Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

The Effects of ELDRS at Ultra-Low Dose Rates

We present results on the effects on ELDRS at dose rates of 10, 5, 1, and 0.5 mrad(Si)/s for a variety of radiation hardened and commercial devices. We observed low dose rate enhancement below 10 mrad(Si)/s in several different parts. The magnitudes of the dose rate effects vary. The TL750L, a commercial voltage regulator, showed dose rate dependence in the functional failures, with initial failures occurring after 10 krad(Si) for the parts irradiated at 0.5 mrad(Si)/s. The RH1021 showed an increase in low dose rate enhancement by 2x at 5 mrad(Si)/s relative to 8 mrad(Si)/s and high dose rate, and parametric failure after 100 krad(Si). Additionally the ELDRS-free devices, such as the LM158 and LM117, showed evidence of dose rate sensitivity in parametric degradations. Several other parts also displayed dose rate enhancement, with relatively lower degradations up to approx.15 to 20 krad(Si). The magnitudes of the dose rate enhancement will likely increase in significance at higher total dose levels.

Chen, Dakai↗

Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite

The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ and effective dose rate coefficients for submersion exposure in occupational settings

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.

61 RADIATION PROTECTION AND DOSIMETRY↗

Alteration of cytokine profiles in mice exposed to chronic low-dose ionizing radiation

While a high-dose of ionizing radiation is generally harmful and causes damage to living organisms, a low-dose of radiation has been shown to be beneficial in a variety of animal models. To understand the basis for the effect of low-dose radiation in vivo, we examined the cellular and immunological changes evoked in mice exposed to low-dose radiation at very low (0.7 mGy/h) and low (3.95 mGy/h) dose rate for the total dose of 0.2 and 2 Gy, respectively. Mice exposed to low-dose radiation, either at very low- or low-dose rate, demonstrated normal range of body weight and complete blood counts. Likewise, the number and percentage of peripheral lymphocyte populations, CD4{sup +} T, CD8{sup +} T, B, or NK cells, stayed unchanged following irradiation. Nonetheless, the sera from these mice exhibited elevated levels of IL-3, IL-4, leptin, MCP-1, MCP-5, MIP-1{alpha}, thrombopoietin, and VEGF along with slight reduction of IL-12p70, IL-13, IL-17, and IFN-{gamma}. This pattern of cytokine release suggests the stimulation of innate immunity facilitating myeloid differentiation and activation while suppressing pro-inflammatory responses and promoting differentiation of naive T cells into T-helper 2, not T-helper 1, types. Collectively, our data highlight the subtle changes of cytokine milieu by chronic low-dose {gamma}-radiation, which may be associated with the functional benefits observed in various experimental models.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Prospective Evaluation to Establish a Dose Response for Clinical Oral Mucositis in Patients Undergoing Head-and-Neck Conformal Radiotherapy

Purpose: We conducted a clinical study to correlate oral cavity dose with clinical mucositis, perform in vivo dosimetry, and determine the feasibility of obtaining buccal mucosal cell samples in patients undergoing head-and-neck radiation therapy. The main objective is to establish a quantitative dose response for clinical oral mucositis. Methods and Materials: Twelve patients undergoing radiation therapy for head-and-neck cancer were prospectively studied. Four points were chosen in separate quadrants of the oral cavity. Calculated dose distributions were generated by using AcQPlan and Eclipse treatment planning systems. MOSFET dosimeters were used to measure dose at each sampled point. Each patient underwent buccal sampling for future RNA analysis before and after the first radiation treatment at the four selected points. Clinical and functional mucositis were assessed weekly according to National Cancer Institute Common Toxicity Criteria, Version 3. Results: Maximum and average doses for sampled sites ranged from 7.4-62.3 and 3.0-54.3 Gy, respectively. A cumulative point dose of 39.1 Gy resulted in mucositis for 3 weeks or longer. Mild severity (Grade {<=} 1) and short duration ({<=}1 week) of mucositis were found at cumulative point doses less than 32 Gy. Polymerase chain reaction consistently was able to detect basal levels of two known radiation responsive genes. Conclusions: In our sample, cumulative doses to the oral cavity of less than 32 Gy were associated with minimal acute mucositis. A dose greater than 39 Gy was associated with longer duration of mucositis. Our technique for sampling buccal mucosa yielded sufficient cells for RNA analysis using polymerase chain reaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Effects After Radiotherapy for Locally Advanced Cervical Cancer: Comparison of Two Brachytherapy Schedules and Effect of Dose Delivered Weekly

