Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Shotgun Immunoproteomic Approach for the Discovery of Linear B-Cell Epitopes in Biothreat Agents Francisella tularensis and Burkholderia pseudomallei

Peptide-based subunit vaccines are coming to the forefront of current vaccine approaches, with safety and cost-effective production among their top advantages. Peptide vaccine formulations consist of multiple synthetic linear epitopes that together trigger desired immune responses that can result in robust immune memory. The advantages of linear compared to conformational epitopes are their simple structure, ease of synthesis, and ability to stimulate immune responses by means that do not require complex 3D conformation. Prediction of linear epitopes through use of computational tools is fast and cost-effective, but typically of low accuracy, necessitating extensive experimentation to verify results. On the other hand, identification of linear epitopes through experimental screening has been an inefficient process that requires thorough characterization of previously identified full-length protein antigens, or laborious techniques involving genetic manipulation of organisms. In this study, we apply a newly developed generalizable screening method that enables efficient identification of B-cell epitopes in the proteomes of pathogenic bacteria. As a test case, we used this method to identify epitopes in the proteome of Francisella tularensis (Ft), a Select Agent with a well-characterized immunoproteome. Our screen identified many peptides that map to known antigens, including verified and predicted outer membrane proteins and extracellular proteins, validating the utility of this approach. We then used the method to identify seroreactive peptides in the less characterized immunoproteome of Select Agent Burkholderia pseudomallei (Bp). This screen revealed known Bp antigens as well as proteins that have not been previously identified as antigens. Although B-cell epitope prediction tools Bepipred 2.0 and iBCE-EL classified many of our seroreactive peptides as epitopes, they did not score them significantly higher than the non-reactive tryptic peptides in our study, nor did they assign higher scores to seroreactive peptides from known Ft or Bp antigens, highlighting the need for experimental data instead of relying on computational epitope predictions alone. The present workflow is easily adaptable to detecting peptide targets relevant to the immune systems of other mammalian species, including humans (depending upon the availability of convalescent sera from patients), and could aid in accelerating the discovery of B-cell epitopes and development of vaccines to counter emerging biological threats.

60 APPLIED LIFE SCIENCES↗

Electron- and positron-proton elastic scattering in CLAS

There is a significant disagreement between measurements of the proton electric form factor, G{sup p}{sub E}, using Rosenbluth separations and polarization transfer. This disagreement, if not explained, could pose a fundamental challenge to our understanding of electron scattering or proton structure. Two-photon exchange (TPE) processes, although not fully calculable, are the most likely explanation of this disagreement. We will definitively test this assertion by comparing the electron-proton and positron-proton elastic scattering cross section in the Jefferson Lab CLAS. We will make a mixed identical electron and positron tertiary beam by passing a 5.5 GeV primary electron beam through a radiator to make a photon beam and then passing the photon beam through a converter to make electron-positron pairs. Measuring the elastic cross sections simultaneously using identical lepton beams should significantly reduce systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Product Detection of the CH Radical Reactions with Ammonia and Methyl-Substituted Amines

In this work, reactions of the methylidyne (CH) radical with ammonia (NH 3 ), methylamine (CH 3 NH 2 ), dimethylamine ((CH 3 ) 2 NH), and trimethylamine ((CH 3 ) 3 N) have been investigated under multiple collision conditions at 373 K and 4 Torr. The reaction products are detected by using soft photoionization coupled to orthogonal acceleration time-of-flight mass spectrometry at the Advanced Light Source (ALS) synchrotron. Kinetic traces are employed to discriminate between CH reaction products and products from secondary or slower reactions. Branching ratios for isomers produced at a given mass and formed by a single reaction are obtained by fitting the observed photoionization spectra to linear combinations of pure compound spectra. The reaction of the CH radical with ammonia is found to form mainly imine, HN$=$CH 2 , in line with an addition–elimination mechanism. The singly methyl-substituted imine is detected for the CH reactions with methylamine, dimethylamine, and trimethylamine. Dimethylimine isomers are formed by the reaction of CH with dimethylamine, while trimethylimine is formed by the CH reaction with trimethylamine. Overall, the temporal profiles of the products are not consistent with the formation of aminocarbene products in the reaction flow tube. In the case of the reactions with methylamine and dimethylamine, product formation is assigned to an addition–elimination mechanism similar to that proposed for the CH reaction with ammonia. However, this mechanism cannot explain the products detected by the reaction with trimethylamine. A C—H insertion pathway may become more probable as the number of methyl groups increases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

