Search NASA⌕ Search

SEARCH · Search NASA

Results for “Kernel methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Formation energy puzzle in intermetallic alloys: Random phase approximation fails to predict accurate formation energies

We performed density functional calculations to estimate the formation energies of intermetallic alloys. We used two semilocal approximations, the generalized gradient approximation (GGA) by Perdew-Burke- Ernzerhof (PBE) and the strongly constrained and appropriately normed (SCAN) meta-GGA. In addition, we utilized two nonlocal DFT functionals, the hybrid HSE06, and the state-of-the-art random phase approximation (RPA). The nonlocal functionals such as HSE06 and RPA yield accurate formation energies of binary alloys with completely-filled d-band metals, where semilocal functionals underperform. The accuracy at the nonlocal functionals is greatly reduced when a partially-filled d-band metal is present in an alloy, while PBE-GGA outperforms in these cases. We show that the accurate prediction of formation energies by any DFT method depends on its ability to predict the accurate electronic properties, e.g., valence d-band contribution to the density of states (DOS). The SCAN meta-GGA often corrects the PBE-DOS, however, it does not provide accurate formation energies compared to PBE. This is assumed to be due to the lack of proper error cancellation that should be expected due to the similar bulk nature of both alloys and their constituents, which may improve with the modification of meta-GGA ingredients. RPA yields too negative formation energies of alloys with partially-filled d-band metals. RPA results can be corrected by restoring the exchange-correlation kernel, thereby improving the short-range electron-electron correlation in metallic densities.

36 MATERIALS SCIENCE↗

SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images

Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from the CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.

60 APPLIED LIFE SCIENCES↗

Fuel Specification for Uranium Monocarbide FAST Fuel Specimens

This specification outlines the fabrication requirements for kernel compact uranium monocarbide (UC) fuel to be fabricated at General Atomics (GA) and is already issued in EDMS and is going thru LRS so that it can be shared with the Vendor. The UC fuel will be irradiated in the Advanced Test Reactor (ATR) using the Irradiation System for High-Throughput Acquisition (ISHA-1). The primary objective of the ISHA-1 capsule design is to deliver to Idaho National Lab (INL) a semi-universal drop-in capsule that can facilitate the irradiation of both fissile and structural materials in a variety of ATR positions. This irradiation experiment will support the need for development of Accelerated Fuel Qualification (AFQ) methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hierarchical Gaussian process-based Bayesian optimization for materials discovery in high entropy alloy spaces

Bayesian optimization (BO) is a powerful and data-efficient method for iterative materials discovery and design, particularly valuable when prior knowledge is limited, underlying functional relationships are complex or unknown, and the cost of querying the materials space is significant. Traditional BO methodologies typically utilize conventional Gaussian Processes (cGPs) to model the relationships between material inputs and properties, as well as correlations within the input space. However, cGP-BO approaches often fall short in multi-objective optimization scenarios, where they are unable to fully exploit correlations between distinct material properties. Leveraging these correlations can significantly enhance the discovery process, as information about one property can inform and improve predictions about others. Here, this study addresses this limitation by employing advanced kernel structures to capture and model multi-dimensional property correlations through multi-task (MTGPs) or deep Gaussian Processes (DGPs), thus accelerating the discovery process. We demonstrate the effectiveness of MTGP-BO and DGP-BO in rapidly and robustly solving complex materials design challenges that occur within the context of complex multi-objective optimization over FCC FeCrNiCoCu high entropy alloy (HEA) spaces, where traditional cGP-BO approaches fail. Furthermore, we highlight how the differential costs associated with querying various material properties can be strategically leveraged to make the materials discovery process more cost-efficient.

36 MATERIALS SCIENCE↗

Scalable Static and Dynamic Community Detection Using Grappolo

Graph clustering, popularly known as community detection, is a fundamental kernel for several applications of relevance to the Defense Advanced Research Projects Agency’s (DARPA) Hierarchical Identify Verify Exploit (HIVE) Pro- gram. Clusters or communities represent natural divisions within a network that are densely connected within a cluster and sparsely connected to the rest of the network. The need to compute clustering on large scale data necessitates the development of efficient algorithms that can exploit modern architectures that are fundamentally parallel in nature. How- ever, due to their irregular and inherently sequential nature, many of the current algorithms for community detection are challenging to parallelize. In response to the HIVE Graph Challenge, we present several parallelization heuristics for fast community detection using the Louvain method as the serial template. We implement all the heuristics in a software library called Grappolo. Using the inputs from the HIVE Challenge, we demonstrate superior performance and high quality solutions based on four parallelization heuristics. We use Grappolo on static graphs as the first step towards community detection on streaming graphs.

