Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses

High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90 Degree-Sign collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF{sub 2} scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF{sub 2} scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

36 MATERIALS SCIENCE↗

Validation of MCNP5 for use in Calculating Temperature Coefficients of Reactivity for the SHINE System

Neutron transport calculations for the SHINE system are being done with MCNP, a general-purpose Monte Carlo NParticle code developed at Los Alamos National Laboratory (LANL). Current calculations are being done with MCNP5, version 1.6. This paper describes the methods used to calculate a tolerance band for temperature coefficients of reactivity (α{sub T}) calculated with MCNP5, v1.6 for the SHINE system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Results for CCQE Scattering with the MINOS Near Detector

The MINOS Near Detector has recorded over 20 million neutrino interactions since the experiment began taking NuMI beam data in March 2005. At neutrino energies around the peak of the NuMI flux ({approx}3 GeV) one of the dominant interaction modes is charged-current quasi-elastic (CCQE) scattering and the high statistics Near Detector dataset allows for measurements of the characteristics of this process. A CCQE-enriched event sample is defined and the data collected during the first year of NuMI beam operation are compared to the prediction from the MINOS Monte Carlo simulation (MC). To better describe the data, fits are performed to extract values for a number of parameters in the MC including a low Q{sup 2} suppression parameter for CCQE events and the axial-vector mass, M{sub A}, for CCQE scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial and spectral effects in subcritical system pulsed experiments

Accurate neutronic models are needed for the interpretation of pulsed experiments in subcritical systems. In this work, the extent of spatial and spectral effects in the pulse propagation phenomena is investigated and the analysis is applied to the GUINEVERE experiment. The multigroup cross section data is generated by the Monte Carlo SERPENT code and the neutronic evolution following the source pulse is simulated by a kinetic diffusion code. The results presented show that important spatial and spectral aspects need to be properly accounted for and that a detailed energy approach may be needed to adequately capture the physical features of the system to the pulse injection. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Observation of fast-ion Doppler-shifted cyclotron resonance with shear Alfven waves

The Doppler-shifted cyclotron resonance ({omega}-k{sub z}v{sub z}={omega}{sub f}) between fast ions and shear Alfven waves is experimentally investigated ({omega}, wave frequency; k{sub z}, axial wavenumber; v{sub z}, fast-ion axial speed; {omega}{sub f}, fast-ion cyclotron frequency). A test particle beam of fast ions is launched by a Li{sup +} source in the helium plasma of the LArge Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)], with shear Alfven waves (SAW) (amplitude {delta} B/B up to 1%) launched by a loop antenna. A collimated fast-ion energy analyzer measures the nonclassical spreading of the beam, which is proportional to the resonance with the wave. A resonance spectrum is observed by launching SAWs at 0.3-0.8{omega}{sub ci}. Both the magnitude and frequency dependence of the beam-spreading are in agreement with the theoretical prediction using a Monte Carlo Lorentz code that launches fast ions with an initial spread in real/velocity space and random phases relative to the wave. Measured wave magnetic field data are used in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparisons of neutrino event generators from an oscillation-experiment perspective

Monte Carlo generators are crucial to the analysis of high energy physics data, ideally giving a baseline comparison between the state-of-art theoretical models and experimental data. Presented here is a comparison between three of final state distributions from the GENIE, Neut, NUANCE, and NuWro neutrino Monte Carlo event generators. The final state distributions chosen for comparison are: the electromagnetic energy fraction in neutral current interactions, the energy of the leading π{sup 0} vs. the scattering angle for neutral current interactions, and the muon energy vs. scattering angle of ν{sub µ} charged current interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and experimental validation of a calculation scheme for nuclear heating evaluation in the core of the OSIRIS material testing reactor

The control of the temperature in material samples irradiated in a material testing reactor requires the knowledge of the nuclear heating caused by the energy deposition by neutrons and photons interacting in the irradiation device structures. Thus, a neutron-photonic three-dimensional calculation scheme has been developed to evaluate the nuclear heating in experimental devices irradiated in the core of the OSIRIS MTR reactor (CEA/Saclay Center). The aim is to obtain a predictive tool for the nuclear heating estimation in irradiation devices. This calculation scheme is mainly based on the TRIPOLI-4 three-dimensional continuous-energy Monte Carlo transport code, developed by CEA (Saclay Center). An experimental validation has been carried out on the basis of nuclear heating measurements performed in the OSIRIS core. After an overview of the experimental devices irradiated in the OSIRIS reactor, we present the calculation scheme and the first results of the experimental validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations

Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark Study of Infinite Lattice of Pebble Fuel within FLiBe Coolant for TMSR-SF1 Design

Solid Fueled Thorium Molten Salt Reactor (TMSR-SF1) is Chinese Fluoride-salt-cooled High Temperature Reactor (FHR) designed by the TMSR group. The construction of this test reactor is expected in the near years. Using TRISO particle based pebble fuel leads to various challenges in neutronics modeling, such as double heterogeneity effect, preserving exact number of particles, their random distributions in pebble, and etc. For the purpose of verifying the calculations, benchmark study of infinite lattice of pebble fuel within FLiBe coolant for the TMSR-SF1 design has been performed. Back-to-back comparisons have been made between TMSR and MIT researchers using different Monte-Carlo based codes. Very good agreements have been found and the results quantitatively evaluate the neutronic effect of various modeling approaches. In addition, sensitivity study has been carried out for the reference pebble-bed fuel lattice. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity Calculations for Systems with Polyethylene Reflector Materials Using CLUTCH

The SCALE 6.2.4 code package contains four sequences for calculating $k_{eff}$ sensitivity coefficients. Two of these sequences use deterministic transport solvers: a one-dimensional (1D) capability based on XSDRN, and a two-dimensional (2D) capability based on NEWT. These sequences are restricted to the multigroup (MG) treatment of neutron energy. The three-dimensional (3D) sequences use the KENO V.a or KENO-VI Monte Carlo transport codes and can be used to calculate sensitivity coefficients with either MG or continuous-energy (CE) transport. The 3D sensitivities are ultimately reported in an MG structure, regardless of the method used in the transport calculations. If desired, the sensitivity coefficients can be reported with very fine energy resolution from a CE calculation, but they are calculated only in the MG library structure in the MG mode. CE TSUNAMI methods are available in SCALE starting in SCALE version 6.2. Sensitivity coefficients were generated using the 3D sequences as part of the generation of the SCALE 6.2.2 Validation Report; difficulties encountered when using the CLUTCH method for thick, fissionable-material reflectors were discussed and investigated as documented in a previous paper. This paper discusses the difficulties encountered in generating accurate sensitivity coefficients using the CLUTCH technique for polyethylene reflectors for two fast spectrum benchmarks. Direct perturbation (DP) calculations were performed to confirm the accuracy of the total sensitivity coefficient for important isotopes with large sensitivities in the system. Discrepancies were detected for CLUTCH-calculated sensitivity coefficients in the reflector of a critical experiment with a radial polyethylene reflector. A simple polyethylene-reflected plutonium sphere was then used to further investigate the discrepancy. Calculations performed using the iterated fission probability (IFP) method generated accurate sensitivity coefficients in both cases. The results of this study emphasize the need to confirm CLUTCH sensitivity results with DP calculations. IFP calculations are generally less efficient but more reliable than CLUTCH calculations. Improvements to the CLUTCH methodology that retain the greater efficiency but address identified difficulties are therefore potentially useful to analysts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility study of archaeological structures scanning by muon tomography

One of the main concerns in archaeology is to find of a method to study precisely archaeological structures in the least invasive way possible to avoid damage. The requirement of preserving the structures integrity prevents, in the case of pyramids or tumuli, the study of any internal structure (halls or tombs) which are not reachable by existing corridors. One non-invasive method is the muon tomography. By placing a detector which allows to register the muon direction after the structure, it is possible to have an idea of its composition based on the attenuation of the muon flux, which depends on the material length and density that muons have crossed. This technique, alone or together with other exploration techniques as seismic tomography or electrical resistivity tomography, can provide useful information about the internal structure of the archaeological form that can not be obtained by conventional archaeological methods. In this work, the time measurement necessary to obtain a significant result about the composition of an archaeological structure is estimated. To do that, a Monte Carlo simulation framework based on the MUSIC software, properly tuned for this study, has been developed. The particular case of the Kastas Amfipoli Macedonian tumulus has been considered to perform the simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Criticality Convergence via a Modified Monte Carlo Power Iteration Method

