Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may increase the level of care.

Hurst, Victor, IV↗

Aftertreatment protocols for catalyst characterization and performance evaluation: low-temperature oxidation, storage, three-way, and NH3-SCR catalyst test protocols

A set of standardized and realistic aftertreatment catalyst test protocols have been developed by the Advanced Combustion and Emission Control Technical Team in support of the U.S.DRIVE Partnership. The protocols are intended to accelerate the pace of aftertreatment catalyst innovation by enabling the accurate evaluation and comparison of aftertreatment catalyst performance data from various testing and research facilities to maximize the impact of discovery-phase research occurring across the nation. The protocols address a need identified by the Partnership’s industry partners for consistent and accurate metrics for aftertreatment catalyst evaluation and comparison. The protocols consist of a set of standardized requirements and test procedures that sufficiently capture the performance capability of a catalyst technology in a manner that is adaptable in various laboratories. The protocols provide a detailed description of the necessary reactor system, the steps for achieving a desired aged state of the catalyst, all necessary sample pretreatment to be performed prior to testing, and realistic test conditions for evaluating performance. This article details four low-temperature catalyst test protocols applicable to (1) oxidation catalysts, (2) passive storage (and release) catalysts, (3) three-way catalysts, and (4) NH3-SCR catalysts. The catalyst test protocol descriptions are presented in five (5) sections: protocol general guidelines and the four individual catalyst test protocol descriptions. The general guidelines plus the individual protocol description forms the complete low-temperature catalyst test protocol for the application.

Emission control, Three-way catalyst, oxidation, S↗

A protocol for lifetime energy and environmental impact assessment of building insulation materials

This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist, which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined.

54 ENVIRONMENTAL SCIENCES↗

International Patterns of Practice in the Management of Radiation Therapy-induced Nausea and Vomiting

Purpose: To investigate international patterns of practice in the management of radiation therapy-induced nausea and vomiting (RINV). Methods and Materials: Oncologists prescribing radiation therapy in the United States, Canada, The Netherlands, Australia, New Zealand, Spain, Italy, France, Hong Kong, Singapore, Cyprus, and Israel completed a Web-based survey that was based on 6 radiation therapy-only clinical cases modeled after the minimal-, low-, moderate-, and high-emetic risk levels defined in the antiemetic guidelines of the American Society of Clinical Oncology and the Multinational Association of Supportive Care in Cancer. For each case, respondents estimated the risks of nausea and vomiting separately and committed to an initial management approach. Results: In total, 1022 responses were received. Risk estimates and management decisions for the minimal- and high-risk cases varied little and were in line with guideline standards, whereas those for the low- and moderate-risk cases varied greatly. The most common initial management strategies were as follows: rescue therapy for a minimal-risk case (63% of respondents), 2 low-risk cases (56% and 80%), and 1 moderate-risk case (66%); and prophylactic therapy for a second moderate-risk case (75%) and a high-risk case (95%). The serotonin (5-HT){sub 3} receptor antagonists were the most commonly recommended prophylactic agents. On multivariate analysis, factors predictive of a decision for prophylactic or rescue therapy were risk estimates of nausea and vomiting, awareness of the American Society of Clinical Oncology antiemetic guideline, and European Society for Therapeutic Radiology and Oncology membership. Conclusions: Risk estimates and management strategies for RINV varied, especially for low- and moderate-risk radiation therapy cases. Radiation therapy-induced nausea and vomiting are under-studied treatment sequelae. New observational and translational studies are needed to allow for individual patient risk assessment and to refine antiemetic guideline management recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Naturally-Occurring Radionuclides In Drinking Water From Surface And Groundwater Reservoirs

Radioactivity in water for human consumption is under closer scrutiny than ever before and many countries adopted guideline values based on total alpha and total beta activity measurements. Although most waters from surface circulation meet these guidelines, it is frequently found that groundwater exceed guideline values. Results of water analyses by alpha spectrometry clarified that the main radionuclides present are from the uranium decay series, such as uranium isotopes, radium ({sup 226}Ra), radon ({sup 222}Rn), and also {sup 210}Pb and {sup 210}Po. Occasionally, groundwater displayed {sup 226}Ra concentrations higher than 1 Bq L{sup -1} and {sup 222}Rn concentrations above 1000 Bq L{sup -1}. Nevertheless, lack of conformity of these waters with guidelines adopted, generally, is not due to anthropogenic inputs.

