Search NASA⌕ Search

SEARCH · Search NASA

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Environmental Remediation Science at Beamline X26A at the National Synchrotron Light Source- Final Report

The goal of this project was to provide support for an advanced X-ray microspectroscopy facility at the National Synchrotron Light Source, Brookhaven National Laboratory. This facility is operated by the University of Chicago and the University of Kentucky. The facility is available to researchers at both institutions as well as researchers around the globe through the general user program. This facility was successfully supported during the project period. It provided access to advanced X-ray microanalysis techniques which lead to fundamental advances in understanding the behavior of contaminants and geochemistry that is applicable to environmental remediation of DOE legacy sites as well as contaminated sites around the United States and beyond.

54 ENVIRONMENTAL SCIENCES↗

Develop and Test TXM Battery Cells

Summary of the specific research and project accomplishments: The team combined their knowledge and expertise in x-ray science and electrochemistry to quantify lithium concentration gradients for commercially relevant metal oxide cathodes at rates up to 6C. Completion of the project required several significant technical developments including new x-ray experimental methodologies, high-speed and high-accuracy sample multiplexers and a new class of x-ray compatible cells. The results from thin and thick electrodes demonstrated that both spatial heterogeneity and concentration gradients through the thickness of the cathode may be present. The relevance of either phenomena appears to be correlated to aspects of the electrode such as calendaring in addition to the configuration of the experiment (e.g. force between the anode and cathode).

25 ENERGY STORAGE↗

A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors' results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 {mu}m{sup 3} voxels (larger 500 {mu}m{sup 2} detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant or increase slightly with scan angle. 2. In the same regime, when the authors fixed the scan angle, AUC increased asymptotically with the number of projections. The threshold number of projections for asymptotic AUC performance depended on the scan angle. In the quantum- and electronic-noise dominant regimes, AUC behaviors as a function of scan angle and number of projections sometimes differed from the anatomy-limited regime. For example, with a fixed scan angle, AUC generally decreased with the number of projections in the electronic-noise dominant regime. These results are intended to demonstrate the capabilities of the virtual trial framework, not to be used as optimization rules for DBT. Conclusions: The authors have demonstrated a novel simulation framework and tools for evaluating DBT systems in an objective, task-specific manner. This framework facilitates further investigation of image quality tradeoffs in DBT.

60 APPLIED LIFE SCIENCES↗

SUNYAEV-ZEL'DOVICH EFFECT OBSERVATIONS OF THE BULLET CLUSTER (1E 0657-56) WITH APEX-SZ

We present observations of the Sunyaev-Zel'dovich effect (SZE) in the Bullet cluster (1E 0657-56) using the APEX-SZ instrument at 150 GHz with a resolution of 1'. The main results are maps of the SZE in this massive, merging galaxy cluster. The cluster is detected with 23{sigma} significance within the central 1' radius of the source position. The SZE map has a broadly similar morphology to that in existing X-ray maps of this system, and we find no evidence for significant contamination of the SZE emission by radio or IR sources. In order to make simple quantitative comparisons with cluster gas models derived from X-ray observations, we fit our data to an isothermal elliptical {beta} model, despite the inadequacy of such a model for this complex merging system. With an X-ray-derived prior on the power-law index, {beta} = 1.04{sup +0.16} {sub -0.10}, we find a core radius r {sub c} = 142'' {+-} 18'', an axial ratio of 0.889 {+-} 0.072, and a central temperature decrement of -771 {+-} 71 {mu}K{sub CMB}, including a {+-}5.5% flux calibration uncertainty. Combining the APEX-SZ map with a map of projected electron surface density from Chandra X-ray observations, we determine the mass-weighted temperature of the cluster gas to be T {sub mg} = 10.8 {+-} 0.9 keV, significantly lower than some previously reported X-ray spectroscopic temperatures. Under the assumption of an isothermal cluster gas distribution in hydrostatic equilibrium, we compute the gas mass fraction for prolate and oblate spheroidal geometries and find it to be consistent with previous results from X-ray and weak-lensing observations. This work is the first result from the APEX-SZ experiment, and represents the first reported scientific result from observations with a large array of multiplexed superconducting transition-edge sensor bolometers.