SU-E-T-542: Comparison of Stereotactic Radiosurgery (SRS) of Brain Lesions Using Gamma Knife, VMAT, IMRT, and Conformal Arcs

Purpose: To compare dose distributions in stereotactic radiation surgery of brain lesions using gamma Knife, VMAT, conformal arcs, and IMRT in order to provide an optimal treatment. Methods: Dose distributions from single shot of 4C model of Gamma Knife at the helmet collimation sizes of 4, 8, 14, and 18 mm in diameter were compared with full arcs with the square shapes of 4×4 (or 5×5), 8×8 (or 10×10), and spherical shapes of 16 or 20 mm in diameter using EDR3 films in the same gamma knife QA phantom. Plans for ten SRS cases with single and multiple lesions were created in gamma knife plans and Pinnacle plans. The external beam plans had enlarged field size by 2-mm and used single conformal full circle arc for solitary lesion and none coplanar arcs/beams for multiple lesions. Coverage, conformity index, dose to critical organs, and integral dose to the brain and nearby critical structures were compared on all plans. Structures and dose matrices were registered in a Velocity deformable image registration system. Results: Single full circle arc from Elekta beam-modulate MLC (4-mm leaf thickness) and agility MLC (5-mm leaf thickness) have larger penumbra and less flatness than that of Gamma Knife single shot. None-coplanar arcs or beams were required to achieve similar dose distribution. In general, Gamma Knife plans provided significant less integral dose than that of linac-based plans. Benefits of IMRT and VMAT versus gamma Knife and conformal arcs were not significant. Conclusion: Our dose measurement and treatment planning evaluation clearly demonstrated dose distribution differences amount current popular SRS modalities for small solitary and multiple brain lesions. The trend of using MLC shape beams or arcs to replace conventional cones should be revisited in order to keep lower integral dose if the late correlates with some radiation-induced side effects. Pilot grant from Elekta LLC.

60 APPLIED LIFE SCIENCES↗

Colossal magnetoresistance from spin-polarized polarons in an Ising system

Recent experiments suggest a new paradigm toward novel colossal magnetoresistance (CMR) in a family of materials EuM 2 X 2 (M = Cd, In, Zn; X = P, As), distinct from the traditional avenues involving Kondo–Ruderman–Kittel–Kasuya–Yosida crossovers, magnetic phase transitions with structural distortions, or topological phase transitions. Here, we use angle-resolved photoemission spectroscopy and density functional theory calculations to explore their origin, particularly focusing on EuCd 2 P 2 . While the low-energy spectral weight royally tracks that of the resistivity anomaly near the temperature with maximum magnetoresistance ( T MR ) as expected from transport-spectroscopy correspondence, the spectra are completely incoherent and strongly suppressed with no hint of a Landau quasiparticle. Using systematic material and temperature dependence investigation complemented by theory, we attribute this nonquasiparticle caricature to the strong presence of entangled magnetic and lattice interactions, a characteristic enabled by the p - f mixing. Given the known presence of ferromagnetic clusters, this naturally points to the origin of CMR being the scattering of spin-polarized polarons at the boundaries of ferromagnetic clusters. These results are not only illuminating to investigate the strong correlations and topology in EuCd 2 X 2 family, but, in a broader view, exemplify how multiple cooperative interactions can give rise to extraordinary behaviors in condensed matter systems.

36 MATERIALS SCIENCE↗

Preliminary Design of a Bunching System for the CLIC Polarized Electron Source

Major parameters of the CLIC and ILC electron sources are given in Table I. It is shown that the CLIC source needs to provide 312 15-ps-long 2-GHz microbunches. There are two approaches to achieve the time structure [2]: one is to develop a 2-GHz optical pulse train, and the other to develop a 156-ns-long CW optical pulse and use an RF bunching system to generate 312 2-GHz microbunches. The former scheme may ease the RF bunching system but still need it to bunch 100-ps of microbunch down to 15-ps level. Otherwise, a huge amount of energy spread is accumulated when the beam is accelerated through downstream 2-GHz accelerator. In addition, in the former scheme, the space charge is high and surface charge is not yet proven in the parameter regime and 2-GHz mode locked laser is challenging. The latter scheme needs a high-efficiency bunching system to generate 312 15-ps microbunches with 2-GHz repetition rate but it has some notable advantages: a 156-ns CW laser technique is matured, and the charge limit behavior in the scheme is better characterized than that in the former case, as listed in the table. This note presents a design and modeling of the bunching system for the latter scheme to convert a 156-ns CW pulse to 312 15-ps long 2-GHz microbunches.