Purpose: To compare the severe late effects (Grade 3 or greater) for two groups of cervical cancer patients treated with the same external beam radiotherapy and two high-dose-rate intracavitary brachytherapy regimens and to investigate the influence of the dose delivered each week. Methods and Materials: For 120 patients, intracavitary brachytherapy was delivered with 33.6 Gy in eight fractions to Point A (HD group), and for 119, intracavitary brachytherapy was delivered with 29.4 Gy in seven fractions to Point A (LD group). The cumulative incidence of severe gastrointestinal and genitourinary late effects were calculated for both dose groups using Kaplan-Meier survival analysis. This method was also used to explore whether the number of weeks with different dose levels could predict the cumulative incidence of late effects. Results: The actuarial rate of developing severe gastrointestinal morbidity at 7 years was 10.7% and 8.3% for HD and LD groups, respectively. The rate for genitourinary morbidity was 6.6% for the HD group and 5.0% for the LD group, respectively. No significant difference was found between the two groups. The analyses showed that a marginally significant increase occurred in severe gastrointestinal complications as the number of weeks with a physical dose >20 Gy increased in the HD group (p = .047). Conclusion: To establish dose-response relationships for late complications, three-dimensional imaging and dose-volume histogram parameters are needed. We found some indications that 20 Gy/wk is an upper tolerance level when the dose to the International Commission on Radiation Units and Measurements rectum point is 81 Gy{sub {alpha}/{beta}=3} (isoeffective [equivalent] dose of 2-Gy fractions). However, additional investigations using three-dimensional data are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Translational and Rotational Errors on Complex Dose Distributions With Off-Line and On-Line Position Verification

Purpose: To investigate the influence of translational and rotational errors on prostate intensity-modulated radiotherapy (IMRT) with an integrated boost to the tumor and to evaluate the effect of the use of an on-line correction protocol. Methods and Materials: For 19 patients, who had been treated with prostate IMRT and fiducial marker-based position verification, highly inhomogeneous IMRT plans, including an integrated tumor boost, were made using varying margins (2, 4, 6, and 8 mm). The measured translational and rotational errors were used to calculate the dose using two positioning strategies: an off-line and an on-line protocol to correct the translational shifts. The estimated dose to the targets and the organs at risk was compared with the intended dose. Results: Residual deviations after off-line correction led to statistically significant, but very small, reductions in dose coverage. Even when a 2-mm margin was used, the average reduction in dose to 99% of the volume was 1.4 {+-} 1.9 Gy for the tumor, 1.5 {+-} 1.5 Gy for the prostate without seminal vesicles (boost volume), and 4.3 {+-} 4.6 Gy, including the seminal vesicles (clinical target volume). Patients with large systematic rotational errors demonstrated a substantial decrease in dose, especially for the clinical target volume. If an on-line correction protocol was used, the average mean dose and dose to 99% of the volume of the targets improved. However, the extensive dose reduction for patients with large rotational errors barely recovered with on-line correction. Conclusion: For complex prostate IMRT with an integrated tumor boost, the use of an on-line correction protocol yields little improvement without the correction of rotational errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Application of High-Dose, Image-Guided Intensity-Modulated Radiotherapy in High-Risk Prostate Cancer

Purpose: To report the feasibility and early toxicity of dose-escalated image-guided IMRT to the pelvic lymph nodes (LN), prostate (P), and seminal vesicles (SV). Methods and Materials: A total of 103 high-risk prostate cancer patients received two-phase, dose-escalated, image-guided IMRT with 3 years of androgen deprivation therapy. Clinical target volumes (CTVs) were delineated using computed tomography/magnetic resonance co-registration and included the prostate, portions of the SV, and the LN. Planning target volume margins (PTV) used were as follows: P (10 mm, 7 mm posteriorly), SV (10 mm), and LN (5 mm). Organs at risk (OaR) were the rectal and bladder walls, femoral heads, and large and small bowel. The IMRT was planned with an intended dose of 55.1 Gy in 29 fractions to all CTVs (Phase 1), with P+SV consecutive boost of 24.7 Gy in 13 fractions. Daily online image guidance was performed using bony landmarks and intraprostatic markers. Feasibility criteria included delivery of intended doses in 80% of patients, 95% of CTV displacements incorporated within PTV during Phase 1, and acute toxicity rate comparable to that of lower-dose pelvic techniques. Results: A total of 91 patients (88%) received the total prescription dose. All patients received at least 72 Gy. In Phase 1, 63 patients (61%) received the intended 55.1 Gy, whereas 87% of patients received at least 50 Gy. Dose reductions were caused by small bowel and rectal wall constraints. All CTVs received the planned dose in >95% of treatment fractions. There were no Radiation Therapy Oncology Group acute toxicities greater than Grade 3, although there were five incidences equivalent to Grade 3 within a median follow-up of 23 months. Conclusion: These results suggest that dose escalation to the PLN+P+SV using IMRT is feasible, with acceptable rates of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Methods to Reduce Dose to Swallowing-Related Structures in Head and Neck Cancer