54 ENVIRONMENTAL SCIENCES↗

guideline36_conformance_test 0.1

The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) has established a set of standardized high performance sequences of operation for Heating, Ventilation and Air Conditioning (HVAC) systems in buildings through their "Guideline 36". In order to achieve the intended performance, these sequences must be translated and programmed accurately in the Building Automation System (BAS) controllers. Standardizing these sequences will allow for a more efficient product delivery mechanism where the sequences are programmed and tested centrally by each manufacturer, and then distributed to their dealers/engineering contractors. This approach would minimize the need for each installer to re-interpret and program the sequences, reduces risk of errors, and reduces the time required for commissioning in the field. To achieve this goal, a performance validation method is needed to provide independent confirmation that each manufacturer has programmed the Guideline 36 sequences accurately. A standardized method of test would also avoid the need for manual interpretation (and the associated human variability) that is required with typical functional testing approaches by automating the inputs and the range of expected responses. This software "guideline36_conformance_test" has been developed to conduct standardized, repeatable and manufacturer independent tests to validate that a BAS controller has been programmed in conformance with Guideline 36. Manufacturers would provide the controller (or the control program) and the software would run a suite of tests by setting a set of inputs to the controller and verifying the output signals from the controller matches the expected output as set by Guideline 36.

Pritoni, Marco↗

Data Sharing Report for the Quantification of Removable Activity in Various Surveillance and Maintenance Facilities at the Oak Ridge National Laboratory Oak Ridge TN

The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (OR-EM) requested that Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, provide technical and independent waste management planning support using American Recovery and Reinvestment Act (ARRA) funds. Specifically, DOE OR-EM requested that ORAU plan and implement a sampling and analysis campaign targeting potential removable radiological contamination that may be transferrable to future personal protective equipment (PPE) and contamination control materials—collectively referred to as PPE throughout the remainder of this report—used in certain URS|CH2M Oak Ridge, LLC (UCOR) Surveillance and Maintenance (S&M) Project facilities at the Oak Ridge National Laboratory (ORNL). Routine surveys in Bldgs. 3001, 3005, 3010, 3028, 3029, 3038, 3042, 3517, 4507, and 7500 continuously generate PPE. The waste is comprised of Tyvek coveralls, gloves, booties, Herculite, and other materials used to prevent worker exposure or the spread of contamination during routine maintenance and monitoring activities. This report describes the effort to collect and quantify removable activity that may be used by the ORNL S&M Project team to develop radiation instrumentation “screening criteria.” Material potentially containing removable activity was collected on smears, including both masselin large-area wipes (LAWs) and standard paper smears, and analyzed for site-related constituents (SRCs) in an analytical laboratory. The screening criteria, if approved, may be used to expedite waste disposition of relatively clean PPE. The ultimate objectives of this effort were to: 1) determine whether screening criteria can be developed for these facilities, and 2) provide process knowledge information for future site planners. The screening criteria, if calculated, must be formally approved by Federal Facility Agreement parties prior to use for ORNL S&M Project PPE disposal at the Environmental Management Waste Management Facility (EMWMF). ORAU executed the approved sampling and analysis plan (SAP) (DOE 2013) while closely coordinating with ORNL S&M Project personnel and using guidelines outlined in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012). WHP guidelines were followed because the PPE waste targeted by this SAP is consistent with that addressed under the approved Waste Lot (WL) 108.1 profile for disposal at EMWMF—this PPE is a “future waste stream” as defined in the WHP. The SAP presents sampling strategy and methodology, sample selection guidelines, and analytical guidelines and requirements necessary for characterizing future ORNL S&M Project PPE waste. This report presents a review of the sample and analysis methods including data quality objectives (DQOs), required deviations from the original design, summary of field activities, radiation measurement data, analytical laboratory results, a brief presentation of results, and process knowledge summaries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification of RESRAD-RDD. (Version 2.01)

