Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Modeling organic aerosols in a megacity: potential contribution of semi-volatile and intermediate volatility primary organic compounds to secondary organic aerosol formation

It has been established that observed local and regional levels of secondary organic aerosols (SOA) in polluted areas cannot be explained by the oxidation and partitioning of traditional anthropogenic and biogenic VOC precursors. In this study, the 3D regional air quality model CHIMERE is applied to quantify the contribution to SOA formation of recently identified semi-volatile and intermediate volatility organic vapors (S/IVOC) in and around Mexico City for the MILAGRO field experiment during March 2006. The model has been updated to explicitly include the volatility distribution of primary organic aerosols (POA), their gas-particle partitioning and the gas-phase oxidation of the vapors. Two recently proposed parameterizations, those of Robinson et al. (2007) ("ROB") and Grieshop et al. (2009) ("GRI") are compared and evaluated against surface and aircraft measurements. For the first time, 3D model results are assessed by comparing with the concentrations of OA components from Positive Matrix Factorization of Aerosol Mass Spectrometer (AMS) data, but also against and oxygen-to-carbon ratios derived from high-resolution AMS measurements. The results show a substantial enhancement in predicted SOA concentrations (3-6 times) with respect to the previously published base case without S/IVOCs (Hodzic et al., 2009), both within and downwind of the city leading to much reduced discrepancies with the total OA measurements. The predicted anthropogenic POA levels are found to agree within 20% with the observed HOA concentrations for both the ROB and GRI simulations, consistent with the interpretation of the emissions inventory by previous studies. The impact of biomass burning POA within the city is underestimated in comparison to the AMS BBOA, presumably due to insufficient nighttime smoldering emissions. Model improvements in OA predictions are associated with the better-captured SOA magnitude and diurnal variability. The production from anthropogenic and biomass burning S/IVOC represents 40-60% of the total SOA at the surface during the day and is somewhat larger than that from aromatics, especially at the T1 site at the edge of the city. The downwind SOA production from the continued multi-generation S/IVOC oxidation products actively continues. Similar to aircraft observations, the predicted OA/DCO ratio for the ROB case increases from 20-30 mg sm-3 ppm-1 up to 60-70 mg sm-3 ppm-1 between a fresh and 1-day aged air mass, while the GRI case produces a 30-40% higher OA growth than observed. The predicted average O/C ratio of total OA for the ROB case is 0.16 at T0, substantially below observed value of 0.5. A much better agreement for O/C ratios and temporal variability (R2=0.63) is achieved with the updated GRI treatment. Both treatments show a deficiency in regard to POA evolution with a tendency to over-evaporate POA upon dilution of the urban plume suggesting that atmospheric HOA may be less volatile than assumed in these parameterizations. This study highlights the very important potential role of S/IVOC chemistry in the SOA budget in this region, and highlights the need for improvements in current parameterizations. We note that other proposed pathways of SOA formation such as formation from very volatile species like glyoxal were not included in our simulations, which can also contribute SOA mass and especially increase the O/C ratio.

Hodzic, Alma↗

SU-F-J-135: Tumor Displacement-Based Binning for Respiratory-Gated Time-Independent 5DCT Treatment Planning

Purpose: A published 5DCT breathing motion model enables image reconstruction at any user-selected breathing phase, defined by the model as a specific amplitude (v) and rate (f). Generation of reconstructed phase-specific CT scans will be required for time-independent radiation dose distribution simulations. This work answers the question: how many amplitude and rate bins are required to describe the tumor motion with a specific spatial resolution? Methods: 19 lung-cancer patients with 21 tumors were scanned using a free-breathing 5DCT protocol, employing an abdominally positioned pneumatic-bellows breathing surrogate and yielding voxel-specific motion model parameters α and β corresponding to motion as a function of amplitude and rate, respectively. Tumor GTVs were contoured on the first (reference) of 25 successive free-breathing fast helical CT image sets. The tumor displacements were binned into widths of 1mm to 5mm in 1mm steps and the total required number of bins recorded. The simulation evaluated the number of bins needed to encompass 100% of the breathing-amplitude and between the 5th and 95th percentile amplitudes to exclude breathing outliers. Results: The mean respiration-induced tumor motion was 9.90mm ± 7.86mm with a maximum of 25mm. The number of bins required was a strong function of the spatial resolution and varied widely between patients. For example, for 2mm bins, between 1–13 amplitude bins and 1–9 rate bins were required to encompass 100% of the breathing amplitude, while 1–6 amplitude bins and 1–3 rate bins were required to encompass 90% of the breathing amplitude. Conclusion: The strong relationship between number of bins and spatial resolution as well as the large variation between patients implies that time-independent radiation dose distribution simulations should be conducted using patient-specific data and that the breathing conditions will have to be carefully considered. This work will lead to the assessment of the dosimetric impact of binning resolution. This study is supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

