Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SU-F-T-253: Volumetric Comparison Between 4D CT Amplitude and Phase Binning Mode

Purpose: Motion artifact in 4DCT images can affect radiation treatment quality. To identify the most robust and accurate binning method, we compare the volume difference between targets delineated on amplitude and phase binned 4DCT scans. Methods: Varian RPM system and CT scanner were used to acquire 4DCTs of a Quasar phantom with embedded cubic and spherical objects having superior-inferior motion. Eight patients’ respiration waveforms were used to drive the phantom. The 4DCT scan was reconstructed into 10 phase and 10 amplitude bins (2 mm slices). A scan of the static phantom was also acquired. For each waveform, sphere and cube volumes were generated automatically on each phase using HU thresholding. Phase (amplitude) ITVs were the union of object volumes over all phase (amplitude) binned images. The sphere and cube volumes measured in the static phantom scan were V{sub sphere}=4.19cc and V{sub cube}=27.0cc. Volume difference (VD) and dice similarity coefficient (DSC) of the ITVs, and mean volume error (MVE) defined as the average target volume percentage difference between each phase image and the static image, were used to evaluate the performance of amplitude and phase binning. Results: Averaged over the eight breathing traces, the VD and DSC of the internal target volume (ITV) between amplitude and phase binning were 3.4%±3.2% (mean ± std) and 95.9%±2.1% for sphere; 2.1%±3.3% and 98.0% ±1.5% for cube, respectively.For all waveforms, the average sphere MVE of amplitude and phase binning was 6.5% ± 5.0% and 8.2%±6.3%, respectively; and the average cube MVE of amplitude and phase binning was 5.7%±3.5%and 12.9%±8.9%, respectively. Conclusion: ITV volume and spatial overlap as assessed by VD and DSC are similar between amplitude and phase binning. Compared to phase binning, amplitude binning results in lower MVE suggesting it is less susceptible to motion artifact.

60 APPLIED LIFE SCIENCES↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

EDS-PhaSe: Phase Segmentation and Analysis from EDS Elemental Map Images Using Markers of Elemental Segregation

Scanning electron microscopy (SEM), combined with energy-dispersive spectroscopy (EDS), is an extensively used technique for in-depth microstructural analysis. Here, we present the EDS-Phase Segmentation (EDS-PhaSe) tool that enables phase segmentation and phase analysis using the EDS elemental map images. Importantly, it converts the EDS map images into estimated composition maps for calculating markers of selective elemental redistribution in the scanned area and creates a phase-segmented micrograph while providing approximate fraction and composition of each identified phase. EDS-PhaSe offers two unique advantages. Firstly, it enables the direct processing of EDS elemental map images without requiring any raw or proprietary data/software, thereby allowing the analysis of EDS results available in the published literature as images. Secondly, it enables segmentation and analysis of phases even when the phase contrast is missing in backscattered micrographs, assisting in correlating the XRD and SEM-EDS data as shown in this work for a AlCoCrFeNi high-entropy alloy.

36 MATERIALS SCIENCE↗

Higher-order phase shift reconstruction approach

Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Shift Interferometer and Growth Set Up to Step Pattern Formation During Growth From Solutions. Influence of the Oscillatory solution Flow on Stability

We have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a flow of solution of controlled direction and speed. The reference arm of the interferometer contains a liquid crystal element that allows controlled shifts of the phase of the interferograms. We employ an image-processing algorithm, which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 60 frames per second. The device allows data collection on surface morphology and kinetics during the face layers growth over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The estimated depth resolution of the phase shifting interferometry is approximately 50 Angstroms. The data will be analyzed in order to reveal and monitor step bunching during the growth process. The crystal chosen as a model for study in this work is KH2PO4 (KDP). This optically non-linear material is widely used in frequency doubling applications. There have been a number of studies of the kinetics of KDP crystallization that can serve as a benchmark for our investigations. However, so far, systematic quantitative characteristics of step interaction and bunching are missing. We intend to present our first quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. Behavior of a vicinal face growing from solution flowing normal to the steps and periodically changing its direction in time was considered theoretically. It was found that this oscillating flow reduces both stabilization and destabilization effects resulted from the unidirectional solution flow directed up the step stream and down the step stream. This reduction of stabilization and destabilization comes from effective mixing which entangles the phase shifts between the spatially periodic interface perturbation and the concentration wave induced by this perturbation. Numerical results and simplified mixing criterion will be discussed.

