Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Assessment of Long-term Trends in the Collection 4 Total Ozone Record from the Ozone Monitoring Instrument

Long-term changes in total ozone affect the amount of harmful UV radiation reaching Earth’s surface and reflect progress made towards recovery of stratospheric ozone. Satellite total ozone data are also used to estimate long-term trends in tropospheric ozone, a reactive and potent greenhouse gas, by subtracting the stratospheric column timeseries from that of total ozone. For these scientific applications, the long-term stability should be better than 1%. Left unchecked, instrument calibration drift can produce a trend of this magnitude or greater. NASA has produced nearly twenty years of total ozone data from the Ozone Monitoring Instrument (OMI) using the Total Ozone Mapping Spectrometer (TOMS) algorithm. The drift in the OMI instrument as monitored by ice radiance calibration has been relatively slow, but it has reached a level of ~3% over the mission lifetime. This drift was corrected in the recently released Collection 4 OMI calibrated radiances, updating the Collection 3 calibration released in 2006. We have reprocessed the OMI total ozone record using the Collection 4 calibration and updates to the TOMS algorithm. We summarize these changes and evaluate their impact by comparing to the previous Collection 3 OMI dataset, the Suomi NPP Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) and Solar Backscatter UV (SBUV) Merged Ozone Dataset (MOD) total ozone records and other independent satellite total ozone datasets. Climatological radiance residuals from OMI and OMPS-NM are calculated and compared to investigate differences in spectral calibration that can cause drifts in long-term total ozone trends. We also analyze the tropospheric ozone record produced using the Collection 4 OMI total ozone and stratospheric column ozone from MLS. Collection 3 OMI data processed with the TOMS algorithm show a positive drift relative to other satellite and ground-based data of 1-2 DU per decade. Initial results show that this drift is reduced in Collection 4 OMI, due to the updated OMI calibration. In this work we will quantify the improvements in Collection 4 OMI relative to independent data sources at both the ozone and radiance level

Collection 4 OMI Total Ozone↗

Use of TEMPO as a Proxy for Hyperspectral Geostationary Ocean Color Measurements from the GeoXO OCX Instrument: Harnessing Machine Learning and Principal Component Techniques for Atmospheric and Glint Correction

Retrievals of ocean color from space are important for better understanding the ocean ecosystem. The launch of atmospheric geostationary hyperspectral sensors such as TEMPO, provides a unique opportunity to examine the diurnal variability in ocean ecology. While TEMPO does not have as high spatial resolution or full spectral coverage as planned coastal ocean sensors such as the Geosynchronous Littoral Imaging and Monitoring Radiometer (GLIMR) or GeoXO Ocean Color instrument (OCX), its hourly measurements provide coverage of regions such as Lake Erie and the Gulf of Mexico at spatial scales of approximately 5 km. These data can be useful for testing new algorithms. We will apply our newly developed machine learning based atmospheric correction approach for ocean color retrievals to TEMPO data. Our approach begins by decomposing measured radiances from hyperspectral sensors into spectral features that describe the scattering and absorption of the atmosphere as well as the underlying surface reflectance. The coefficients of the principal components are then used to train a neural network to predict ocean color properties derived from collocated MODIS/VIIRS physically-based retrievals. This machine learning approach does not rely on radiative transfer modeling, and the use of MODIS/VIIRS data for training accounts for possible calibration b in hyperspectral data. Previously, we applied our approach using blue and UV wavelengths with the Ozone Monitoring Instrument (OMI) and TROPOspheric Monitoring Instrument (TROPOMI) to show that it can estimate ocean color properties in less-than-ideal conditions such as lightly to moderately clouded conditions as well as sun glint and thus improve the spatial coverage of ocean color measurements. TEMPO provides an opportunity to improve on this approach since it will provide collocated measurements at green and red wavelengths that were not available from OMI and TROPOMI and are important particularly for coastal waters. Additionally, our technique can be applied early in the mission and has potential to demonstrate the value of near real time ocean color products that are important for monitoring of harmful algae blooms and other oceanic phenomena.

Zachary Fasnacht↗

Performance Evaluation of Clouds and the Earth’s Radiant Energy System (CERES) Instruments in Generating A Stable Earth Radiation Budget Multi-Decadal Data Record

Clouds and the Earth’s Radiant Energy System (CERES) instrument is designed to measure the earth-reflected solar and earth-emitted longwave radiances, two components of the Earth Radiation Budget. CERES instrument measure radiances in 0.3 to 5.0 micron region with Shortwave (SW) sensor, 0.3 to >100 microns with Total (TOT) sensor, and either 8 - 12 micron with Window (WN) sensor or 5 – 35 micron with longwave (LW) sensor. The on-board internal calibration module (ICM) is used to monitor the stability of the sensors and to correct the pre-launch determined sensor gains for radiance calculations. Corrections for spectral changes occurring in different wavelength regions observed through vicarious studies were applied to sensor response function used in radiance determination. The resulting global flux long term trends from each instrument have shown consistent behavior and provided a stable global record of Top of the Atmosphere (TOA) shortwave and longwave fluxes for the Earth radiation budget climate data record.