Community Detection↗

Linking spout fluidization hydrodynamics to pyrolytic carbon deposition characteristics in a fluidized bed chemical vapor deposition reactor

Spout fluidized bed chemical vapor deposition (SFB-CVD) is the dominant method for producing pyrolytic carbon (PyC) coatings on tristructural-isotropic (TRISO) fuel particles, yet the relationship between gas injector design, fluidization hydrodynamics, and resulting coating quality remains poorly quantified. Here, in this work, three spout fluidized bed (SFB) nozzle geometries were designed and fabricated to empirically investigate how injector-driven changes in particle circulation influence PyC deposition. The geometries were first evaluated in a room temperature fluidization apparatus using time-resolved particle image velocimetry, which highlighted distinct differences in particle velocity fields, circulation pathways, and overall fluidization quality. Graphite versions of each injector geometry were subsequently implemented in a laboratory-scale SFB-CVD reactor to deposit PyC onto surrogate fuel kernels under similar conditions. Post-deposition characterization included particle morphology, coating thickness, porosity distribution, optical anisotropy, and microindentation mechanical testing. Overall, the results show clear differences in coating microstructure as a function of changing injector geometry, despite mechanical testing indicating comparable elastic modulus values across all coatings. This study provides one of the first fully experimental, quantitative mappings between SFB nozzle geometry, fluidization hydrodynamics, and resulting PyC coating structure. The framework established here supports rational injector design and offers a pathway toward improved coating control in future pilot- and production-scale TRISO fuel fabrication systems.

Coated particle fuel↗

TU-F-18C-07: Hardware Advances for MTF Improvement in Dedicated Breast CT

Purpose: In this study, we have designed and implemented a prototype dedicated breast CT system (bCT) to improve the spatial resolution characteristics, in order to improve detection of micro-calcifications. Methods: A 10.8 kW water-cooled, tungsten anode x-ray tube, running up to 240 mA at 60 kV, coupled with an x-ray generator specifically designed for this application, and 0.3 mm of added copper filter was used to generate x-ray pulses. A CsI CMOS flat panel detector with a pixel pitch of 0.075 mm in native binning mode was used. The system geometry was designed in a way to achieve an FOV on par with similar bCT prototypes, resulting in a magnification factor of 1.39. A 0.013 mm tungsten wire was used to generate point spread functions. Multiple scans were performed with different numbers of projections, different reconstruction kernel sizes and different reconstruction filters to study the effects of each parameter on MTF. The resulting MTFs were then evaluated quantitatively using the generated PFSs. Duplicate scans with the same parameters were performed on two other dedicated breast CT systems to compare the performance of the new prototype. Results: The results of the MTF experiments demonstrate a significant improvement in the spatial resolution characteristics. In the new prototype, using the pulsed x-ray source results in a restoration of the azimuthal MTF degradation, due to motion blurring previously seen in other bCT systems. Moreover, employing the higher resolution x-ray detector considerably improves the MTF. The MTF at 10% of the new system is at 3.5 1/mm, a factor of 4.36 greater than an earlier bCT scanner. Conclusion: The MTF analysis of the new prototype bCT shows that using the new hardware and control results in a significant improvement in visualization of finer detail. This suggests that the visualization of micro-calcifications will be significantly improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Anomalies in Time Series Using Kernel Density Approaches

This paper introduces a novel anomaly detection approach tailored for time series data with exclusive reliance on normal events during training. Our key innovation lies in the application of kernel-density estimation (KDE) to scrutinize reconstruction errors, providing an empirically derived probability distribution for normal events post-reconstruction. This non-parametric density estimation technique offers a nuanced understanding of anomaly detection, differentiating it from prevalent threshold-based mechanisms in existing methodologies. In post-training, events are encoded, decoded, and evaluated against the estimated density, providing a comprehensive notion of normality. In addition, we propose a data augmentation strategy involving variational autoencoder-generated events and a smoothing step for enhanced model robustness. The significance of our autoencoder-based approach is evident in its capacity to learn normal representation without prior anomaly knowledge. Through the KDE step on reconstruction errors, our method addresses the versatility of anomalies, departing from assumptions tied to larger reconstruction errors for anomalous events. Our proposed likelihood measure then distinguishes normal from anomalous events, providing a concise yet comprehensive anomaly detection solution. The extensive experimental results support the feasibility of our proposed method, yielding significantly improved classification performance by nearly 10% on the UCR benchmark data.

