Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Complex Indigenous Organic Matter Embedded in Apollo 17 Volcanic Black Glass Surface Deposits

Papers presented at the first Lunar Science Conference [1] and those published in the subsequent Science Moon Issue [2] reported the C content of Apollo II soils, breccias, and igneous rocks as rang-ing from approx.50 to 250 parts per million (ppm). Later Fegley & Swindle [3] summarized the C content of bulk soils from all the Apollo missions as ranging from 2.5 (Apollo 15) to 280 ppm (Apollo 16) with an overall average of 124+/- 45 ppm. These values are unexpectedly low given that multiple processes should have contributed (and in some cases continue to contribute) to the lunar C inventory. These include exogenous accretion of cometary and asteroidal dust, solar wind implantation, and synthesis of C-bearing species during early lunar volcanism. We estimate the contribution of C from exogenous sources alone is approx.500 ppm, which is approx.4x greater than the reported average. While the assessm ent of indigenous organic matter (OM) in returned lunar samples was one of the primary scientific goals of the Apollo program, extensive analysis of Apollo samples yielded no evidence of any significant indigenous organic species. Furthermore, with such low concentrations of OM reported, the importance of discriminating indigenous OM from terrestrial contamination (e.g., lunar module exhaust, sample processing and handling) became a formidable task. After more than 40 years, with the exception of CH4 [5-7], the presence of indigenous lunar organics still remains a subject of considerable debate. We report for the first time the identification of arguably indigenous OM present within surface deposits of black glass grains collected on the rim of Shorty crater during the Apollo 17 mission by astronauts Eugene Cernan and Harrison Schmitt.

Thomas-Keprta, Kathie L.↗

Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water

The presence of water-ice in the Martian subsurface is a subject of much debate and excited speculation. Recent results from the gammaray spectrometer (GRS) on board NASA's Mars Odyssey spacecraft indicate the presence of large amounts of hydrogen in regions of predicted ice stability. The combination of chemistry, low gravitational field (3.71 m/s(exp 2)) and a surface pressure of about 6.36 mbar at the mean radius, place limits on the stability of H2O on the surface, however, results from the GRS indicate that the hydrogen rich phase may be present at a depth as shallow as one meter in some locations on Mars. The potential for water on Mars leads directly to the speculation that life may once have existed there, since liquid water is the unifying factor for environments known to support life on Earth. Lubricant-free drilling has been considered as a means of obtaining water-rich subsurface samples on Mars, and two recent white papers sponsored by the Mars Program have attempted to identify the problems associated with this goal. The two major issues identified were: the engineering challenges of drilling into a water-soil mixture where phase changes may occur; and the potential to compromise the integrity of in-situ scientific analysis due to contamination, volatilization, and mineralogical or chemical changes as a result of processing. This study is a first attempt to simulate lubricantfree drilling into JSC Mars-1 simulant containing up to 50% water by weight. The goal is to address the following: 1) Does sample processing cause reactions or changes in mineralogy which will compromise the interpretation of scientific measurements conducted on the surface? 2) Does the presence of water-ice in the sample complicate (1)? 3) Do lubricant-free drilling and processing leave trace contaminants which may compromise our understanding of sample composition? 4) How does the torque/power required for drilling change as a function of water content and does this lead to unexpected thermal effects?

Menard, J.↗

Mineralogy and Elemental Composition of Wind Drift Soil at Rocknest, Gale Crater

The Mars Science Laboratory rover Curiosity has been exploring Mars since August 5, 2012, conducting engineering and first-time activities with its mobility system, arm, sample acquisition and processing system (SA/SPaH-CHIMRA) and science instruments. Curiosity spent 54 sols at a location named "Rocknest," collecting and processing five scoops of loose, unconsolidated materials ("soil") acquired from an aeolian bedform (Fig. 1). The Chemistry and Mineralogy (CheMin) instrument analyzed portions of scoops 3, 4, and 5, to obtain the first quantitative mineralogical analysis of Mars soil, and to provide context for Sample Analysis at Mars (SAM) measurements of volatiles, isotopes and possible organic materials.