Clouds and Earth Radiation Energy System (CERES)↗

A Portable Nitrogen Dioxide Instrument Using Cavity-Enhanced Absorption Spectroscopy

The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent, broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ~520 m. Our precision was measured as 94 pptv (1 s). To date, we have flown this instrument on 3 balloon and 1 UAV test flights. This instrument records data to an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.

TROPOMI↗

Performance Evaluation of Clouds and the Earth’s Radiant Energy System (CERES) Instruments in Generating A Stable Earth Radiation Budget Multi-Decadal Data Record

Clouds and the Earth’s Radiant Energy System (CERES) instrument is designed to measure the earth-reflected solar and earth-emitted longwave radiances, two components of the Earth Radiation Budget. CERES instrument measure radiances in 0.3 to 5.0 micron region with Shortwave (SW) sensor, 0.3 to >100 microns with Total (TOT) sensor, and either 8 - 12 micron with Window (WN) sensor or 5 – 35 micron with longwave (LW) sensor. The on-board internal calibration module (ICM) is used to monitor the stability of the sensors and to correct the pre-launch determined sensor gains for radiance calculations. Corrections for spectral changes occurring in different wavelength regions observed through vicarious studies were applied to sensor response function used in radiance determination. The resulting global flux long term trends from each instrument have shown consistent behavior and provided a stable global record of Top of the Atmosphere (TOA) shortwave and longwave fluxes for the Earth radiation budget climate data record.

Earth Radiation Budget↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral instruments produce high-resolution and information-dense radiance spectra, thus offering the opportunity to reduce uncertainties in retrieval products. An optimal estimation-based cirrus cloud optical and microphysical product retrieval is under development for the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and the Earth Surface Mineral Dust Source Investigation (EMIT) instruments, and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder). The spectral coverage of all three instruments includes the ultraviolet, visible, and near-infrared. In this study a very fast radiative transfer model, the Principal Component-based Radiative Transfer Model in the solar spectral region (PCRTM-Solar), is used for forward modeling computations. This will reduce the computational burden in the forward radiance and Jacobian calculations as the cost function is minimized, enabling the entire AVIRIS, EMIT, and CLARREO-Pathfinder spectral range to be used in the optimal estimation framework. Using the entire spectrum will maximize the information content, resulting in a more robust and more accurate retrieval. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water. Preliminary results will be shown.

Jeffrey Mast↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral shortwave instruments produce high-resolution and information-dense spectra, thus offering the opportunity to reduce uncertainties in retrieval products. We are in the process of developing a retrieval that uses the very fast Principal Component Radiative Transfer Model in the solar spectral region (PCRTM-Solar) in the forward model calculations. This retrieval will use measured reflectances from the NASA Earth Surface Mineral Dust Source Investigation (EMIT) and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder) instruments. In this manuscript we present progress towards a reference retrieval employing a widely used, verified, accurate, yet computationally slower radiative transfer modeling technique. The reference retrieval, while too slow for using the complete hyperspectral measurement, will allow us to study the behavior of retrieval products and help us verify results from our in-development fast retrieval. Both retrievals will use the optimal estimation retrieval framework. In this manuscript we present results from an uncertainty analysis considering three uncertainty sources for a cirrus cloud retrieval in the form of error covariance matrices: reflectance uncertainty due to water vapor, the reflectance uncertainty due to ice crystal scattering assumptions, and the instrument measurement uncertainty. Results show that the uncertainty due to habit selection is the largest, while that due to water vapor is at most 0.6% relative to channel reflectance. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water.

Cirrus cloud↗

Geodetic Reference Instrument Transponder for Small Satellites

The local ties between Satellite Laser Ranging stations and other collocated geodetic stations are an important component of the realization of the International Terrestrial Reference Frame but the survey accuracies are limited due to the inaccessibility of the instrument reference points. The NASA Geodetic Reference Instrument Transponder for Small Satellites (GRITSS) technology demonstration mission is designed to overcome this limitation by using a small satellite as a space-based reference point for tying together the measurement points of collocated geodetic stations. The GRITSS instrument upconverts the Global Positioning System (GPS) signals received at the satellite in real-time to S and X band and transmits them to a VLBI Global Observing System (VGOS) antenna ground station. The measurement observables do not require the satellite to be in view of more than one VLBI station at a time. The GRITSS demonstration mission utilizes a 12-UL CubeSat in a Low Earth, Sun Synchronous orbit. Tracking by the global ILRS network throughout the life of the mission is critical to establishing the space-based reference along with the precision orbit determination required by the measurement concept. Due to limitations in spacecraft power and other constraints, the initial phase of the mission will only broadcast the GRITSS VLBI signals twice a day to each of the NASA VGOS stations in Maryland, Hawaii, and Texas, but other international VGOS stations may be added during the second half of the mission. An overview of the GRITSS mission and measurement concept will be presented.