Monte Carlo transport codes typically estimate the fundamental mode of a nuclear system via a power iteration method. If the eigenvalues of the system are denoted $k$ 1 , $k$ 2 , $k$ 3 ..." with $k$ 1 > $k$ 2 ≥ $k$ 3 ≥ $k$ 4 ··· > 0, and corresponding eigenfunctions Ψ $m$ , it is well known that the Ψ $m$ mode disappears after $n$ iterations as ($k$ $m$ /$k$ 1 ) $n$ . When the dominance ratio $k$ 2 /$k$ 1 is near unity, the convergence to Ψ 1 can be very slow, even if the convergence to $k$ 1 is fast. The convergence to Ψ 1 sometimes can be dramatically improved by estimating Ψ 1 and Ψ 2 . A Monte Carlo implementation of the modified power iteration method requires the neutrons representing Ψ 2 to have both negative and positive weights because Ψ 2 cannot be of one sign. Thus, Ψ 2 is a sum of negatively and positively weighted neutrons. Instead of summing using point detector methods, a new simple binning procedure accelerates convergence to Ψ 1 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Orbits for 18 Visual Binaries and Two Double-line Spectroscopic Binaries Observed with HRCAM on the CTIO SOAR 4 m Telescope, Using a New Bayesian Orbit Code Based on Markov Chain Monte Carlo

We present orbital elements and mass sums for 18 visual binary stars of spectral types B to K (five of which are new orbits) with periods ranging from 20 to more than 500 yr. For two double-line spectroscopic binaries with no previous orbits, the individual component masses, using combined astrometric and radial velocity data, have a formal uncertainty of ∼0.1 M{sub ⊙}. Adopting published photometry and trigonometric parallaxes, plus our own measurements, we place these objects on an H-R diagram and discuss their evolutionary status. These objects are part of a survey to characterize the binary population of stars in the Southern Hemisphere using the SOAR 4 m telescope+HRCAM at CTIO. Orbital elements are computed using a newly developed Markov chain Monte Carlo (MCMC) algorithm that delivers maximum-likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate the uncertainty of our derived parameters in a robust way. For spectroscopic binaries, using our approach, it is possible to derive a self-consistent parallax for the system from the combined astrometric and radial velocity data (“orbital parallax”), which compares well with the trigonometric parallaxes. We also present a mathematical formalism that allows a dimensionality reduction of the feature space from seven to three search parameters (or from 10 to seven dimensions—including parallax—in the case of spectroscopic binaries with astrometric data), which makes it possible to explore a smaller number of parameters in each case, improving the computational efficiency of our MCMC code.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation study of a 'fission electron-collection' neutron detector

In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical estimation on free electrons generated by shielded radioactive materials under various gaseous environments

We report simulation results on generation of free electrons due to the presence of radioactive materials under controlled pressure and gases using a general Monte Carlo transport code (MCNPX). A radioactive material decays to lower atomic number, simultaneously producing high energy gamma rays that can generate free electrons via various scattering mechanisms. This paper shows detailed simulation works for answering how many free electrons can be generated under the existence of shielded radioactive materials as a function of pressure and types of gases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Functional Expansion Tallies Using MCNP6 PTRAC Files [Slides]

Accuracy is vital for many radiation transport applications. Monte Carlo (MC) codes are the most accurate, but they are expensive for fine meshes. Functional Expansion Tallies (FETs) yield smoother, lower-variance results with far fewer degrees of freedom.

97 MATHEMATICS AND COMPUTING↗

Evaluation of internal contamination levels after a radiological dispersal device incident using portal monitors

Following a radioactive dispersal device (RDD) incident, it may be necessary to evaluate the internal contamination levels of a large number of potentially affected individuals to determine if immediate medical follow-up is necessary. Since the current laboratory capacity to screen for internal contamination is limited, rapid field screening methods can be useful in prioritizing individuals. This study evaluated the suitability of a radiation portal monitor for such screening. A model of the portal monitor was created for use with models of six anthropomorphic phantoms in Monte Carlo N-Particle Transport Code Version 5 (MCNP) X-5 Monte Carlo Team (MCNP A General Monte Carlo N-Particle Transport Code Version 5. LA-CP-03-0245. Vol. 2. Los Alamos National Laboratory, 2004.). The count rates of the portal monitor were simulated for inhalation and ingestion of likely radionuclides from an RDD for each of the phantoms. The time-dependant organ concentrations of the radionuclides were determined using Dose and Risk Calculation Software Eckerman, Leggett, Cristy, Nelson, Ryman, Sjoreen and Ward (Dose and Risk Calculation Software Ver. 8.4. ORNL/TM-2001/190. Oak Ridge National Laboratory, 2006.). Portal monitor count rates corresponding to a committed effective dose E(50) of 10 mSv are reported.

61 RADIATION PROTECTION AND DOSIMETRY↗