Search NASA⌕ Search

SEARCH · Search NASA

Results for “Initialization method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Design and Implementation of Scientific Software Components to Enable Multiscale Modeling: The Effective Fragment Potential (QM/EFP) Method

The design and development of scientific software components to provide an interface to the effective fragment potential (EFP) methods are reported. Multiscale modeling of physical and chemical phenomena demands the merging of software packages developed by research groups in significantly different fields. Componentization offers an efficient way to realize new high performance scientific methods by combining the best models available in different software packages without a need for package readaptation after the initial componentization is complete. The EFP method is an efficient electronic structure theory based model potential that is suitable for predictive modeling of intermolecular interactions in large molecular systems, such as liquids, proteins, atmospheric aerosols, and nanoparticles, with an accuracy that is comparable to that of correlated ab initio methods. The developed components make the EFP functionality accessible for any scientific component-aware software package. The performance of the component is demonstrated on a protein interaction model, and its accuracy is compared with results obtained with coupled cluster methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-efficiency, high-fidelity charge initialization of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (N-𝑉) centers in diamond exhibit long spin-coherence times, optical initialization, and optical-spin readout under ambient conditions, making them excellent quantum sensors. However, the conventional scheme for charge-state initialization based on off-resonant green excitation results in significant state-preparation errors, typically around 30%. One method for improving charge-state initialization fidelity is to use multicolor excitation, which has been demonstrated to achieve a near-unity preparation fidelity for bulk N-𝑉 centers by using a few milliseconds of near-infrared (NIR) (5-mW) and green (10-μ⁢W) excitation. The translation of such schemes to N-𝑉 centers near the diamond surface with higher-efficiency optical pumping would enable new applications in nanoscale sensing. Here, we demonstrate a protocol for efficient charge initialization of shallow N-𝑉 centers between 5 nm and 15 nm from the diamond surface. By carefully studying the charge dynamics of shallow N-𝑉 centers, we identify a region of parameter space that allows for near-unity (95%) charge initialization within 300 μ⁢s of NIR (905-nm, 1-mW) and green (520-nm, 10-μ⁢W) excitation. The time to 90% charge initialization can be as fast as 10 μ⁢s for 4 mW of NIR and 39 μ⁢W of green illumination. This fast, efficient charge initialization protocol will especially benefit nanoscale sensing applications in which state-preparation errors currently prohibit scaling, such as measuring higher-order multipoint correlators.

infrared techniques↗

Outcome of Primary Desmoid Tumors at All Anatomic Locations Initially Managed with Active Surveillance

Background: The behavior of desmoid tumors is unpredictable and varies from spontaneous remission to symptomatic and radiologic progression. This study aimed to evaluate the radiologic and symptomatic course of the disease in patients initially managed with active surveillance. Methods: Patients with a primary desmoid tumor at any anatomic location diagnosed between 1998 and 2016 were identified in a prospectively maintained database from a single sarcoma reference center in the United Kingdom. Inverse univariate Cox proportional hazard regression analyses were conducted to evaluate the course of the disease and indications for initiating treatment. Results: The study identified 168 patients with a primary desmoid tumor initially managed with active surveillance. The tumors were located in the abdominal wall (n = 61, 36%), an extremity (n = 51, 30%), chest wall (n = 30, 18%), intra-abdominal site (n = 15, 9%), or elsewhere (n = 11, 6%). Of all the patients, 36% experienced radiologic progressive disease, 36% had stable disease, and 27% regressed. The patients younger than 50 years were more likely to progress (p = 0.046), whereas the patients with chest wall or upper-extremity tumors reported significantly more pain (p = 0.01). Eventually, 46% of the patients proceeded to treatment. The median time to start of treatment after initial surveillance was 31 months, whereas the median follow-up time for the patients not receiving any treatment was 40.5 months. The indications for initiation of treatment were pain (32%), progression (31%), or both (13%). Conclusions: Patients with desmoid tumors can be managed with initial active surveillance, although almost half of patients may eventually need treatment. Pain, tumor progression, or both are the most common indications for the initiation of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the stability of numerical integration routines.

Numerical integration methods for the solution of initial value problems for ordinary vector differential equations may be modelled as discrete time feedback systems. The stability criteria discovered in modern control theory are applied to these systems and criteria involving the routine, the step size and the differential equation are derived. Linear multistep, Runge-Kutta, and predictor-corrector methods are all investigated.