99 GENERAL AND MISCELLANEOUS↗

THE SEARCH FOR LOW-MASS COMPANIONS OF B STARS IN THE CARINA NEBULA CLUSTER TRUMPLER 16

We have developed lists of likely B3-A0 stars (called 'late B' stars) in the young cluster Trumpler 16. The following criteria were used: location within 3' of {eta} Car, an appropriate V and B - V combination, and proper motion (where available). Color and magnitude cuts have been made assuming an E(B - V) = 0.55 mag {+-} 0.1, which is a good approximation close to the center of Trumpler 16. These lists have been cross-correlated with X-ray sources found in the Chandra Carina Complex Project. Previous studies have shown that only very rarely (if at all) do late main-sequence B stars produce X-rays. We present evidence that the X-ray-detected sources are binaries with low-mass companions, since stars less massive than 1.4 M{sub sun} are strong X-ray sources at the age of the cluster. Both the median X-ray energies and X-ray luminosities of these sources are in good agreement with values for typical low-mass coronal X-ray sources. We find that 39% of the late B stars based on a list with proper motions have low-mass companions. Similarly, 32% of a sample without proper motions have low-mass companions. We discuss the X-ray detection completeness. These results on low-mass companions of intermediate-mass stars are complementary to spectroscopic and interferometric results and probe new parameter space of low-mass companions at all separations. They do not support a steeply rising distribution of mass ratios to low masses for intermediate-mass (5 M{sub sun}) primaries, such as would be found by random pairing from the initial mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

Large-x partons from Jefferson Lab to the LHC

This project addressed the longitudinal quark and gluon structure of hadrons, a key topic in the 2015 and 2023 NSAC long range plans for nuclear science. The research encompassed and combined theoretical studies with advanced Quantum Chromo Dynamics (QCD) analysis of experimental data, from Jefferson Lab to the Large Hadron Collider. The results have pushed the boundaries in both aspects, and capitalized on the results and methods developed in previous grant renewals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A MINI X-RAY SURVEY OF SUB-DAMPED LYMAN-ALPHA ABSORPTION SYSTEMS: SEARCHING FOR ACTIVE GALACTIC NUCLEI FORMED IN PROTOGALAXIES

A significant fraction of the sub-damped Lyman-alpha (sub-DLA) absorption systems in quasar spectra appear to be metal-rich, including many with even super-solar element abundances. This raises the question whether some sub-DLAs may harbor active galactic nuclei (AGNs), since supersolar metallicities are observed in AGNs. Here, we investigate this question based on a mini-survey of 21 quasars known to contain sub-DLAs in their spectra. The X-ray observations were performed with the Chandra X-ray Observatory. In cases of no detection, we estimated upper limits for the X-ray luminosities of possible AGNs at the redshifts of the sub-DLAs. In six cases, we find possible X-ray emission within ∼1'' of the background quasar, which is consistent with the presence of a nearby X-ray source. If these nearby X-ray sources are at the redshifts of the sub-DLAs, then their estimated 0.2-10 keV luminosities range between 0.8 × 10{sup 44} h {sup –2} and 4.2 × 10{sup 44} h {sup –2} erg s{sup –1}, thus ruling out a normal late-type galaxy origin, and suggesting that the emission originates in a galactic nucleus near the center of a protogalaxy. The projected distances of these possible nearby X-ray sources from the background quasars lie in the range of 3-7 h {sup –1} kpc, which is consistent with our hypothesis that they represent AGNs centered on the sub-DLAs. Deeper follow-up X-ray and optical observations are required to confirm the marginal detections of X-rays from these sub-DLA galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1E 0104.2 + 3153 - A broad absorption-line QSO viewed through a giant elliptical galaxy

