Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

ATMOSPHERIC IMAGING ASSEMBLY OBSERVATIONS OF HOT FLARE PLASMA

We present observations of hot plasma from solar eruptions recorded by the Atmospheric Imaging Assembly (AIA) on the Solar Dynamics Observatory. AIA is the first narrowband instrument capable of taking images of hot plasma in the 5-15 MK range. We find that there are hot structures above flare loops, and that they are typically more diffuse and nebulous than the well-defined flare loops. Because of the narrowband response, high sensitivity, and high spatial resolution of AIA, these supra-arcade structures are visible in exquisite detail, particularly in the 131 A and 94 A channels. In one event, a C4.9 flare observed on 2010 November 3, hot plasma is seen to outline an erupting plasmoid and possibly a current sheet. We compare hot plasma observed with AIA to structures observed with the X-Ray Telescope on the Hinode mission and find that the plasma imaged in AIA contains more fine detail. These new AIA observations show that supra-arcade flare structures and coronal mass ejections are highly structured not only in space and time, but also in temperature. This thermal structuring is expected, based on modeling efforts, but has now been imaged directly for the first time over a large range of temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Particle integrity, sampling, and application of a DNA-tagged tracer for aerosol transport studies

Aerosols are an ever-present part of our daily environment and have extensive effects on both human and environmental health. Particles in the inhalable range (1-10 μm diameter) are of particular concern because their deposition in the lung can lead to a variety of illnesses including allergic reactions, viral or bacterial infections, and cancer. Understanding the transport of inhalable aerosols across both short and long distances is necessary to predict human exposures to aerosols. To assess the transport of hazardous aerosols, surrogate tracer particles are required to measure their transport through occupied spaces. These tracer particles must not only possess similar transport characteristics to those of interest but also be easily distinguished from the background at low levels and survive the environmental conditions of the testing environment. A previously-developed DNA-tagged particle (DNATrax), composed of food-grade sugar and a DNA oligonucleotide as a “barcode” label, shows promise as a new aerosol tracer. Herein, the use of DNATrax material is validated for use in both indoor and outdoor environments. Utilizing passive samplers made of materials commonly found in indoor environments followed by quantitative polymerase chain reaction (qPCR) assay for endpoint particle detection, particles detection was achieved up to 90 m from the aerosolization location and across shorter distances with high spatial resolution. The unique DNA label and PCR assay specificity were leveraged to perform multiple simultaneous experiments. This allowed the assessment of experimental reproducibility, a rare occurrence among aerosol field tests. To transition to outdoor testing, the solid material provides some protection of the DNA label when exposed to ultraviolet (UV) radiation, with 60% of the DNA remaining intact after 60 minutes under a germicidal lamp and the rate of degradation declining with irradiation time. Additionally, exposure of the DNATrax material using formulations of two different food-grade sugars (maltodextrin and erythritol) to humidity as high as 66% had no significant effect on the DNA label’s degradation or the particle’s aerodynamic diameter, confirming particle stability under such conditions. In summary, confirmation of the DNATrax particles’ size and label integrity under variable conditions combined with experiment multiplexing and high resolution sampling provides a powerful experimental design for modeling aerosol transport through occupied indoor and outdoor locations.

54 ENVIRONMENTAL SCIENCES↗

Spaceborne Microwave Instrument for High Resolution Remote Sensing of the Earth's Surface Using a Large-Aperture Mesh Antenna

This report describes a two-year study of a large-aperture, lightweight, deployable mesh antenna system for radiometer and radar remote sensing of the Earth from space. The study focused specifically on an instrument to measure ocean salinity and Soil moisture. Measurements of ocean salinity and soil moisture are of critical . importance in improving knowledge and prediction of key ocean and land surface processes, but are not currently obtainable from space. A mission using this instrument would be the first demonstration of deployable mesh antenna technology for remote sensing and could lead to potential applications in other remote sensing disciplines that require high spatial resolution measurements. The study concept features a rotating 6-m-diameter deployable mesh antenna, with radiometer and radar sensors, to measure microwave emission and backscatter from the Earth's surface. The sensors operate at L and S bands, with multiple polarizations and a constant look angle, scanning across a wide swath. The study included detailed analyses of science requirements, reflector and feedhorn design and performance, microwave emissivity measurements of mesh samples, design and test of lightweight radar electronic~., launch vehicle accommodations, rotational dynamics simulations, and an analysis of attitude control issues associated with the antenna and spacecraft, The goal of the study was to advance the technology readiness of the overall concept to a level appropriate for an Earth science emission.