Introduction: Emerging data suggest that reduction of dose to the larynx and pharyngeal constrictor may lower the risk of swallowing complications such as long-term gastrostomy dependence and aspiration. Organ avoidance becomes difficult when the primary tumor or involved nodes are present at the level of the larynx. Materials and Methods: Fifteen patients with Stage III-IV squamous cell carcinoma of the head and neck with high-dose target volume at the level of the larynx (but not involving the glottic larynx) were planned with whole-field IMRT (WF-IMRT), as well as a low anterior neck field dynamically matched to an IMRT plan (D-SCLV). Plans were compared with respect to coverage of targets and sparing of normal tissues including the larynx, inferior pharyngeal constrictor (IPC), parotid, and cord. Results: There was no significant difference between the two techniques in coverage of the high- or intermediate-dose planning target volumes (PTVs). Coverage of the elective nodal PTV was inferior with the D-SCLV technique, with a mean of 96.5% vs. 86.3% of the volume receiving the prescription dose (p = 0.001) compared with WF-IMRT plans. However, the D-SCLV technique significantly reduced mean dose to the larynx (43.7 vs. 46.7 Gy, p = 0.05) and IPC (39.1 vs. 46.1 Gy, p = 0.002). There was no significant difference in dose to the parotid or cord. Conclusion: Given the steep dose responses seen in studies examining the association between swallowing toxicity and dose to the larynx and IPC, dose reductions using the D-SCLV technique may be clinically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary Obstruction in Prostate Cancer Patients From the Dutch Trial (68 Gy vs. 78 Gy): Relationships With Local Dose, Acute Effects, and Baseline Characteristics

Purpose: To investigate the relationship between late urinary obstruction and the details of the dose distribution of irradiated prostate cancer patients, taking into account their baseline symptoms and acute complaints. Patients and Methods: We selected patients from the Dutch multicenter trial randomized between 68 Gy and 78 Gy, for whom toxicity data and dose data were available (n = 557). The absolute dose surface parameters of the delineated bladder were calculated. Next, we constructed three-dimensional dose maps of the area around the prostate, providing an approximate identification of the corresponding anatomic locations. The dose difference maps were constructed by subtracting the mean dose maps of the patients with and without late urinary obstruction. Selected local dose points were analyzed using Cox regression analysis. Results: Urinary obstruction was scored for 40 patients, including 19 of 296 patients who received 68-72 Gy and 21 of 261 patients who received 76-78 Gy. A total of 19 events occurred within 2 years after irradiation and 21 events after 2 years. The bladder surface receiving {>=}80 Gy predicted (p <.01) the occurrence of obstruction within 2 years. The dose difference map indicated highly significant differences in the bladder neck situated in the trigonal region (p < .001) that were especially predictive of obstruction after 2 years and of the diagnosis of bladder neck obstruction. Baseline complaints and transurethral resection of the prostate and acute complaints were mainly predictive for obstruction within 2 years. Conclusion: Relatively early events of urinary obstruction were associated with urinary problems existing before RT, acute toxicity, previous transurethral resection of the prostate, and hotspots in the bladder. Events after 2 years were associated with the local dose in the trigonal area.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prescription Dose Guideline Based on Physical Criterion for Multiple Metastatic Brain Tumors Treated With Stereotactic Radiosurgery