A high resolution and large solid angle x-ray Raman spectroscopy end-station at the Stanford Synchrotron Radiation Lightsource

We present a new x-ray Raman spectroscopy end-station recently developed, installed, and operated at the Stanford Synchrotron Radiation Lightsource. The end-station is located at wiggler beamline 6-2 equipped with two monochromators-Si(111) and Si(311) as well as collimating and focusing optics. It consists of two multi-crystal Johann type spectrometers arranged on intersecting Rowland circles of 1 m diameter. The first one, positioned at the forward scattering angles (low-q), consists of 40 spherically bent and diced Si(110) crystals with 100 mm diameters providing about 1.9% of 4{pi} sr solid angle of detection. When operated in the (440) order in combination with the Si (311) monochromator, an overall energy resolution of 270 meV is obtained at 6462.20 eV. The second spectrometer, consisting of 14 spherically bent Si(110) crystal analyzers (not diced), is positioned at the backward scattering angles (high-q) enabling the study of non-dipole transitions. The solid angle of this spectrometer is about 0.9% of 4{pi} sr, with a combined energy resolution of 600 meV using the Si (311) monochromator. These features exceed the specifications of currently existing relevant instrumentation, opening new opportunities for the routine application of this photon-in/photon-out hard x-ray technique to emerging research in multidisciplinary scientific fields, such as energy-related sciences, material sciences, physical chemistry, etc.

43 PARTICLE ACCELERATORS↗

A Resonant Cavity Approach to Non-Invasive, Pulse-to-Pulse EmittanceMeasurement

We present a resonant cavity approach for non-invasive, pulse-to-pulse, beam emittance measurements of non-circular multi-bunch beams. In a resonant cavity, desired field components can be enhanced up to Q{sub L{lambda}}/{pi}, where Q{sub L{lambda}} is the loaded quality factor of the resonant mode {lambda}, when the cavity resonant mode matches the bunch frequency of a bunch-train beam pulse. In particular, a quad-cavity, with its quadrupole mode (TM{sub 220} for rectangular cavities) at beam operating frequency, rotated 45{sup o} with respect to the beamline, extracts the beam quadrupole moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive beam quadrupole moment measurements, performed at different betatron phases in a linear transport system determine the beam emittance, i.e. the beam size and shape in the beam's phase space, if the beam current and position at these points are known. In the presence of x-y beam coupling, ten measurements are required. One measurement alone provides the rms-beam size of a large aspect ratio beam. The resolution for such a measurement of rms-beam size with the rectangular quad-cavity monitor presented in this article is estimated to be on the order of ten microns. A prototype quad-cavity was fabricated and preliminary beam tests were performed at the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). Results were mainly limited by beam jitter and uncertainty in the beam position measurement at the cavity location. This motivated the development of a position-emittance integrated monitor.

43 PARTICLE ACCELERATORS↗

Decoding Golden Eagle Movement Behavior from High-Resolution, Variable-Rate Telemetry Data Through Bayesian Filtering