Njoku, E.↗

UNIFORM INFALL TOWARD THE COMETARY H II REGION IN THE G34.26+0.15 COMPLEX?

Gas accretion is a key process in star formation. However, gas infall detections in high-mass, star-forming regions with high spatial resolution observations are rare. Here, we report the detection of gas infall toward a cometary ultracompact H II region ({sup C)} in the G34.26+0.15 complex. The observations were made with the IRAM 30 m, the James Clerk Maxwell Telescope 15 m telescope, and the Submillimeter Array (SMA). The hot core associated with 'C' has a mass of ∼76 ± 11 M{sub ☉} and a volume density of (1.1 ± 0.2) × 10{sup 8} cm{sup –3}. The HCN (3-2) and HCO{sup +} (1-0) lines observed by single dishes and the CN (2-1) lines observed by the SMA show redshifted absorption features, indicating gas infall. We found a linear relationship between the line width and optical depth of the CN (2-1) lines. Those transitions with larger optical depths and line widths have larger absorption areas. However, the infall velocities measured from different lines seem to be constant, indicating that the gas infall is uniform. We also investigated the evolution of gas infall in high-mass, star-forming regions. A tight relationship was found between the infall velocity and the total dust/gas mass. At stages prior to the hot core phase, the typical infall velocity and mass infall rate are ∼1 km s{sup –1} and ∼10{sup –4} M{sub ☉} yr{sup –1}, respectively. While in more evolved regions, the infall velocity and mass infall rates can reach as high as several km s{sup –1} and ∼10{sup –3}-10{sup –2} M{sub ☉} yr{sup –1}, respectively. Accelerated infall has been detected toward some hypercompact H II and ultracompact H II regions. However, the acceleration phenomenon is not seen in more evolved ultracompact H II regions (e.g., G34.26+0.15)

79 ASTRONOMY AND ASTROPHYSICS↗

Using Molecular Dynamics to quantify the electrical double layer and examine the potential for its direct observation in the in-situ TEM

Understanding the fundamental processes taking place at the electrode-electrolyte interface in batteries will play a key role in the development of next generation energy storage technologies. One of the most fundamental aspects of the electrode-electrolyte interface is the electrical double layer (EDL). Given the recent development of high spatial resolution in-situ electrochemical cells for scanning transmission electron microscopy (STEM), there now exists the possibility that we can directly observe the formation and dynamics of the EDL. In this paper we predict electrolyte structure within the EDL using classical models and atomistic Molecular Dynamics (MD) simulations. The MD simulations show that the classical models fail to accurately reproduce concentration profiles that exist within the electrolyte. It is thus suggested that MD must be used in order to accurately predict STEM images of the electrode-electrolyte interface. Using MD and image simulations together for a high contrast electrolyte (the high atomic number CsCl electrolyte), it is determined that, for a smooth interface, concentration profiles within the EDL should be visible experimentally. When normal experimental parameters such as rough interfaces and low-Z electrolytes (like those used in Li-ion batteries) are considered, observation of the EDL appears to be more difficult.

25 ENERGY STORAGE↗

TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion

Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.

42 ENGINEERING↗

Progress In Developing Laser Based Post Irradiation Examination Infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in a high rad environment. The characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization techniques provide the ability to be remote and robust in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: Laser Shock Laser based ultrasonic C-scan system Gas Assay, Sample, and Recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as LWR fuel, plate fuel, and next generation fuel forms, for PIE in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. The shock wave travels as a compression wave through the material to the free (unconfined) back surface and reflects back through the material under test as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal de-lamination failure. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the laser shock technique. The laser ultrasonic system will be fully capable of performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology in complex components. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element and the analysis of fission gases released from the fuel is important to understanding the performance of reactor fuels and materials. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The main function of the laser in this application is to puncture the fuel element to allow the fission gas to escape and if necessary to weld the spot close. The GASR station will have the inherent capability to perform cutting welding and joining functions within a hot-cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALMA Observations of Vibrationally Excited HC{sub 3}N Lines Toward Orion KL

