Instrument Front-Ends at Fermilab During Run II

The optimization of an accelerator relies on the ability to monitor the behavior of the beam in an intelligent and timely fashion. The use of processor-driven front-ends allowed for the deployment of smart systems in the field for improved data collection and analysis during Run II. This paper describes the implementation of the two main systems used: National Instruments LabVIEW running on PCs, and WindRiver's VxWorks real-time operating system running in a VME crate processor.

43 PARTICLE ACCELERATORS↗

VAC: A Software Approach to Resilient SCADA Automation

To better secure critical infrastructure, especially power systems, this paper introduces a virtual SCADA automation controller. The automation controller is a gateway into a power subsystem, making it a valuable target for cyber-attacks that could cut it off from the control center and cause a loss of view and control. To prevent this, the Virtual Automation Controller (VAC) is a backup device that mirrors the capabilities of the physical controller. It can communicate via Modbus and DNP3 and is containerized so it can be deployed on a variety of platforms. Furthermore, it utilizes software-defined networking to quickly disconnect a failed automation controller and preserve its state for forensics. The VAC gives system operators time to replace the failed controller and prevents dangerous and costly damage to power systems. The VAC is compared against the SEL 3505-3 RTAC and shown to have the necessary features to act as a failover controller.

Johnson, Jordan↗

Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibration service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These different methods of calibration demonstrated +1% to +2% differences in solar irradiance measurement. Analyzing these differences will ultimately help determine the uncertainty of the field radiometer data and guide the development of a consensus standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainty will allow more accurate prediction of solar output and improve the bankability of solar projects.

14 SOLAR ENERGY↗

Dynamic Undervolting to Improve Energy Efficiency on Multicore X86 CPUs

Chip manufacturers introduce redundancy at various levels of CPU design to guarantee correct operation, even for worst-case combinations of non-idealities in process variation and system operating conditions. This redundancy is implemented partly in the form of voltage margins. However, for a wide range of real-world execution scenarios these margins are excessive and merely translate to increased power consumption, hindering the effort towards higher-energy efficiency in both HPC and general purpose computing. Our study on the x86-64 Haswell and Skylake multicore microarchitectures reveals-wide voltage margins, which vary across different microarchitectures, different chip parts of the same microarchitecture, and across different workloads. We find that it is necessary to quantify-voltage margins using multi-threaded and multi-instance workloads, as characterization with single-threaded and single-instance workloads that do not stress the CPU to its full capacity typically identifies overly optimistic margins that lead to errors when applied in realistic program execution scenarios. In addition, we introduce, deploy and evaluate a run-time governor that dynamically reduces the supply voltage of modern multicore x86-64 CPUs. Our governor employs a model that takes as input a set of performance metrics which are directly measurable via performance monitoring counters and have high predictive value for the minimum tolerable supply voltage (V min ), to predict and apply the appropriate reduction for the workload at hand. Compared with the conventional DVFS governor, our approach in this study achieves up to 42 percent energy savings for the Skylake family and 34 percent for the Haswell family for complex, real-world applications.

97 MATHEMATICS AND COMPUTING↗

Efficient Image Reconstruction Method for a Millimeter-wave Shoe Scanner

The Pacific Northwest National Laboratory (PNNL) has recently developed an active 3D microwave/millimeter-wave shoe scanner. This system is designed to detect threats concealed within the soles of common footwear. The system operates over the 10-40 GHz frequency range for excellent penetration of common materials. The system presents several challenges for efficient image reconstruction, including the thick dielectric window, multi-row linear arrays, and focusing close to the antenna elements. In this paper, an efficient back-projection reconstruction algorithm is presented that overcomes these challenges. Experimental imaging results are shown that demonstrate high-resolution imaging performance for this new scanner.

Sheen, David M.↗

Report on the deployment of the National Geothermal Data System 2.0

This reports includes a video description of recent upgrades and changes to the National Geothermal Data System (geothermaldata.org) and a text report of its relevant security upgrades. Improvements include a new operating system, implementation of HTTPS, implementation of a standard firewall, PostgreSQL upgrades, an ESRI ArcGIS server, new registration policies, and a non-public API.

