Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Steady Deflagration of PBX-9501 Within a Copper Cylinder

A copper cylinder cook-off experiment has been designed to cause steady deflagration in PBX-9501 explosive material. The design is documented and preliminary copper expansion results are presented for steady deflagration with a reaction speed of 1092 +/- 24 m/s. The expansion of reaction products from the detonation of an explosive is something that is well understood, and reasonably simulated using documented equations of state (EOS) for many explosives of interest. These EOS were historically measured using a 'standard' copper cylinder test design; this design comprised an annealed, oxygen-free high conductivity (OFHC) copper tube filled with explosive material and detonated from one end. Expansion of the copper wall was measured as a function of time using either a streak camera (for classic testing), or more recently using laser velocimetry techniques. Expansion data were then used to derive the EOS in various preferred forms - which are not discussed here for the sake of brevity. When an explosive deflagrates rather than detonating, simulation becomes more difficult. Reaction products are released on a slower time scale, and the reactions are much more affected by the geometry and local temperature within the reaction environment. It is assumed that the standard, documented EOS will no longer apply. In an effort to establish a first order approximation of deflagration product behavior, a cook-off test has been designed to cause steady deflagration in PBX-9501 explosive material, and to record the copper expansion profile as a function of time during this test. The purpose of the current paper is to document the initial test design and report some preliminary results. A proposal for modification of the design is also presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing for Lorentz Violation: Constraints on Standard-Model-Extension Parameters via Lunar Laser Ranging

We present constraints on violations of Lorentz invariance based on archival lunar laser-ranging (LLR) data. LLR measures the Earth-Moon separation by timing the round-trip travel of light between the two bodies and is currently accurate to the equivalent of a few centimeters (parts in 10{sup 11} of the total distance). By analyzing this LLR data under the standard-model extension (SME) framework, we derived six observational constraints on dimensionless SME parameters that describe potential Lorentz violation. We found no evidence for Lorentz violation at the 10{sup -6} to 10{sup -11} level in these parameters. This work constitutes the first LLR constraints on SME parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Precision Measurements of Tau Lepton Decays

Using data collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a centre-of-mass energy near 10.58 GeV, the branching fractions B(τ - → π - π - π + ντ) =(8.83±0.01±0.13)%, B(τ - → K - π - π + ντ) =(0.273± 0.002 ± 0.009)%, B(τ - → K - π - K+ντ) =(0.1346 ± 0.0010 ± 0.0036)%, and B(τ - → K - K - K+ντ) =(1.58 ± 0.13 ± 0.12) × 10 -5 are measured where the uncertainties are statistical and systematic, respectively. The invariant mass distribution for the τ - → π - π - π+ντ , τ - → K - π - π+ντ , τ - → K - π - K+ντ and τ - → K - K - K+ντ decays are unfolded to correct for detector effects. A measurement of B(τ - → φπ - ντ ) =(3.42±0.55±0.25)×10 -5 , a measurement of B(τ - → φK - ντ) =(3.39±0.20±0.28)× 10 -5 and an upper limit on B(τ - → K - K - K+ντ [ex.φ]) ≤ 2.5 × 10 -6 @90%CL are determined from a binned maximum likelihood fit of the τ - → K - π - K+ντ and τ - → K - K - K+ντ K+K - invariant mass distributions. The branching ratio B(τ - →K - ν τ )/ B(τ - →π - ν τ ) is measured to be (6.531±0.056±0.093)×10 -2 from which |Vus| is determined to be 0.2255 ± 0.0023. The branching ratio B(τ - →μ - ν τ $\bar{v}$ μ )/ B(τ - →e - ν τ $\bar{v}$ e ) =(9.796 ± 0.016 ± 0.035) × 10 -1 is measured enabling a precision test of the Standard Model assumption of charged current lepton universality, gμ ge =1.0036 ± 0.0020. The branching ratios B(τ - →K - ν τ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(3.882 ± 0.032 ± 0.057) × 10 -2 , and B(τ - →π - ντ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(5.945 ± 0.014 ± 0.061) × 10 -1 are measured which provide additional tests of charged current lepton universality, g τ /g μ π = 0.9856 ± 0.0057 and g τ /g μ K = 0.9827 ± 0.0086 which can be combined to give g τ /g μ π/K = 0.9850 ± 0.0054 . Any deviation of these measurements from the expected Standard Model values would be an indication of new physics.