Purpose: Existing dose guidelines for intracranial stereotactic radiosurgery (SRS) are primarily based on single-target treatment data. This study investigated dose guidelines for multiple targets treated with SRS. Methods and Materials: A physical model was developed to relate the peripheral isodose volume dependence on an increasing number of targets and prescription dose per target. The model was derived from simulated and clinical multiple brain metastatic cases treated with the Leksell Gamma Knife Perfexion at several institutions, where the total number of targets ranged from 2 to 60. The relative increase in peripheral isodose volumes, such as the 12-Gy volume, was studied in the multitarget treatment setting based on Radiation Therapy Oncology Group 90-05 study dose levels. Results: A significant increase in the 12-Gy peripheral isodose volumes was found in comparing multiple target SRS to single-target SRS. This increase strongly correlated (R{sup 2} = 0.92) with the total number of targets but not the total target volumes (R{sup 2} = 0.06). On the basis of the correlated curve, the 12-Gy volume for multiple target treatment was found to increase by approximately 1% per target when a low target dose such as 15 Gy was used, but approximately 4% per target when a high dose such as 20-24 Gy was used. Reduction in the prescription dose was quantified for each prescription level in maintaining the 12-Gy volume. Conclusion: Normal brain dose increases predictably with increasing number of targets for multitarget SRS. A reduction of approximately 1-2 Gy in the prescribed dose is needed compared with single target radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Bone Marrow Radiation Dose on Acute Hematologic Toxicity in Cervical Cancer: Principal Component Analysis on High Dimensional Data

Purpose: To study the effects of increasing pelvic bone marrow (BM) radiation dose on acute hematologic toxicity in patients undergoing chemoradiotherapy, using a novel modeling approach to preserve the local spatial dose information. Methods and Materials: The study included 37 cervical cancer patients treated with concurrent weekly cisplatin and pelvic radiation therapy. The white blood cell count nadir during treatment was used as the indicator for acute hematologic toxicity. Pelvic BM radiation dose distributions were standardized across patients by registering the pelvic BM volumes to a common template, followed by dose remapping using deformable image registration, resulting in a dose array. Principal component (PC) analysis was applied to the dose array, and the significant eigenvectors were identified by linear regression on the PCs. The coefficients for PC regression and significant eigenvectors were represented in three dimensions to identify critical BM subregions where dose accumulation is associated with hematologic toxicity. Results: We identified five PCs associated with acute hematologic toxicity. PC analysis regression modeling explained a high proportion of the variation in acute hematologicity (adjusted R{sup 2}, 0.49). Three-dimensional rendering of a linear combination of the significant eigenvectors revealed patterns consistent with anatomical distributions of hematopoietically active BM. Conclusions: We have developed a novel approach that preserves spatial dose information to model effects of radiation dose on toxicity, which may be useful in optimizing radiation techniques to avoid critical subregions of normal tissues. Further validation of this approach in a large cohort is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Trials of a Urethral Dose Measurement System in Brachytherapy Using Scintillation Detectors

Purpose: To report on the clinical feasibility of a novel scintillation detector system with fiberoptic readout that measures the urethral dose during high-dose-rate brachytherapy treatment of the prostate. Methods and Materials: The clinical trial enrolled 24 patients receiving high-dose-rate brachytherapy treatment to the prostate. After the first 14 patients, three improvements were made to the dosimeter system design to improve clinical reliability: a dosimeter self-checking facility; a radiopaque marker to determine the position of the dosimeter, and a more robust optical extension fiber. Results: Improvements to the system design allowed for accurate dose measurements to be made in vivo. A maximum measured dose departure of 9% from the calculated dose was observed after dosimeter design improvements. Conclusions: Departures of the measured from the calculated dose, after improvements to the dosimetry system, arise primarily from small changes in patient anatomy. Therefore, we recommend that patient response be correlated with the measured in vivo dose rather than with the calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parameters Favorable to Intraprostatic Radiation Dose Escalation in Men With Localized Prostate Cancer