Frehner, Robin↗

SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

60 APPLIED LIFE SCIENCES↗

TU-F-18A-09: CT Number Stability Across Patient Sizes Using Virtual-Monoenergetic Dual-Energy CT

Purpose: Virtual-monoenergetic imaging uses dual-energy CT data to synthesize images corresponding to a single photon energy, thereby reducing beam-hardening artifacts. This work evaluated the ability of a commercial virtual-monoenergetic algorithm to achieve stable CT numbers across patient sizes. Methods: Test objects containing a range of iodine and calcium hydroxyapatite concentrations were placed inside 8 torso-shaped water phantoms, ranging in lateral width from 15 to 50 cm, and scanned on a dual-source CT system (Siemens Somatom Force). Single-energy scans were acquired from 70-150 kV in 10 kV increments; dual-energy scans were acquired using 4 energy pairs (low energy: 70, 80, 90, and 100 kV; high energy: 150 kV + 0.6 mm Sn). CTDIvol was matched for all single- and dual-energy scans for a given phantom size. All scans used 128×0.6 mm collimation and were reconstructed with 1-mm thickness at 0.8-mm increment and a medium smooth body kernel. Monoenergetic images were generated using commercial software (syngo Via Dual Energy, VA30). Iodine contrast was calculated as the difference in mean iodine and water CT numbers from respective regions-of-interest in 10 consecutive images. Results: CT numbers remained stable as phantom width varied from 15 to 50 cm for all dual-energy data sets (except for at 50 cm using 70/150Sn due to photon starvation effects). Relative to the 15 cm phantom, iodine contrast was within 5.2% of the 70 keV value for phantom sizes up to 45 cm. At 90/150Sn, photon starvation did not occur at 50 cm, and iodine contrast in the 50-cm phantom was within 1.4% of the 15-cm phantom. Conclusion: Monoenergetic imaging, as implemented in the evaluated commercial system, eliminated the variation in CT numbers due to patient size, and may provide more accurate data for quantitative tasks, including radiation therapy treatment planning. Siemens Healthcare.

07 ISOTOPE AND RADIATION SOURCES↗

Key results from irradiation and post-irradiation examination of AGR-1 UCO Triso fuel - 18576

The AGR-1 irradiation experiment was performed as the first test of tri-structural isotropic (TRISO) fuel in the US Advanced Gas Reactor Fuel Development and Qualification Program. The experiment consisted of 72 right cylinder fuel compacts containing approximately 3 x 10{sup 5} coated fuel particles with uranium oxide/uranium carbide (UCO) fuel kernels. The fuel was irradiated in the Advanced Test Reactor for a total of 620 effective full power days. Fuel burnup ranged from 11.3 to 19.6% fissions per initial metal atom and time average, volume average irradiation temperatures of the individual compacts ranged from 955 to 1136 deg. C. This paper focuses on key results from the irradiation and post-irradiation examination, which revealed a robust fuel with excellent performance characteristics under the conditions tested and have significantly improved the understanding of UCO coated particle fuel irradiation behavior. The fuel exhibited zero TRISO coating failures (failure of all three dense coating layers) during irradiation and post-irradiation safety testing at temperatures up to 1700 deg. C. Advanced PIE methods have allowed particles with SiC coating failure that were discovered to be present in a very-low population to be isolated and meticulously examined, which has elucidated the specific causes of SiC failure in these specimens. The level of fission product release from the fuel during irradiation and post-irradiation safety testing has been studied in detail. Results indicated very low release of krypton and cesium through intact SiC and modest release of europium and strontium, while also confirming the potential for significant silver release through the coatings depending on irradiation conditions. Focused study of fission products within the coating layers of irradiated particles down to nanometer length scales has provided new insights into fission product transport through the coating layers and the role various fission products may have on coating integrity. The broader implications of these results and the application of lessons learned from AGR-1 to fuel fabrication and post-irradiation examination for subsequent fuel irradiation experiments as part of the US fuel program are also discussed. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GPU implementation of the linear scaling three dimensional fragment method for large scale electronic structure calculations

LS3DF, namely linear scaling three-dimensional fragment method, is an efficient linear scaling ab initio total energy electronic structure calculation code based on a divide-and-conquer strategy. In this paper, we present our GPU implementation of the LS3DF code. Our test results show that the GPU code can calculate systems with about ten thousand atoms fully self-consistently in the order of 10 min using thousands of computing nodes. This makes the electronic structure calculations of 10,000-atom nanosystems routine work. This speed is 4.5–6 times faster than the CPU calculations using the same number of nodes on the Titan machine in the Oak Ridge leadership computing facility (OLCF). Such speedup is achieved by (a) carefully re-designing of the computationally heavy kernels; (b) redesign of the communication pattern for heterogeneous supercomputers.

