Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Development of a Microchannel Plate-Based Gated X-ray Imager for Imaging and Spectroscopy Experiments on Z

This poster describes a microchannelplate (MCP)–based, gated x-ray imager developed by National Security Technologies, LLC (NSTec), and Sandia National Laboratories(SNL) over the past several years. The camera consists of a 40 mm × 40 mm MCP, coated with eight 4 mm wide microstrips. The camera is gated by sending subnanosecond high-voltage pulses across the striplines. We have performed an extensive characterization of the camera, the results of which we present here. The camera has an optical gate profile width (time resolution) as narrow as 150 ps and detector uniformity of better than 30% along the length of a strip, far superior than what was achieved in previous designs. The spatial resolution is on the order of 40 microns for imaging applications and a dynamic range of between ~100 and ~1000. We also present results from a Monte Carlo simulation code developed by NSTec over the last several years. Agreement between the simulation results and the experimental measurements is very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microchip and wedge ion funnels and planar ion beam analyzers using same

Electrodynamic ion funnels confine, guide, or focus ions in gases using the Dehmelt potential of oscillatory electric field. New funnel designs operating at or close to atmospheric gas pressure are described. Effective ion focusing at such pressures is enabled by fields of extreme amplitude and frequency, allowed in microscopic gaps that have much higher electrical breakdown thresholds in any gas than the macroscopic gaps of present funnels. The new microscopic-gap funnels are useful for interfacing atmospheric-pressure ionization sources to mass spectrometry (MS) and ion mobility separation (IMS) stages including differential IMS or FAIMS, as well as IMS and MS stages in various configurations. In particular, "wedge" funnels comprising two planar surfaces positioned at an angle and wedge funnel traps derived therefrom can compress ion beams in one dimension, producing narrow belt-shaped beams and laterally elongated cuboid packets. This beam profile reduces the ion density and thus space-charge effects, mitigating the adverse impact thereof on the resolving power, measurement accuracy, and dynamic range of MS and IMS analyzers, while a greater overlap with coplanar light or particle beams can benefit spectroscopic methods.

47 OTHER INSTRUMENTATION↗

Radar echo processing with partitioned de-ramp

The spurious-free dynamic range of a wideband radar system is increased by apportioning de-ramp processing across analog and digital processing domains. A chirp rate offset is applied between the received waveform and the reference waveform that is used for downconversion to the intermediate frequency (IF) range. The chirp rate offset results in a residual chirp in the IF signal prior to digitization. After digitization, the residual IF chirp is removed with digital signal processing.

47 OTHER INSTRUMENTATION↗

BEAM INSTRUMENTATION FOR HIGH POWER HADRON BEAMS

This presentation will describe developments in the beam diagnostics which support the understanding and operation of high power hadron accelerators. These include the measurement of large dynamic range transverse and longitudinal beam profiles, beam loss detection, and non-interceptive diagnostics.

Aleksandrov, Alexander V↗

Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Label-free functional nucleic acid sensors for detecting target agents

A general methodology to design label-free fluorescent functional nucleic acid sensors using a vacant site approach and an abasic site approach is described. In one example, a method for designing label-free fluorescent functional nucleic acid sensors (e.g., those that include a DNAzyme, aptamer or aptazyme) that have a tunable dynamic range through the introduction of an abasic site (e.g., dSpacer) or a vacant site into the functional nucleic acids. Also provided is a general method for designing label-free fluorescent aptamer sensors based on the regulation of malachite green (MG) fluorescence. A general method for designing label-free fluorescent catalytic and molecular beacons (CAMBs) is also provided. The methods demonstrated here can be used to design many other label-free fluorescent sensors to detect a wide range of analytes. Sensors and methods of using the disclosed sensors are also provided.

59 BASIC BIOLOGICAL SCIENCES↗

Summary of the 2014 Beam-Halo Monitoring Workshop

Understanding and controlling beam halo is important for high-intensity hadron accelerators, for high-brightness electron linacs, and for low-emittance light sources. This can only be achieved by developing suitable diagnostics. The main challenge faced by such instrumentation is the high dynamic range needed to observe the halo in the presence of an intense core. In addition, measurements must often be made non-invasively. This talk summarizes the one-day workshop on Beam-Halo Monitoring that was held at SLAC on September 19 last year, immediately following IBIC 2014 in Monterey. Workshop presentations described invasive techniques using wires, screens, or crystal collimators, and non-invasive measurements with gas or scattered electrons. Talks on optical methods showed the close links between observing halo and astronomical problems like observing the solar corona or directly observing a planet orbiting another star.