43 PARTICLE ACCELERATORS↗

Bounds on Neutrino Non-Standard Interactions

We review the present model independent bounds on neutrino non-standard interactions both at neutrino production and detection and in its interactions with matter. For matter non-standard interactions the direct bounds are rather weak. However, matter non-standard interactions are related by gauge invariance to the production and detection ones as well as to flavour changing processes involving charged leptons. Taking into account these relations much stronger bounds of at least O(10{sup -2}) can be derived unless significant fine tunings are implemented. Testing non-standard interactions at this level at future neutrino oscillation facilities is challenging but still feasible at very ambitious proposals such as the Neutrino Factory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the Drying of a Mock Used Fuel Assembly with COBRA-SFS Cycle-4 - 18597

The processing and storage of nuclear fuel is an ever increasingly pressing issue. Around 70,000 tons of used fuel are currently in either dry or wet storage on site at nuclear power plants or at specified spent fuel storage facilities. Additionally, about 2,000 tons are added to that sum each year. To promote retrievability, limit degradation in the canister, and reduce potential for hydrogen generation, spent fuel that is initially in wet storage must be dried before moving to dry cask storage. Therefore, this research seeks to use a mock used fuel storage cask to replicate the conditions in the industry during the drying process of fuel being moved from storage pools. To simulate this, a mock storage cask has been constructed to closely resemble those used in industry such that any areas that tend to retain water are replicated effectively. It is able to hold one mock used fuel assembly. The assembly used is an AREVA 10A 10 x 10 assembly with 78 rods filled with depleted uranium, 12 heater rods to simulate decay heat, a 3 x 3 BWR water channel, and one interchangeable rod position for tests such as a simulated failed fuel rod, BWR water rod, and PWR guide tube tests. The industry standard procedure is used in drying the assembly which involves stepping the system pressure down and holding for certain periods until reaching 3 torr and holding for 30 minutes. This is believed to sufficiently dry the assembly. The goal is to record data throughout these tests that can provide the industry with a greater understanding of how well the process works. This data will also be used to develop and validate a computer model of the drying process. Mechanistic models are currently under development. Reduced order models are being investigated for incorporation into current related engineering codes such as COBRA-SFS. COBRA-SFS is a member of the COBRA family of codes which is mainly used in the evaluation of thermal hydraulic systems containing spent nuclear fuel. However, it does not currently have the capability to account for processes such as evaporation encountered during drying operations. Therefore, those physical models are to be added to the source code. At present a model of the experiment has been created using the COBRA-SFS Cycle-4 code. A number of steady state models along with transient models have been developed and presented. Each of these yield valuable results for comparison with the experiments conducted. In addition to comparison with experimental results, the data collected from COBRA-SFS is compared with that which has been generated from other computer models which utilize computational fluid dynamics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Superheater Corrosion In Biomass Boilers: Today's Science and Technology