In this report, the results generated by RESRAD-RDD version 2.01 are compared with those produced by RESRAD-RDD version 1.7 for different scenarios with different sets of input parameters. RESRAD-RDD version 1.7 is spreadsheet-driven, performing calculations with Microsoft Excel spreadsheets. RESRAD-RDD version 2.01 revamped version 1.7 by using command-driven programs designed with Visual Basic.NET to direct calculations with data saved in Microsoft Access database, and re-facing the graphical user interface (GUI) to provide more flexibility and choices in guideline derivation. Because version 1.7 and version 2.01 perform the same calculations, the comparison of their results serves as verification of both versions. The verification covered calculation results for 11 radionuclides included in both versions: Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90. At first, all nuclide-specific data used in both versions were compared to ensure that they are identical. Then generic operational guidelines and measurement-based radiation doses or stay times associated with a specific operational guideline group were calculated with both versions using different sets of input parameters, and the results obtained with the same set of input parameters were compared. A total of 12 sets of input parameters were used for the verification, and the comparison was performed for each operational guideline group, from A to G, sequentially. The verification shows that RESRAD-RDD version 1.7 and RESRAD-RDD version 2.01 generate almost identical results; the slight differences could be attributed to differences in numerical precision with Microsoft Excel and Visual Basic.NET. RESRAD-RDD version 2.01 allows the selection of different units for use in reporting calculation results. The results of SI units were obtained and compared with the base results (in traditional units) used for comparison with version 1.7. The comparison shows that RESRAD-RDD version 2.01 correctly reports calculation results in the unit specified in the GUI.

54 ENVIRONMENTAL SCIENCES↗

Applicability for MELCOR Accident Code System (MACCS) to Model the Atmospheric Transport of Biological Contaminants

Characterization of airborne transmission behavior for biological contaminants is a critical aspect in developing public health guidelines in the event of an outbreak. Guidelines such as safe separation distances and physical protections (mask and face-shields) are heavily influenced by the particular biological airborne transmission risk, which depends on a multitude of factors and is not easily or readily determined, therefore potentially lagging behind the time sensitive need to inform effective public health guidelines. Herein is proposed a means to leverage the substantial investment over the last three decades of the Nuclear Regulatory Commission in the MACCS code suite developed at Sandia National Laboratories. This work includes augmenting the MACCS code to represent biological rather than radioactive contaminants in the atmosphere, therefore characterizing the airborne transmission risk for such contaminants and helping to inform critical and time sensitive public health guidelines.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the NASA Flight Assurance Review Program

The NASA flight assurance review program to develop minimum standard guidelines for flight assurance reviews was assessed. Documents from NASA centers and NASA headquarters to determine current design review practices and procedures were evaluated. Six reviews were identified for the recommended minimum. The practices and procedures used at the different centers to incorporate the most effective ones into the minimum standard review guidelines were analyzed and guidelines for procedures, personnel and responsibilies, review items/data checklist, and feedback and closeout were defined. The six recommended reviews and the minimum standards guidelines developed for flight assurance reviews are presented. Observations and conclusions for further improving the NASA review and quality assurance process are outlined.

Holmes, J.↗

NASA preferred reliability-practices for design and test

NASA HQ established the NASA R&M Steering Committee (R&MSC) comprised of membership from each NASA field center. The primary charter of the R&MSC is to obtain, record, and share the best design practices that NASA has applied to successful space flight programs and current design considerations (guidelines) that should enhance flight reliability on emerging programs. The practices and guidelines are being assembled in a living document for distribution to NASA centers and the aerospace community. The document will be updated annually with additional practices and guidelines as contributions from the centers are reviewed and approved by the R&MSC. Practices and guidelines are not requirements, but rather a means of sharing procedures and techniques that a given center and the R&MSC together feel have strong technical merit and application to the design of space-related equipment.

