Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Heat induces gene amplification in cancer cells

Highlights: Black-Right-Pointing-Pointer This study discovered that heat exposure (hyperthermia) results in gene amplification in cancer cells. Black-Right-Pointing-Pointer Hyperthermia induces DNA double strand breaks. Black-Right-Pointing-Pointer DNA double strand breaks are considered to be required for the initiation of gene amplification. Black-Right-Pointing-Pointer The underlying mechanism of heat-induced gene amplification is generation of DNA double strand breaks. -- Abstract: Background: Hyperthermia plays an important role in cancer therapy. However, as with radiation, it can cause DNA damage and therefore genetic instability. We studied whether hyperthermia can induce gene amplification in cancer cells and explored potential underlying molecular mechanisms. Materials and methods: (1) Hyperthermia: HCT116 colon cancer cells received water-submerged heating treatment at 42 or 44 Degree-Sign C for 30 min; (2) gene amplification assay using N-(phosphoacetyl)-L-aspartate (PALA) selection of cabamyl-P-synthetase, aspartate transcarbarmylase, dihydro-orotase (cad) gene amplified cells; (3) southern blotting for confirmation of increased cad gene copies in PALA-resistant cells; (4) {gamma}H2AX immunostaining to detect {gamma}H2AX foci as an indication for DNA double strand breaks. Results: (1) Heat exposure at 42 or 44 Degree-Sign C for 30 min induces gene amplification. The frequency of cad gene amplification increased by 2.8 and 6.5 folds respectively; (2) heat exposure at both 42 and 44 Degree-Sign C for 30 min induces DNA double strand breaks in HCT116 cells as shown by {gamma}H2AX immunostaining. Conclusion: This study shows that heat exposure can induce gene amplification in cancer cells, likely through the generation of DNA double strand breaks, which are believed to be required for the initiation of gene amplification. This process may be promoted by heat when cellular proteins that are responsible for checkpoints, DNA replication, DNA repair and telomere functions are denatured. To our knowledge, this is the first study to provide direct evidence of hyperthermia induced gene amplification.

60 APPLIED LIFE SCIENCES↗

Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body Radiotherapy

Purpose: To identify the dose-volume parameters that predict the risk of chest wall (CW) pain and/or rib fracture after lung stereotactic body radiotherapy. Methods and Materials: From a combined, larger multi-institution experience, 60 consecutive patients treated with three to five fractions of stereotactic body radiotherapy for primary or metastatic peripheral lung lesions were reviewed. CW pain was assessed using the Common Toxicity Criteria for pain. Peripheral lung lesions were defined as those located within 2.5 cm of the CW. A minimal point dose of 20 Gy to the CW was required. The CW volume receiving >=20, >=30, >=40, >=50, and >=60 Gy was determined and related to the risk of CW toxicity. Results: Of the 60 patients, 17 experienced Grade 3 CW pain and five rib fractures. The median interval to the onset of severe pain and/or fracture was 7.1 months. The risk of CW toxicity was fitted to the median effective concentration dose-response model. The CW volume receiving 30 Gy best predicted the risk of severe CW pain and/or rib fracture (R{sup 2} = 0.9552). A volume threshold of 30 cm{sup 3} was observed before severe pain and/or rib fracture was reported. A 30% risk of developing severe CW toxicity correlated with a CW volume of 35 cm{sup 3} receiving 30 Gy. Conclusion: The development of CW toxicity is clinically relevant, and the CW should be considered an organ at risk in treatment planning. The CW volume receiving 30 Gy in three to five fractions should be limited to <30 cm{sup 3}, if possible, to reduce the risk of toxicity without compromising tumor coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Respiratory Organ Motion During Conformal Radiotherapy in Gastric Cancer