Chernov, Alex A.↗

Three-Dimensional Imaging through Shock-Waves at Ultra-High Speed

Imaging diagnostics that utilize coherent light, such as digital in-line holography, are important for object sizing and tracking applications. However, in explosive, supersonic, or hypersonic environments, gas-phase shocks impart imaging distortions that obscure internal objects. To circumvent this problem, some research groups have conducted experiments in vacuum, which inherently alters the physical behavior. Other groups have utilized single-shot flash x-ray or high-speed synchrotron x-ray sources to image through shock-waves. In this work, we combine digital in-line holography with a phase conjugate mirror to reduce the phase distortions caused by shock-waves. The technique operates by first passing coherent light through the shock-wave phase-distortion and then a phase-conjugate mirror. The phase-conjugate mirror is generated by a four-wave mixing process to produce a return beam that has the exact opposite phase-delay as the forward beam. Therefore, by passing the return beam back through the phase-distortion, the phase delays picked up during the initial pass are canceled, thereby producing improved coherent imaging. In this work, we implement phase conjugate digital in-line holography (PCDIH) for the first time with a nanosecond pulse-burst laser and ultra-high-speed cameras. This technique enables accurate measurement of the three-dimensional position and velocity of objects through shock-wave distortions at video rates up to 5 MHz. This technology is applied to improve three-dimensional imaging in a variety of environments from imaging supersonic shock-waves through turbulence, sizing objects through laser-spark plasma-generated shock-waves, and tracking explosively generated hypersonic fragments. Theoretical foundations and additional capabilities of this technique are also discussed.

47 OTHER INSTRUMENTATION↗

Interferometric Characterization of Keck Segment Edge Errors

The Keck telescope segments were manufactured by stressed mirror polishing of large circular pieces of Zerodur that were then cut into hexagons and finished by Ion Beam Figuring (IBF). It has long been believed that this process results in segments with little or no edge effects. As a result, this same general approach is planned for segment manufacturing for the Thirty Meter Telescope (TMT) and the European Extremely Large Telescope (E-ELT). However, recent measurements at the Keck telescope suggest that at least some of the Keck segments have significant aberrations within 60 mm of the edge. These aberrations impact the telescope phasing and the overall telescope image quality. We present interferometric measurements of multiple Keck segments, characterizing the surface errors near the edges over spatial periods from 5 cm down to 1 mm. We show that the largest phasing and image quality effects are due to plateaus of unremoved material, left behind after IBF as a result of obscuration by the IBF supports. Apart from these plateaus, the edge quality is relatively good, though not as good as in the segment interiors. Some residual phasing and image quality effects remain, and these are not currently understood.

Martinek, Stephen J.↗

Influence of crystallographic orientation and applied magnetic field on domain structure in duplex stainless steel studied using magnetic force microscopy

Highlights: • Ferrite phase in a duplex stainless steel consists of stripe type domains. • Domain contrast decreases with deviation of plane normal from <100>. • Domain width increases with deviation of plane normal from <100>. • Domain alignment with applied field observed along <100> directions. • Grain boundary stray field is a function of misorientation between grains. - Abstract: The paper investigates the local micro-magnetization behavior in duplex stainless steel (DSS) using magnetic force microscopy (MFM). DSS has equal amount of austenite phase in ferrite matrix. The MFM imaging clearly differentiates ferrite phase (ferromagnetic) from the austenite phase (paramagnetic) due to the maze type magnetic domains present in the ferrite phase. The magneto crystalline anisotropic effect on the domain structure is discussed with the support of electron backscatter diffraction (EBSD) measurements. The MFM phase contrast and domain width are correlated with the orientation of surface normal with respect to the easy axis of magnetization (<100>). The influence of external magnetic field (±127 kA/m) application on the domain structure is studied as a function of the grain orientation and the leakage field at the grain boundaries is analyzed based on the mis-orientation between the grains.

36 MATERIALS SCIENCE↗

Differentiating and Quantifying Gas-Phase Conformational Isomers Using Coulomb Explosion Imaging

Conformational isomerism plays a crucial role in defining the physical and chemical properties and biological activity of molecules ranging from simple organic compounds to complex biopolymers. However, it is often a significant challenge to differentiate and separate these isomers experimentally as they can easily interconvert due to their low rotational energy barrier. Here, we use the momentum correlation of fragment ions produced after inner-shell photoionization to distinguish conformational isomers of 1,2-dibromoethane (C 2 H 4 Br 2 ). We demonstrate that the three-body breakup channel, C 2 H 4 + + Br + + Br + , contains signatures of both sequential and concerted breakup, which are decoupled to distinguish the geometries of two conformational isomers and to quantify their relative abundance. The sensitivity of our method to quantify these yields is established by measuring the relative abundance change with sample temperature, which agrees well with calculations. Finally, our study paves the way for using Coulomb explosion imaging to track subtle molecular structural changes.