Glover, K.↗

On the stability of numerical integration routines for ordinary differential equations.

Numerical integration methods for the solution of initial value problems for ordinary vector differential equations may be modelled as discrete time feedback systems. The stability criteria discovered in modern control theory are applied to these systems and criteria involving the routine, the step size and the differential equation are derived. Linear multistep, Runge-Kutta, and predictor-corrector methods are all investigated.

Glover, K.↗

A Government/Industry Summary of the Design Analysis Methods for Vibrations (DAMVIBS) Program

The NASA Langley Research Center in 1984 initiated a rotorcraft structural dynamics program, designated DAMVIBS (Design Analysis Methods for VIBrationS), with the objective of establishing the technology base needed by the rotorcraft industry for developing an advanced finite-element-based dynamics design analysis capability for vibrations. An assessment of the program showed that the DAMVIBS Program has resulted in notable technical achievements and major changes in industrial design practice, all of which have significantly advanced the industry's capability to use and rely on finite-element-based dynamics analyses during the design process.

Kvaternik, Raymond G.↗

Dose prescription complexity versus tumor control probability in biologically conformal radiotherapy

The technical feasibility and potential benefits of voxel-based nonuniform dose prescriptions for biologically heterogeneous tumors have been widely demonstrated. In some cases, an ''ideal'' dose prescription has been generated by individualizing the dose to every voxel within the target, but often this voxel-based prescription has been discretized into a small number of compartments. The number of dose levels utilized and the methods used for prescribing doses and assigning tumor voxels to different dose compartments have varied significantly. The authors present an investigation into the relationship between the complexity of the dose prescription and the tumor control probability (TCP) for a number of these methods. The linear quadratic model of cell killing was used in conjunction with a number of modeled tumors heterogeneous in clonogen density, oxygenation, or proliferation. Models based on simple mathematical functions, published biological data, and biological image data were investigated. Target voxels were assigned to dose compartments using (i) simple rules based on the initial biological distribution, (ii) iterative methods designed to maximize the achievable TCP, or (iii) methods based on an ideal dose prescription. The relative performance of the simple rules was found to depend on the form of heterogeneity of the tumor, while the iterative and ideal dose methods performed comparably for all models investigated. In all cases the maximum achievable TCP was approached within the first few (typically two to five) compartments. Results suggest that irrespective of the pattern of heterogeneity, the optimal dose prescription can be well approximated using only a few dose levels but only if both the compartment boundaries and prescribed dose levels are well chosen.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing fast and automatic segmentation of the prostate. Funding Support, Disclosures, and Conflict of Interest: AS Nelson is a partial owner of MIM Software, Inc. AS Nelson, and A Swallen are current employees at MIM Software, Inc.

60 APPLIED LIFE SCIENCES↗

Application of the metabolic modeling pipeline in KBase to categorize reactions, predict essential genes, and predict pathways in an isolate genome

The DOE Systems Biology Knowledgebase (KBase) platform offers a range of powerful tools for the reconstruction, refinement, and analysis of genome-scale metabolic models built from microbial isolate genomes. In this chapter, we describe and demonstrate these tools in action with an analysis of isoprene production in the Bacillus subtilis DSM genome. Two different methods are applied to build initial metabolic models for the DSM genome, then the models are gapfilled in three different growth conditions. Next, flux balance analysis (FBA) and flux variability analysis (FVA) techniques are applied to both study the growth of these models in minimal media and classify reactions within each model based on essentiality and functionality. The models are applied with the FBA method to predict essential genes, which are then compared to an updated list of essential genes obtained for B. subtilis 168, a very similar strain to the DSM isolate. The models are also applied to simulate Biolog growth conditions, and these results are compared with Biolog data collected for B. subtilis 168. Finally, the DSM metabolic models are applied to explore the pathways and genes responsible for producing isoprene in this strain. These studies demonstrate the accuracy and utility of models generated from the KBase pipelines, as well as exploring the tools available for analyzing these models.