Lisk, Ronald C.↗

Handbook for handling and storage of nickel-cadmium batteries: Lessons learned

The handbook provides guidelines for the handling and storage of conventional NiCd flight batteries. The guidelines are based on many years of experience with ground and in-flight handling of batteries. The overall goal is to minimize the deterioration and irreversible effects of improper handling of NiCd flight batteries on flight performance. A secondary goal is to provide the reader with an understanding, in nonanalytical terms, of the degradation mechanisms of NiCd cells and how these mechanisms are affected by improper ground handling of flight hardware. Section 2 provides the reader with a brief introduction to NiCd cells. The effects of the environment on NiCd batteries are discussed in Section 3, and Section 4 contains 12 guidelines for battery handling and storage with supporting rationale for each guideline. The appendix provides a synopsis of NiCd cell design and evolution over 30 years of space flight on Goddard Space Flight Center (GSFC) satellites, along with a chronological review of key events that influenced the design of NiCd cells being flown today.

Ford, Floyd E.↗

Software Safety Progress in NASA

NASA has developed guidelines for development and analysis of safety-critical software. These guidelines have been documented in a Guidebook for Safety Critical Software Development and Analysis. The guidelines represent a practical 'how to' approach, to assist software developers and safety analysts in cost effective methods for software safety. They provide guidance in the implementation of the recent NASA Software Safety Standard NSS-1740.13 which was released as 'Interim' version in June 1994, scheduled for formal adoption late 1995. This paper is a survey of the methods in general use, resulting in the NASA guidelines for safety critical software development and analysis.

Radley, Charles F.↗

Visualization of International Solar-Terrestrial Physics Program (ISTP) data

The International Solar-Terrestrial Physics Program (ISTP) is a multispacecraft, multinational program whose objective is to promote further understanding of the Earth's complex plasma environment. Extensive data sharing and data analysis will be needed to ensure the success of the overall ISTP program. For this reason, there has been a special emphasis on data standards throughout ISTP. One of the key tools will be the common data format (CDF), developed, maintained, and evolved at the National Space Science Data Center (NSSDC), with the set of ISTP implementation guidelines specially designed for space physics data sets by the Space Physics Data Facility (associated with the NSSDC). The ISTP guidelines were developed to facilitate searching, plotting, merging, and subsetting of data sets. We focus here on the plotting application. A prototype software package was developed to plot key parameter (KP) data from the ISTP program at the Science Planning and Operations Facility (SPOF). The ISTP Key Parameter Visualization Tool is based on the Interactive Data Language (IDL) and is keyed to the ISTP guidelines, reading data stored in CDF. With the combination of CDF, the ISTP guidelines, and the visualization software, we can look forward to easier and more effective data sharing and use among ISTP scientists.

Kessel, Ramona L.↗

High-Alpha Handling Qualities Flight Research on the NASA F/A-18 High Alpha Research Vehicle

A flight research study of high-angle-of-attack handling qualities has been conducted at the NASA Dryden Flight Research Center using the F/A-18 High Alpha Research Vehicle (HARV). The objectives were to create a high-angle-of-attack handling qualities flight database, develop appropriate research evaluation maneuvers, and evaluate high-angle-of-attack handling qualities guidelines and criteria. Using linear and nonlinear simulations and flight research data, the predictions from each criterion were compared with the pilot ratings and comments. Proposed high-angle-of-attack nonlinear design guidelines and proposed handling qualities criteria and guidelines developed using piloted simulation were considered. Recently formulated time-domain Neal-Smith guidelines were also considered for application to high-angle-of-attack maneuvering. Conventional envelope criteria were evaluated for possible extension to the high-angle-of-attack regime. Additionally, the maneuvers were studied as potential evaluation techniques, including a limited validation of the proposed standard evaluation maneuver set. This paper gives an overview of these research objectives through examples and summarizes result highlights. The maneuver development is described briefly, the criteria evaluation is emphasized with example results given, and a brief discussion of the database form and content is presented.