43 PARTICLE ACCELERATORS↗

SU-E-T-142: Automatic Linac Log File: Analysis and Reporting

Purpose: End to end QA for IMRT/VMAT is time consuming. Automated linac log file analysis and recalculation of daily recorded fluence, and hence dose, distribution bring this closer. Methods: Matlab (R2014b, Mathworks) software was written to read in and analyse IMRT/VMAT trajectory log files (TrueBeam 1.5, Varian Medical Systems) overnight, and are archived on a backed-up network drive (figure). A summary report (PDF) is sent by email to the duty linac physicist. A structured summary report (PDF) for each patient is automatically updated for embedding into the R&V system (Mosaiq 2.5, Elekta AG). The report contains cross-referenced hyperlinks to ease navigation between treatment fractions. Gamma analysis can be performed on planned (DICOM RTPlan) and treated (trajectory log) fluence distributions. Trajectory log files can be converted into RTPlan files for dose distribution calculation (Eclipse, AAA10.0.28, VMS). Results: All leaf positions are within +/−0.10mm: 57% within +/−0.01mm; 89% within 0.05mm. Mean leaf position deviation is 0.02mm. Gantry angle variations lie in the range −0.1 to 0.3 degrees, mean 0.04 degrees. Fluence verification shows excellent agreement between planned and treated fluence. Agreement between planned and treated dose distribution, the derived from log files, is very good. Conclusion: Automated log file analysis is a valuable tool for the busy physicist, enabling potential treated fluence distribution errors to be quickly identified. In the near future we will correlate trajectory log analysis with routine IMRT/VMAT QA analysis. This has the potential to reduce, but not eliminate, the QA workload.

60 APPLIED LIFE SCIENCES↗

Search for the Z(4430) at BABAR

We report the results of a search for Z(4430){sup -} decay to J/{psi}{pi}{sup -} or {psi}(2S){pi}{sup -} in B{sup -,0} {yields} J/{psi}{pi}{sup -} K{sup 0,+} and B{sup -,0} {yields} {psi}(2S){pi}{sup -}K{sup 0,+} decays. The data were collected with the BABAR detector at the SLAC PEP-II asymmetric-energy e{sup +}e{sup -} collider operating at center of mass energy 10.58 GeV, and the sample corresponds to an integrated luminosity of 413 fb{sup -1}. Each K{pi}{sup -} mass distribution exhibits clear K*(892) and K*{sub 2}(1430) signals, and the efficiency-corrected spectrum is well-described by a superposition of the associated Breit-Wigner intensity distributions, together with an S-wave contribution obtained from the LASS I = 1/2 K{pi}{sup -} scattering amplitude measurements. Each K{pi}{sup -} angular distribution varies significantly in structure with K{pi}{sup -} mass, and is represented in terms of low-order Legendre polynomial moments. We find that each J/{psi}{pi}{sup -} or {psi}(2S){pi}{sup -} mass distribution is well-described by the reflection of the measured K{pi}{sup -} mass and angular distribution structures. We see no significant evidence for a Z(4430){sup -} signal for any of the processes investigated, neither in the total J/{psi}{pi}{sup -} or {psi}(2S){pi}{sup -} mass distribution, nor in the corresponding distributions for the regions of K{pi}{sup -} mass for which observation of the Z(4430){sup -} signal was reported. We obtain branching fraction upper limits {Beta}(B{sup -} {yields} Z{sup -}{bar K}{sup 0}, Z{sup -} {yields} J/{psi}{pi}{sup -}) < 1.5 x 10{sup -5}, {Beta}(B{sup 0} {yields} Z{sup -}K{sup +},Z{sup -} {yields} J/{psi}{pi}{sup -}) < 0.4 x 10{sup -5}, {Beta}(B{sup -} {yields} Z{sup -} {bar K}{sup 0}, Z{sup -} {yields} {psi}(2S){pi}{sup -}) > 4.7 x 10{sup -5}, and {Beta}(B{sup 0} {yields} Z{sup -} K{sup +}, Z{sup -} {yields} {psi}(2S){pi}{sup -}) < 3.1 x 10{sup -5} at 95% confidence level, where the Z(4430){sup -} mass and width have been fixed to be reported central values.