Purpose: To quantify the interfraction and breathing organ motion during adjuvant radiotherapy for gastric cancer and assess organ stability in different breathing states. Methods and Materials: A planning computed tomography (CT) scan and serial study CT scans in free breathing, voluntary inhale and exhale were performed in weeks 1, 3, and 5 of radiotherapy for 22 resected gastric patients. All data sets were fused to register the vertebral bodies. The regions of interest (kidneys, stomach, liver, pancreas, celiac axis, and porta hepatis) or points of interest (POIs; left dome of diaphragm, splenic hilum) were identified. For each region of interest, a POI was automatically placed at the center of mass. The interfraction displacement and breathing amplitude were assessed in the craniocaudal (CC), anteroposterior (AP), and right-left (RL) directions. Results: Comparison of the serial free-breathing CT scans with the planning CT scan showed a median displacement of all POIs of 5.6, 2.2, and 1.8 mm in the CC, AP, and RL directions, respectively. Comparison of the serial inhale scans with the first inhale scan showed a displacement of 4.9, 2.6, and 1.8 mm in the CC, AP, and RL directions, respectively. The comparable values for the exhale scans were 5.1, 2.0, and 1.8 mm. The displacements of the organs were similar in the free breathing, inhale, and exhale states. The median respiratory amplitude in the CC, AP, and RL direction was 14, 4.8, and 1.7 mm, respectively. Conclusion: The median interfraction displacement of the POIs relative to the vertebral bodies was about 6 mm in the CC direction and 2 mm in the other directions. The planning target volume margins need to account for these shifts. Individual assessment of respiratory motion is recommended to identify patients with unusually large respiratory amplitude.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Chest Wall Pain From Lung Stereotactic Body Radiotherapy for Different Fractionation Schemes

Purpose: Recent studies with two fractionation schemes predicted that the volume of chest wall receiving >30 Gy (V30) correlated with chest wall pain after stereotactic body radiation therapy (SBRT) to the lung. This study developed a predictive model of chest wall pain incorporating radiobiologic effects, using clinical data from four distinct SBRT fractionation schemes. Methods and Materials: 102 SBRT patients were treated with four different fractionations: 60 Gy in three fractions, 50 Gy in five fractions, 48 Gy in four fractions, and 50 Gy in 10 fractions. To account for radiobiologic effects, a modified equivalent uniform dose (mEUD) model calculated the dose to the chest wall with volume weighting. For comparison, V30 and maximum point dose were also reported. Using univariable logistic regression, the association of radiation dose and clinical variables with chest wall pain was assessed by uncertainty coefficient (U) and C statistic (C) of receiver operator curve. The significant associations from the univariable model were verified with a multivariable model. Results: 106 lesions in 102 patients with a mean age of 72 were included, with a mean of 25.5 (range, 12-55) months of follow-up. Twenty patients reported chest wall pain at a mean time of 8.1 (95% confidence interval, 6.3-9.8) months after treatment. The mEUD models, V30, and maximum point dose were significant predictors of chest wall pain (p < 0.0005). mEUD improved prediction of chest wall pain compared with V30 (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.11). The mEUD with moderate weighting (a = 5) better predicted chest wall pain than did mEUD without weighting (a = 1) (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.14). Body mass index (BMI) was significantly associated with chest wall pain (p = 0.008). On multivariable analysis, mEUD and BMI remained significant predictors of chest wall pain (p = 0.0003 and 0.03, respectively). Conclusion: mEUD with moderate weighting better predicted chest wall pain than did V30, indicating that a small chest wall volume receiving a high radiation dose is responsible for chest wall pain. Independently of dose to the chest wall, BMI also correlated with chest wall pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Registration of Prostate and Seminal Vesicles for Image Guided Radiation Therapy