This report broadens a previous review of published literature on corrosion of recovery boiler superheater tube materials to consider the performance of candidate materials at temperatures near the deposit melting temperature in advanced boilers firing coal, wood-based fuels, and waste materials as well as in gas turbine environments. Discussions of corrosion mechanisms focus on the reactions in fly ash deposits and combustion gases that can give corrosive materials access to the surface of a superheater tube. Setting the steam temperature of a biomass boiler is a compromise between wasting fuel energy, risking pluggage that will shut the unit down, and creating conditions that will cause rapid corrosion on the superheater tubes and replacement expenses. The most important corrosive species in biomass superheater corrosion are chlorine compounds and the most corrosion resistant alloys are typically FeCrNi alloys containing 20-28% Cr. Although most of these materials contain many other additional additions, there is no coherent theory of the alloying required to resist the combination of high temperature salt deposits and flue gases that are found in biomass boiler superheaters that may cause degradation of superheater tubes. After depletion of chromium by chromate formation or chromic acid volatilization exceeds a critical amount, the protective scale gives way to a thick layer of Fe 2 O 3 over an unprotective (FeCrNi) 3 O 4 spinel. This oxide is not protective and can be penetrated by chlorine species that cause further acceleration of the corrosion rate by a mechanism called active oxidation. Active oxidation, cited as the cause of most biomass superheater corrosion under chloride ash deposits, does not occur in the absence of these alkali salts when the chloride is present as HCl gas. Although a deposit is more corrosive at temperatures where it is molten than at temperatures where it is frozen, increasing superheater tube temperatures through the measured first melting point of fly ash deposits does not necessarily produce a step increase in corrosion rate. Corrosion rate typically accelerates at temperatures below the first melting temperature and mixed deposits may have a broad melting temperature range. Although the environment at a superheater tube surface is initially that of the ash deposits, this chemistry typically changes as the deposits mature. The corrosion rate is controlled by the environment and temperature at the tube surface, which can only be measured indirectly. Some results are counter-intuitive. Two boiler manufacturers and a consortium have developed models to predict fouling and corrosion in biomass boilers in order to specify tube materials for particular operating conditions. It would be very useful to compare the predictions of these models regarding corrosion rates and recommended alloys in the boiler environments where field tests will be performed in the current program. Manufacturers of biomass boilers have concluded that it is more cost-effective to restrict steam temperatures, to co-fire biofuels with high sulfur fuels and/or to use fuel additives rather than try to increase fuel efficiency by operating with superheater tube temperatures above melting temperature of fly ash deposits. Similar strategies have been developed for coal fired and waste-fired boilers. Additives are primarily used to replace alkali metal chloride deposits with higher melting temperature and less corrosive alkali metal sulfate or alkali aluminum silicate deposits. Design modifications that have been shown to control superheater corrosion include adding a radiant pass (empty chamber) between the furnace and the superheater, installing cool tubes immediately upstream of the superheater to trap high chloride deposits, designing superheater banks for quick replacement, using an external superheater that burns a less corrosive biomass fuel, moving circulating fluidized bed (CFB) superheaters from the convective pass into the hot recirculated fluidizing medium and adding an insulating layer to superheater tubes to raise their surface temperature above the dew point temperature of alkali chlorides. These design changes offer advantages but introduce other challenges. For example, operating with superheater temperatures above the dew point of alkali chlorides could require the use of creep-resistant tube alloys and doesn't eliminate chloride corrosion. Improved test methods that can be applied within this project include automated dimensional metrology to make a statistical analysis of depth of penetration and corrosion product thickness, and simultaneous thermal analysis measurements to quantify the melting of complex ashes and avoid the unreliability of the standard ash fusion test. Other important developments in testing include the installation of individually-temperature-controlled superheater loops for corrosion testing in operating boilers and temperature gradient testing.

09 BIOMASS FUELS↗

Studies of the weak interaction in atomic systems: towards measurements of atomic parity non-conservation in francium

Abstract Tests of the standard model of particle physics should be carried out over the widest possible range of energies. Here we present our plans and progress for an atomic parity non-conservation experiment using the heaviest alkali, francium ( Z = 87), which has no stable isotope. Low-energy tests of this kind have sensitivity complementary to higher energy searches, e.g. at the large hadron collider.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scintilla European project, the successful research results

The Scintilla FP7 project is ended in December 2014, the fruitful results of 3 years development and tests will be presented. SCINTILLA offers the capacity to finding a reliable alternative to Helium-3 based detection systems since the gas which is predominantly used in nuclear safeguards and security applications has now become very expensive, rare and nearly unavailable. SCINTILLA benchmarks results are based on international standards. Radiation Portal tests were carried out at the Joint Research Centre (JRC) in Ispra (Italy). The scintilla project addresses few mains issues. The first is to develop neutron detectors for Radiation Portal Monitor (RPM) and the second is the need of new wearable integrated solutions for Spectrometric Personal Radiation Monitor (SPRM). The partners which provide technical systems of the scintilla project are INFN-ANSALDO, CEA, SYMETRICA and SAPHYMO. For RPM, the objective is to find reliable alternatives to Helium-3 historical neutron detector and provide technical solutions which cope with tests for reliable mobile and cost effective. For Spectrometric Personal Radiation Monitor (SPRM), SCINTILLA is innovating in technology areas that offer complementary capabilities for detecting and identifying gamma, Two CZT (Cadmium Zinc Telluride) addressing contexts of used by first responder technologies, one is a wearable detector and the second is a gamma camera complemented by advanced image processing technologies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of meteorological measurements from sparse and dense surface observational networks in the U.S. southern Great Plains.