The recent advances in animal tracking technology have enabled the collection of a vast amount of in situ data regarding the movement of wildlife at high spatiotemporal resolution. These data are usually available at variable time resolutions and contains noise (error) originating from GPS fixes. Decoding movement characteristics, particularly of flying animals, from telemetry data while handling these factors is a challenging yet important task for conservation purposes. Typically, this task is broken into two subtasks: resampling, and model calibration. The resampling subtask converts the variable rate positional data into a constant time interval data, while the model calibration subtask uses the resampled data to tune time-invariant parameters of the proposed models. For telemetry data at high temporal resolutions (order of 1 second), it is very challenging to decouple noise from actual movements using interpolation-based resampling techniques. Any errors introduced during resampling can significantly alter the the calibration and prediction attributes of the movement model. We address this problem through a unified Bayesian state-space framework that can handle both the resampling and calibration tasks in a single step. In addition, we use the speed and heading of the bird from telemetry data to regularize the position information of the bird. We use a Kalman filtering approach to include these nonlinearly related motion parameters within the state space framework. We cross-validated to quantify how this inclusion affects the model performance in estimating true bird movements. The relationship between the true state of the bird and environmental and topographical covariates is then represented parametrically. These parameters are then tuned using stochastic sampling strategies like Markov Chain Monte Carlo (MCMC). We use the telemetry data collected from golden eagles in the western USA to demonstrate the applicability of this approach to build a predictive, probabilistic movement model. Our preliminary results show that this approach provides improved predictive performance in terms of capturing higher-order motion parameters such as angular and horizontal accelerations, which may have simpler and more direct relationships with environmental covariates than corresponding speeds. In this talk, we will demonstrate how this state-space approach benefits the prediction capabilities of a movement model in simulating golden eagle paths through a wind power plant in Wyoming given certain atmospheric conditions. The model outcomes are aimed at informing mitigation strategies that can minimize the potential for collisions of golden eagles with wind turbines.

Bayesian methods↗

The (d,{sup 2}He) reaction on {sup 96}Mo and the double-{beta} decay matrix elements for {sup 96}Zr

The {sup 96}Mo(d,{sup 2}He){sup 96}Nb charge-exchange reaction was investigated at an incident energy of E{sub d}=183.5 MeV. An excitation-energy resolution of 110 keV was achieved. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 6 deg. We found that below 6 MeV almost the entire Gamow-Teller (GT{sup +}) strength is concentrated in a single state at 0.69 MeV excitation energy. As {sup 96}Mo is the daughter of the {beta}{beta} decay nucleus {sup 96}Zr, the present result provides information about the nuclear matrix elements active in the 2{nu}{beta}{beta} decay of {sup 96}Zr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning transmission electron microscopy strain measurement from millisecond frames of a direct electron charge coupled device

A high-speed direct electron detection system is introduced to the field of transmission electron microscopy and applied to strain measurements in semiconductor nanostructures. In particular, a focused electron probe with a diameter of 0.5 nm was scanned over a fourfold quantum layer stack with alternating compressive and tensile strain and diffracted discs have been recorded on a scintillator-free direct electron detector with a frame time of 1 ms. We show that the applied algorithms can accurately detect Bragg beam positions despite a significant point spread each 300 kV electron causes during detection on the scintillator-free camera. For millisecond exposures, we find that strain can be measured with a precision of 1.3 Multiplication-Sign 10{sup -3}, enabling, e.g., strain mapping in a 100 Multiplication-Sign 100 nm{sup 2} region with 0.5 nm resolution in 40 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic-Scale Structure and Stress Release Mechanism in Core–Shell Nanoparticles

According to the article, core–shell nanoparticles find applications in catalysts, sensors, and theranostics. The full internal 3D atomic structure, however, cannot be resolved by current imaging and diffraction techniques. We analyzed the atomic positions and stress-release mechanism in a cubic Au–Pd core–shell nanoparticle in approximately 1000 times higher resolution than current experimental techniques using large-scale molecular dynamics simulation to overcome these limitations. The core–shell nanocube of 73 nm size was modeled similarly to solution synthesis by random epitaxial deposition of a 4 nm thick shell of Pd atoms onto a Au core of 65 nm side length using reliable interatomic potentials. The internal structure reveals specific deformations and stress relaxation mechanisms that are caused by the +4.8% lattice mismatch of gold relative to palladium and differential confinement of extended particle facets, edges, and corners by one, two, or three Au–Pd interfaces, respectively. The three-dimensional lattice strain causes long-range, arc-like bending of atomic rows along the faces and edges of the particle, especially near the Au–Pd interface, a bulging deformation of the Pd shell, and stacking faults in the Pd shell at the corners of the particle. The strain pattern and mechanism of stress release were further characterized by profiles of the atomic layer spacing in the principal crystallographic directions. Accordingly, strain in the Pd shell is several times larger in the extended facets than near the edges and corners of the nanoparticle, which likely affects adsorption, optical, and electrochemical properties. The findings are consistent with available experimental data, including 3D reconstructions of the same cubic nanoparticle by coherent diffractive imaging (CDI) and may be verified by more powerful experimental techniques in the future. The stress release mechanisms are representative for cubic core–shell nanoparticles with fcc structure and can be explored for different shapes by the same methods.