The optical identification of the X-ray source 1E 0104.2 + 3153 is complicated by the close projection of a broad absorption-line (BAL) QSO (z = 2.027) 10 arcsec from a giant elliptical galaxy (z = 0.111) at the center of a compact group of galaxies. At only 1.2 de Vaucouleur radii (16 kpc for H sub 0 = 100 km/s Mpc) this QSO-galaxy projection is the closest yet discovered. Based upon current observations, the source of the X-ray emission cannot be conclusively determined. Present in the BAL QSO spectrum are extremely strong Ca II H and K absorption lines due to the intervening galaxy, the first optical detection of the cold interstellar medium in an elliptical galaxy. The strength of these lines (EW = 2 and 1 A) requires observation through several interstellar clouds in the line of sight to the QSO. By its proximity to the central regions of the elliptical galaxy and the relative distances of the galaxy and QSO, this QSO is a particularly good candidate for observing dramatic transient gravitational lensing phenomena due to halo stars in the foreground galaxy.

Stocke, J. T.↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Light for Berkeley Lab—the Advanced Light Source Upgrade

The Advanced Light Source Upgrade Project (ALS-U) will leverage multibend achromat technology to endow the ALS with revolutionary soft X-ray capabilities, and has recently received formal approval to proceed to the preliminary design phase. Soft X-rays are a critical diagnostic tool for enabling the understanding and control of heterogeneous, hierarchical functional materials and chemical synthesis platforms since they can reveal chemical, electronic, and magnetic properties with very high sensitivity. Although the ALS has a strong track record in soft X-ray science over the last 25 years, it, like most other existing storage-ring-based X-ray light sources, lacks the simultaneous combination of nanometer spatial resolution, diverse spectroscopic contrast, and broad temporal sensitivity required to image the location of molecules, ions, and electrons, and to measure how their components migrate and interact to support efficient function. The high coherent flux of the upgraded ALS willenable a suite of tools that encompass 3D nanoscale imaging with high spectral sensitivity over broad space and time scales, dramatically amplifying the already high impact of ALS soft X-ray spectroscopies. Relative to many other synchrotron light source upgrade projects or new facilities being built today, the upgraded ALS will operate at a low electron-beam energy of 2 GeV and a high current of 500 mA, and is optimized for soft X-rays. Its soft X-ray coherent flux will be orders of magnitude higher than that of the existing ALS and beyond the coherent flux of any storage-ring-based light source operating, under construction, or currently planned. In total, the upgraded facility will provide an unprecedented combination of high stability, quasi-continuous radiation, and the highest possible coherent soft X-ray flux.

47 OTHER INSTRUMENTATION↗

Customized multi-group cross section generation with NJOY for discrete ordinates X-ray computed tomography and radiography simulation - 25589

The purpose of this work was to explore the creation of photo-atomic multi-group cross section libraries to be used with a software package DOCTORS (Discrete Ordinates Computed Tomography and Radiography Simulator). This software solves the linear Boltzmann equation using the discrete ordinates method. To create these libraries, NJOY2016 was used, creating both fine and broad energy multi-group cross section files. The cross section's accuracy was tested against an equivalent Monte Carlo simulation using MCNP6. Two simulation geometries were used. The first, a cylindrical water phantom with a single source projection placed in front, simulating an X-ray radiography. The second used the same water phantom with 16 cone beam sources placed evenly around the phantom to simulate a computed tomography (CT) scan. The accuracy of the fine energy multi-group cross sections when used in DOCTORS has been verified. The accuracy of the broad energy multigroup cross sections when used in DOCTORS shows that more work must be done before they can be used reliably. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