43 PARTICLE ACCELERATORS↗

Belle II Detector: status and proposed US contributions

Conference proceedings for the 2012 American Physical Society, Division of Particles and Fields (DPF2012) conference. Paper is on the US contibutions to the Belle II detector upgrade. High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector and upgraded KEKB accelerator. The status of the Belle II detector and proposed role of the US Belle II collaborators are presented in this article. The B factory experiments, Belle at the KEKB collider at KEK and BaBar at the PEP II collider at SLAC, were built to measure the large mixing-induced CP violation in the B0 system predicted by the theory of Kobayashi and Maskawa. The successful confirmation of the prediction led to the Nobel Prize for both theorists. The B factories were built to answer the question Is the CKM description in the Standard Model correct? Most B factory results are in good agreement with the expectations from the Standard Model (SM) and confirm the CKM structure of quark mixing and CP violation, but some measurements show tensions with the SM prediction. The Super B factories will address the question In what way is the Standard Model wrong? Much larger datasets are needed for high-precision measurements to search for significant deviations from the SM which are expected to exist. The SuperKEKB and Belle II detector are being constructed to perform these high precision studies with a dataset 50ab{sup -1}. The SuperKEKB accelerator will operate at an instantaneous luminosity of 8 x 10{sup 35}cm{sup -2}s{sup -1}, a factor of 40 times higher than the luminosity of the KEKB accelerator at the end of the Belle physics program. The increased luminosity will derive primarily from shrinking the beam size at the interaction point (nano beams) utilizing new final focus quadrapole magnets in combination with a factor of 2 increase in beam currents. To counteract the increase in the beam-beam parameter due to the reduced beta functions, the beam emittance must also be reduced; this will be achieved with a new electron source and a new damping ring.

43 PARTICLE ACCELERATORS↗

Irradiation in the Swiss Spallation Neutron Source and its Applications

In high power (∼ 1 MW or higher) spallation targets being operated or developed for different attractive applications such as neutron scattering science and technology or accelerator driven systems (ADS) for nuclear waste transmutation, both target and structural materials are exposed to intensive irradiation of high energy protons and spallation neutrons. Since spallation reactions induced by high energy protons can produce helium (He) and hydrogen (H) and other transmutation elements at very high rates, the behavior of materials used in a spallation irradiation environment can be much different from those observed from materials irradiated with neutrons in fission reactors. Therefore, the damage induced by spallation irradiation cannot be simply simulated by fission neutron irradiation experiments. Seven irradiation experiments have been conducted in the targets of the Swiss Spallation Neutron Source (SINQ) at the Paul Scherrer Institute (PSI) since 1998 within a broad international collaboration with Commissariat a L'energie Atomique Centre d'Etudes de Saclay (CEA), Forschungszentrum Juelich (FZJ), Japan Atomic Energy Agency (JAEA), Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), University California Santa Barbara (UCSB) and several institutes of Chinese Academy of Sciences. More than 7000 samples from various Al-, Ti-, Fe-, Ni-, Zr-, and W-alloys and SiC/SiC, C/SiC and MAX-phase ceramics composites have been irradiated to doses up to ∼25 dpa (in Fe) and ∼2000 appm He at temperatures up to ∼800 deg. C. In addition, quite many specimens were irradiated in contact with stagnant liquid metals such as Hg, PbBi, PbLi etc. Dedicated post-irradiation examinations (PIE) have been performed, together with the international collaborators. Various mechanical tests including tensile, bend, Charpy-impact, small punch and hardness have been carried out to obtain the mechanical properties of the materials after irradiation. The microstructural changes in the irradiated specimens have been investigated by means of transmission electron microscopy, positron annihilation spectroscopy, atom probe tomography etc. Many novel results have been obtained from the PIE conducted by PSI and other STIP partner laboratories. The DBTT-shift of different FM steels increases more or less linearly with dose after irradiation in the SINQ target, while it saturates at a level of few dpa in fission neutron irradiation cases. This phenomenon can be mostly attributed to helium effects. In addition to the strong embrittlement effect, pronounced hardening effect was also detected in high dose specimens, which was contributed by high density helium bubbles.