Chemistry↗

Synthesis and Characterization of Th2N2(NH) Isomorphous to Th2N3

Using a new, low-temperature, fluoride-based process, thorium nitride imide of the chemical formula Th{sub 2}N{sub 2}(NH) was synthesized from thorium dioxide via an ammonium thorium fluoride intermediate. The resulting product phase was characterized by powder X-ray diffraction (XRD) analysis and was found to be crystallographically similar to Th{sub 2}N{sub 3}. Its unit cell was hexagonal with a space group of P3m{bar 1} and lattice parameters of a = b = 3.886(1) and c = 6.185(2) {angstrom}. The presence of -NH in the nitride phase was verified by Fourier transform infrared spectroscopy (FTIR). Total energy calculations performed using all-electron scalar relativistic density functional theory (DFT) showed that the hydrogen atom in the Th{sub 2}N{sub 2}(NH) prefers to bond with nitrogen atoms occupying 1a Wyckoff positions of the unit cell. Lattice fringe disruptions observed in nanoparticle areas of the nitride species by high-resolution transmission electron microscopic (HRTEM) images also displayed some evidence for the presence of -NH group. As ThO{sub 2} was identified as an impurity, possible reaction mechanisms involving its formation are discussed.

08 HYDROGEN↗

Factors Affecting Entrainment Rate in Deep Convective Clouds and Parameterizations

The parameterization of cloud entrainment rates has been problematic for many years, hindering the accurate representation of convective processes in large-scale models. Here, we extend our previous work on individual shallow convection to ensemble deep convection. Entrainment rates are estimated based on three-dimensional convective clouds from August 19-20 of 1999, during the Kwajalein Experiment, simulated using a high-resolution cloud-resolving model. They are found to be negatively correlated with both vertical velocity and buoyancy, and positively correlated with the vertical divergence of the vertical velocity and with the reciprocal of cloud radii. The physical mechanisms underlying these relationships are interpreted. It is found that the parameterizations with multiple properties perform better than those with a single property. Entrainment rates and relative humidity of entrained air are positively correlated at temperature higher than 0°C, but negatively correlated at temperature lower than 0°C. Relative humidity is also included in the parameterization of entrainment rates, which differs from our previous work on shallow cumulus clouds and other studies. Finally, two forms of parameterization for entrainment rate are recommended. The first treats the entrainment rate as a function of the vertical velocity and buoyancy for temperature higher than 0°C, but as a function of relative humidity and buoyancy for temperature lower than 0°C. The second involves an equation that relates entrainment rates to vertical velocity and buoyancy regardless of temperature.

54 ENVIRONMENTAL SCIENCES↗

A novel approach to quantitative spectroscopy of atoms in a magnetic field and applications based on an atomic vapor cell with L={lambda}

We describe the so-called {lambda}-Zeeman method to investigate individual hyperfine transitions between Zeeman sublevels of atoms in an external magnetic field of 0.1 mT-0.25 T. Atoms are confined in a nanocell with thickness L={lambda}, where {lambda} is the resonant wavelength (794 or 780 nm for D{sub 1} or D{sub 2} line, respectively, of Rb). Narrow resonances in the transmission spectrum of the nanocell are split into several components in a magnetic field; their frequency positions and transition probabilities depend on the B field. Possible applications are described, such as magnetometers with nanometric spatial resolution and tunable atomic frequency references.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strong magnetohydrodynamic turbulence with cross helicity