Purpose: Fiducial markers are a good surrogate for the prostate but provide little information on the position and orientation of the seminal vesicles (SVs). Therefore, a more advanced localization method is warranted if the SVs are part of the target volume. The purpose of this study was to develop a hybrid registration technique for the localization of the prostate and SVs. Methods and Materials: Twenty prostate patients implanted with 2 or 3 elongated fiducial markers had cone beam computed tomography (CBCT) scans acquired at every fraction. The first step of the hybrid registration was to localize the prostate by CBCT-to-planning-CT alignment of the fiducial markers, allowing both translations and rotations. Using this marker registration as a starting point, the SVs were registered based on gray values, allowing only rotations around the lateral axis. We analyzed the differential rotation between the prostate and SVs and compared the required SV margins for 3 correction strategies. Results: The SV registration had a precision of 2.7° (1 standard deviation) and was successful for 96% of the scans. Mean (M), systematic (Σ), and random (σ) differences between the orientation of the prostate and SV were M = −0.4°, Σ = 7.2°, and σ = 6.4°. Daily marker-based corrections required an SV margin of 11.4 mm (translations only) and 11.6 mm (translations + rotations). Rotation corrections of the SVs reduced the required margin to 8.2 mm. Conclusions: We found substantial differences between the orientation of the prostate and SVs. The hybrid registration technique can accurately detect these rotations during treatment. Rotation correction of the SVs allows for margin reduction for the SVs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain Flare Is a Common Adverse Event in Steroid-Naïve Patients After Spine Stereotactic Body Radiation Therapy: A Prospective Clinical Trial

Purpose: To determine the incidence of pain flare after spine stereotactic body radiation therapy (SBRT) in steroid-naïve patients and identify predictive factors. Methods and Materials: Forty-one patients were treated with spine SBRT between February 2010 and April 2012. All patients had their pain assessed at baseline, during, and for 10 days after SBRT using the Brief Pain Inventory. All pain medications were recorded daily and narcotics converted to an oral morphine equivalent dose. Pain flare was defined as a 2-point increase in worst pain score as compared with baseline with no decrease in analgesic intake, a 25% increase in analgesic intake as compared with baseline with no decrease in worst pain score, or if corticosteroids were initiated at any point during or after SBRT because of pain. Results: The median age and Karnofsky performance status were 57.5 years (range, 27-80 years) and 80 (range, 50-100), respectively. Eighteen patients were treated with 20-24 Gy in a single fraction, whereas 23 patients were treated with 24-35 Gy in 2-5 fractions. Pain flare was observed in 68.3% of patients (28 of 41), most commonly on day 1 after SBRT (29%, 8 of 28). Multivariate analysis identified a higher Karnofsky performance status (P=.02) and cervical (P=.049) or lumbar (P=.02) locations as significant predictors of pain flare. In those rescued with dexamethasone, a significant decrease in pain scores over time was subsequently observed (P<.0001). Conclusions: Pain flare is a common adverse event after spine SBRT and occurs most commonly the day after treatment completion. Patients should be appropriately consented for this adverse event.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interim PET After Two ABVD Cycles in Early-Stage Hodgkin Lymphoma: Outcomes Following the Continuation of Chemotherapy Plus Radiotherapy

Purpose: This multicenter retrospective study was designed to evaluate the prognostic role of interim fluorodeoxyglucose-labeled positron emission tomography (i-FDG-PET) in a cohort of patients affected with early-stage Hodgkin lymphoma (HL) treated initially with adriamycin, bleomycin, vinblastine, dacarbazine (ABVD) chemotherapy followed by radiation therapy, and to assess the role of chemotherapy continuation plus radiation therapy for i-FDG-PET-positive patients. Methods and Materials: Data from 257 patients were retrieved from 4 hematology and radiation oncology departments. Inclusion criteria were stage I to IIAB HL, “intention-to-treat” AVBD plus radiation therapy, and FDG-PET at diagnosis and after the first 2 ABVD cycles. All i-FDG-PET scans underwent blinded local review by using the Deauville 5-point scoring system; patients were stratified as negative or positive using 2 Deauville score cutoff values, ≥3 or ≥4. Results: Median follow-up time was 56 months (range: 9-163 months); 5-year overall survival (OS) and disease-specific survival (DSS) for the whole cohort were 97.5% and 98.3%, respectively. Five-year progression-free survival (PFS) was 95.6%. After i-FDG-PET revision, 43 of 257 patients (16.7%) had a positive i-FDG-PET (Deauville scores: 3-5). Five-year PFS rates for i-FDG-PET-negative and i-FDG-PET-positive patients were 98.1% and 83.7%, respectively, if using a Deauville score cutoff of 3, and 97.7% and 78.6%, respectively, if using a cutoff of 4 (P=.0001). Five-year OS for i-FDG-PET-negative and i-FDG-PET-positive patients was 98.5% and 93.0%, respectively, if using a cutoff of 3, and 98.6% and 89.3%, respectively, if using a cutoff of 4 (P=.029 and P=.002). At univariate regression analysis, i-FDG-PET positivity was associated with worse OS and PFS. At multivariate analysis, performed only for PFS, i-FDG-PET positivity confirmed its negative impact (P=.002). Conclusions: i-FDG-PET is prognostic for PFS and OS in early-stage HL patients treated with combined modality therapy; the continuation of chemotherapy followed by radiation therapy is able to obtain durable, complete remission in most i-FDG-PET-positive patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncovering multiscale structure-property correlations via active learning in scanning tunneling microscopy