Blake, D. F.↗

Chlorine Isotopes: As a Possible Tracer of Fluid/Bio-Activities on Mars and a Progress Report on Chlorine Isotope Analysis by TIMs

Significantly large mass fractionations between chlorine isotopes (Cl-35, Cl-37) have been reported for terrestrial materials including both geological samples and laboratory materials. Also, the chlorine isotopic composition can be used as a tracer for early solar system processes. Moreover, chlorine is ubiquitous on the Martian surface. Typical chlorine abundances in Gusev soils are approx.0.5 %. The global surface average chlorine abundance also is approx.0.5 %. Striking variations among outcrop rocks at Meridiani were reported with some chlorine abundances as high as approx.2%. Characterizing conditions under which chlorine isotopic fractionation may occur is clearly of interest to planetary science. Thus, we have initiated development of a chlorine isotopic analysis technique using TIMS at NASA-JSC. We present here a progress report on the current status of development at JSC and discuss the possible application of chlorine isotopic analysis to Martian meteorites in a search for fluid- and possibly biological activity on Mars.

Nakamura, N.↗

Sampling-based Uncertainty Quantification in Deconvolution of X-ray Radiographs

In imaging applications that focus on quantitative analysis{such as X-ray radiography in the security sciences--it is necessary to be able to reliably estimate the uncertainties in the processing algorithms applied to the image data, and deconvolving the system blur out of the image is usually an essential step. In this work we solve the deconvolution problem within a Bayesian framework for edge-enhancing reconstruction with uncertainty quantification. The likelihood is a normal approximation to the Poisson likelihood, and the prior is generated from a classical total variation regularized Poisson deconvolution. Samples from the corresponding posterior distribution are computed using a Markov chain Monte Carlo approach, giving a pointwise measure of uncertainty in the final, deconvolved signal. We demonstrate the results on real data used to calibrate a high-energy X-ray source and show that this approach gives reconstructions as good as classical regularization methods, while mitigating many of their drawbacks.

Deconvolution, Inverse Problems, Markov Chain Mont↗

Stellar s-process neutron capture cross sections on 78,80,84,86 Kr determined via activation, atom trap trace analysis and decay counting

We present a detailed account of neutron capture experiments of astrophysical relevance on 78,80,84,86 Kr (n, γ) reactions at the border between weak and main s process. The experiments were performed with quasi-Maxwellian neutrons from the Liquid-Lithium Target (LiLiT) and the mA-proton beam at 1.93 MeV (2-3 kW) of the Soreq Applied Research Accelerator Facility (SARAF). The setup yields high-intensity approximate to 40 keV quasi-Maxwellian neutrons (3-5 x10 10 n/s) closely reproducing the conditions of s-process stellar nucleosynthesis. A sample of 100 mg of atmospheric, pre-nuclear-age Kr gas contained in a Ti spherical shell was activated in the LiLiT neutron field. The abundances of long-lived Kr isotopes ( 81,85g Kr) were measured by atom counting via atom trap trace analysis (ATTA) at Argonne National Laboratory and low-level counting (LLC) at University of Bern. This work is the first measurement of a nuclear cross section using atom counting via ATTA. The activities of short-lived Kr isotopes ( 79,85m,87 Kr) were measured by gamma-decay counting with a high-purity germanium detector. Maxwellian-averaged cross sections for s-process thermal energies are extracted. By comparison to reference values, our nucleosynthesis network calculations show that the experimental cross sections have a strong impact on calculated abundances of krypton and neighboring nuclides, in some cases improving agreement between theory and observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test Bed: Treatability of Hanford Tank Waste - 18501

In an effort to advance the Low Activity Waste Pretreatment System technology readiness level at the Hanford Site, the effectiveness of a critical technology element, sRF ion-exchange resin, was demonstrated in the selective removal of Cs-137 from 11.5 L of composited Hanford supernate tank waste. Prior to ion-exchange, solids filtration was performed on the tank waste composite. Between the time of filtrate collection and filtrate processing on the ion-exchange columns, additional solids had formed. These secondary solids resulted from the combination of supernates high in fluoride content with supernates high in phosphate content and the relatively short blend time. Samples were collected before, during and after the ion-exchange process for characterization of a full suite of constituents (inorganic, organic, and radionuclides) to aid in the classification of the cesium-removed waste for shipping, receiving, treatment, and disposal determinations. Following chemical analysis, the remaining 10.8 L (2.9 gal) of cesium-depleted waste was shipped to an off-site vendor for grout-encapsulation and eventual disposal at the Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas as low-level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A joint analysis of Planck and BICEP2 B modes including dust polarization uncertainty