36 MATERIALS SCIENCE↗

SU-G-TeP4-09: Development of a Plan Data Aggregator for Time Efficient Physics Second-Checks of Machine Parameters for External Beam Treatment Plans

Purpose: Physics second-checks for external beam radiation therapy are performed, in-part, to verify that the machine parameters in the Record-and-Verify (R&V) system that will ultimately be sent to the LINAC exactly match the values initially calculated by the Treatment Planning System (TPS). While performing the second-check, a large portion of the physicists’ time is spent navigating and arranging display windows to locate and compare the relevant numerical values (MLC position, collimator rotation, field size, MU, etc.). Here, we describe the development of a software tool that guides the physicist by aggregating and succinctly displaying machine parameter data relevant to the physics second-check process. Methods: A data retrieval software tool was developed using Python to aggregate data and generate a list of machine parameters that are commonly verified during the physics second-check process. This software tool imported values from (i) the TPS RT Plan DICOM file and (ii) the MOSAIQ (R&V) Structured Query Language (SQL) database. The machine parameters aggregated for this study included: MLC positions, X&Y jaw positions, collimator rotation, gantry rotation, MU, dose rate, wedges and accessories, cumulative dose, energy, machine name, couch angle, and more. Results: A GUI interface was developed to generate a side-by-side display of the aggregated machine parameter values for each field, and presented to the physicist for direct visual comparison. This software tool was tested for 3D conformal, static IMRT, sliding window IMRT, and VMAT treatment plans. Conclusion: This software tool facilitated the data collection process needed in order for the physicist to conduct a second-check, thus yielding an optimized second-check workflow that was both more user friendly and time-efficient. Utilizing this software tool, the physicist was able to spend less time searching through the TPS PDF plan document and the R&V system and focus the second-check efforts on assessing the patient-specific plan-quality.

60 APPLIED LIFE SCIENCES↗

Advanced spectroscopic synchrotron techniques to unravel the intrinsic properties of dilute magnetic oxides : the case of Co:ZnO.

The use of synchrotron-based spectroscopy has revolutionized the way we look at matter. X-ray absorption spectroscopy (XAS) using linear and circular polarized light offers a powerful toolbox of element-specific structural, electronic and magnetic probes that is especially well suited for complex materials containing several elements. We use the specific example of Zn{sub 1-x}Co{sub x}O (Co:ZnO) to demonstrate the usefulness of combining these XAS techniques to unravel its intrinsic properties. We demonstrate that as long as phase separation or excessive defect formation is absent, Co:ZnO is paramagnetic. We can establish quantitative thresholds based on four reliable quality indicators using XAS; samples that show ferromagnet-like behaviour fail to meet these quality indicators, and complementary experimental techniques indeed prove phase separation. Careful analysis of XAS spectra is shown to provide quantitative information on the presence and type of dilute secondary phases in a highly sensitive, non-destructive manner.

43 PARTICLE ACCELERATORS↗

Tracks to therapy

Studies of the structure of particle tracks have led to models of track effects based on radial dose and radiobiological target theory that have been very successful in describing and predicting track effects in physical, chemical, and biological systems. For describing mammalian cellular inactivation two inactivation modes are required, called gamma-kill and ion-kill, the first due to synergistic effects of delta rays from adjacent ion paths thus resembling the effects from gamma rays, and the second to the effects of single ion transits through a cell nucleus. The ion-kill effect is more severe, where the fraction of cells experiencing ion kill is responsible for a decrease in the oxygen enhancement ratio, and an increase in relative biological effectiveness, but these are accompanied by loss of repair, hence to a reduction in the efficiency of fractionation in high LET therapy, as shown by our calculations for radiobiological effects in the "spread out Bragg Peak".