The primary objective of this study was to analyze the spatial variability of temperature and relative humidity across Kansas (KS) and Oklahoma (OK) for sparse and dense networks by comparing data from (1) the Surface Meteorological Observing System (SMOS) installations at the Atmospheric Radiation Measurement (ARM; Peppler et al. 2007) Program's Southern Great Plains site and (2) the Oklahoma Mesonet (OKM; McPherson et al. 2007). Given the wealth of observations available from these networks, this study provided the unique opportunity to determine, within a quantifiable statistical limit, an optimal distance between stations deployed for observation of the climatological values of temperature and relative humidity. Average distances between a given station and its closest neighboring station for the ARM SMOS ({approx} 70 km) and the OKM ({approx} 30 km; Brotzge and Richardson 2003) networks provided an excellent framework for comparisons of sparse and dense observations (Figure 1). This study further lays groundwork for a future investigation to determine the necessary spacing between observations for initialization of gridded numerical models. The spatial variability of temperature and relative humidity was examined over KS and OK by comparing observations between station pairs located in three primary domains: (1) a sparse domain in KS, consisting only of ARM SMOS stations; (2) a dense domain centered in northern OK, consisting of both ARM SMOS and OKM stations; and (3) a dense domain centered in central OK, also consisting of both ARM SMOS and OKM stations (Figure 2). In addition, the ARM SMOS stations in OK were utilized to create two secondary sparse domains. Before the observations were compared, quality control (QC) beyond the standard ARM range test was added through implementation of tighter range tests specified by data quality objectives (DQOs). Furthermore, instances of poor-quality data were removed from the data set on the basis of ARM data quality reports (DQRs). Finally, to account for spatial differences in terrain, temperature observations were corrected to mean sea level by using a standard lapse rate of 6.5 C km{sup -1} and the elevation of each observing station. For the comparison, a central station was chosen in each domain. Observations during the time period 2004-2006 from each of the other stations within a respective domain were compared to those from this central station. The Pearson correlation coefficient ({rho}) and root-mean-square difference (RMSD) were the statistics used to quantify the relationship between station pairs. For each domain, the {rho} and RMSD values were plotted against the distance separating each station pair, and a least-squares (LS) regression line was fitted to the values. The regression slopes and intercepts were compared between the various domains. The results of this analysis demonstrated positive correlations between all individual station pairs for both temperature and relative humidity. In addition, the {rho} and RMSD values for both temperature and relative humidity exhibited, in general, a linear relationship with distance from a central station. The calculated slope and intercept values were comparable across most domains, and spatial differences in temperature were smaller than those for relative humidity. The findings suggest that although the sparse networks studied might provide an accurate spatial representation for climatological values of temperature and relative humidity over the specific distances between stations, the relative importance of the temperature and relative humidity observations is a critical consideration in network design.

54 ENVIRONMENTAL SCIENCES↗

ANSI and IEC standards for, and evaluation of, radiation detection instrumentation

During the last quarter of 2002, an effort was started to develop performance requirements for radiation instrumentation used for the detection of illicit trafficking of radioactive material. Coordinated by the US National Institute of Science and Technology (NIST), a team was formed to establish writing committees for the development of these requirements as American National Standards Institute (ANSI) standards. The core of the new area was developed as ANSI N42, Homeland Security Instruments. A series of standards were developed followed by testing and evaluation (T&E) protocols that would be used for specific testing. Four US National Laboratories provided T&E support and work commenced to test instruments provided by manufacturers at no cost. During this time, discussions began regarding the formation of a new work group within the International Electrotechnical Commission (IEC). This new work group would be located within technical committee (TC) 45 which addresses nuclear instrumentation. This new work group, 15B, also began developing international standards to address the same instrument types. Following development of ANSI standards, the testing and evaluation process began, running for two distinct rounds. The results of the work was consolidated by NIST and released back to individual companies as well as the user community in a controlled manner. This document will provide details regarding the standards and their basis and status, as well as some information regarding the T&E process used in the USA.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

HIGHWAY INFRASTRUCTURE FOCUS AREA NEXT-GENERATION INFRASTRUCTURE MATERIALS VOLUME I - TECHNICAL PROPOSAL & MANAGEMENTENHANCEMENT OF TRANSPORTATION INFRASTRUCTURE WITH IRON-BASED AMORPHOUS-METAL AND CERAMIC COATINGS