We analyze BICEP2 and Planck data using a model that includes CMB lensing, gravity waves, and polarized dust. Recently published Planck dust polarization maps have highlighted the difficulty of estimating the amount of dust polarization in low intensity regions, suggesting that the polarization fractions have considerable uncertainties and may be significantly higher than previous predictions. In this paper, we start by assuming nothing about the dust polarization except for the power spectrum shape, which we take to be C{sub l}{sup BB,dust} ∝ l{sup -2.42}. The resulting joint BICEP2+Planck analysis favors solutions without gravity waves, and the upper limit on the tensor-to-scalar ratio is r<0.11, a slight improvement relative to the Planck analysis alone which gives r<0.13 (95% c.l.). The estimated amplitude of the dust polarization power spectrum agrees with expectations for this field based on both HI column density and Planck polarization measurements at 353 GHz in the BICEP2 field. Including the latter constraint on the dust spectrum amplitude in our analysis improves the limit further to r < 0.09, placing strong constraints on theories of inflation (e.g., models with r>0.14 are excluded with 99.5% confidence). We address the cross-correlation analysis of BICEP2 at 150 GHz with BICEP1 at 100 GHz as a test of foreground contamination. We find that the null hypothesis of dust and lensing with 0r= gives Δ χ{sup 2} < 2 relative to the hypothesis of no dust, so the frequency analysis does not strongly favor either model over the other. We also discuss how more accurate dust polarization maps may improve our constraints. If the dust polarization is measured perfectly, the limit can reach r < 0.05 (or the corresponding detection significance if the observed dust signal plus the expected lensing signal is below the BICEP2 observations), but this degrades quickly to almost no improvement if the dust calibration error is 20% or larger or if the dust maps are not processed through the BICEP2 pipeline, inducing sampling variance noise.

79 ASTRONOMY AND ASTROPHYSICS↗

DNA Ploidy Measured on Archived Pretreatment Biopsy Material May Correlate With Prostate-Specific Antigen Recurrence After Prostate Brachytherapy

Purpose: To explore whether DNA ploidy of prostate cancer cells determined from archived transrectal ultrasound-guided biopsy specimens correlates with disease-free survival. Methods and Materials: Forty-seven failures and 47 controls were selected from 1006 consecutive low- and intermediate-risk patients treated with prostate {sup 125}I brachytherapy (July 1998-October 2003). Median follow-up was 7.5 years. Ten-year actuarial disease-free survival was 94.1%. Controls were matched using age, initial prostate-specific antigen level, clinical stage, Gleason score, use of hormone therapy, and follow-up (all P nonsignificant). Seventy-eight specimens were successfully processed; 27 control and 20 failure specimens contained more than 100 tumor cells were used for the final analysis. The Feulgen-Thionin stained cytology samples from archived paraffin blocks were used to determine the DNA ploidy of each tumor by measuring integrated optical densities. Results: The samples were divided into diploid and aneuploid tumors. Aneuploid tumors were found in 16 of 20 of the failures (80%) and 8 of 27 controls (30%). Diploid DNA patients had a significantly lower rate of disease recurrence (P=.0086) (hazard ratio [HR] 0.256). On multivariable analysis, patients with aneuploid tumors had a higher prostate-specific antigen failure rate (HR 5.13). Additionally, those with “excellent” dosimetry (V100 >90%; D90 >144 Gy) had a significantly lower recurrence rate (HR 0.25). All patients with aneuploid tumors and dosimetry classified as “nonexcellent” (V100 <90%; D90 <144 Gy) (5 of 5) had disease recurrence, compared with 40% of patients with aneuploid tumors and “excellent” dosimetry (8 of 15). In contrast, dosimetry did not affect the outcome for diploid patients. Conclusions: Using core biopsy material from archived paraffin blocks, DNA ploidy correctly classified the majority of failures and nonfailures in this study. The results suggest that DNA ploidy can be used as a useful marker for aggressiveness of localized prostate cancer. A larger study will be necessary to further confirm our hypothesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blind identification of full-field vibration modes of output-only structures from uniformly-sampled, possibly temporally-aliased (sub-Nyquist), video measurements