RADIO AND X-RAY SHOCKS IN CLUSTERS OF GALAXIES

Radio relics detected in the outskirts of galaxy clusters are thought to trace radio-emitting relativistic electrons accelerated at cosmological shocks. In this study, using the cosmological hydrodynamic simulation data for the large-scale structure formation and adopting a diffusive shock acceleration (DSA) model for the production of cosmic-ray (CR) electrons, we construct mock radio and X-ray maps of simulated galaxy clusters that are projected in the sky plane. Various properties of shocks and radio relics, including the shock Mach number, radio spectral index, and luminosity, are extracted from the synthetic maps and compared with observations. A substantial fraction of radio and X-ray shocks identified in these maps involve multiple shock surfaces along lines of sight (LOSs), and the morphology of shock distributions in the maps depends on the projection direction. Among multiple shocks in a given LOS, radio observations tend to pick up stronger shocks with flatter radio spectra, while X-ray observations preferentially select weaker shocks with larger kinetic energy flux. As a result, in some cases the shock Mach numbers and locations derived from radio and X-ray observations could differ from each other. We also find that the distributions of the spectral index and radio power of the synthetic radio relics are somewhat inconsistent with those of observed real relics; a bit more radio relics have been observed closer to the cluster core and with steeper spectral indices. We suggest that the inconsistency could be explained if very weak shocks with M{sub s} ≲ 2 accelerate CR electrons more efficiently, compared with the DSA model adopted here.

79 ASTRONOMY AND ASTROPHYSICS↗

Year One Summary of X-energy Pebble Fuel Development at ORNL

The Advanced Reactor Concepts X-energy (ARC-Xe) Pebble Fuel Development project at Oak Ridge National Laboratory (ORNL) has successfully completed its first year, having made excellent progress in accomplishing programmatic objectives. The primary focus of research at ORNL in support of X-energy has been the training of X-energy fuel fabrication engineers and the establishment of US pebble fuel production capabilities able to supply the Xe-100 pebble-bed reactor. These efforts have been strongly supported by particle fuel fabrication and characterization expertise present at ORNL from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Report: Understanding Functional Lyotropic Liquid Crystal Network Phase Self-Assembly and the Properties of Nanoconfined Water

Through the synergistic interplay of molecular dynamics (MD) simulations, chemical synthesis, and materials characterization by X-ray and neutron scattering techniques, this project investigated the phase behaviors of new classes of aqueous lyotropic liquid crystals (LLCs) and the properties of water nanoconfined within their pores. A portion of our studies focused on the synthesis of new classes of alkylsulfonic acid and alkylphosphonate amphiphiles, which were shown to undergo water-induced self-assembly to form a wide variety of nanostructured morphologies with unusually high degrees of long-range translational order observed by small- angle X-ray scattering (SAXS). Sample LLC morphologies that were observed include the lamellar (L!), tricontinuous double gyroid (G), hexagonally-packed cylinders (H), and low symmetry discontinuous micellar (I) Frank-Kasper phases. Since the G and H phases are the most promising for the development of selective ion transporting membranes for energy applications, we sought the characterize the structure and dynamics of water confined within the sub-3 nm pores of these LLCs using wide-angle neutron diffraction (WAND) and quasielastic neutron scattering (QENS) experiments performed at the Spallation Neutron Source at Oak Ridge National Laboratory. Using molecular dynamics (MD) simulations, we validated models for analyzing this QENS data to obtain water self-diffusion coefficients in LLC G and H phases of carboxylate and sulfonate surfactant LLCs as a function of the identities of their charge compensating counterions.

07 ISOTOPE AND RADIATION SOURCES↗

THE VLA-COSMOS SURVEY. IV. DEEP DATA AND JOINT CATALOG

In the context of the VLA-COSMOS Deep project, additional VLA A array observations at 1.4 GHz were obtained for the central degree of the COSMOS field and combined with the existing data from the VLA-COSMOS Large project. A newly constructed Deep mosaic with a resolution of 2.''5 was used to search for sources down to 4{sigma} with 1{sigma} {approx} 12 {mu}Jy beam{sup -1} in the central 50' x 50'. This new catalog is combined with the catalog from the Large project (obtained at 1.''5 x 1.''4 resolution) to construct a new Joint catalog. All sources listed in the new Joint catalog have peak flux densities of {>=}5{sigma} at 1.''5 and/or 2.''5 resolution to account for the fact that a significant fraction of sources at these low flux levels are expected to be slightly resolved at 1.''5 resolution. All properties listed in the Joint catalog, such as peak flux density, integrated flux density, and source size, are determined in the 2.''5 resolution Deep image. In addition, the Joint catalog contains 43 newly identified multi-component sources.

79 ASTRONOMY AND ASTROPHYSICS↗