We present high spatial resolution ALMA observations of vibrational transitions of HC{sub 3}N toward Orion KL in the 214–247 GHz frequency band. 41 transitions of HC{sub 3}N in 7 vibrationally excited states, and 23 transitions of {sup 13}C isotopologues of HC{sub 3}N in 2 vibrational states are detected. The line images show that vibrationally excited HC{sub 3}N lines originate mainly from the hot core of Orion and IRc7. The images of HC{sub 3}N vibrationally excited lines show that the line emission peaks associated with the hot core move from south to northeast as E{sub u} increases. Based on multiple transitions of each vibrationally excited state, we performed local thermodynamic equilibrium calculations in the XCLASS suite toward the hot core and IRc7 positions. Generally, transitions in highly excited states have higher rotational temperatures and lower column densities. The rotational temperatures and column densities of the hot core range from 93 to 321 K, and from 1.0×10{sup 14} to 4.9×10{sup 16} cm{sup −2}, respectively. Lower rotational temperatures ranging from 88 to 186 K and column densities from 1.0×10{sup 14} to 3.2×10{sup 16} cm{sup −2} are obtained toward IRc7. The facts that the hot core emission peaks of vibrationally excited HC{sub 3}N lines move from south to northeast with increasing E{sub u}, and that higher-energy HC{sub 3}N lines have higher rotational temperatures and lower column densities, appear to support that the hot core is externally heated. The emission peaks are moving along the major axis of the SiO outflow, which may indicate that higher-energy HC{sub 3}N transitions are excited by interaction between pre-existing dense medium and shocks generated by SiO outflows.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of the design of the ITER ECE diagnostic

In this study, the baseline design for the ITER electron cyclotron emission (ECE) diagnostic has entered the detailed preliminary design phase. Two plasma views are planned, a radial view and an oblique view that is sensitive to distortions in the electron momentum distribution near the average thermal momentum. Both views provide high spatial resolution electron temperature profiles when the momentum distribution remains Maxwellian. The ECE diagnostic system consists of the front-end optics, including two 1000 K calibration sources, in equatorial port plug EP9, the 70-1000 GHz transmission system from the front-end to the diagnostics hall, and the ECE instrumentation in the diagnostics hall. The baseline ECE instrumentation will include two Michelson interferometers that can simultaneously measure ordinary and extraordinary mode ECE from 70 to 1000 GHz, and two heterodyne radiometer systems, covering 122-230 GHz and 244-355 GHz. Significant design challenges include 1) developing highly-reliable 1000 K calibration sources and the associated shutters/mirrors, 2) providing compliant couplings between the front-end optics and the polarization splitter box that accommodate displacements of the vacuum vessel during plasma operations and bake out, 3) protecting components from damage due to stray ECH radiation and other intense millimeter wave emission and 4) providing the low-loss broadband transmission system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Inference for Earth System Predictability

An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.

54 ENVIRONMENTAL SCIENCES↗

In Situ Inference for Earth System Predictability

Focal Area: Focal Area 3: Insight gleaned from complex simulated data using AI, big data analytics, and other advanced methods, including explainable AI and physics- or knowledge-guided AI. Science Challenge: An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.

54 ENVIRONMENTAL SCIENCES↗

Automating the detection of hydrological barriers and fragmentation in wetlands using deep learning and InSAR