Enhancing the spatial and temporal resolution of vibration measurements and modal analysis could significantly benefit dynamic modelling, analysis, and health monitoring of structures. For example, spatially high-density mode shapes are critical for accurate vibration-based damage localization. In experimental or operational modal analysis, higher (frequency) modes, which may be outside the frequency range of the measurement, contain local structural features that can improve damage localization as well as the construction and updating of the modal-based dynamic model of the structure. In general, the resolution of vibration measurements can be increased by enhanced hardware. Traditional vibration measurement sensors such as accelerometers have high-frequency sampling capacity; however, they are discrete point-wise sensors only providing sparse, low spatial sensing resolution measurements, while dense deployment to achieve high spatial resolution is expensive and results in the mass-loading effect and modification of structure's surface. Non-contact measurement methods such as scanning laser vibrometers provide high spatial and temporal resolution sensing capacity; however, they make measurements sequentially that requires considerable acquisition time. As an alternative non-contact method, digital video cameras are relatively low-cost, agile, and provide high spatial resolution, simultaneous, measurements. Combined with vision based algorithms (e.g., image correlation or template matching, optical flow, etc.), video camera based measurements have been successfully used for experimental and operational vibration measurement and subsequent modal analysis. However, the sampling frequency of most affordable digital cameras is limited to 30–60 Hz, while high-speed cameras for higher frequency vibration measurements are extremely costly. This work develops a computational algorithm capable of performing vibration measurement at a uniform sampling frequency lower than what is required by the Shannon-Nyquist sampling theorem for output-only modal analysis. In particular, the spatio-temporal uncoupling property of the modal expansion of structural vibration responses enables a direct modal decoupling of the temporally-aliased vibration measurements by existing output-only modal analysis methods, yielding (full-field) mode shapes estimation directly. Then the signal aliasing properties in modal analysis is exploited to estimate the modal frequencies and damping ratios. Furthermore, the proposed method is validated by laboratory experiments where output-only modal identification is conducted on temporally-aliased acceleration responses and particularly the temporally-aliased video measurements of bench-scale structures, including a three-story building structure and a cantilever beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface characterization of InP trenches embedded in oxide using scanning probe microscopy

Metrology for structural and electrical analyses at device level has been identified as one of the major challenges to be resolved for the sub-14 nm technology nodes. In these advanced nodes, new high mobility semiconductors, such as III–V compounds, are grown in narrow trenches on a Si substrate. Probing the nature of the defects, the defect density, and the role of processing steps on the surface of such structures are prime metrology requirements. In order to enable defect analysis on a (III–V) surface, a proper sample preparation for oxide removal is of primary importance. In this work, the effectiveness of different chemical cleanings and thermal annealing procedures is investigated on both blanket InP and oxide embedded InP trenches by means of scanning probe microscopy techniques. It is found that the most effective approach is a combination of an HCl-based chemical cleaning combined with a low-temperature thermal annealing leading to an oxide free surface with atomically flat areas. Scanning tunneling microscopy (STM) has been the preferred method for such investigations on blanket films due to its intrinsic sub-nm spatial resolution. However, its application on oxide embedded structures is non-trivial. To perform STM on the trenches of interest (generally <20 nm wide), we propose a combination of non-contact atomic force microscopy and STM using the same conductive atomic force microscopy tip Our results prove that with these procedures, it is possible to perform STM in narrow InP trenches showing stacking faults and surface reconstruction. Significant differences in terms of roughness and terrace formation are also observed between the blanket and the oxide embedded InP.

36 MATERIALS SCIENCE↗

Partial wave analysis of 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓 and cross section measurement of 𝑒 + ⁢𝑒 − → 𝜋 ± ⁢𝑍 𝑐 ⁢(3900) ∓ from 4.1271 to 4.3583 GeV

Based on 12.0 fb −1 of 𝑒 + ⁢𝑒 − collision data samples collected by the BESIII detector at center-of-mass energies from 4.1271 to 4.3583 GeV, a partial wave analysis is performed for the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. The cross sections for the subprocesses 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝑍 𝑐 ⁢(3900) − + c.c. → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓, 𝑓 0 ⁡(980)⁢(→ 𝜋 + ⁢𝜋 − )⁢𝐽/𝜓, and (𝜋 + ⁢𝜋 − ) S−wave⁢ 𝐽/𝜓 are measured for the first time. The mass and width of the 𝑍 𝑐 ⁢(3900) ± are determined to be 3884.6 ± 0.7 ± 3.3 MeV/𝑐 2 and 37.2 ± 1.3 ± 6.6 MeV, respectively. The first errors are statistical and the second systematic. The final state (𝜋 + ⁢𝜋 − ) S−wave ⁢𝐽/𝜓 dominates the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. By analyzing the cross sections of 𝜋 ±⁢ 𝑍 𝑐 ⁢(3900) ∓ and 𝑓 0 ⁡(980)⁢𝐽/𝜓, 𝑌⁡(4220) has been observed. Its mass and width are determined to be 4225.7 ± 4.1 ± 3.4 MeV/𝑐 2 and 57.5 ± 9.4 ± 12.1 MeV, respectively.