Keith D Wichman↗

High-Alpha Research Vehicle Lateral-Directional Control Law Description, Analyses, and Simulation Results

This report contains a description of a lateral-directional control law designed for the NASA High-Alpha Research Vehicle (HARV). The HARV is a F/A-18 aircraft modified to include a research flight computer, spin chute, and thrust-vectoring in the pitch and yaw axes. Two separate design tools, CRAFT and Pseudo Controls, were integrated to synthesize the lateral-directional control law. This report contains a description of the lateral-directional control law, analyses, and nonlinear simulation (batch and piloted) results. Linear analysis results include closed-loop eigenvalues, stability margins, robustness to changes in various plant parameters, and servo-elastic frequency responses. Step time responses from nonlinear batch simulation are presented and compared to design guidelines. Piloted simulation task scenarios, task guidelines, and pilot subjective ratings for the various maneuvers are discussed. Linear analysis shows that the control law meets the stability margin guidelines and is robust to stability and control parameter changes. Nonlinear batch simulation analysis shows the control law exhibits good performance and meets most of the design guidelines over the entire range of angle-of-attack. This control law (designated NASA-1A) was flight tested during the Summer of 1994 at NASA Dryden Flight Research Center.

Davidson, John B.↗

Overview of the SAE G-11 RMSL (Reliability, Maintainability, Supportability, and Logistics) Division Activities and Technical Projects

The SAE G-11 RMSL (Reliability, Maintainability, Supportability, and Logistics) Division activities include identification and fulfillment of joint industry, government, and academia needs for development and implementation of RMSL technologies. Four Projects in the Probabilistic Methods area and two in the area of RMSL have been identified. These are: (1) Evaluation of Probabilistic Technology - progress has been made toward the selection of probabilistic application cases. Future effort will focus on assessment of multiple probabilistic softwares in solving selected engineering problems using probabilistic methods. Relevance to Industry & Government - Case studies of typical problems encountering uncertainties, results of solutions to these problems run by different codes, and recommendations on which code is applicable for what problems; (2) Probabilistic Input Preparation - progress has been made in identifying problem cases such as those with no data, little data and sufficient data. Future effort will focus on developing guidelines for preparing input for probabilistic analysis, especially with no or little data. Relevance to Industry & Government - Too often, we get bogged down thinking we need a lot of data before we can quantify uncertainties. Not True. There are ways to do credible probabilistic analysis with little data; (3) Probabilistic Reliability - probabilistic reliability literature search has been completed along with what differentiates it from statistical reliability. Work on computation of reliability based on quantification of uncertainties in primitive variables is in progress. Relevance to Industry & Government - Correct reliability computations both at the component and system level are needed so one can design an item based on its expected usage and life span; (4) Real World Applications of Probabilistic Methods (PM) - A draft of volume 1 comprising aerospace applications has been released. Volume 2, a compilation of real world applications of probabilistic methods with essential information demonstrating application type and timehost savings by the use of probabilistic methods for generic applications is in progress. Relevance to Industry & Government - Too often, we say, 'The Proof is in the Pudding'. With help from many contributors, we hope to produce such a document. Problem is - not too many people are coming forward due to proprietary nature. So, we are asking to document only minimum information including problem description, what method used, did it result in any savings, and how much?; (5) Software Reliability - software reliability concept, program, implementation, guidelines, and standards are being documented. Relevance to Industry & Government - software reliability is a complex issue that must be understood & addressed in all facets of business in industry, government, and other institutions. We address issues, concepts, ways to implement solutions, and guidelines for maximizing software reliability; (6) Maintainability Standards - maintainability/serviceability industry standard/guidelines and industry best practices and methodologies used in performing maintainability/ serviceability tasks are being documented. Relevance to Industry & Government - Any industry or government process, project, and/or tool must be maintained and serviced to realize the life and performance it was designed for. We address issues and develop guidelines for optimum performance & life.

Singhal, Surendra N.↗