The loss of hydrological connectivity and fragmentation of natural wetlands is a widespread driver of wetland degradation. Understanding where and how natural connectivity is impaired is essential for managing, protecting and remediating these ecosystems. Wetland Interferometric Synthetic Aperture Radar (Wetland InSAR) can provide information on surface flow orientation in wetlands at a high spatial resolution, which can be used for barrier detection. However, the broad application of this approach is constrained by the labour-intensive manual delineation of barriers based on mapped water levels. This study presents the first deep learning-based methodology for the automated detection of hydrological barriers. We trained a deep convolutional network to segment edge features of hydrological barriers in 25 image pairs captured by ALOS PALSAR-1 L-Band InSAR between 2006 and 2011. The training dataset consists of manually labelled and delineated barriers showing abrupt changes in water surface elevation and wrapped interferograms with high coherence. We tested this method across three wetland sites: the Everglades and southern Louisiana wetlands (United States) and the Cienaga de Zapata (Cuba). Across these sites, the convolutional network detected hydrological barriers with up to 84% accuracy. The model performed particularly well for linear hydrological barriers such as roads, dikes, and channels. Notably, some barriers impede flow only seasonally, appearing during low water levels and disappearing when water levels rise. Our automated approach to detecting and assessing wetland hydrologic connectivity can be applied more broadly to support the effective management of fragmented wetland ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-446: Evaluation of the Dosimetric Properties of a Diode Detector to Proton Radiosurgery

Purpose: To test the PTW PR60020 proton dosimetry diode in radiation fields relevant to proton radiosurgery applications and evaluate its suitability as a high resolution, real time dosimetry device. Methods: Data was collected using our standard nominal radiosurgery energies of 126 MeV and 155 MeV through a single stage scattering system, corresponding to a range of 9.7 and 15 cm in water respectively. Various beam modulations were tested as part of this study. Depth dose and beam profile measurements were completed with the PTW PR60020 dosimetry diode with comparative measurements using a PTW Markus ionization chamber and EBT2 Gafchromic film. Monte Carlo simulations were also completed for comparison. Results: The single 1 mm{sup 2} by 20 μm thick sensitive volume allowed for high spatial resolution measurements while maintaining sufficient sensitive volume to ensure that measurements could be completed without excessive beam delivery. Depth dose profiles exhibited negligible LET dependence which typically impacts film and other solid state dosimetry devices, while beam ranges measured with the PTW diode were within 1 mm of ion chamber data. In an edge on arrangement beam profiles were also measured within 0.5 mm full-width at half-maximum at various depths as compared to film and simulation data. Conclusion: The PTW PR60020 proved to be a very useful radiation metrology apparatus for proton radiosurgery applications. Its waterproof and rugged construction allowed for easy deployment in phantoms or water tanks that are commonly used in proton radiosurgery QA. Dosimetrically, the diode exhibited negligible LET dependence as a function of depth, while in edge on arrangement to the incident proton beam it facilitated the measurement of beam profiles with a spatial resolution comparable to both Monte Carlo and film measurements. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Identification and Differentiation of Spectrally Similar Hydrothermal Minerals on Mars

Early telescopic observations corroborated hydration related absorptions on Mars in the infrared. Images from the Viking missions led to speculation of hydrothermal alteration and were followed by two missions which mapped the spatial variability of the ~ 3 μm hydration feature. Since then, the Compact Reconnaissance Imager for Mars (CRISM) has provided high spatial resolution (up to 18m) spectral identification of a suite of hydrothermal and diagenetic minerals which have illuminated a range of formation mechanisms. Presence/absence and spatial segregation or mixing of minerals like prehnite, epidote, chlorite amphiboles, and mixed-layer Fe/Mg smectite-chlorite provide valuable evidence for the geologic setting of deposits on Earth, and these phases are often used as temperature and aqueous chemistry indicators in terrestrial systems. Mapping the distribution of these phases will help to answer whether Mars had widespread conditions favorable for low-grade metamorphism and diagenesis, or only focused hydrothermal systems in areas of high heat flow. Further characterizing the chemistry and structure of these phases will then help to answer how most of the widespread Fe/Mg phyllosilicates formed, further defining early geochemical cycling and climate. A fully automated approach for accurate mapping of important hydrothermal mineral phases on Mars has been a challenge. Due to overlapping features in the M-OH region (~2.2-2.4 μm), the strongest absorption features of chlorite, prehnite, and epidote in the short-wave infrared are difficult to distinguish from one another and from the most commonly occurring hydrated silicates on Mars, Fe/Mg smectites. Weaker absorptions are present in both prehnite and epidote which help to distinguish them from chlorite and smectites, but their relative strength in the presence of noise and spatial mixing is often too low to confidently identify them without the noise suppression and feature enhancement methods described here. The spectral signatures of mixed-layer Fe/Mg smectite-chlorite and partially chloritized Fe/Mg smectites have not yet been adequately assessed. Here we evaluate the effectiveness of two empirical and statistical methods for identifying and differentiating these phases using CRISM data.