lepton colliders↗

Simulation of Thematic Mapper performance as a function of sensor scanning parameters

The investigation and results of the Thematic Mapper Instrument Performance Study are described. The Thematic Mapper is the advanced multispectral scanner initially planned for the Earth Observation Satellite and now planned for LANDSAT D. The use of existing digital airborne scanner data obtained with the Modular Multispectral Scanner (M2S) at Bendix provided an opportunity to simulate the effects of variation of design parameters of the Thematic Mapper. Analysis and processing of this data on the Bendix Multispectral Data Analysis System were used to empirically determine categorization performance on data generated with variations of the sampling period and scan overlap parameters of the Thematic Mapper. The Bendix M2S data, with a 2.5 milliradian instantaneous field of view and a spatial resolution (pixel size) of 10-m from 13,000 ft altitude, allowed a direct simulation of Thematic Mapper data with a 30-m resolution. The flight data chosen were obtained on 30 June 1973 over agricultural test sites in Indiana.

Johnson, R. H.↗

Automated chromosome analysis

Minicomputer-controlled system automatically prepares and analyses blood samples and displays karyotype in pictorial form as primary output. System accuracy is assured by operator interaction at key points during process. System can process up to 576 specimens per day.

Castleman, K. R.↗

A volatile organics concentrator for use in monitoring Space Station water quality

The process used to identify, select, and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is discerned. The trade analysis leading to the recommended volatile organics concentrator (VOC) concept to be tested in a breadboard device is presented. The system covers the areas of gases, volatile separation from water, and water removal/gas chromatograph/mass spectrometer interface. Five options for potential use in the VOC and GC/MS system are identified and ranked, and also nine options are presented for separation of volatiles from the water phase. Seven options for use in the water removal/GC column and MS interface are also identified and included in the overall considerations. A final overall recommendation for breadboard VOC testing is given.

Ehntholt, Daniel J.↗

Compositional analysis of projectile residues on LDEF instrument AO187-1

Impact craters greater than 30 microns and associated projectile residues were analyzed by Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Analysis (EDXA). Objectives were to analyze a statistically significant number of projectiles to evaluate their chemical variability and possible clustering into discrete particle types. Bay A11 exposed six collector surfaces of anodized 1100-T4 (greater than 99 percent pure) aluminum sheets, 0.32 cm thick, yielding an exposed surface area of 1.1 sq. m. Four of the six panels have been retained at JSC, and were optically scanned, one (A11E00E) was prepared for SEM/EDX analysis. Bay A03 was occupied by high purity (99.99 percent) gold sheets, 0.5 mm thick, yielding an exposed surface area of 0.85 sq. m. Sample processing included the optical scanning (6X), labeling, and dislodging (by a punch-die device) of each individual impact greater than 75 microns for the aluminum and 30 microns for the gold. The 209 craters were dislodged form A11E00E, having crater diameters up to 3500 microns. Optical examination of the gold surfaces detected 238 craters, 198 of which were retained at JSC and analyzed via SEM/EDX. The analytical procedures included maximizing the geometric efficiency (take-off angles), using relatively long count times (500-1000 sec) and sufficiently high accelerating currents (25-30Kev). Despite diligent examination, a large number of craters did not exhibit measurable signals above background. Detectable resides were classified as either micrometeoritic or as man-made debris.

Bernhard, Ronald P.↗

Fixture For Sampling Volatile Materials In Containers

Fixture based on T-connector enables mass-spectrometric analysis of volatile contents of cylindrical containers without exposing contents to ambient conditions. Used to sample volatile contents of pressurized containers, contents of such enclosed processing systems as gas-phase reactors, gases in automotive emission systems, and gas in hostile environments.

Melton, Donald↗