum broadening of vector boson production in high energy nuclear collisions. We evaluate the effect of initial-state parton multiple scattering for the production of the Drell-Yan virtual photon and W/Z bosons. We calculate both the initial- and final-state multiple scattering effect for the production of heavy quarkonia and their transverse momentum broadening in both nonrelativistic QCD and the color evaporation model of quarkonium formation. We find that J/{psi} and {upsilon} broadening in hadron-nucleus collision is close to 2C{sub A}/C{sub F} times the corresponding Drell-Yan broadening, which gives a good description of existing Fermilab data. Our calculations are also consistent with Relativistic Heavy Ion Collider data on J/{psi} broadening in relativistic heavy ion collisions. We predict the transverse momentum broadening of vector boson (J/{psi}, {upsilon}, and W/Z) production in relativistic heavy ion collisions at the Large Hadron Collider and discuss the role of the vector boson broadening in diagnosing medium properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection

We are investigating three-dimensional (3D) to two-dimensional (2D) registration methods for computed tomography (CT) and dual-energy digital radiography (DEDR). CT is an established tool for the detection of cardiac calcification. DEDR could be a cost-effective alternative screening tool. In order to utilize CT as the 'gold standard' to evaluate the capability of DEDR images for the detection and localization of calcium, we developed an automatic, intensity-based 3D-to-2D registration method for 3D CT volumes and 2D DEDR images. To generate digitally reconstructed radiography (DRR) from the CT volumes, we developed several projection algorithms using the fast shear-warp method. In particular, we created a Gaussian-weighted projection for this application. We used normalized mutual information (NMI) as the similarity measurement. Simulated projection images from CT values were fused with the corresponding DEDR images to evaluate the localization of cardiac calcification. The registration method was evaluated by digital phantoms, physical phantoms, and clinical data sets. The results from the digital phantoms show that the success rate is 100% with a translation difference of less than 0.8 mm and a rotation difference of less than 0.2 deg. . For physical phantom images, the registration accuracy is 0.43{+-}0.24 mm. Color overlay and 3D visualization of clinical images show that the two images registered well. The NMI values between the DRR and DEDR images improved from 0.21{+-}0.03 before registration to 0.25{+-}0.03 after registration. Registration errors measured from anatomic markers decreased from 27.6{+-}13.6 mm before registration to 2.5{+-}0.5 mm after registration. Our results show that the automatic 3D-to-2D registration is accurate and robust. This technique can provide a useful tool for correlating DEDR with CT images for screening coronary artery calcification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Landsat-4 thematic mapper and thematic mapper simulator data for a porphyry copper deposit

Aircraft thematic mapper (TM) data were analyzed to evaluate the potential utility of the Landsat-4 thematic mapper for geologic mapping and detection of hydrothermal alteration zones in the Silver Bell porphyry copper deposit in southern Arizona. The data allow a comparison between aircraft TV simulator data and the Landsat-4 TM satellite data which possess similar spectral bands. A color rationcomposite of 30-m pixels was resampled, in order to clearly define a number of hydroxyl bearing minerals, (kaolinite, sericite, white mica), pyrite and iron oxide/hydroxide minerals. The iron oxide minerals have diagnostic absorption bands in the 0.45 and 0.85 micron regions of the spectrum, and the hydrous minerals are characterized by an absorption in the 2.2 micron region. The position of the spectral bands allow the TM to identify regions of hydrothermal alteration without resorting to a data processing algorithm. The comparison of the aircraft and Landsat-4 TM data showed considerable agreement, and confirmed the utility of TM data for identifying hydrothermal alteration zones. Samples of some color TM images are provided.

Abrams, M. J.↗

Pilot response to avoidance regions depicted on alternate TCAS II resolution advisory displays

The objective of this study was to examine pilot reactions to three versions of the resolution advisory (RA) display of the TCAS II. Two modifications to the current system were designed to test the hypothesis that a different lighting pattern might be more effective than the 'red-only' version currently in use. Grouped into three sets, 28 RA displays of the same color pattern ('red-only', 'red-and-green', and 'green-only') were presented to 36 volunteer pilots on an IRIS terminal. The results indicated that the red-and-green display caused the least errors and hastened a quicker response than did the red-only display. Further, a subjective evaluation revealed that the pilots preferred the red-and-green display over the other two options. The red-only display caused the most errors, including seven unnecessary maneuvers. Pilots also responded slowest to this display and it was the least preferred.

Tuttell, Robert J.↗

Interventional Treatment Strategy for Primary Budd–Chiari Syndrome with Both Inferior Vena Cava and Hepatic Vein Involvement: Patients from Two Centers in China

Objective: This retrospective study evaluated interventional treatments (recanalization, balloon dilation, and/or stent placement) for Budd–Chiari syndrome (BCS), caused by combined obstruction of the inferior vena cava (IVC) and hepatic veins (HVs). Methods: Before and after interventional therapy, patients with BCS (n = 162; asymptomatic 105.2 ± 103.3 mo; follow-up 15 [6–24] mo) underwent imaging studies (color Doppler ultrasound, CT, or MRI), and inferior vena cavography and manometry. Venous lesions were characterized by occlusion features, and presence of thrombosis and peripheral collateral vessels. Results: One, 2, and 3 main HV occlusions were observed, respectively, in 25 (15.4%), 61 (37.7%), and 76 (46.9%) patients. Eighty-three (51.2%), 98 (60.5%), and 104 (64.2%) patients had, respectively, large accessory HVs, venous collaterals formed between the HVs, or venous communicating branches between the HV and the peritoneal veins. The middle, left, and right HV was patent in 32 (19.8%), 35 (21.6%), and 44 (27.2%) patients. Recanalization of both hepatic and caval occlusions was successful in 96% (51/53) of those attempted; recanalization of IVC occlusion was successful in 97% (106/109). Among 157 patients successfully treated, 146 were cured and 11 showed clinical improvement. Clinical symptoms were relieved in 82.4% after the initial intervention, and 94.2% after the second intervention. Conclusion: Recanalization and balloon angioplasty was effective for the management of BCS with concurrent HV and IVC occlusions. The majority of patients required only IVC recanalization. The outcome of patients treated only by IVC intervention was similar to that of patients given combined HV and IVC intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