Rasmussen, B. P.↗

Direct electron beam patterning of electro-optically active PEDOT:PSS

The optical and electronic tunability of the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has enabled emerging applications as diverse as bioelectronics, flexible electronics, and micro- and nano-photonics. High-resolution spatial patterning of PEDOT:PSS opens up opportunities for novel active devices in a range of fields. However, typical lithographic processes require tedious indirect patterning and dry etch processes, while solution-processing methods such as ink-jet printing have limited spatial resolution. Here, we report a method for direct write nano-patterning of commercially available PEDOT:PSS through electron-beam induced solubility modulation. The written structures are water stable and maintain the conductivity as well as electrochemical and optical properties of PEDOT:PSS, highlighting the broad utility of our method. We demonstrate the potential of our strategy by preparing prototypical nano-wire structures with feature sizes down to 250 nm, an order of magnitude finer than previously reported direct write methods, opening the possibility of writing chip-scale microelectronic and optical devices. We finally use the high-resolution writing capabilities to fabricate electrically-switchable optical diffraction gratings. We show active switching in this archetypal system with >95 % contrast at CMOS-compatible voltages of +2 V and -3 V, offering a route towards highly-miniaturized dynamic optoelectronic devices.

42 ENGINEERING↗

Constraining the Sulfur Dioxide Degassing Flux from Turrialba Volcano, Costa Rica Using Unmanned Aerial System Measurements

Observed sulfur dioxide (SO2)mixing ratios onboard unmanned aerial systems (UAS) duringMarch 11-13, 2013 are used to constrain the three-day averaged SO2 degassing flux fromTurrialba volcanowithin a Bayesian inverse modeling framework. A mesoscale model coupled with Lagrangian stochastic particle backward trajectories is used to quantify the source-receptor relationships at very high spatial resolutions (i.e., b1 km). The model shows better performance in reproducing the near-surface meteorological properties and observed SO2 variations when using a first-order closure non-local planetary boundary layer (PBL) scheme. The optimized SO2 degassing fluxes vary from 0.59 +/- 0.37 to 0.83 +/- 0.33 kt d−1 depending on the PBL scheme used. These fluxes are in good agreement with ground-based gas flux measurements, and correspond to corrective scale factors of 8-12 to the posteruptive SO2 degassing rate in the AeroCom emission inventory. The maximum a posteriori solution for the SO2 flux is highly sensitive to the specification of prior and observational errors, and relatively insensitive to the SO2 loss term and temporal averaging of observations. Our results indicate relatively low degassing activity but sustained sulfur emissions from Turrialba volcano to the troposphere during March 2013. This study demonstrates the utility of low-cost small UAS platforms for volcanic gas composition and flux analysis.

Xi, Xin↗

Progress in developing laser based post irradiation examination infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in high rad environments. This characterization work is performed remotely and in environments generally hostile to instrumentation. Laser based characterization techniques provide the ability to operate remotely and robustly in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility (HFEF) at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: -) laser shock, -) laser based ultrasonic C-scan system and -) gas assay, sample and recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as Light Water Reactor (LWR) fuel, plate fuel, and next generation fuel forms in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize de bonding caused by the application of the laser shock as well as performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology. A spectroscopy capability can be added later as the salient components to perform Light Induced Breakdown Spectroscopy will be in place. Additional fiber ports in the feed-through will also enable future spectroscopic techniques to be efficiently installed and operated. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element/capsule and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element/capsule and the analysis of fission gases released is important to understanding the performance of reactor fuels and materials. The main function of the laser in this application is to puncture the fuel rod or plate to allow the fission gas to escape and if necessary to weld the hole close. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The GASR upgrade will match the functionality of the current system and provide these important functions on fuels made from current and future engineered materials. The GASR station will also have the inherent capability to perform cutting welding and joining functions within a hot-cell. The extra fiber ports built into the hot cell feed-through will also enable the efficient installation of future laser processing work benches. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