15 GEOTHERMAL ENERGY↗

Performance Potential of Mixed Data Management Modes for Heterogeneous Memory Systems

Many high-performance systems now include different types of memory devices within the same compute platform to meet strict performance and cost constraints. Such heterogeneous memory systems often include an upper-level tier with better performance, but limited capacity, and lower-level tiers with higher capacity, but less bandwidth and longer latencies for reads and writes. To utilize the different memory layers efficiently, current systems rely on hardware-directed, memory -side caching or they provide facilities in the operating system (OS) that allow applications to make their own data-tier assignments. Since these data management options each come with their own set of trade-offs, many systems also include mixed data management configurations that allow applications to employ hardware- and software-directed management simultaneously, but for different portions of their address space. Despite the opportunity to address limitations of stand-alone data management options, such mixed management modes are under-utilized in practice, and have not been evaluated in prior studies of complex memory hardware. In this work, we develop custom program profiling, configurations, and policies to study the potential of mixed data management modes to outperform hardware- or software-based management schemes alone. Our experiments, conducted on an Intel ® Knights Landing platform with high-bandwidth memory, demonstrate that the mixed data management mode achieves the same or better performance than the best stand-alone option for five memory intensive benchmark applications (run separately and in isolation), resulting in an average speedup compared to the best stand-alone policy of over 10 %, on average.

Effler, Chad↗

Computational analysis of deployable wind turbine systems in defense operational energy applications.

The U.S. military has been exploring pathways to reduce the logistical burden of fuel on virtually all their missions globally. Energy harvesting of local resources such as wind and solar can help increase the resilience and operational effectiveness of military units, especially at the most forward operating bases where the fuel logistics are most challenging. This report considers the potential benefits of wind energy provided by deployable wind turbines as measured by a reduction in fuel consumption and supply convoys to a hypothetical network of Army Infantry Brigade Combat Team bases. Two modeling and simulation tools are used to represent the bases and their operations and quantify the impacts of system design variables that include wind turbine technologies, battery storage, number of turbines, and wind resource quality. The System of Systems Analysis Toolkit Joint Operational Energy Model serves as a baseline scenario for comparison. The Hybrid Optimization of Multiple Energy Resources simulation tool is used to optimize a single base within the larger Joint Operational Energy Model. The results of both tools show that wind turbines can provide significant benefits to contingency bases in terms of reduced fuel use and number of convoy trips to resupply the base. The match between the turbine design and wind resource, which is statistically low across most of the global land area, is a critical design consideration. The addition of battery storage can enhance the benefits of wind turbines, especially in systems with more wind turbines and higher wind resources. Wind turbines may also provide additional benefits to other metrics such as resilience that may be important but not fully considered in the current analysis. ACKNOWLEDGEMENTS The authors would like to thank the following individuals for their helpful support, feedback and review to improve this report: U.S. Department of Energy Wind Energy Technologies Office, Patrick Gilman and Bret Barker; Idaho National Laboratory, Jake Gentle and Bradley Whipple; The National Renewable Energy Laboratory, Robert Preus and Tony Jimenez; Sandia National Laboratories, Alan Nanco, Dennis Anderson, and Hai Le. In addition, numerous discussions with military and industry stakeholders over the year were invaluable in focusing the efforts represented in this report.

17 WIND ENERGY↗

Hydrogen Energy Storage (HES) and Power-to-Gas Economic Analysis; NREL (National Renewable Energy Laboratory)

This presentation summarizes opportunities for hydrogen energy storage and power-to-gas and presents the results of a market analysis performed by the National Renewable Energy Laboratory to quantify the value of energy storage. Hydrogen energy storage and power-to-gas systems have the ability to integrate multiple energy sectors including electricity, transportation, and industrial. On account of the flexibility of hydrogen systems, there are a variety of potential system configurations. Each configuration will provide different value to the owner, customers and grid system operator. This presentation provides an economic comparison of hydrogen storage, power-to-gas and conventional storage systems. The total cost is compared to the revenue with participation in a variety of markets to assess the economic competitiveness. It is found that the sale of hydrogen for transportation or industrial use greatly increases competitiveness. Electrolyzers operating as demand response devices (i.e., selling hydrogen and grid services) are economically competitive, while hydrogen storage that inputs electricity and outputs only electricity have an unfavorable business case. Additionally, tighter integration with the grid provides greater revenue (e.g., energy, ancillary service and capacity markets are explored). Lastly, additional hours of storage capacity is not necessarily more competitive in current energy and ancillary service markets and electricity markets will require new mechanisms to appropriately compensate long duration storage devices.

