Search NASA⌕ Search

SEARCH · Search NASA

Results for “Screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SSC: A Tool for Constructing Libraries for Systematic Screening of Conformers

Even a relatively small molecule with 10–20 atoms might have a few local minima, which correspond to different conformers. The number of local minima quickly increases with molecular size and the most common algorithms, driven by calculated forces, frequently identify a minimum, which is closest to the initial structure, rather than the most stable conformer. Here we discuss how to perform a systematic search of the conformational space for a chain-like molecule. Our approach is fully automated and a user has control which chemical bonds will be probed and with which increments. Moreover, whole fragments of the molecule, which are adjacent to each selected rotational bond, are rotated in a properly selected cylindrical coordinate system and unchemical hybridizations and some ‘‘clashes’’ between neighboring groups, which are common when standard Z-matrices are used, are avoided. A library of potentially relevant conformers is created with a tool, which we call SSC, denoting Systematic Screening of Conformers. Each member of the library is prescreened at a predefined level of theory and the most promising conformers are identified. Finally, they are further evaluated at a higher level of theory to identify the most stable structures and their physicochemical properties. As an example, we demonstrate the results of this approach for 2'-deoxycytidine.

43 PARTICLE ACCELERATORS↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Screening for High Conductivity/Low Viscosity Ionic Liquids Using Product Descriptors

We seek to optimize Ionic liquids (ILs) for application to redox flow batteries. As part of this effort, we have developed a computational method for suggesting ILs with high conductivity and low viscosity. Since ILs consist of cation-anion pairs, we consider a method for treating ILs as pairs using product descriptors for QSPRs, a concept borrowed from the prediction of protein-protein interactions in bioinformatics. We demonstrate the method by predicting electrical conductivity, viscosity, and melting point on a dataset taken from the ILThermo database on June 18th, 2014. The dataset consists of 4,329 measurements taken from 165 ILs made up of 72 cations and 34 anions. In conclusion, we benchmark our QSPRs on the known values in the dataset then extend our predictions to screen all 2,448 possible cation-anion pairs in the dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Magnetic Resonance ‐based fragment screen of the E3 ligase Fem‐1 homolog B

Abstract Targeted protein degradation using PROTACs (PROteolysis TArgeting Chimeras) has emerged as a transformative therapeutic strategy, largely relying on a small number of E3 ubiquitin ligases such as CRBN and VHL. However, resistance, toxicity, and poor oral bioavailability limit the utility of PROTACs and highlight the need to expand the E3 ligase toolbox. Fem‐1 homolog B (FEM1B) is a lesser‐known E3 ligase that offers a promising alternative due to its broad expression and ability to recognize diverse degron motifs. Here, we describe the development of a stable construct of FEM1B, the results of a protein‐observed NMR‐based fragment screen using this construct, and the X‐ray structures of some of the fragment hits when bound to the protein. From these results, new PROTACs utilizing FEM1B as the E3 ligase may be discovered, providing an alternative E3 ligase for targeted protein degradation.

Katinas, Jade M. [Department of Biochemistry Vande↗

Easy parallel screening of reagent stability, quality control, and metrology in solid phase peptide synthesis (SPPS) and peptide couplings for microarrays

Evaluating the stability of coupling reagents, quality control (QC), and surface functionalization metrology are all critical to the production of high quality peptide microarrays. We describe a broadly applicable screening technique for evaluating the fidelity of solid phase peptide synthesis (SPPS), the stability of activation/coupling reagents, and a microarray surface metrology tool. This technique was used to assess the stability of the activation reagent 1-{[1-(Cyano-2-ethoxy-2-oxo-ethylidenaminooxy)dimethylamino-morpholinomethylene]}methaneaminiumHexafluorophosphate (COMU) (Sigma-Aldrich, St. Louis, MO, USA) by SPPS of Leu-Enkephalin (YGGFL) or the coupling of commercially synthesized YGGFL peptides to (3-aminopropyl)triethyoxysilane-modified glass surfaces. Coupling efficiency was quantitated by fluorescence signaling based on immunoreactivity of the YGGFL motif. It was concluded that COMU solutions should be prepared fresh and used within 5 h when stored at ~23 °C and not beyond 24 h if stored refrigerated, both in closed containers. Caveats to gauging COMU stability by absorption spectroscopy are discussed. Commercial YGGFL peptides needed independent QC, due to immunoreactivity variations for the same sequence synthesized by different vendors. This technique is useful in evaluating the stability of other activation/coupling reagents besides COMU and as a metrology tool for SPPS and peptide microarrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Screen charge transfer by grounded tip on ferroelectric surfaces.