Photoionization↗

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

TH-CD-207A-06: Optimizing Four-Dimensional Digital Tomosynthesis Acquisition Based On Respiratory Guidance

Purpose: Patient breathing-related sorting method of projections in 4D digital tomosythesis (DTS) can be suffered from severe artifacts due to non-uniform angle distribution of projections and noncoplanar reconstructed images for each phase. In this study, we propose a method for optimally acquiring projection images in 4D DTS. Methods: In this method every pair of projections at x-ray tube’s gantry angles symmetrical with respect to the center of the range of gantry rotation is obtained at the same respiration amplitude. This process is challenging but becomes feasible with visual-biofeedback using a patient specific respiration guide wave which is in sinusoidal shape (i.e., smooth and symmetrical enough). Depending on scan parameters such as the number of acquisition points per cycle, total scan angle and projections per acquisition amplitude, acquisition sequence is pre-determined. A simulation study for feasibility test was performed. To mimic actual situation closely, a group of volunteers were recruited and breathing data were acquired both with/without biofeedback. Then, x-ray projections for a humanoid phantom were virtually performed following (1) the breathing data from volunteers without guide, (2) the breathing data with guide and (3) the planned breathing data (i.e., ideal situation). Images from all of 3 scenarios were compared. Results: Scenario #2 showed significant artifact reduction compared to #1 while did minimal increase from the ideal situation (i.e., scenario #3). We verified the performance of the method with regard to the degree of inaccuracy during respiratory guiding. Also, the scan angle dependence-related differences in the DTS images could reduce between using the proposed method and the established patient breathing-related sorting method. Conclusion: Through the proposed 4D DTS method, it is possible to improve the accuracy of image guidance between intra/inter fractions with relatively low imaging dose. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

Thematic Mapper Image Production in the Engineering Checkout Phase

Thematic Mapper data processing during LANDSAT 4's first year was performed on an engineering evaluation basis. Fully corrected products were created for some 282 scenes during this period using software and systems based upon the intended full production systems to become operational following the evaluation period. The engineering systems included substantial software and procedures for assessing spacecraft, instrument and ground processing algorithmic behavior. The data systems are described in terms of performance objectives, processing organization and data flow, quality assurance measurements and achievement of goals. The a priori implementation of TM radiometric and geometric corrections is described. Changes to processing suggested by or implemented on the basis of on-orbit data analysis are discussed. Spacecraft, instrument and algorithmic performance are evaluated.

Fischel, D.↗

Comparison of UNL laser imaging and sizing system and a phase Doppler system for analyzing sprays from a NASA nozzle

Research was conducted on characteristics of aerosol sprays using a P/DPA and a laser imaging/video processing system on a NASA MOD-1 air assist nozzle being evaluated for use in aircraft icing research. Benchmark tests were performed on monodispersed particles and on the NASA MOD-1 nozzle under identical lab operating conditions. The laser imaging/video processing system and the P/DPA showed agreement on a calibration tests in monodispersed aerosol sprays of + or - 2.6 micron with a standard deviation of + or - 2.6 micron. Benchmark tests were performed on the NASA MOD-1 nozzle on the centerline and radially at 0.5 inch increments to the outer edge of the spray plume at a distance 2 ft downstream from the exit nozzle. Comparative results at two operation conditions of the nozzle are presented for the two instruments. For the 1st case studied, the deviation in arithmetic mean diameters determined by the two instruments was in a range of 0.1 to 2.8 micron, and the deviation in Sauter mean diameters varied from 0 to 2.2 micron. Severe operating conditions in the 2nd case resulted in the arithmetic mean diameter deviating from 1.4 to 7.1 micron and the deviation in the Sauter mean diameters ranging from 0.4 to 6.7 micron.

Alexander, Dennis R.↗

High-Damage-Threshold Beam Shaping Using Binary Phase Plates

An approach to near-field beam shaping using a pixellated binary phase plate is presented. Continuous spatial-intensity modulation without phase modulation is obtained in an image plane of the phase plate after far-field Fourier filtering. The phase plate is a substrate with etched pixels introducing a pi-phase shift at the use wavelength. The pixel distribution is designed with a modified error-diffusion algorithm. Because of the absence of absorption from the metal layer of conventional shapers, the damage threshold of a phase shaper is mostly limited by the damage threshold of the substrate. A damage threshold of the order of 40 J/cm^2 is demonstrated in the nanosecond regime.

Dorrer, C↗