DOE knowledgebase↗

Application of the Metabolic Modeling Pipeline in KBase to Categorize Reactions, Predict Essential Genes, and Predict Pathways in an Isolate Genome

The DOE Systems Biology Knowledgebase (KBase) platform offers a range of powerful tools for the reconstruction, refinement, and analysis of genome-scale metabolic models built from microbial isolate genomes. In this chapter, we describe and demonstrate these tools in action with an analysis of isoprene production in the Bacillus subtilis DSM genome. Two different methods are applied to build initial metabolic models for the DSM genome, then the models are gapfilled in three different growth conditions. Next, flux balance analysis (FBA) and flux variability analysis (FVA) techniques are applied to both study the growth of these models in minimal media and classify reactions within each model based on essentiality and functionality. The models are applied with the FBA method to predict essential genes, which are then compared to an updated list of essential genes obtained for B. subtilis 168, a very similar strain to the DSM isolate. The models are also applied to simulate Biolog growth conditions, and these results are compared with Biolog data collected for B. subtilis 168. Finally, the DSM metabolic models are applied to explore the pathways and genes responsible for producing isoprene in this strain. These studies demonstrate the accuracy and utility of models generated from the KBase pipelines, as well as exploring the tools available for analyzing these models.

Allen, Benjamin↗

Interlaboratory Reproducibility of Contour Method Data Analysis and Residual Stress Calculation

While the contour method for residual stress assessment has developed rapidly, no published study documents its interlaboratory reproducibility. Objective: Here we report an initial reproducibility experiment focused on contour method data analysis and residual stress calculation. The experiment uses surface topography data from a physical process simulation of elastic-plastic beam bending. The simulation provides surface topography, for input to the contour method data analysis, as well as a known residual stress field with 130 MPa peak magnitude. Additionally, to increase realism, noise and specific artifacts are added to the topography data. A group of participants received the topography data (without the known residual stress), independently analyzed the data, and submitted results as a two-dimensional residual stress field. Analysis of submissions provides a group average residual stress field and the spatial distribution of reproducibility standard deviation. The group average residual stress agrees with the known stress in magnitude and spatial trend. The reproducibility standard deviation ranges from 2 to 54 MPa over the measurement plane, with an average of 5.4 MPa. Reproducibility standard deviation is smaller in the cross-section interior (≤ 5 MPa), modest near local extrema in the stress field (5 to 10 MPa), and larger near the cross-section boundaries (10 to 30 MPa). Overall, the largest values of reproducibility standard deviation (up to 54 MPa) occur in limited areas where artifacts had been added to the topography data; while some participants identified and removed these artifacts, some did not, leading to systematic differences that elevated the standard deviation.

42 ENGINEERING↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The motion of throw away detectors relative to the space shuttle

The motions of throw away detectors (TAD's) are analyzed using the linearized relative motion equations. The TAD's are to be used in the amps program as diagnostic instruments for making various measurements near the shuttle. The TAD's are ejected from the shuttle in arbitrary directions with small relative velocities (0.1 to 1.0 m/s) their subsequent trajectories relative to the shuttle are analyzed. Initial conditions that are likely to result in recontact between the TAD and the shuttle are identified. The sensitivity of the motion to variations in the initial conditions, possibly resulting from inaccuracy in the ejection mechanism, are analyzed as are effects of atmospheric drag. A targeting method, a method of giving the TAD correct initial conditions such that it will pass through a given point relative to the shuttle at a given time, is developed. The results of many specific cases are presented in graphical form.

Mullins, L. D.↗

Subsonic panel method for designing wing surfaces from pressure distribution

An iterative method has been developed for designing wing section contours corresponding to a prescribed subcritical distribution of pressure. The calculations are initialized by using a surface panel method to analyze a baseline wing or wing-fuselage configuration. A first-order expansion to the baseline panel method equations is then used to calculate a matrix containing the partial derivative of potential at each control point with respect to each unknown geometry parameter. In every iteration cycle, the matrix is used both to calculate the geometry perturbation and to analyze the perturbed geometry. The distribution of potential on the perturbed geometry is established by simple linear extrapolation from the baseline solution. The extrapolated potential is converted to pressure by Bernoulli's equation. Not only is the accuracy of the approach good for very large perturbations, but the computing cost of each complete iteration cycle is substantially less than one analysis solution by a conventional panel method.

