Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Fiscal Year 2022. Filtration of Hanford Tank 241-AP-101 Supernatant at 16 °C

Bench-scale filtration testing of ~9 liters of supernatant from Hanford waste tank 241-AP-101, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the performance of the anticipated third feed to the Tank Side Cesium Removal (TSCR) system. The as-received samples were diluted to the target sodium concentration and transferred to 1.5-liter polyethylene bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the TSCR action limit). This indicates that the TSCR filter should perform well when processing AP-101 supernatant. After completing filtration of the AP-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed sodium nitrate-type phases, aluminum and silicon phases reported as cancrinite or nitrate-cancrinite, a mixed chromium-aluminum oxide, iron oxides, and Ca-bearing phases (calcite). Scanning electron microscopy analyses showed that the average particle size was 0.5 micron.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water purification system

A method and system for water purification includes a particle accelerator configured to generate a particle beam and a conduit configured to be substantially in line with the particle beam wherein said electron beam is incident on a fluid flowing through the conduit. The electron beam can be oriented to be substantially head on to the direction of flow of the fluid in the conduit. A shielding assembly can be configured around the conduit. A cartridge filtering system and contaminant filtering system can be provided to remove additional contaminants.

Geelhoed, Michael↗

A CW radiofrequency ion source for production of negative hydrogen ion beams for cyclotrons

A CW 13.56 MHz radiofrequency-driven ion source RADIS for production of H{sup −} and D{sup −} beams is under development for replacing the filament-driven ion source of the MCC30/15 cyclotron. The RF ion source has a 16-pole multicusp plasma chamber, an electromagnet-based magnetic filter and an external planar spiral RF antenna behind an AlN window. The extraction is a 5-electrode system with an adjustable puller electrode voltage for optimizing the beam formation, a water-cooled electron dump electrode and an accelerating einzel lens. At 2650 W of RF power, the source produces 1 mA of H{sup −} (2.6 mA/cm{sup 2}), which is the intensity needed at injection for production of 200 µA H{sup +} with the filament-driven ion source. A simple pepperpot device has been developed for characterizing the beam emittance. Plans for improving the power efficiency with the use of a new permanent magnet front plate is discussed.

43 PARTICLE ACCELERATORS↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. Here in this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seeing through nuclear fuel: Three-dimensional, nondestructive X-ray microscopy and volumetric analyses of neutron-irradiated TRISO-coated fuel kernels

The three-dimensional (3D) characterization of nuclear fuel with X-ray microscopy has historically proven difficult, due to uranium’s high attenuation of easily accessible X-rays, both in a laboratory setting and at a synchrotron user facility. However, this imaging modality provides nondestructive information that can be used to investigate morphological changes arising from external stimuli (e.g., neutron irradiation, high-temperature testing). Using an appropriate X-ray energy spectrum and an adequate X-ray filter, suitable transmissions through properly sized nuclear fuel specimens can be achieved. Here, in this study, we present the methods and results of using a commercially available, laboratory-based X-ray microscope (XRM) to examine the extent of 3D morphological changes of tristructural isotropic (TRISO)-coated fuel particles, specifically uranium oxide/uranium carbide fuel kernels, after high-temperature neutron irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying oil filtration effects on bearing life

Rolling-element bearing life is influenced by the number, size, and material properties of particles entering the Hertzian contact of the rolling element and raceway. In general, rolling-element bearing life increases with increasing level of oil filtration. Based upon test results, two equations are presented which allow for the adjustment of bearing L(sub 10) or catalog life based upon oil filter rating. It is recommended that where no oil filtration is used catalog life be reduced by 50 percent.

Needelman, William M.↗

Growth of organized flow coherent motions within a single-stream shear layer: 4D-PTV measurements

Abstract This study investigates the evolution of a single-stream shear layer (SSSL) originating from a wall boundary layer past a backward-facing step. Utilizing a time-resolved 3D-Particle Tracking Velocimetry (4D-PTV) technique, we track the trajectories of fluorescent particles to gain insight into the flow characteristics of the SSSL. A compact water tunnel facility ( $$\textrm{Re}_\tau =1\,240$$ Re τ = 1 240 ) is fabricated to obtain an SSSL with a perpendicular slow entrainment stream past the separation edge. A hybrid interpolation approach that combines ensemble binning and Gaussian weighting is implemented to derive minimally filtered mean and instantaneous lower- and higher-order flow field parameters. Spanwise-dominant coherent motion accompanied by finer flow scales is observed to grow due to flow entrainment through “nibbling” actions of small-scale vortices, “engulfing” by large-scale vortices, and vortex pairing events. Furthermore, the non-zero-speed stream edge grows relatively faster than the zero-speed stream edge, showing a strong asymmetry in mixing composition across a mixing layer. The SSSL reaches self-similarity at a streamwise distance of $$\approx 55\,\theta _{0}$$ ≈ 55 θ 0 , where $$\theta _0$$ θ 0 is the initial momentum thickness from the separation edge, i.e., considerably shorter than reported in previous studies. A literature comparison of growth rate parameters raises intriguing questions regarding a potential inclusive growth scaling unifying the free shear layers. A turbulent kinetic energy (TKE) budget analysis reveals a negative production region immediately downstream of the separation edge attributed to a large positive streamwise gradient of streamwise velocity. In the self-similar region, the phase-averaged flow mapping demonstrates a larger concentration of turbulence production rate around the outer edges of spanwise vortices, specifically at the intersection of braids and vortices. Furthermore, a spatial separation exists in the regions of peak production and dissipation rates within the vortex core region favoring dissipation. The braids exhibit a larger concentration of turbulence diffusion rates, indicating their function as a conduit for exchanging turbulence between neighboring coherent motions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