The infrastructure for transportation in the United States allows for a high level of mobility and freight activity for the current population of 300 million residents, and several million business establishments. According to a Department of Transportation study, more than 230 million motor vehicles, ships, airplanes, and railroads cars were used on 6.4 million kilometers (4 million miles) of highways, railroads, airports, and waterways in 1998. Pipelines and storage tanks were considered to be part of this deteriorating infrastructure. The annual direct cost of corrosion in the infrastructure category was estimated to be approximately $22.6 billion in 1998. There were 583,000 bridges in the United States in 1998. Of this total, 200,000 bridges were steel, 235,000 were conventional reinforced concrete, 108,000 bridges were constructed using pre-stressed concrete, and the balance was made using other materials of construction. Approximately 15 percent of the bridges accounted for at this point in time were structurally deficient, primarily due to corrosion of steel and steel reinforcement. Iron-based amorphous metals, including SAM2X5 (Fe{sub 49.7}Cr{sub 17.7}Mn{sub 1.9}Mo{sub 7.4}W{sub 1.6}B{sub 15.2}C{sub 3.8}Si{sub 2.4}) and SAM1651 (Fe{sub 48}Mo{sub 14}Cr{sub 15}Y{sub 2}C{sub 15}B{sub 6}) have been developed, and have very good corrosion resistance. These materials have been prepared as a melt-spun ribbons, as well as gas atomized powders and thermal-spray coatings. During electrochemical testing in several environments, including seawater at 90 C, the passive film stabilities of these materials were found to be comparable to that of more expensive high-performance alloys, based on electrochemical measurements of the passive film breakdown potential and general corrosion rates. These materials also performed very well in standard salt fog tests. Chromium (Cr), molybdenum (Mo) and tungsten (W) provided corrosion resistance, and boron (B) enabled glass formation. The high boron content of this particular amorphous metal made it an effective neutron absorber, and suitable for criticality control applications. These amorphous alloys appear to maintain their corrosion resistance up to the glass transition temperature. Visionary research is proposed to extend the application of corrosion-resistant iron-based amorphous metal coatings, and variants of these coatings, to protection of the Nation's transportation infrastructure. Specific objectives of the proposed work are: (1) fabrication of appropriate test samples for evaluation of concept; (2) collection of production and test data for coated steel reinforcement bars, enabling systematic comparison of various coating options, based upon performance and economic considerations; and (3) construction and testing of concrete structures with coated steel reinforcement bars, thereby demonstrating the value of amorphous-metal coatings. The benefits of ceramic coatings as thermal barriers will also be addressed.

36 MATERIALS SCIENCE↗

SRF Cavity High-Gradient Study at 805 MHz for Proton and Other Applications

805 MHz elliptical SRF cavities have been used for SNS as the first application for protons. At LANL, an R&D started to explore a capability of getting high-gradient cavities (40-50 MV/m) at this frequency for the future applications such as proton and muon based interrogation testing facility added to the LANSCE accelerator and a power upgrade of the LANSCE accelerator for the fission and fusion material test station. Optimized cell designs for “standard”, “low-loss” and “re-entrant” shapes, cavity test results for “standard” single-cell cavities with temperature mapping as well as surface inspection results will be presented.

43 PARTICLE ACCELERATORS↗

A search for $ZH\rightarrow \mu\mu b \bar{b}$ production at the Tevatron

The Standard Model describes with a very good accuracy all interactions of the, so far, known elementary particles. However the Higgs mechanism, which gives rise to the observed mass of these particles, has not yet been confirmed. The Higgs particle has not yet been observed, and the observation or exclusion is an important test of the Standard Model. The Standard Model does not predict the mass of the Higgs particle, however it does impose some limits on the range in which this mass can lie. In direct searches a Higgs with a mass smaller than 114.4 GeV and within 162 GeV and 166 GeV has been excluded at 95% CL at the LEP and the Tevatron colliders. The analysis presented in this thesis is aimed to search for the ZH → μμb$\bar{b}$ events in 3.1 fb -1 of data collected with the DØ detector in p$\bar{p}$ collisions at √s = 1.96 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of Single Electroweak Bosons at the Tevatron

Tests of the Standard Model with Electroweak Physics have been performed over many decades. In these proceedings, we present several analyses from the Tevatron involving single W or Z bosons. Electroweak (EW) physics has been crucial for discovering and confirming many aspects of the Standard Model (SM). Furthermore, through radiative corrections EW physics allows for indirect views of heavy particles. Indeed the relationship between W boson, top quark, and Higgs boson masses is instrumental in predicting at what mass the Higgs boson may finally be found. In these proceedings, we present several recent analyses from the Tevatron involving single W or Z bosons to test the SM. The Tevatron is a p {bar p} collider at {radical}s = 1.96 TeV located at the Fermi National Accelerator Laboratory. CDF and D0 are its two multi-purpose detectors concentrating on high P{sub T} physics. Both detectors are described in detail elsewhere.

43 PARTICLE ACCELERATORS↗