Review, Tutorial↗

Simultaneous Incorporation of Cr, Zn, Cd, and Pb in the Goethite Structure

In order to improve our understanding of how the goethite crystal structure is affected by the incorporation of metals (and by variations in the amount of the incorporation), and to review any possible synergistic and antagonistic effects of co-metals, the present investigation focused on the incorporation of multiple (di-, tri-, and tetra-) metals, i.e. Cr, Zn, Cd, and Pb, in the goethite crystallographic structure. A series of single- and multi-metal M-Cr/Zn/Cd/Pb-substituted goethites with M/(M+Fe) molar ratios = 0.10 were prepared. The general sequence of metal entry in single-metal substituted goethites was Zn = Cr > Cd > Pb and in multi-metal-substituted goethites was Zn > Cr {ge} Cd > Pb. Simultaneous incorporation of Cr, Zn, Cd, and Pb up to 10.5 mole % was achieved in goethite. Synchrotron X-ray diffraction and extended X-ray absorption fine structure (EXAFS) techniques were employed to assess the structural characteristics of the synthesis products. Rietveld refinement of XRD data showed small changes in unit-cell parameters and Fe/M-Fe/M distances due to M substitution(s). A typical goethite-like crystalline structure remained intact, however. The unit-cell parameters were mutually, linearly correlated, though Fe/M-Fe/M distances were not, indicating that complex changes occurred at the local scale. In single-metal substituted goethites, incorporation of Cr reduced the unit-cell volume by 0.13% while that of Zn, Cd, and Pb increased it by 1.09, 3.58, and 0.56%, respectively. The changes in multi-metal-substituted goethites appeared to be the complex combination of that of the individually incorporated metals. The X-ray absorption near edge structure study of Pb-substituted goethites showed that the majority of associated Pb was Pb{sup 2+}, while Pb{sup 4+} was preferred over Pb{sup 2+} in the bulk structure. Measurements by EXAFS at the Fe K-edge indicated that the Fe polyhedra contracted in the presence of Cd{sup 2+} and Pb{sup 2+}, providing room for the substitution of larger cations. Measurements by EXAFS at the Cr and Cd K-edges indicated symmetric Cr/Cd polyhedra with single Cr/Cd-O distances and, at Fe and Zn K-edges and the Pb LIII-edge, indicated asymmetric polyhedra with two sets of Fe/Zn/Pb-O distances. The Zn octahedra were possibly Zn(OH){sub 4}O{sub 2}, which enlarged the metal-metal corner-sharing distance to 3.86 {angstrom}. This configuration of ligands around the Zn{sup 2+} cation might occur to balance local charges. Symmetric polyhedra appeared to reduce steric strains in the structure, compared to the asymmetric polyhedra. The result was that Cr enhanced the incorporation of Zn, Cd, and Pb, while the converse was true for Zn.

36 MATERIALS SCIENCE↗

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.

42 ENGINEERING↗

Mechanism of O 2 Activation and Cysteine Oxidation by the Unusual Mononuclear Cu(I) Active Site of the Formylglycine-Generating Enzyme

The formylglycine-generating enzyme (FGE) catalyzes the selective oxidation of a peptidyl-cysteine to form formylglycine, a critical cotranslational modification for type I sulfatase activation and a useful bioconjugation handle. Previous studies have shown that the substrate peptidyl-cysteine binds to the linear bis-thiolate Cu(I) site of FGE to form a trigonal planar tris-thiolate Cu(I) structure that activates O 2 for the oxidation of the C β –H of the cysteine substrate via an unknown mechanism. Here, we employed a combination of stopped-flow kinetic, spectroscopic (UV–vis absorption, XAS, and EPR), and computational (DFT/TD-DFT calculations) methods to observe and characterize the key intermediates in this reaction for FGE from Streptomyces coelicolor. Our results define the reaction coordinate of FGE, which involves H-atom abstraction from the C β –H bond of the cysteine substrate by a reactive Cu(II)–O 2 •– species to form the now experimentally observed Cu(I)–OOH intermediate bound to a peptidyl-thioaldehyde, which proceeds to oxidize one of the protein-derived cysteine residues to a sulfenate that is end-on O-coordinated to Cu(I). These results provide fundamental insights into how the unusual mononuclear Cu(I) site of FGE activates O 2 for cysteine oxidation and stores oxidizing equivalents during catalysis by employing a Cu(I)–sulfenate intermediate with an end-on O-coordination that is unprecedented in biology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron News from Jefferson Lab

Understanding the spin structure of the nucleon in terms of quarks and gluons has been a challenging endeavor for more than 25 years. The quark's contribution to the spin of the nucleon is well established and amounts to about 30% of 1/2({h_bar}/2{pi}). The study of gluon contributions and orbital angular momenta has been the main experimental (and theoretical) focus in recent years. New results of single-spin asymmetries in semi-inclusive deep-inelastic scattering will be presented. The Sivers- and Collins-Effects were investigated using asymmetries in pion electro-production off transversely polarized helium-3 targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