Purpose: To identify , within the framework of a current Phase I trial, whether factors related to intraprostatic cancer lesions (IPLs) or individual patients predict the feasibility of high-dose intraprostatic irradiation. Methods and Materials: Endorectal coil MRI scans of the prostate from 42 men were evaluated for dominant IPLs. The IPLs, prostate, and critical normal tissues were contoured. Intensity-modulated radiotherapy plans were generated with the goal of delivering 75.6 Gy in 1.8-Gy fractions to the prostate, with IPLs receiving a simultaneous integrated boost of 3.6 Gy per fraction to a total dose of 151.2 Gy, 200% of the prescribed dose and the highest dose cohort in our trial. Rectal and bladder dose constraints were consistent with those outlined in current Radiation Therapy Oncology Group protocols. Results: Dominant IPLs were identified in 24 patients (57.1%). Simultaneous integrated boosts (SIB) to 200% of the prescribed dose were achieved in 12 of the 24 patients without violating dose constraints. Both the distance between the IPL and rectum and the hip-to-hip patient width on planning CT scans were associated with the feasibility to plan an SIB (p = 0.002 and p = 0.0137, respectively). Conclusions: On the basis of this small cohort, the distance between an intraprostatic lesion and the rectum most strongly predicted the ability to plan high-dose radiation to a dominant intraprostatic lesion. High-dose SIB planning seems possible for select intraprostatic lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Should Patient Setup in Lung Cancer Be Based on the Primary Tumor? An Analysis of Tumor Coverage and Normal Tissue Dose Using Repeated Positron Emission Tomography/Computed Tomography Imaging

Purpose: Evaluation of the dose distribution for lung cancer patients using a patient setup procedure based on the bony anatomy or the primary tumor. Methods and materials: For 39 patients with non-small-cell lung cancer, the planning fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scan was registered to a repeated FDG-PET/CT scan made in the second week of treatment. Two patient setup methods were analyzed based on the bony anatomy or the primary tumor. The original treatment plan was copied to the repeated scan, and target and normal tissue structures were delineated. Dose distributions were analyzed using dose-volume histograms for the primary tumor, lymph nodes, lungs, and spinal cord. Results: One patient showed decreased dose coverage of the primary tumor caused by progressive disease and required replanning to achieve adequate coverage. For the other patients, the minimum dose to the primary tumor did not significantly deviate from the planned dose: -0.2 {+-} 1.7% (p = 0.71) and -0.1 {+-} 1.7% (p = 0.85) for the bony anatomy setup and the primary tumor setup, respectively. For patients (n = 31) with nodal involvement, 10% showed a decrease in minimum dose larger than 5% for the bony anatomy setup and 13% for the primary tumor setup. The mean lung dose exceeded the maximum allowed 20 Gy in 21% of the patients for the bony anatomy setup and in 13% for the primary tumor setup, whereas for the spinal cord this occurred in 10% and 13% of the patients, respectively. Conclusions: In 10% and 13% of patients with nodal involvement, setup based on bony anatomy or primary tumor, respectively, led to important dose deviations in nodal target volumes. Overdosage of critical structures occurred in 10-20% of the patients. In cases of progressive disease, repeated imaging revealed underdosage of the primary tumor. Development of practical ways for setup procedures based on repeated high-quality imaging of all tumor sites during radiotherapy should therefore be an important research focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Associated With Chest Wall Toxicity After Accelerated Partial Breast Irradiation Using High-Dose-Rate Brachytherapy

Purpose: The purpose of this analysis was to evaluate dose-volume relationships associated with a higher probability for developing chest wall toxicity (pain) after accelerated partial breast irradiation (APBI) by using both single-lumen and multilumen brachytherapy. Methods and Materials: Rib dose data were available for 89 patients treated with APBI and were correlated with the development of chest wall/rib pain at any point after treatment. Ribs were contoured on computed tomography planning scans, and rib dose-volume histograms (DVH) along with histograms for other structures were constructed. Rib DVH data for all patients were sampled at all volumes {>=}0.008 cubic centimeter (cc) (for maximum dose related to pain) and at volumes of 0.5, 1, 2, and 3 cc for analysis. Rib pain was evaluated at each follow-up visit. Patient responses were marked as yes or no. No attempt was made to grade responses. Eighty-nine responses were available for this analysis. Results: Nineteen patients (21.3%) complained of transient chest wall/rib pain at any point in follow-up. Analysis showed a direct correlation between total dose received and volume of rib irradiated with the probability of developing rib/chest wall pain at any point after follow-up. The median maximum dose at volumes {>=}0.008 cc of rib in patients who experienced chest wall pain was 132% of the prescribed dose versus 95% of the prescribed dose in those patients who did not experience pain (p = 0.0035). Conclusions: Although the incidence of chest wall/rib pain is quite low with APBI brachytherapy, attempts should be made to keep the volume of rib irradiated at a minimum and the maximum dose received by the chest wall as low as reasonably achievable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