Atomic arrangements and local sub-structures fundamentally influence emergent material functionalities. These structures are conventionally probed using spatially resolved studies and the property correlations are deciphered by a researcher based on sequential explorations, thereby limiting the efficiency and scope. Here we demonstrate a multi-scale Bayesian deep-learning based framework that automatically correlates material structure with its electronic properties using scanning tunneling microscopy (STM) measurements in real-time. Its predictions are used to autonomously direct exploration toward regions of the sample that optimize a given material property. This method is deployed on a low-temperature ultra-high vacuum STM to understand the structure-property relationship in a europium-based semimetal, EuZn 2 As 2 , a promising candidate relevant to magnetism-driven topological phenomena. The framework employs a sparse-sampling approach to efficiently construct the scalar-property space using minimal measurements, about 1–10% of the data required in standard hyperspectral methods. Moreover, we formulate the problem hierarchically across length scales, implementing autonomous workflow to locate mesoscopic and atomic structures that correspond to a target material property. This framework offers the choice to design scalar-property from the spectroscopic data to steer sample exploration. Our findings reveal correlations of the electronic properties unique to surface terminations, local defect density, and point defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials

SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response to 'Comment on 'Elastic incoherent neutron scattering operating by varying instrumental energy resolution: Principle, simulations, and experiments of the resolution elastic neutron scattering (RENS)'' [Rev. Sci. Instrum. 83, 107101 (2012)]

Recently [S. Magazu et al., Rev. Sci. Instrum. 82, 105115 (2011)] we have proposed a new method for characterizing, by neutron scattering, the dynamical properties of complex material systems, such as, the ones of interest in the biophysical field. This approach called Resolution Elastic Neutron Scattering, in short RENS, is based on the detection of the elastically scattered neutron intensity as a function of the instrumental energy resolution. By experimental, theoretical, and numerical findings, we have pointed out that an inflection point occurs in the elastic intensity when the system relaxation time approaches the instrumental energy resolution time. This approach, differently from quasi-elastic neutron scattering (QENS), gives the chance to evaluate the system relaxation times without using pre-defined models that can be wrong and/or misleading. Here, we reply to a Comment on the above-mentioned main paper in which Wuttke proposes a different approach to evaluate the above-mentioned inflection point; on this regard, it should be noticed that the existence of the inflection point, which is the main topic of our work, is not questioned and that the approach proposed by Wuttke in the Comment, although valid for a class of dynamical processes, is not applicable when different and distinct processes occur simultaneously at different time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-heavy electron material as metallic refrigerant for adiabatic demagnetization cooling

Low-temperature refrigeration is of crucial importance in fundamental research of condensed matter physics, because the investigations of fascinating quantum phenomena, such as superconductivity, superfluidity, and quantum criticality, often require refrigeration down to very low temperatures. Currently, cryogenic refrigerators with 3 He gas are widely used for cooling below 1 Kelvin. However, usage of the gas has been increasingly difficult because of the current world-wide shortage. Therefore, it is important to consider alternative methods of refrigeration. We show that a new type of refrigerant, the super-heavy electron metal YbCo 2 Zn 20 , can be used for adiabatic demagnetization refrigeration, which does not require 3 He gas. This method has a number of advantages, including much better metallic thermal conductivity compared to the conventional insulating refrigerants. We also demonstrate that the cooling performance is optimized in Yb 1$-$x Sc x Co 2 Zn 20 by partial Sc substitution, with x ~ 0.19. The substitution induces chemical pressure that drives the materials to a zero-field quantum critical point. This leads to an additional enhancement of the magnetocaloric effect in low fields and low temperatures, enabling final temperatures well below 100 mK. This performance has, up to now, been restricted to insulators. For nearly a century, the same principle of using local magnetic moments has been applied for adiabatic demagnetization cooling. Lastly, this study opens new possibilities of using itinerant magnetic moments for cryogen-free refrigeration.