We have investigated polarization reversal and charge transfer effects by a grounded tip on 50 nm thick ferroelectric thin films using piezoelectric force microscopy and Kelvin force microscopy. We observed the polarization reversal in the center of written domains, and also identified another mechanism, which is the transfer of screen charges toward the grounded tip. In order to overcome these phenomena, we successfully applied a modified read/write scheme featuring a bias voltage.

36 MATERIALS SCIENCE↗

Quantum-Dot-Based Electrochemical Immunoassay for High-Throughput Screening of the Prostate-Specific Antigen

In this paper, we demonstrate an electrochemical high-throughput sensing platform for simple, sensitive detection of PSA based on QD labels. This sensing platform uses a microplate for immunoreactions and disposable screen-printed electrodes (SPE) for electrochemical stripping analysis of metal ions released from QD labels. With the 96-well microplate, capturing antibodies are conveniently immobilized to the well surface, and the process of immunoreaction is easily controlled. The formed sandwich complexes on the well surface are also easily isolated from reaction solutions. In particular, a microplate-based electrochemical assay can make it feasible to conduct a parallel analysis of several samples or multiple protein markers. This assay offers a number of advantages including (1) simplicity, cost-effectiveness, (2) high sensitivity, (3) capability to sense multiple samples or targets in parallel, and (4) a potentially portable device with an SPE array implanted in the microplate. This PSA assay is sensitive because it uses two amplification processes: (1) QDs as a label for enhancing electrical signal since secondary antibodies are linked to QDs that contain a large number of metal atoms and (2) there is inherent signal amplification for electrochemical stripping analysis—preconcentration of metal ion onto the electrode surface for amplifying electrical signals. Therefore, the high sensitivity of this method, stemming from dual signal amplification via QD labels and pre-concentration, allows low concentration levels to be detected while using small sample volumes. Thus, this QD-based electrochemical detection approach offers a simple, rapid, cost-effective, and high throughput assay of PSA.

59 BASIC BIOLOGICAL SCIENCES↗

Screening for Lipids From Marine Microalgae Using Nile Red

The fluorescent stain Nile Red has been used extensively for the quantification of lipids in phytoplankton, including microalgae, because it preferentially stains neutral lipids and it is economical and sensitive to use for screening purposes. Although its basic application has not changed for several decades, recent improvements have been made to improve its utility across applications. Here we describe additional refinements in its application and interpretation as a highthroughput method for the rapid quantification of neutral lipids in liquid cultures of marine phytoplankton. Specifically we address (1) interspecies comparisons, (2) fluorescence excitation and emission wavelengths, and (3) the time course of the Nile Red signal in the context of using bulk or cell-specific fluorescence to quantify neutral lipids oflive or preserved cells. Here, we show that with proper caution in its interpretation across species and physiological states the quantity of lipid in hundreds of small volume samples can be reliably assessed daily using a refined Nile Red protocol.

09 BIOMASS FUELS↗

Deformable Registration for Longitudinal Breast MRI Screening

MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T{sub 1}-weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that using the optimal registration parameter set, a registration accuracy (in mm) of 3.4 [1.8 6.8] was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct water decomposition on transition metal surfaces: Structural dependence and catalytic screening

Density functional theory calculations are used to investigate thermal water decomposition over the close-packed (111), stepped (211), and open (100) facets of transition metal surfaces. A descriptor-based approach is used to determine that the (211) facet leads to the highest possible rates. As a result, a range of 96 binary alloys were screened for their potential activity and a rate control analysis was performed to assess how the overall rate could be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated screening of functional atomic impurities in halide perovskites using high-throughput computations and machine learning