Computer Science↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

Reionization effective likelihood from Planck 2018 data

We release relike (reionization effective likelihood), a fast and accurate effective likelihood code based on the latest Planck 2018 data that allows one to constrain any model for reionization between 6 < z < 30 using five constraints from the CMB reionization principal components (PC). We tested the code on two example models which showed excellent agreement with sampling the exact Planck likelihoods using either a simple Gaussian PC likelihood or its full kernel density estimate. This code enables a fast and consistent means for combining Planck constraints with other reionization data sets, such as kinetic Sunyaev-Zeldovich effects, line-intensity mapping, luminosity function, star formation history, quasar spectra, etc., where the redshift dependence of the ionization history is important. Since the PC technique tests any reionization history in the given range, we also derive model-independent constraints for the total Thomson optical depth τ PC = $0.0619$$^{+0.0056}_{–0.0068}$ and its 15 ≤ z ≤ 30 high redshift component τ PC (15,30) < 0.020 (95% C.L.). Furthermore, the upper limits on the high-redshift optical depth is a factor of ~3 larger than those reported in the Planck 2018 cosmological parameter paper using the FlexKnot method and we validate our results with a direct analysis of a two-step model which permits this small high-z component.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification

Purpose: To develop a computer-aided detection (CADe) scheme for nodules in chest radiographs (CXRs) with a high sensitivity and a low false-positive (FP) rate. Methods: The authors developed a CADe scheme consisting of five major steps, which were developed for improving the overall performance of CADe schemes. First, to segment the lung fields accurately, the authors developed a multisegment active shape model. Then, a two-stage nodule-enhancement technique was developed for improving the conspicuity of nodules. Initial nodule candidates were detected and segmented by using the clustering watershed algorithm. Thirty-one shape-, gray-level-, surface-, and gradient-based features were extracted from each segmented candidate for determining the feature space, including one of the new features based on the Canny edge detector to eliminate a major FP source caused by rib crossings. Finally, a nonlinear support vector machine (SVM) with a Gaussian kernel was employed for classification of the nodule candidates. Results: To evaluate and compare the scheme to other published CADe schemes, the authors used a publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs. The CADe scheme based on the SVM classifier achieved sensitivities of 78.6% (110/140) and 71.4% (100/140) with averages of 5.0 (1165/233) FPs/image and 2.0 (466/233) FPs/image, respectively, in a leave-one-out cross-validation test, whereas the CADe scheme based on a linear discriminant analysis classifier had a sensitivity of 60.7% (85/140) at an FP rate of 5.0 FPs/image. For nodules classified as ''very subtle'' and ''extremely subtle,'' a sensitivity of 57.1% (24/42) was achieved at an FP rate of 5.0 FPs/image. When the authors used a database developed at the University of Chicago, the sensitivities was 83.3% (40/48) and 77.1% (37/48) at an FP rate of 5.0 (240/48) FPs/image and 2.0 (96/48) FPs /image, respectively. Conclusions: These results compare favorably to those described for other commercial and noncommercial CADe nodule detection systems.

60 APPLIED LIFE SCIENCES↗

Extending XACC for Quantum Optimal Control

Quantum computing vendors are beginning to open up application programming interfaces for direct pulse-level quantum control. With this, programmers can begin to describe quantum kernels of execution via sequences of arbitrary pulse shapes. This opens new avenues of research and development with regards to smart quantum compilation routines that enable direct translation of higher-level digital assembly representations to these native pulse instructions. In this work, we present an extension to the XACC system-level quantum-classical software framework that directly enables this compilation lowering phase via user-specified quantum optimal control techniques. This extension enables the translation of digital quantum circuit representations to equivalent pulse sequences that are optimal with respect to the backend system dynamics. Our work is modular and extensible, enabling third party optimal control techniques and strategies in both C++ and Python. We demonstrate this extension with familiar gradient-based methods like gradient ascent pulse engineering (GRAPE), gradient optimization of analytic controls (GOAT), and Krotov's method. Our work serves as a foundational component of future quantum-classical compiler designs that lower high-level programmatic representations to low-level machine instructions.

Nguyen, Thien↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

Hamiltonian Approach to Yang-Mills Theory in Coulomb Gauge--Revisited

I briefly review results obtained within the variational Hamiltonian approach to Yang-Mills theory in Coulomb gauge and confront them with recent lattice data. The variational approach is extended to non-Gaussian wave functionals including three- and four-gluon kernels in the exponential of the vacuum wave functional and used to calculate the three-gluon vertex. A new functional renormalization group flow equation for Hamiltonian Yang-Mills theory in Coulomb gauge is solved for the gluon and ghost propagator under the assumption of ghost dominance. The results are compared to those obtained in the variational approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