36 MATERIALS SCIENCE↗

Balloon-borne submillimeter polarimetry of the Vela C molecular cloud: systematic dependence of polarization fraction on column density and local polarization-angle dispersion

We present results for Vela C obtained during the 2012 flight of the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry. We mapped polarized intensity across almost the entire extent of this giant molecular cloud, in bands centered at 250, 350, and 500 μm. In this initial paper, we show our 500 μm data smoothed to a resolution of 2.′5 (approximately 0.5 pc). We show that the mean level of the fractional polarization p and most of its spatial variations can be accounted for using an empirical three-parameter power-law fit, p ∝ N{sup −0.45} S{sup −0.60}, where N is the hydrogen column density and S is the polarization-angle dispersion on 0.5 pc scales. The decrease of p with increasing S is expected because changes in the magnetic field direction within the cloud volume sampled by each measurement will lead to cancellation of polarization signals. The decrease of p with increasing N might be caused by the same effect, if magnetic field disorder increases for high column density sightlines. Alternatively, the intrinsic polarization efficiency of the dust grain population might be lower for material along higher density sightlines. We find no significant correlation between N and S. Comparison of observed submillimeter polarization maps with synthetic polarization maps derived from numerical simulations provides a promising method for testing star formation theories. Realistic simulations should allow for the possibility of variable intrinsic polarization efficiency. The measured levels of correlation among p, N, and S provide points of comparison between observations and simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗

Self-assembly of designed precursors: A route to crystallographically aligned new materials with controlled nanoarchitecture

Modulated elemental reactants is a method by which new and complex intergrowth compounds can be synthesized by the self-assembly of designed precursors prepared by physical vapor deposition. Careful calibration of the composition and thickness of the precursors ensures the formation of the desired product by precise control of local composition and diffusion lengths. Superstructures of increasing complexity can be realized using binary and ternary systems as starting points. The synthesis of systems based on three different binary compounds, either alloyed together or separated into distinct layers, expands the number of possible superstructures that can be formed using this technique, but provides analytical challenges. The synthesis of [(SnSe){sub 1.15}]{sub 1}([Ta{sub x}V{sub 1−x}]Se{sub 2}){sub 1}[(SnSe){sub 1.15}]{sub 1}([V{sub y}Ta{sub 1−y}]Se{sub 2}){sub 1} compound is used to illustrate the preparation of precursors and the challenges in both measuring and limiting the interdiffusion of layers during self-assembly. Systematic changes in the electrical properties of (SnSe){sub 1+δ}(Ta{sub x}V{sub 1−x})Se{sub 2} alloys are observed as x is varied. The electrical resistivity of [(SnSe){sub 1.15}]{sub 1}([Ta{sub x}V{sub 1−x}]Se{sub 2}){sub 1}[(SnSe){sub 1.15}]{sub 1}([V{sub y}Ta{sub 1−y}]Se{sub 2}){sub 1} can be modeled as the two constituent layers in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature thermochemical energy storage materials

Disclosed are thermal energy storage systems and methods that utilize metal carbonate eutectics that can undergo high temperature reversible reactions to form mixtures of metal oxides. The metal oxides undergo an exothermic reaction with carbon dioxide to form the molten metal carbonate eutectics, and the molten metal carbonate eutectics undergo an endothermic decarbonization reaction to form the metal oxides and carbon dioxide. By carrying out the reversible reactions at a temperature above the melting point of the carbonate eutectic, the systems provide high thermal conductivity and reversible stability for thermal energy storage.