The pressing need for novel materials that can serve rising demands in solar cell and optoelectronic technologies makes the nexus of halide perovskites, high-throughput computations, and machine learning, very promising. Ever increasing amounts of data on the structure, fundamental properties, and device performance of halide perovskites provide opportunities for learning chemical rules and design principles that make these materials attractive, and applying them across wide chemical spaces. In this work, we show that impurity properties of halide perovskites computed using density functional theory (DFT) can be combined with machine learning (ML) to deliver predictive models and quick identification of optoelectronically active impurity atoms. Our computation lead to the largest reported dataset of the formation energies and charge transition levels of Pb-site impurities in methylammonium lead halide (MAPbX 3 ) perovskites. Descriptors are defined to uniquely represent any impurity atom in any MAPbX 3 compound and mapped to the computed impurity properties using regression techniques such as Gaussian process regression, neural networks, and random forests. We use the best optimized predictive models to make predictions for hundreds of impurities across 9 MAPbX 3 compounds and create lists of dominating impurities, that is, impurities that can shift the equilibrium Fermi level in the perovskite as determined by native point defects. Finally, this accelerated screening powered by computations and machine learning can guide the identification of problematic impurities that may cause undesired recombination of charge carriers, as well as impurities that can be deliberately introduced to tune the perovskite conductivity and resulting photovoltaic absorption.

36 MATERIALS SCIENCE↗

Voltammetric determination of vitamin B{sub 6} (pyridoxine) at a graphite screen-printed electrode modified with graphene oxide/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite

The preparation and study of electrochemical properties of a graphite screen-printed electrode (SPE) modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} (GO is graphene oxide) nanocomposites are described. The morphologies of the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposites were examined by scanning electron microscopy. The electrochemical oxidation of vitamin B{sub 6} (pyridoxine) on SPE modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite was investigated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. Under optimum conditions (pH 7.0), the vitamin B{sub 6} oxidation at the surface of the modified SPE occurs at a potential about 190 mV less positive than that at the unmodified SPE. A linear voltammetric response for vitamin B{sub 6} was obtained in the concentration range 1.0•10 {sup 6}—9.0•10 {sup 4} mol L{sup –1} with a detection limit of 5.2•10 {sup 7} mol L{sup –1} using differential pulse voltammetry. The developed sensor was also successfully applied for determination of trace level of vitamin B{sub 6} in both the standard vitamin B{sub 6} sample and biological samples (urine).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar Models with Dynamic Screening and Early Mass Loss Tested by Helioseismic, Astrophysical, and Planetary Constraints

The faint young Sun paradox remains an open question. Presented here is one possible solution to this apparent inconsistency, a more massive early Sun. Based on the conditions on early Earth and Mars, a luminosity constraint is set as a function of mass. For this, we examine helioseismic constraints of these alternative mass-losing models. Additionally, we explore a dynamic electron screening correction in an effort to improve helioseismic agreement in the core of the early mass-losing model.

79 ASTRONOMY AND ASTROPHYSICS↗

Stacking Fault Energy Based Alloy Screening for Hydrogen Compatibility

The selection of austenitic stainless steels for hydrogen service is challenging since there are few intrinsic metrics that relate alloy composition to hydrogen degradation. One such metric, explored here, is intrinsic stacking fault energy. Stacking fault energy has an influence on the character and structure of dislocations and on the formation of secondary crystalline phases created during mechanical deformation in austenitic alloys. In this work, a data-driven model for the intrinsic stacking fault energy of common austenitic stainless steel alloys is applied to compare the relative degradation of tensile performance in the presence of hydrogen. A transition in the tensile reduction of area of both 300-series and manganese stabilized stainless steels is observed at a calculated stacking fault energy of approximately 43 mJ m -2 , below which pronounced hydrogen degradation on tensile ductility is observed. The model is also applied to suggest alloying strategies for low nickel austenitic stainless steels for hydrogen service. Lastly, through this investigation, we find that calculated intrinsic stacking fault energy is a high-throughput screening metric that enables the ranking of the performance of a diverse range of austenitic stainless steel compositions, as well as the identification of new alloys, with regard to hydrogen compatibility.

08 HYDROGEN↗

Sputter-Coated Metal Screening for Small Molecule Analysis and High-Spatial Resolution Imaging in Laser Desorption Ionization Mass Spectrometry

Nanoparticles are efficient matrices in laser desorption/ionization (LDI) mass spectrometry (MS), especially for the profiling or imaging of small molecules. Recently, solvent-free physical vapor desorption (PVD), or sputter coating, was adopted as a homogenous method to rapidly apply metal nanoparticles (NPs) in situ to samples prior to LDI MS or MS imaging analysis. However, there has been no systematic study comparing different metal targets for the analysis of a variety of small molecule metabolites. Here, we present a screening and optimization of various sputter-coated metals, including Ag, Au, Cu, Pt, Ni, and Ti, for LDI analysis of small molecules in both positive and negative ion modes. Optimized sputter coating is then applied to high-spatial resolution LDI mass spectrometry imaging (MSI) of maize root and seed cross-sections. Noble metals, Ag, Au, and Pt, are found to be much more efficient than transition metals and organic matrices for most small metabolites. Sputter-coated metals are efficient for neutral lipids, such as triacylglycerols and diacylglycerols, but are very inefficient for most phospholipids. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MALDI-MS screening of microbial colonies with isomer resolution to select fatty acid desaturase variants