Bristow, D. R.↗

Use of MODIS Land and Sea Surface Temperatures to Initialize Mesoscale Models

As computer power continues to increase, mesoscale models are initialized at all hours of the day and continue to be run at higher and higher spatial resolutions. As a result, initializing land surface temperature can be problematic. The majority of research-based models are initialized at 00 and 12 UTC when upper air observations and reanalysis fields are available. The landsea surface temperatures are then set equal to the two-meter air temperature produced by the preprocessor analysis system. This particular procedure might be valid in the early morning hours just prior to sunrise, but it becomes less valid during the remainder of the diurnal cycle. Operational models, such as the Rapid Update Cycle run at the National Centers for Environmental Prediction (NCEP), are initialized every hour on a daily basis. This presents a unique challenge to the initial specification of the land temperature, especially during the first several hours of the solar heating cycle when land and overlying air temperatures are far from being the same. Another issue that needs to be addressed is the spatial variability of land surface temperature. By early next year, the NCEP operational Eta model will be employed at 8 km resolution. Methods to accurately specify the initial land surface temperature at such high resolution need to be explored. This paper presents the results of using data from the NASA Moderate Imaging Sensor aboard the TERRA Satellite to initialize land and sea surface temperatures within the Pennsylvania State University/National Center for Atmospheric Research (PSU/NCAR) 5'th generation Mesoscale Model (MM5). We have simulated a northern Gulf Coast sea breeze case to demonstrate the utility of using the MODIS data to initialize both the land and sea surface temperature fields. Model grid configurations of 12-, 4-, and l-km are employed.

Arnold, James E.↗

Automatic Determination of the Conic Coronal Mass Ejection Model Parameters

Characterization of the three-dimensional structure of solar transients using incomplete plane of sky data is a difficult problem whose solutions have potential for societal benefit in terms of space weather applications. In this paper transients are characterized in three dimensions by means of conic coronal mass ejection (CME) approximation. A novel method for the automatic determination of cone model parameters from observed halo CMEs is introduced. The method uses both standard image processing techniques to extract the CME mass from white-light coronagraph images and a novel inversion routine providing the final cone parameters. A bootstrap technique is used to provide model parameter distributions. When combined with heliospheric modeling, the cone model parameter distributions will provide direct means for ensemble predictions of transient propagation in the heliosphere. An initial validation of the automatic method is carried by comparison to manually determined cone model parameters. It is shown using 14 halo CME events that there is reasonable agreement, especially between the heliocentric locations of the cones derived with the two methods. It is argued that both the heliocentric locations and the opening half-angles of the automatically determined cones may be more realistic than those obtained from the manual analysis

Pulkkinen, A.↗

Global convergence of inexact Newton methods for transonic flow

In computational fluid dynamics, nonlinear differential equations are essential to represent important effects such as shock waves in transonic flow. Discretized versions of these nonlinear equations are solved using iterative methods. In this paper an inexact Newton method using the GMRES algorithm of Saad and Schultz is examined in the context of the full potential equation of aerodynamics. In this setting, reliable and efficient convergence of Newton methods is difficult to achieve. A poor initial solution guess often leads to divergence or very slow convergence. This paper examines several possible solutions to these problems, including a standard local damping strategy for Newton's method and two continuation methods, one of which utilizes interpolation from a coarse grid solution to obtain the initial guess on a finer grid. It is shown that the continuation methods can be used to augment the local damping strategy to achieve convergence for difficult transonic flow problems. These include simple wings with shock waves as well as problems involving engine power effects. These latter cases are modeled using the assumption that each exhaust plume is isentropic but has a different total pressure and/or temperature than the freestream.

Young, David P.↗

A reverse Monte Carlo method for deriving optical constants of solids from reflection electron energy-loss spectroscopy spectra

A reverse Monte Carlo (RMC) method is developed to obtain the energy loss function (ELF) and optical constants from a measured reflection electron energy-loss spectroscopy (REELS) spectrum by an iterative Monte Carlo (MC) simulation procedure. The method combines the simulated annealing method, i.e., a Markov chain Monte Carlo (MCMC) sampling of oscillator parameters, surface and bulk excitation weighting factors, and band gap energy, with a conventional MC simulation of electron interaction with solids, which acts as a single step of MCMC sampling in this RMC method. To examine the reliability of this method, we have verified that the output data of the dielectric function are essentially independent of the initial values of the trial parameters, which is a basic property of a MCMC method. The optical constants derived for SiO{sub 2} in the energy loss range of 8-90 eV are in good agreement with other available data, and relevant bulk ELFs are checked by oscillator strength-sum and perfect-screening-sum rules. Our results show that the dielectric function can be obtained by the RMC method even with a wide range of initial trial parameters. The RMC method is thus a general and effective method for determining the optical properties of solids from REELS measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