Stephen M Merkowitz↗

Observed Correlation Between Local Topography and Passive Neutron Measurements from the Dynamic Albedo of Neutrons (DAN) Instrument on the Mars Science Laboratory (MSL) Rover

The Dynamic Albedo of Neutrons (DAN) instrument on the Mars Science Laboratory Curiosity rover primarily measures neutrons that have undergone interactions with rocks and materials in the rover's local environment. As the rover ascends Aeolis Mons, it may encounter more extreme local topography (e.g., cliffs, gullies, canyons). We present three parts of the rover's traverse in which local topography, expressed as the average local relief relative to the rover, is moderately to strongly correlated with an increase in passive thermal neutron count rates. These increases in count rates are consistent with results from radiation transport models of the instrument's performance near simulated topographic features. Additional DAN measurements in areas of high average local relief (>0.25 m) within 5 m of the instrument could bolster this correlation. DAN's sensitivity to topography in its passive mode could be utilized as a new measurement capability and has implications for the operation of future landed missions carrying neutron spectrometers (e.g., VIPER, MoonRanger, Lunar-VISE).

Steven D Dibb↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BeyondPlanck project in terms of motivation, methodology and main products, and provide a guide to a set of companion papers that describe each result in fuller detail. Building directly on experience from ESA's Planck mission, we implement a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a joint posterior distribution P(omega|d), where omega represents the set of all free instrumental (gain, correlated noise, bandpass etc.), astrophysical (synchrotron, free-free, thermal dust emission etc.), and cosmological (CMB map, power spectrum etc.) parameters. Some notable advantages of this approach are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-l CMB polarization reconstruction, paying special attention to the LFI 44 GHz channel. We find evidence of significant residual systematic effects that are still not accounted for in the current processing, but must be addressed in future work. These include a break-down of the 1/f correlated noise model at 30 and 44 GHz, and scan-aligned stripes in the Southern Galactic hemisphere at 44 GHz. On the Northern hemisphere, however, we find that all results are consistent with the LCDM model, and we constrain the reionization optical depth to tau = 0.067 +/- 0.016, with a low-resolution chi-squared probability-to-exceed of 16%. The marginal CMB dipole amplitude is 3359.5 +/- 1.9 uK. (Abridged.)

Andersen, KJ↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

MethodOpt: a Shiny-based graphical user interface for multivariate optimization of sampling and analytical instrumentation

Method optimization is an important step in producing useful data in various experimental settings involving the use of sampling and analytical instrumentation, such as gas-chromatography mass-spectrometry or other analytical techniques. However, traditional optimization techniques often lack the sophistication of more modern optimization techniques developed in areas of applied mathematics. A graphical user interface has been developed that implements a multivariate, multi-objective optimization technique for spectra-generating sampling and analytical instrumentation, which saves substantial time and resources compared to the more traditional approaches to method development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simplified Instrument for Recording and Indicating Frequency and Intensity of Icing Conditions Encountered in Flight

An instrument for recording and indicating the frequency and intensity of aircraft icing conditions encountered in flight has been developed by the NACA Lewis Laboratory to obtain statistical icing data over world-wide air routes during routine airline operations. The operation of the instrument is based on the creation of a differential pressure between an ice-free total-pressure system and a total-pressure system in which small total-pressure holes vented to static pressure are allowed to plug with ice accretion. The simplicity of this operating principle permits automatic operation, and provides relative freedom from maintenance and operating problems. The complete unit weighing only 18 pounds records icing rate, airspeed, and altitude on photographic film and provides visual indications of icing intensity to the pilot.

ICE FORMATION↗

Gap Assessment on Sensors and Instrumentation for Advanced Reactors

The Sensor Technologies for Advanced Reactors Virtual Workshop—sponsored by the Gateway for Accelerated Innovation in Nuclear (GAIN), the Electric Power Research Institute, and the Nuclear Energy Institute—was held to exchange information on sensors and sensor technologies of interest to advanced nuclear technology developers, commercial instrument suppliers, and sensor researchers from Department of Energy (DOE) national laboratories, universities, and industry. The workshop objectives were to discuss measurement requirements and sensor needs for advanced reactor concepts, understand current national laboratory capabilities and accelerated development approaches for sensors and instrumentation, and identify gaps so as to inform applicable DOE Office of Nuclear Energy (DOE-NE) research programs. Due to the complexity of holding group discussions on individual gaps, a survey was sent to workshop participants, and personalized one-on-one feedback sessions were held to elicit additional information. Summaries of these sessions are provided in this gap assessment report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensors and Instrumentation 2022 Summary of Accomplishments

The Advanced Sensors and Instrumentation (ASI) program is the element of the Nuclear Energy Enabling Technologies (NEET) initiative dedicated to Instrumentation and Control (I&C) technology. This document collects in the form of summaries the research accomplishments presented at the program 2022 Annual Review meeting, which was held virtually between October 24 and October 27, 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensors & Instrumentation FY24 Summary of Accomplishments

The Advanced Sensors and Instrumentation (ASI) program is the element of the Nuclear Energy Enabling Technologies (NEET) initiative dedicated to Instrumentation and Control (I&C) technology. This document collects in the form of summaries the research accomplishments presented at the program 2024 Annual Review meeting, which was held virtually between November 4 & 6-7, 2024.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