Creating controlled lipid unsaturation locations in oleochemicals can be a key to many bioengineered products. However, evaluating the effects of modifications to the acyl-ACP desaturase on lipid unsaturation is not currently amenable to high-throughput assays, limiting the scale of redesign efforts to <200 variants. Here, we report a rapid MS assay for profiling the positions of double bonds on membrane lipids produced by Escherichia coli colonies after treatment with ozone gas. By MS measurement of the ozonolysis products of Δ6 and Δ8 isomers of membrane lipids from colonies expressing recombinant Thunbergia alata desaturase, we screened a randomly mutagenized library of the desaturase gene at 5 s per sample. Two variants with altered regiospecificity were isolated, indicated by an increase in 16:1 Δ8 proportion. We also demonstrated the ability of these desaturase variants to influence the membrane composition and fatty acid distribution of E. coli strains deficient in the native acyl-ACP desaturase gene, fabA. Lastly, we used the fabA deficient chassis to concomitantly express a non-native acyl- ACP desaturase and a medium-chain thioesterase from Umbellularia californica, demonstrating production of only saturated free fatty acids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DuctGPT: A Generative Transformer for Forward Screening of Ductile Refractory Multi-Principal Element Alloys

Designing ductile materials for extreme environments such as fusion reactors requires a deep understanding of the complex interplay between electronic structure, mechanical stability, and wide compositional space. Here, in this work, we introduce DuctGPT, a physics-informed, GPT-powered machine learning platform that enables rapid and accurate prediction of ductility across a wide range of refractory multi-principal element alloys (MPEAs). Trained on both experimental and high-fidelity computational data, DuctGPT integrates descriptors such as density of states at the Fermi level, elastic constants, and valence electron concentration to capture the fundamental mechanisms governing ductile versus brittle behavior. Using this framework, we screen over 1000 compositions in of body-centered cubic (BCC) MPEAs, including two new alloy classes, i.e., NbTa-rich (NbTa $>$ 50 at.%) NbTa-Ti-V and W-rich ($>$ 50 at.%) W-Ti-V MPEAs, to rapidly identify promising alloy compositions with enhanced ductility. Validation against experimental data confirms the model's ability to predict ductility with high fidelity and low uncertainty. By leveraging conversational AI and robust physical modeling, DuctGPT provides a blueprint for the next generation of alloy design assistants, enabling human-AI collaboration in the accelerated discovery of ductile, high-performance materials for fusion, aerospace, and advanced manufacturing.

AI/ML↗

Screening-Constant-by-Unit-Nuclear-Charge method investigations of high lying ({sup 1}D{sub 2},{sup 1}S{sub 0}) ns, nd Rydberg series in the photoionization spectra of the halogen-like ion Kr{sup +}

Energy positions and quantum defects of the 4s{sup 2}4p{sup 4} ({sup 1}D{sub 2},{sup 1}S{sub 0}) ns, nd Rydberg series originating from the 4s{sup 2}4p{sup 52}P{sub 3/2}{sup ∘} ground state and from the 4s{sup 2}4p{sup 52}P{sub 1/2}{sup ∘} metastable state of Kr{sup +} are reported. Calculations are performed using the Screening Constant by Unit Nuclear Charge (SCUNC) method. The results obtained are in suitable agreement with recent experimental data from the combined ASTRID merged-beam set up and Fourier Transform Ion Cyclotron Resonance device (Bizau et al., 2011), ALS measurements (Hinojosa et al., 2012), and multi-channel R-matrix eigenphase derivative calculations (McLaughlin and Balance, 2012). In addition, analysis of the 4s{sup 2}4p{sup 4}({sup 1}D{sub 2})nd and the 4s{sup 2}4p{sup 4}({sup 1}S{sub 0})nd resonances is given via the SCUNC procedure. The excellent results obtained from our work point out that the SCUNC formalism may be used to confirm the results of the analysis from the standard quantum-defect expansion formulas. Eventual errors occurring in the analysis can then be automatically detected and corrected via the SCUNC procedure.

74 ATOMIC AND MOLECULAR PHYSICS↗