30 DIRECT ENERGY CONVERSION↗

Particle Number Concentrations for HI-SCALE Field Campaign Report

In support of the Holistic Interactions of Shallow Clouds, Aerosols, and Ecosystems (HI-SCALE) project to study new particle formation in the atmosphere, a pair of custom water condensation particle counters were provided to the second intensive field campaign, from mid-August through mid-September 2017, at the U.S. Department of Energy Southern Great Plains Atmospheric Radiation Measurement (ARM) Climate Research Facility observatory. These custom instruments were developed by Aerosol Dynamics, Inc. (Hering et al. 2017) to detect particles into the nanometer size range. Referred to as “versatile water condensation particle counter (vWCPC)”, they are water-based, laminar-flow condensational growth instruments whose lower particle size threshold can be set based on user-selected operating temperatures. For HI-SCALE, the vWCPCs were configured to measure airborne particle number concentrations in the size range from approximately 2nm to 2μm. Both were installed in the particle sizing system operated by Chongai Kuang of Brookhaven National Laboratory (BNL). One of these was operated in parallel to a TSI Model 3776, upstream of the mobility particle sizing system, to measure total ambient particle concentrations. The airborne particle concentration data from this “total particle number vWCPC” (Ntot-vWCPC) system has been reported to the ARM database. The data are reported with one-second resolution. The second vWCPC was operated in parallel with the BNL diethylene glycol instrument to count particles downstream of a separate differential mobility size analyzer. Data from this “DMA-vWCPC” system was logged by BNL, and will eventually be provided by that laboratory.

HI-SCALE, aerosol particle number concentration, v↗

Carolina Offshore Wind Integration Case Study: Phases I and II Final Technical Report

Duke Energy performed a phase 1 study to assess the impact of offshore wind development in the waters off the coasts of North Carolina and South Carolina. The study analyzed the impacts to the Duke Energy Carolinas electric power system of multiple wind deployment scenarios. Focusing on an integrated utility system in the Carolinas provided a unique opportunity to assess the impacts of offshore wind development in a region that has received less attention regarding renewables than others in the US. North Carolina is the only state in the Southeastern United States that currently has a renewable portfolio standard (RPS) which requires that 12.5% of the state’s total energy requirements be met with renewable resources by 2021. 12.5% of the state’s total energy requirements in 2021 equates to approximately 17,000 GWH of energy needed from renewable resources. Wind resources represent one of the ways to potentially meet this requirement. The study builds upon and augments ongoing work, including a study by UNC to identify potential wind development sites and the analysis of impacts to the regional transmission system performed by the NCTPC, an Order 890 planning entity of which DEC is a member. Furthermore, because the region does not have an independent system operator (ISO) or regional transmission organization (RTO), the study will provide additional information unique to non-RTO/ISO systems. The Phase 2 study builds on the results of Phase 1 and investigates the dynamic stability of the electrical network in Task 4, the operating characteristics of the wind turbines as they impact operating reserve requirements of the DEC utility in Task 5, and the production cost of integrating the offshore wind resources into the DEC generation fleet making comparisons to future planned operation without the addition of the wind resources in Task 6.

17 WIND ENERGY↗

Robust Distribution System Load Restoration With Time-Dependent Cold Load Pickup

Service restoration is one of the critical functions to enable the future self-healing distribution system. To restore the distribution system in a timely and reliable manner, the realistic system operating conditions need to be accurately characterized. Here, two main factors that have great impacts on distribution system restoration (DSR) in practice are investigated. First, cold load pickup (CLPU), generally caused by thermostatically controlled loads (TCLs), is a common phenomenon after an outage and shaped by the outage duration. However, the time-dependent behaviors of CLPU are rarely considered in literature. In this paper, the operating state evolution of TCLs after an outage is analyzed to characterize time-dependent CLPU. And the time-dependent CLPU is analytically embedded in DSR to accurately represent the actual behaviors of the restored loads. Second, it is difficult to predict loads that fluctuate during DSR due to the lack of real-time measurement data. Accordingly, a robust DSR based on the information gap decision theory (IGDT) is proposed to address this challenge, fully considering the uncertainty of CLPU. The proposed models are tested in IEEE 13-node and 123-node test feeders. Simulation results demonstrate that the time-dependent CLPU model and the uncertainty modeling of CLPU can accurately capture the actual behaviors of loads with TCLs after an outage, which greatly improves DSR decisions in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Development of Long-Pulse Heating and Current Drive Actuators and Operational Techniques Compatible with a High-Z Divertor and First Wall

Accurate measurement of the edge electron density profile is essential to optimizing antenna coupling and assessment of impurity contamination in studying long-pulse plasma heating and current drive in fusion devices. Measurement of the edge density profile has been demonstrated on the US fusion devices such as C-Mod, DIII-D, and TFTR amongst many devices, and has been used for RF loading and impurity modeling calculations for many years. University of Science and Technology of China (USTC) has recently installed a density profile reflectometer system on the EAST fusion device at the Institute of Plasma Physics, Chinese Academy of Sciences in China based on the University of California Los Angeles (UCLA)-designed reflectometer system on the DIII-D fusion device at General Atomics Company in San Diego, California. UCLA has been working with USTC to optimize the existing microwave antenna, waveguide system, microwave electronics, and data analysis to produce reliable edge density profiles. During the past budget year, progress has been made in all three major areas: effort to achieve reliable system operations under various EAST operational conditions, effort to optimize system performance, and effort to provide quality density profiles into EAST’s database routinely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