Magnetohydrodynamics (MHD) provides the simplest description of magnetic plasma turbulence in a variety of astrophysical and laboratory systems. MHD turbulence with nonzero cross helicity is often called imbalanced, as it implies that the energies of Alfven fluctuations propagating parallel and antiparallel the background field are not equal. Recent analytical and numerical studies have revealed that at every scale, MHD turbulence consists of regions of positive and negative cross helicity, indicating that such turbulence is inherently locally imbalanced. In this paper, results from high resolution numerical simulations of steady-state incompressible MHD turbulence, with and without cross helicity are presented. It is argued that the inertial range scaling of the energy spectra (E{sup +}-) of fluctuations moving in opposite directions is independent of the amount of cross helicity. When cross helicity is nonzero, E{sup +} and E{sup -} maintain the same scaling, but have differing amplitudes depending on the amount of cross helicity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The TREK/E36 experiment at J-PARC

Experiment E36 is planned to run at the J-PARC K1.1BR kaon beamline in 2014-15 using a stopped kaon beam along with the TREK target and detector setup. The decay products of stopped positive kaons will be observed with a large-acceptance toroidal spectrometer capable of tracking charged particles with high resolution, combined with a photon calorimeter with large solid angle and redundant particle identification systems. With the aim to test lepton universality in the K{sub e2}/K{sub μ2} ratio with high precision, the experiment is highly sensitive to new physics beyond the Standard Model. A further goal of E36 is to search for a heavy sterile neutrino in two-body kaon decay, along with additional searches for exotic decay modes including the possibility to produce a dark photon and to observe its decay into an e{sup +}e{sup −} pair. An overview of the planned measurements with E36 will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

From Schottky to Ohmic graphene contacts to AlGaN/GaN heterostructures: Role of the AlGaN layer microstructure

The electrical behaviour of graphene (Gr) contacts to Al{sub x}Ga{sub 1−x}N/GaN heterostructures has been investigated, focusing, in particular, on the impact of the AlGaN microstructure on the current transport at Gr/AlGaN interface. Two Al{sub 0.25}Ga{sub 0.75}N/GaN heterostructures with very different quality in terms of surface roughness and defectivity, as evaluated by atomic force microscopy (AFM) and transmission electron microscopy, were compared in this study, i.e., a uniform and defect-free sample and a sample with a high density of typical V-defects, which locally cause a reduction of the AlGaN thickness. Nanoscale resolution current voltage (I-V) measurements by an Au coated conductive AFM tip were carried out at several positions both on the bare and Gr-coated AlGaN surfaces. Rectifying contacts were found onto both bare AlGaN surfaces, but with a more inhomogeneous and lower Schottky barrier height (Φ{sub B} ≈ 0.6 eV) for AlGaN with V-defects, with respect to the case of the uniform AlGaN (Φ{sub B} ≈ 0.9 eV). Instead, very different electrical behaviours were observed in the presence of the Gr interlayer between the Au tip and AlGaN, i.e., a Schottky contact with reduced barrier height (Φ{sub B} ≈ 0.4 eV) for the uniform AlGaN and an Ohmic contact for the AlGaN with V-defects. Interestingly, excellent lateral uniformity of the local I-V characteristics was found in both cases and can be ascribed to an averaging effect of the Gr electrode over the AlGaN interfacial inhomogeneities. Due to the locally reduced AlGaN layer thickness, V defect act as preferential current paths from Gr to the 2DEG and can account for the peculiar Ohmic behaviour of Gr contacts on defective AlGaN.

36 MATERIALS SCIENCE↗

Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the electron energy distribution in moving striations at low gas pressures

The time-resolved Electron Energy Distribution Functions (EEDFs) have been measured at different phases of moving striations in a positive column of DC discharge in argon gas. A very low gas pressure of 10 mTorr, a high energy resolution (to resolve the low energy part of the EEDF), and the dynamic range up to 3–4 orders of magnitude (to resolve the EEDF tail) with a temporal resolution of 2.5 μs distinguish our work from previous publications. The measured EEDFs reveal drastic changes in time of their low energy parts with the formation of a low energy peak. The observed EEDF dynamics is explained in the framework of nonlocal electron kinetics as electric field reversals and the trapping of low-energy electrons in potential wells propagating with striation along the discharge tube. Finally, the formation of the low energy peak in the EEDF is similar to that in rf capacitive and inductive discharges at low gas pressures where the low-energy electrons are trapped in the potential well created by the ambipolar electric field and cannot penetrate into the areas of electron heating by strong rf electric fields

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