25 ENERGY STORAGE↗

Inferring Strength of Tantalum from Hydrodynamic Instability Recovery Experiments

Hydrodynamic instability experiments allow access to material properties at extreme conditions, where strain rates exceed 105 s -1 and pressures reach 100 GPa. Current hydrodynamic instability experimental methods require in-flight radiography to image the instability growth at high pressure and high strain rate, limiting the facilities where these experiments can be performed. An alternate approach, recovering the sample after loading, allows measurement of the instability growth with profilometry. Tantalum samples were manufactured with different 2D and 3D initial perturbation patterns and dynamically compressed by a blast wave generated by laser ablation. The samples were recovered from peak pressures between 30 and 120 GPa and strain rates on the order of 107 s -1 , providing a record of the growth of the perturbations due to hydrodynamic instability. These records are useful validation points for hydrocode simulations using models of material strength at high strain rate. Recovered tantalum samples were analyzed, providing an estimate of the strength of the material at high pressure and strain rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predictive Engineering Tools for Injection-Molded Long-Carbon-Fiber Thermoplastic Composites - FY 2016 First Quarterly Report

During the first quarter of FY 2016, the following technical progress has been made toward project milestones: 1) Virginia Tech completed fiber orientation (FO) measurements for the samples taken at Locations A, B, C and D (Figure 1) from the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed and non-ribbed complex parts using Virginia Tech’s established procedure. Virginia Tech delivered to PNNL all the measured fiber orientation data for validating ASMI fiber orientation predictions. 2)Virginia Tech performed fiber length distribution (FLD) measurements for the samples taken at Locations A, B, C and D from these complex parts using Virginia Tech’s established procedure. Virginia also re-assessed previous data and measured fiber length distributions in the corresponding nozzle purging materials and delivered to PNNL all the measured length data for validating ASMI fiber length predictions. 3)Based on measured fiber orientation data, Autodesk identified the parameters of the anisotropic rotary diffusion reduced strain closure (ARD-RSC) model [1] and provided PNNL with the values of these parameters that were used in ASMI analyses of the complex parts. 4) Magna provided Virginia Tech with additional samples cut out from the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed parts (Figure 1) for fiber length and orientation measurements. 5) In discussion with Autodesk, PNNL performed 3D ASMI analyses of the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed and non-ribbed complex parts to predict fiber orientations and length distributions in these parts. The issues observed through the analyses regarding fiber orientation distributions profiles and abnormal length distributions were reported to Autodesk. Autodesk is working to resolve these issues. 6) PNNL completed 3D ASMI analyses of the complex parts and compared predicted fiber orientation results at Locations A, B, and C on the non-ribbed parts, and at Locations A, B, C and D on the ribbed parts with the corresponding measured data. PNNL also evaluated the within-15%-agreement criterion using the principal tensile and flexural moduli computed based on predicted vs. measured fiber orientation results. 7) PNNL developed and discussed with Toyota, Magna and PlastiComp a method to perform weight and cost reduction for making the 30wt% LCF/PA66 ribbed part through comparative three-point bending simulations of this part and of similar parts in steel.

36 MATERIALS SCIENCE↗

Unzipping hBN with ultrashort mid-infrared pulses

Manipulating the nanostructure of materials is critical for numerous applications in electronics, magnetics, and photonics. However, conventional methods such as lithography and laser writing require cleanroom facilities or leave residue. We describe an approach to creating atomically sharp line defects in hexagonal boron nitride (hBN) at room temperature by direct optical phonon excitation with a mid-infrared pulsed laser from free space. We term this phenomenon “unzipping” to describe the rapid formation and growth of a crack tens of nanometers wide from a point within the laser-driven region. Formation of these features is attributed to the large atomic displacement and high local bond strain produced by strongly driving the crystal at a natural resonance. This process occurs only via coherent phonon excitation and is highly sensitive to the relative orientation of the crystal axes and the laser polarization. Its cleanliness, directionality, and sharpness enable applications such as polariton cavities, phonon-wave coupling, and in situ flake cleaving.

36 MATERIALS SCIENCE↗