43 PARTICLE ACCELERATORS↗

Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

43 PARTICLE ACCELERATORS↗

Optical synchrotron radiation beam imaging with a digital mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

43 PARTICLE ACCELERATORS↗

Seismic SMHD -- Rotational Sensor Development and Deployment

The U.S. Department of Energy (DOE) and Applied Technology Associates (ATA) are funding development and deployment of a new generation of rotational sensors for validation of rotational seismic applications. The sensors employ Magnetohydrodynamic (MHD) principles with broadband response, high dynamic range, low noise floor, proven ruggedness, and high repeatability. This paper presents current status of sensor development and deployment opportunities.

58 GEOSCIENCES↗

Universal Number Library

This floating-point arithmetic library contains a software implementation of Universal Numbers (unums) as described by John Gustafson [1]. The unum format is a superset of IEEE 754 floating point with several advantages. Computing with unums provides more accurate answers without rounding errors, underflow or overflow. In contrast to fixed-sized IEEE numbers, a variable number of bits can be used to encode unums. This all allows number with only a few significant digits or with a small dynamic range to be represented more compactly.

Lloyd, G. Scott↗

Validation of the Five-Phase Method for Simulating Complex Fenestration Systems with Radiance against Field Measurements

The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indices derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-aperture optical system for high-resolution imaging

Technologies pertaining to a multi-aperture optical imaging system are described herein. The multi-aperture optical system comprises an afocal optical telescope and a plurality of sub-apertures that receive light from the telescope. Each sub-aperture comprises a focusing optic that creates a full-field image onto an individual image sensor that outputs data indicative of an intensity of light received at the sensor. Image processing techniques can be used to combine the sensor outputs for spectral discrimination, to improve dynamic range or to enhance resolution of a scene.

47 OTHER INSTRUMENTATION↗

Miniaturized lateral flow device for rapid and sensitive detection of proteins or nucleic acids

The invention provides miniaturized lateral flow chromatographic and lateral flow chromatographic microarray devices (LFM). The miniaturization of lateral flow nucleic acid detection achieved by the present invention offers reduced reagent use, femtomole sensitivity, excellent linear dynamic range, and rapid detection. Moreover, the small feature sizes of capture oligonucleotides renders the potential information capacity of the platform comparable to more traditional spotted fluorescence microarrays as well as improving sensitivity. The LFM devices exemplified herein enable analytes to be detected within 10 seconds from the time of sample introduction to the LFM device. Sample volumes may be as low as about 10 microliters, significantly reducing assay costs and ameliorating reagent storage logistics. Additionally, the miniaturization of lateral flow opens the door to highly multiplexed assays, allowing many proteins or nucleic acids to be detected in a single assay.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wavefront detector

A wavefront sensor system suitable for integration into an integrated circuit light detector may provide for wave angle sensors having varying functional relationships between the wave angle and signal to provide improved dynamic range. These wave angle sensors may be combined with integrated circuit phase angle sensors for a more complete analysis of the waveform.

42 ENGINEERING↗

Optical array for high-quality imaging in harsh environments

Methods and apparatus are disclosed for producing high quality images in uncontrolled or impaired environments. In some examples of the disclosed technology, groups of cameras for high dynamic range (HDR), polarization diversity, and optional other diversity modes are arranged to concurrently image a common scene. For example, in a vehicle checkpoint application, HDR provides discernment of dark objects inside a vehicle, while polarization diversity aids in rejecting glare. Spectral diversity, infrared imaging, and active illumination can be applied for better imaging through a windshield. Preprocessed single-camera images are registered and fused. Faces or other features of interest can be detected in the fused image and identified in a library. Impairments can include weather, insufficient or interfering lighting, shadows, reflections, window glass, occlusions, or moving objects.

42 ENGINEERING↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